• Title/Summary/Keyword: Off-state

Search Result 1,186, Processing Time 0.024 seconds

Intelligent Control of Pneumatic Actuator using On/Off Valve (On/Off 밸브를 이용한 공압 실린더의 지능제어)

  • 안경관;표성만;송인성;이병룡;양순용
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.8
    • /
    • pp.86-93
    • /
    • 2003
  • The development of a fast, accurate, and inexpensive position-controlled pneumatic actuator that may be applied to a variety of practical positioning applications with various external loads is described in this paper. A novel modified pulse width modulation (MPWM) valve pulsing algorithm allows on/off solenoid valves to be used in place of costly servo valves. A comparison between the system response of standard PWM technique and that of the novel modified PWM technique shows that the control performance is significantly increased. A state feedback controller with position, velocity and acceleration feedback is successfully implemented as the continuous controller. Switching algorithm of control parameter using learning vector quantization neural network (LVQNN) is newly proposed, which estimates the external loads of the pneumatic actuator. The effectiveness of the proposed control algorithms are demonstrated through experiments with various loads.

A Study of Light-off Performance of Catalytic Converter with the Effect of Flow Characteristics (유동특성을 고려한 촉매변환기의 활성화(Light-off) 성능에 관한 연구)

  • 정수진;김우승
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.5
    • /
    • pp.107-120
    • /
    • 1999
  • Catalytic converters are the most fascinating and complicated chemical reactors. They are most often operated in the transient state with respect to composition, flow rate, temperature, etc. The mathermatical model developed in this work accounts for simultaneous heat and mass transfer, chemical reaction, and multi dimensional flow characteristics to analyze the light-off performance of monolithic catalytic converter with comparable mass flow rate. To validate the mathematical model, comparison between experimental and numerical results has been performed. The numerical results show a good agreement with experimental data. It is forund that inflow rate shows major effect on the characteristics of termal response of catalytic converter.

  • PDF

Analysis of Oscillation Modes Occurred by ON/OFF Time Intervals of Switching Equipments by the RCf Method (RCF 해석법을 사용한 스위칭 설비의 ON/OFF 시간간격에 의한 진동모드 해석)

  • Kim, Deok-Young;Dong, Moo-Hwan;Lee, Yun-Ho
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.1
    • /
    • pp.13-17
    • /
    • 2006
  • In this paper, the RCF(Resistive Companion Form) analysis method which is used to analyze small signal stability problems of non-continuous systems including switching devices. The RCF analysis method is mathematically rigorous and computes eigenvalue of the system periodic transition matrix based on discrete system analysis method. As an effect of switching operations, the eigenvalues of the systems are changed and newly unstable oscillation modes may be occurred. As an illustrating example, the oscillation modes of the system with different switching time intervals are computed exactly by the RCF analysis method and the results show that ON/OFF time intervals of switching equipments are important factors to make the system stable or unstable. This result shows that the RCF analysis method is very powerful to analyze small signal stability problems of power systems including switching devices such as FACTS equipments.

Hybrid Method to Compute the Cell Loss Probability in a Multiplexer with the Superposition of Heterogeneous ON/OFF Sources (이질적 ON/OFF 원을 입력으로 한 다중화 장치의 셀 손실률 계산을 위한 하이브리드 방법)

  • Hong, Jung-Sik;Kim, Sang-Baik
    • IE interfaces
    • /
    • v.12 no.2
    • /
    • pp.312-318
    • /
    • 1999
  • This paper considers the cell loss probability(CLP) in a multiplexer with the superposition of heterogeneous ON/OFF sources. The input traffic is composed of k classes. Traffic of class i is the superposition of M_(i) ON/OFF sources. Recently, the method based on the Markov modulated deterministic process(MMDP) is presented. Basically, it is the discretized model of stochastic fluid flow process(SFFP) and gives the CLP very fast, but under-estimates the CLP especially when the value of estimated CLP is very low. This paper develops the discretized model of Markov modulated Poisson process(MMPP). It is a special type of switched batch Bernoulli process(SBBP). Combining the transition probability matrix of MMDP and SBBP according to the state which is characterized by the arrival rate, this paper presents hybrid algorithm. The hybrid algorithm gives better estimate of CLP than that of MMDP and faster than SBBP.

  • PDF

A design of a robust adaptive fuzzy controller globally stabilizing the multi-input nonlinear system with state-dependent uncertainty (상태변수 종속 불확실성이 포함된 다입력 비선형 계통에 대한 전역 안정성이 보장되는 견실한 적응 퍼지 제어기 설계)

  • Park, Young-Hwan;Park, Gwi-Tae
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.2 no.4
    • /
    • pp.297-305
    • /
    • 1996
  • In this paper a novel robust adaptive fuzzy controller for the nonlinear system with state-dependent uncertainty is proposed. The conventional adaptive fuzzy controller determines the function of state variable bounding the state-dependent uncertain term in the system dynamics on the local state space by off-line calculation. Whereas the proposed method determines that function by the fuzzy inference so that it guarantees the stability of the closed loop system globally on the whole state space. In addition, the method is applicable to the multi-input system. We applied the proposed method to the Burn Control of the Tokamak fusion reactor whose dynamics contains the state-dependent uncertainty and proved the effectiveness of the scheme by using the simulation results.

  • PDF

Tracking Performance Test of Polymer Insulator with Salt Solution which is added Surface Active Agent (계면활성제가 첨가된 염수용액에 따른 폴리머 애자의 트래킹 성능 평가)

  • Cho, Han-Goo;Han, Dong-Hee;Lee, Un-Yong;Lim, Kee-Joe;Choi, In-Hyuk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1121-1124
    • /
    • 2004
  • Aging test to estimate life property of polymer insulator is executed through several international standard such as IEC 61109 and CEA tracking wheel test, but is not getting clear conclusion yet. There are two methods in the diagnosis method of polymer insulator such as off-line and on-line. The diagnosis methods in off-line are external condition analysis by the eye, contaminant analysis on surface, surface analysis, pollution withstand voltage test, power frequency flashover voltage test, lightning impulse flashover test, tensile fracture load test and flexural load test. The diagnosis methods in off-line most are the method for virgin and last aged sample. However, the diagnosis method in on-line is method that can be evaluate sample state as progressing continuously aging test in beginning, The diagnosis method in on-line is arranged as following: leakage current measurement, electric field, surface state investigation, thermal image, emitting light measurement and then so. In this paper, the tracking performance of polymer insulator with salt solution which is added surface active agent. The diagnosis of insulator sample has been analyzed by leakage current and visual examination.

  • PDF

Implementation of Quad-Band p-HEMT SP6T Switch for Handset Applications (개인 휴대통신용 4중대역 p-HEMT SR6T 스위치 구현)

  • Shin, One-Chul;Jeong, In-Ho
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.48 no.1
    • /
    • pp.97-101
    • /
    • 2011
  • Quad band p-HEMT SP6T switch for handset applications was developed. To achieve the low insertion loss and high isolation, trade-off between "On" state and "Off" state was considered by optimization of unit cell. Especially, in case isolation between transmit port and receive port, it was achieved by large capacitors and miniaturization of chip size was achieved by common voltage control and ground using back via process. Designed SP6T switch has size of $950um{\times}100um$ and take into consideration the gate recess error, excellent loss and isolation was confirmed in operating frequency.

Methods for Adding Demand Response Capability to a Thermostatically Controlled Load with an Existing On-off Controller

  • Jin, Young Gyu;Yoon, Yong Tae
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.755-765
    • /
    • 2015
  • A thermostatically controlled load (TCL) can be one of the most appropriate resources for demand response (DR) in a smart grid environment. DR capability can be effectively implemented in a TCL with various intelligent control methods. However, because traditional on-off control is still a commonly used method in a TCL, it is useful to develop a method for adding DR capability to the TCL with an existing on-off controller. As a specific realization of supervisory control for implementing DR capability in the TCL, two methods are proposed - a method involving the changing of a set point and a method involving the paralleling of an identified system without delay. The proposed methods are analyzed through the simulations with an electric heater for different power consumption levels in the on-state. Considerable cost benefit can be achieved with the proposed methods when compared with the case without DR. In addition, the observations suggest that a medium power consumption level, instead of the maximum power, in the on-state should be used for consistently obtaining the cost benefit without severe temperature deviation from the specified temperature range for DR.

A Study on the Position Control and Simulation of Pneumatic Servo System (공기압 서보 시스템의 위치 제어 및 시뮬레이션에 관한 연구)

  • Choi, Seo-Ho;Hong, Yeh-Sun;Lee, Chung-Oh
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.13 no.6
    • /
    • pp.102-113
    • /
    • 1996
  • An experimental and theoretical study on a pneumatic servo system has been conducted using on-off valves and a pneumatic cylinder. A V/I converter has been designed for rapid rising and falling of the solenoid current, which significantly improves the positioning accuracy and settling time of the servo system by shortening the valve opening time. Pulse width modulation was modified to operate on-off valves effectively. A state feedback controller which feeds back position, velocity and acceleration is used to control the system. The influence of controller gains on the system performance is studied to develop a scheme that automatically adjusts the gains using fuzzy logic theory. It is shown experimentally that the proposed fuzzy logic tuner works satisfactorily. A new method for measurements of valve effective areas is proposed, and a partially polytropic model is applied to simulation of the pneumatic system. Simulated results show good agreement with experimental data.

  • PDF

Characteristic analysis and condenser design of gas helium circulation system for zero-boil-off storage tank

  • Jangdon Kim;Youngjun Choi;Keuntae Lee;Jiho Park;Dongmin Kim;Seokho Kim
    • Progress in Superconductivity and Cryogenics
    • /
    • v.25 no.4
    • /
    • pp.65-69
    • /
    • 2023
  • Hydrogen is an eco-friendly energy source and is being actively researched in various fields around the world, including mobility and aerospace. In order to effectively utilize hydrogen energy, it should be used in a liquid state with high energy storage density, but when hydrogen is stored in a liquid state, BOG (boil-off gas) is generated due to the temperature difference with the atmosphere. This should be re-condensed when considering storage efficiency and economy. In particular, large-capacity liquid hydrogen storage tank is required a gaseous helium circulation cooling system that cools by circulating cryogenic refrigerant due to the increase in heat intrusion from external air as the heat transfer area increases and the wide distribution of the gas layer inside the tank. In order to effectively apply the system, thermo-hydraulic analysis through process analysis is required. In this study, the condenser design and system characteristics of a gaseous helium circulation cooling system for BOG recondensation of a liquefied hydrogen storage tank were compared.