• 제목/요약/키워드: Office lighting

검색결과 147건 처리시간 0.025초

Elements and Structure of the Smart Lighting Design in the Office

  • Yang, Hyejin;Pan, Younghwan
    • 대한인간공학회지
    • /
    • 제35권1호
    • /
    • pp.29-38
    • /
    • 2016
  • Objective: The purpose of this research is to extract factors affecting office lighting and their relations, and then develop a framework that helps designers research and design smart lighting systems. Background: Due to the highly specialized usages of offices, the lighting system within offices also varies according to space, work, user, etc. A framework which considers these various factors and their relations is necessary for understanding and developing smart lighting systems. Method: First we extract factors affecting office lighting conditions, and select factors that can be controlled. We then analyze and develop a structure which reflects the relations among these factors from procedural perspective. Results: We divide factors affecting office lighting into physical and social factors, and then conceptualize their relations using a circular model. We then develop our framework from procedural perspective by dividing these factors into three levels, namely Subject, Action and Object. Conclusion: The developed framework organizes various factors affecting office lighting and their relations, and helps understand the procedural and structural aspects of lighting system. Application: Our framework helps designing and refining smart lighting system for complicated office spaces by helping people understanding the overall structure of office lighting.

업무공간의 조명환경 평가 연구 (A Study on evaluation of lighting environment of people who works in the office spaces)

  • 홍천기;윤아람;하미경
    • 한국실내디자인학회:학술대회논문집
    • /
    • 한국실내디자인학회 2006년도 춘계학술발표대회 논문집
    • /
    • pp.278-283
    • /
    • 2006
  • For the company, the office space is the expensive resource next to human resource. Employees are under the influence of physical characters of the office space. Among them lighting is the most effective factor in physical, biological and psychological for employees. Although there are lots of investments in architectural aspect of the office space, there is almost no investment and consideration about the lighting environment. Therefore this study was trying to find out these things as follow. First, evaluate lighting environment of people who works in the office spaces. Second, find out which factors are more affective in evaluation of lighting environment. And then with these findings this study found what should be considered as important in lighting planning of the office space. As the result of this study, however the majority of the employees are satisfied with current lighting conditions, they are not satisfied with individual operation of lighting. And in office space work type and position changes by age can affect in a large degree more than other factors. Therefore when planning lighting of the office space, it is necessary to figure out work features of Individual and group exactly and accept the difference by positions appropriately.

  • PDF

오피스 건물의 실내 조명 유형 및 계획특성에 관한 연구 (A Study on the Lighting Plan Characteristics of Office Buildings)

  • 이연수;하미경
    • 한국실내디자인학회논문집
    • /
    • 제22권1호
    • /
    • pp.47-54
    • /
    • 2013
  • For the office work environmental design, the importance of the design management is increased to improve operation efficiency as well as the aesthetic environmental implementation of the function today. Lighting is a required element ineffective operation environment. It has become more important for the aesthetic, economic, and practical reasons, to consider the luminous environment and the lighting of visual tasks separately. When the brightness is insufficient, productivity deteriorates, and the layout of the lighting located by mistake causes the fatigue of eyes. Productivity rises to office in a large number of studies so as satisfaction is low in general in the dark office, and to be bright. Therefore the purpose of this research is to suggest the right direction of lighting design of office building area. 11newly renovated office buildings are selected for this luminous environment research. We could conclusions as following through this research. First, it was planned brighter than the recommended lighting level in the most space. It shows that the accurate lighting design criteria is needed in order to achieve proper lighting environment. Second, the application of the LED lighting fixtures is continuously increased in the recent office lighting environment. It is explained that it is applied for reasons of the electrical energy reduction and the maintenance efficiency with the long life time. Third, the consideration of the lighting plan for the difference of working types is not enough. with various communication configuration through an independent plan, and the effective lighting plan that appropriateness preparation design and energy saving area vailable must be applied. Fourth, the lighting environment of the lobby needs a specialized lighting plan as are presentative space of the building.

사무소를 위한 조명설계 자료의 개발과 검증 (조명에너지와 냉방부하를 중심으로) (Verification and Development of Lighting Design Data for Office in Korea (Focused on the Evaluation of Lighting Energy and Cooling Load))

  • 김은희;서승직
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.1043-1048
    • /
    • 2006
  • This paper aimed to verify and develop lighting design data for offices in Korea. It focused on a Korean standard office value relative to lighting density and the evaluation of lighting energy and cooling load. When planning indoor lighting design, we generally utilize the lighting density value which is set $14W/m^2$ by the ASHRAE/IES standard office value. However, the value is not appropriate to apply in Korea where higher efficiency lamps are more popular than others. For calculation of a proper lighting density of Korea, we analysed distribution curves of luminous intensity(2-lamp fluorescent lighting fixture with Parabolic) and derived the new lighting density $12.64W/m^2$ as Korea standard office value. In the simulation using this value, it was shown that lighting energy and cooling load could be reduced.

  • PDF

채광시스템과 인공조명설비의 통합기술 및 성능평가연구 (Predicted Performance of the Integrated Artificial Lighting System in Relation to Daylight Levels)

  • 김곤;김정태
    • 한국태양에너지학회 논문집
    • /
    • 제22권3호
    • /
    • pp.47-56
    • /
    • 2002
  • The office is an excellent candidate for implementing daylighting techniques because of the relatively high electric lighting power densities and long daytime use pattern. The quantity of light available for a space can be translated in term of the amount of energy savings through a process of a building energy simulation. To get significant energy savings in general illumination, the electric lighting system must be incorporated with a daylight - activated dimmer control. A prototype configuration of an office interior has been established and the integration between the building envelope and lighting and HVAC systems is evaluated based on computer modeling of a lighting control facility. First of all, an energy-efficient luminaire system is designed for both a totally open-plan office interior and a partitioned office. A lighting design and analysis program, Lumen-Micro 2000 predicts the optimal layout of a conventional fluorescent lighting fixture to meet the designed lighting level and calculates unit power density, which translates the demanded amount of electric lighting energy. A dimming control system integrated with the contribution of daylighting has been applied to the operating of the artificial lighting. Annual cooling load due to lighting and the projecting saving amount of cooling load due to daylighting under overcast diffuse sky are evaluated by a computer software, ENER-Win. In brief, the results from building energy simulation with measured daylight illumination levels and the performance of lighting control system indicate that daylighting can save over 70 percent of the required energy for general illumination in the perimeter zones through the year. A 25 % of electric energy for cooling may be saved by dimming and turning off the luminaires in the perimeter zones.

사무소 건물의 외피요소가 냉난방 및 조명에너지 소비에 미치는 영향에 관한 연구 (A Study on the Effect of Envelope Factors on Cooling, Heating and Lighting Energy Consumption in Office Building)

  • 손장희;양인호
    • 조명전기설비학회논문지
    • /
    • 제26권2호
    • /
    • pp.8-17
    • /
    • 2012
  • The objective of this study is to perform an analysis of the heat(heating and cooling) and lighting energy consumption according to the window area ratio and the application of horizontal louver, which is external shading device installed for the purpose of energy savings in office buildings. For this, a building was chosen as a typical example, and the heat and lighting energy consumption was calculated by using the daylight and building energy analysis simulation. The results showed that the total energy consumption, when the lighting control was applied, was reduced by an average of 11.49[%] compared to when there was no lighting control. The smaller the glazing ratio is, the less the total energy consumption is. Also, the application of the horizontal louver increases the total energy consumption under the same condition of glazing ratio.

사무소건물에서 자연채광에 의한 조명에너지 절약의 평가 (Artificial Lighting Energy Saving by Daylighting in Office Building)

  • 임병찬
    • 설비공학논문집
    • /
    • 제16권6호
    • /
    • pp.608-613
    • /
    • 2004
  • Artificial lighting accounts for a significant portion of the energy use in office buildings. Therefore, daylighting is considered one of the fundamental design features of energy-efficient buildings. However, complex daylighting simulation tools are not suitable for most designers to help in the decision-making process. This paper provides the results of a simulation analysis to determine the potential energy savings of daylighting effects reducing electrical energy consumption for office building. A whole building simulation tool is used to determine the effects of daylighting on lighting electricity use as well as total electricity use for typical office buildings. It was determined that daylighting does not provide significant additional lighting energy savings when glass transmittance is increased over 0.7 A simplified method is developed based on the analysis results to estimate the annual electrical energy savings attributed to daylighting.

인간공학 기준에 의한 차세대형 주제어실 조명설계 및 조도 휘도 분석- 중국 광동 Ling Ao Phase II NPP MCR 환경디자인을 중심으로- (A Study on Lighting Design and Illumination and Luminance of in Advanced type Control Room by the Standard of Ergonomics - Focused on Ling Ao Phase II NPP MCR Environmental Design in Guangdong, China-)

  • 백승경;이승훈
    • 대한인간공학회지
    • /
    • 제27권2호
    • /
    • pp.73-82
    • /
    • 2008
  • Currently an office in information society is advanced to a digitalized VDT office. The VDT office has a natural luminous system prioritizing visual perception and so importance of lighting design by artificial lighting is emphasized in the VDT office. The purpose of the study is to analyze Illumination and Luminance for lighting design by the standard of ergonomics in the VDT office. The study analyzed Illumination and Luminance in the main control room of an nuclear power plant needing a design of ergonomics ACR(Advanced Control Room) type Ling Ao phase II NPP MCR in Guangdong, China. The study examined the relativity of ACR characteristics to its operator's duties and set up an outline of lighting design, the standard of ergonomics and input data for the analysis. Thus, the study examined appropriateness with the standard of ergonomics setting up the analyzed Illumination and Luminance and drew a conclusion.

소규모 사무실의 조명 색 변화에 따른 시각적 감지 및 무드 변화 분석 (Analysis on Visual Perception and Mood for Color of Light in a Small Office)

  • 강민혜;김수영
    • 설비공학논문집
    • /
    • 제23권4호
    • /
    • pp.287-296
    • /
    • 2011
  • This study examines the influences of correlated color temperature and illuminance on visual perception and temporary mood sensation in a small office. Field measurements and surveys were conducted in a full-scale mock-up model. Twenty subjects participated in the survey under six lighting conditions formed by three color temperature and two illuminance levels. Results indicate that 4000 K color temperature was effective to mitigate glare sensation from light source. Lamps with low color temperature such as 2700 K was not recommended for office lighting since they are likely to caused glare and visual discomfort. Preferred color temperature was 4000 K and 6500 K for 750 lx and 500 lx target illuminance respectively. The increase of illuminance was not an effective contributor to improve mood perception. The illuminance should be lower than 500 lx to achieve good mood, but the illuminance level in office space should be considered with visual performance simultaneously. This study suggests that fluorescent lighting fixtures with 4000 K lamps would be usefully used for office lighting since they formed friendly conditions for better visual performance.

사무용 빌딩의 조명전력 허용기준 연구 (Decision of Lighting Power Density for Office Building Lighting)

  • 이상진;이민욱;김훈
    • 조명전기설비학회논문지
    • /
    • 제26권1호
    • /
    • pp.22-28
    • /
    • 2012
  • To identify energy savings when comparing lighting designs or evaluating installed lighting, it is necessary to analyze the consumption of lighting power with respect to the electricity consumed and the lighting area. In Korea, however, these factors have not been considered in lighting design. In this paper, the lighting power-related standards on indoor lighting in foreign countries have been analyzed. It is determine appropriate lighting power consumption for indoor by calculating the energy consumption has been estimated in a lighting design adopted domestic luminaire used.