• 제목/요약/키워드: Oil Control Valve

검색결과 97건 처리시간 0.022초

전자식 비례 압력제어밸브 내 오일 오염 입자 제거 제어 알고리즘 검증 (Verification of Control Algorithm for Removing Oil Contaminant Factor from Proportional Pressure Control Valve)

  • 천수환;박진감;장경제;심성보;장민호;이진웅
    • 드라이브 ㆍ 컨트롤
    • /
    • 제18권4호
    • /
    • pp.1-8
    • /
    • 2021
  • An electro proportional pressure control valve is mainly used to control the clutch of an agricultural tractor's automatic transmission. During transmission, the operating, hydraulic oil is mix with many kinds of contaminants. The contaminants can be trapped between the valve body and spool of the proportional pressure control valve leading to abnormal operating conditions and finally critical damage to the transmission hydraulic system. The present study aimed to verify the valve control algorithm as a basic study of developing control logic that removes contaminants between the spool and the body of the proportional pressure control valve. To develop the algorithm, MATLAB/SIMULINK was used. PWM method was used to control the applied solenoid coil current. The effectiveness of the algorithm was verified by comparing the actual pressure of the normal valve with the actual pressure of the abnormal valve. Based on the present study findings, when the algorithm was applied, the response of the valve pressure according to the current became stable and oil contaminated particles were removed. In the future study, the control algorithm will be optimized for the stability of the proportional pressure reducing valve, and it will be verified in consideration with the driving of the clutch.

A Study on the Prevention of Spill of Fuel Oils and Lubricating Oils for Sunken Ships

  • Han, Won-Heui;Ju, Hae-Ji
    • 해양환경안전학회지
    • /
    • 제21권3호
    • /
    • pp.309-314
    • /
    • 2015
  • A sunken ship often involves an oil spill. This paper was carried out to minimize environmental and cost damages stemming from oil spil of sunken shipl. Through the analysis of both the standards of the oil tank system and installation, we have identified potential oil spill sites and proposed a remedy of prevention. The result of study, the air pipes of the oil tank are a vulnerable point for oil spill. Also, the remote control devices of emergency shut-off valve have poor accessibility at abandon ship, making it difficult to shut off the emergency shut-off valve. Thus, we propose the addition of a remote quick closing valve in the air pipe and the building of a central control system.

서보밸브-미터링 실린더 시스템의 오일 관성효과와 주파수 응답 특성에 관한 연구 (A Study on the Oil Inertia Effect and Frequency Response Characteristics of a Servo Valve-Metering Cylinder System)

  • 윤홍식;김성동
    • 드라이브 ㆍ 컨트롤
    • /
    • 제18권2호
    • /
    • pp.9-19
    • /
    • 2021
  • The spool displacement signal of a directional control valve, including the servo valve, can be considered as the standard signal to measure dynamic characteristics. When the spool displacement signal is not available, the velocity signal of a metering cylinder piston can be used. In this study, the frequency response characteristics of the metering cylinder are investigated for the spool displacement input. The transfer functions of the servo valve-metering system are derived taking into consideration the oil inertia effect in the transmission lines. The theoretical results of the transfer functions are verified through computer simulations and experiments. The oil inertia effect in the transmission lines was found to have a very significant effect on the bandwidth frequency of the servo valve-metering cylinder system. In order to more precisely measure the dynamic characteristics of a servo valve, the metering cylinder should be set up to minimize the oil inertia effect by increasing the inner diameters of the transmission lines or shortening their lengths.

유량제어 로직 밸브에 관한 연구 ( 비례 파핏형 로직 밸브의 정특성 ) (A Study on Flow Control Logic Valve - Static Characteristics of Proportional Poppet Type Logic Valve -)

  • 이일영;정용길;오인호
    • 수산해양기술연구
    • /
    • 제26권2호
    • /
    • pp.213-217
    • /
    • 1990
  • 본 연구에서는 유량제어 조직밸브의 기초특성을 집중정수계 모델을 사용하여, 해석하고, 이것을 실험적으로 확인하였다. 그 결과를 요약하면 아래와 같다. 1. 로직밸브의 주밸브 유량은, 그것보다 매우 소유량인 파일럿 유량에 의하여 제어할 수 있다. 2. 주밸브(파핏밸브)~파일럿실간의 개구면적이 주밸브 변위에 비례하도록 밸브를 설계함으로써 주밸브변위(혹은 면적)와 부하유량사이에 양호한 직선성이 얻어진다. 3. 유량제어 로직밸브에서 주밸브 유량의 제어범위의 상한은 기름홈의 개구면적의 최대치에 의하여 결정한다.

  • PDF

스크러버 연계 배기가스 배출제어용 3방향 댐퍼밸브의 구조 안전성 평가 (Structural Safety Evaluation of a 3-way Damper Valve for Scrubber-linked Exhaust Gas Control)

  • 김영훈
    • 한국산업융합학회 논문집
    • /
    • 제23권6_2호
    • /
    • pp.1007-1014
    • /
    • 2020
  • IMO(International Maritime Organization) continues to strengthen environmental regulations on exhaust gases such as CO2, NOx, SOx. As for sulfur oxides, from 1 January 2020, all ships on international voyages must use fuel with a sulfur content of 0.5% or less. Or, it is obligatory to use an exhaust gas treatment device that has the same effect. Shipping companies are using low-sulfur oil, replacing them with LNG fuel, or installing scrubbers that suppress sulfur oxide emissions. In the case of ships using bunker C oil, the load on the engine is lower when entering and departing, so the exhaust gas pressure is lowered and the scrubber cannot be properly utilized. Therefore, diesel oil with low sulfur content is used when entering and leaving the coast. When diesel oil is used, exhaust gas is directly discharged through the control system and piping system, and when bunker C oil is used, sulfur oxides are reduced by scrubbers through other control systems and piping systems to discharge exhaust gas. Accordingly, a company has developed a system called a three-way damper valve that can control exhaust gas emissions while integrating these two control systems and piping systems into one. In this study, the control characteristics of the integrated exhaust gas control system and structural safety against external loads in a high-temperature exhaust gas environment were reviewed.

미터링 오리피스를 이용한 방향제어밸브 위상각 대역폭 주파수 측정에 관한 연구 (A Study on the Phase Bandwidth Frequency of a Directional Control Valve based on the Metering Orifice)

  • 김성동;전세형;윤주섭
    • 드라이브 ㆍ 컨트롤
    • /
    • 제15권1호
    • /
    • pp.1-9
    • /
    • 2018
  • The spool displacement of directional control valve can be considered as the standard signal to measure the bandwidth frequency of a directional control valve. When the spool displacement is not available, the metering-orifice system is implemented in this research as an alternative way of measuring the 90 degrees phase bandwidth frequency of the hydraulic directional control valve. The inertia effect on the transmission line oil induces the phase lead of the valve load pressure when compared with the phase of spool displacement. The capacitance effect of the oil induces the phase lag of the valve load pressure. The phase of the load pressure can be adjusted to be the same as that of the spool displacement by controlling the opening area of the metering orifice. A series of experiments were conducted to verify the effectiveness of the metering orifice. The 90 degrees phase bandwidth frequency measured from the valve load pressure was significantly deviated in some cases from the frequency of the spool displacement. The metering orifice was hard to be applied to measure the -90 degrees phase bandwidth frequency of the high precision.

음향방출 계측에 의한 터빈 제어밸브 내부누설 평가연구 (Study on Evaluation of Internal Leak of Turbine Control Valve in Power Plant Using Acoustic Emission Signal Measurement)

  • 이상국
    • 동력기계공학회지
    • /
    • 제12권5호
    • /
    • pp.65-70
    • /
    • 2008
  • The purpose of this study is to verify availability of the acoustic emission in-situ monitoring method to the internal leak and operating conditions of the turbine major valves relating to safety for turbine operating and prevention of turbine trouble at nuclear power plants. In this study, acoustic emission tests are performed when the pressurized electro-hydraulic control oil flowed through turbine electro-hydraulic controller oil check valve and turbine power/trip fluid solenoid valve in the condition of actual turbine operating. The acoustic emission method was applied to the valves at the site, and the background noise was measured far the abnormal plant condition. To judge for the leak existence ell the object valves, voltage analysis and frequency analysis of acoustic signal emitted from infernal leak in the valve operating condition are performed. It was conformed that acoustic emission method could monitor for valve internal leak to high sensitivity.

  • PDF

전기.유압 서보 밸브를 이용한 유압모터계의 회전수 제어 (Speed Control of Oil Hydaulic Motor Systems Using an Electrohydraulic Servo Valve)

  • 김도태
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 1999년도 추계학술대회 논문집 - 한국공작기계학회
    • /
    • pp.405-410
    • /
    • 1999
  • Hydraulic pipeline between servo valve and actuator affect the dynamic characteristics of electrohydraulic servo systems in serveral ways. This paper deal with the speed control of oil hydraulic gear motor using electrohydraulic servo valve. The frequency and transient response of electrohydraulic servo valve coupled to a gear motor is anlayzed. In particular, the effect of short and long hydraulic pipelines between servo valve and gear motor is investigated. The dynamic characteristics of the speed control systems of gear motor with short pipeline is first described via frequency response experiments with small signal linearized analysis. Loner pipeline is applied distributed parameter pipeline model with consideration of frequency dependent viscous friction.

  • PDF

6속 자동변속기 밸브바디의 윤활오일유량 분배 특성 연구 (A Study on the Lubrication Flow Distribution in a Six-speed Automatic Transmission Valve Body)

  • 김진용;나병철;이계철
    • 한국기계기술학회지
    • /
    • 제13권2호
    • /
    • pp.79-84
    • /
    • 2011
  • In general, a valve body of the automatic transmission(AT) is controlled by the clutch, the brake and lubricating oil flow in a hydraulic system and lubricant flow for each valve can be adjusted independently. To increase the lifetime of AT, the lubrication flow rate in a valve body for a 6 speed AT based parallel hybrid electric vehicle must be provided with proper oil distribution and control. In this study, we carried out several experiments without the inner parts of AT and with a AT assembly. The variation of the flow rate on oil temperature and pressure between an oil supply port and the outlets of the lubrication port was evaluated and analyzed. In the case of AT without the inner parts, it was evident that as the oil required for an operation of the clutch and brake was discharged from the outlet port, the flow rate from each lubrication port is decreased. However, the flow rate of the AT assembly was slightly increased. In addition, the lubrication flow rate was increased with increasing the oil temperature, and also it was reduced with increasing the oil pressure. Details of the resulting data are discussed.