• Title/Summary/Keyword: Off-pump

Search Result 300, Processing Time 0.024 seconds

Development of the Auto-Aging Test Controller for a Hydraulic Motor (유압모터 길들이기 자동시험 제어기 개발)

  • Jung, Gyu Hong;Shin, Dae Young;Seo, Dong Jin
    • Journal of Drive and Control
    • /
    • v.12 no.4
    • /
    • pp.28-34
    • /
    • 2015
  • Because heavy-duty construction vehicles such as excavators are required for good engine-room cooling capacity, a hydraulic gear motor is adopted in the cooling fan drive mechanism to actively control the output speed, instead of adopting the conventional ON/OFF type belt drive. While gear motors are normally limited to 140bars of operating pressure, those for the cooling fan are capable of operating at continuous pressures of up to 220bars. After assembly, all gear motors for high pressure must pass an aging test which is a kind of the wearing process between the gear teeth and motor housing. During the aging process with gradual pressure increments, gear sticking sometimes occurs due to abnormal wear, resulting in defects. This paper focuses on a gear-sticking free aging test controller that is designed together with the knowledge of an experienced operator and the analysis results of experimental data of the gear jamming phenomenon. From the aging experiment, it is demonstrated that the developed controller that can alter the setting pressure of the load pump is effective for stabilizing the abrupt increase in the motor input pressure, thus preventing the hydraulic motor from stopping. This is expected to be helpful for the reduction of defects and increase in productivity.

A Study about Applicability of Treatment for Water Treatment Residual Sludge Using Crossflow Tubular Membrane System (정수장 배출수 처리를 위한 Crossflow 관형막 여과 공정의 운전 적용에 관한 연구)

  • Kim, Young Hoon;Kim, Kwan Yeop;Kim, Ji Hoon;Lee, Yong Soo;Lee, Eui Jong;Eom, Jung Yeol;Kim, Hyung Soo;Hwang, Sun Jin
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.4
    • /
    • pp.499-505
    • /
    • 2009
  • Many other countries have investigated the residual sludge treatment process to save the existing water resource and produce the high suspended solid concentration sludge. There are various methods for concentrating residual sludge, but the membrane system has received the most interest for its efficiency. The objective of this study was to evaluate the application of membrane filtration system for the residual sludge treatment. The experiment equipment was composed of Lab scale Crossflow tubular membrane filtration system. Generally, crossflow operation mode demands high electric cost mainly for the pump energy. So to cut off electric cost, very low Crossflow velocity was used in this experiment. Results confirmed that suspended solid concentration of residual sludge could be concentrated to 57,000mg/L in low Crossflow velocity tubular membrane system,. This concentration can be directly injected into the dehydrator. Based on the results, we know that the Crossflow tubular membrane system should be replaced conventional residual sludge treatment system.

Aorticopulmonary Window: one case report (대동맥중격결손증[수술치험 1예])

  • 최영호
    • Journal of Chest Surgery
    • /
    • v.14 no.3
    • /
    • pp.302-306
    • /
    • 1981
  • Aorticopulmonary window is a rare anomaly among congenital heart disease. Various terms have been suggested including A-P window, A-P fenestration, fistula, aorticseptal defect etc. The defect lies usually between the left side of the ascending aorta and right wall of the pulmonary artery just anterior to the origin of the right main pulmonary artery. We have experienced one case of aorticopulmonary septal defect which was diagnosed as V5D with pulmonary hypertension in 1 4/12 year old, 7.2 Kg, male patient. Operation was done under the hypothermic cardiopulmonary bypass using 5t. Thomas cardioplegic solution. Vertical right ventriculotomy over the anterior wall of RVOT revealed no defect in the ventricular septum, and incision was extended up to the main pulmonary artery to find the source of massive regurgitation of blood through MPA. Finger tip compression of the aorticopulmanary window was replaced with Foley bag catheter balloon, and the $7{\times}10$ mm aorticoseptal defect located 15mm above the pulmonic valve was sutured continuously wih 3-0 nylon suture during azygos flow of cardiopulmonary cannula which was located distal to the window resulted massive air pumping systemically, and temporary reversal of pumping was tried to minimize cerebral air embolism. Remained procedure was done as usual, and pump off was smooth and uneventful. Postoperatively, patient was attacked frequent opistotonic seizure with no recovery sign mentally and p.hysically. Vital signs were gradually worsen with peripheral cyanosis and oliguria, and cardiac activity was arrested 1485 minutes after operation. Autopsy was performed to find the sutured window and massive edema of the brain.

  • PDF

Multi-vessel Small Thoracotomy (MVST) CABG with Robot-assisted Bilateral ITA Harvesting - A case report - (수술 로봇을 이용한 양측 내흉동맥 채취 후 시행한 최소 침습적 다혈관 관상동맥 우회술 - 1예 보고 -)

  • Chung, Jin-Woo;Lee, Jae-Won;Je, Hyoung-Gon
    • Journal of Chest Surgery
    • /
    • v.41 no.2
    • /
    • pp.264-267
    • /
    • 2008
  • The da Vinci telemanipulator system (Intuitive Surgical, Sunnyvale, CA USA) is the most advanced robotic surgical system and has been increasingly used for cardiac surgical procedures. We report out first clinical experience of use of the da Vinci telemanipulator system for endoscopic harvesting of the bilateral thoracic artery andmulti-vessel small thoracotomy off pump CABG for 3-vessel disease. The da Vinci telemanipulator system has been previously utilized primarily for mitral valve surgery.

Simulation and Energy Cost Calculation of Encapsulated Ice Storage System (캡슐형 빙축열시스템에 대한 운전 시뮬레이션 및 에너지비용 분석)

  • Lee, K.H.;Joo, Y.J.;Choi, B.Y.;Kim, S.J.
    • Solar Energy
    • /
    • v.19 no.3
    • /
    • pp.63-73
    • /
    • 1999
  • Ice storage systems are used to shift the peak load in day time into night time in summer. This paper describes a system simulation of partial ice storage system composed of an encapsulated ice storage tank, a screw compressor chiller, a heat exchanger, and a brine pump. For the system simulation, a one-dimensional model of ice storage tank is developed and validated by comparison with the performance data from measurements of an ice storage tank installed at a building. The control strategies considered in this study are chiller priority and storage priority being used commercially. The system is simulated with design cooling load of 600 RT peak load in design day and with off-design day cooling load, and the electric energy costs of the two control strategies for the same system size are compared. As a result of calculation, the energy consumption in a week for storage priority is higher than that for chiller priority control. However due to lower cost of night electric charge rate, energy cost for storage priority control is lower than chiller priority.

  • PDF

Design of Hybrid Optical Amplifiers for High Capacity Optical Transmission

  • Kim, Seung-Kwan;Chang, Sun-Hyok;Han, Jin-Soo;Chu, Moo-Jung
    • ETRI Journal
    • /
    • v.24 no.2
    • /
    • pp.81-96
    • /
    • 2002
  • This paper describes our design of a hybrid amplifier composed of a distributed Raman amplifier and erbium-doped fiber amplifiers for C- and L-bands. We characterize the distributed Raman amplifier by numerical simulation based on the experimentally measured Raman gain coefficient of an ordinary single mode fiber transmission line. In single channel amplification, the crosstalk caused by double Rayleigh scattering was independent of signal input power and simply given as a function of the Raman gain. The double Rayleigh scattering induced power penalty was less than 0.1 dB after 1000 km if the on-off Raman gain was below 21 dB. For multiple channel amplification, using commercially available pump laser diodes and fiber components, we determined and optimized the conditions of three-wavelength Raman pumping for an amplification bandwidth of 32 nm for C-band and 34 nm for L-band. After analyzing the conventional erbium-doped fiber amplifier analysis in C-band, we estimated the performance of the hybrid amplifier for long haul optical transmission. Compared with erbium-doped fiber amplifiers, the optical signal-to-noise ratio was calculated to be higher by more than 3 dB in the optical link using the designed hybrid amplifier.

  • PDF

Design of On-Chip Solar Energy Harvesting Circuit with MPPT Control (MPPT 제어 기능을 갖는 온칩 빛에너지 하베스팅 회로 설계)

  • Yoon, Eun-Jung;Park, Jun-Ho;Park, Jong-Tae;Yu, Chong-Gun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.10a
    • /
    • pp.425-428
    • /
    • 2011
  • This paper presents a micro-scale solar energy harvesting circuit with a simple MPPT control. Solar Energy is harvested using a small off-chip PV cell generating output voltages under 0.5V instead of an on-chip PV cell. A simple MPPT is implemented using a pilot PV cell and utilizing the relationship between the open-circuit voltage of a PV cell ($V_{OC}$) and its MPP voltage ($V_{MPP}$). With applying the MPPT control, the designed circuit delivers the MPP voltage to load even though the loads is heavy such that the load circuit can operate properly. The proposed circuit is designed in TSMC 0.18um CMOS process.

  • PDF

Study on Rotor and Bushing Material of Gyro-pump (자이로 펌프의 로타 및 붓싱 재료에 관한 연구)

  • 김기선;김정훈;김선화
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.3 no.2
    • /
    • pp.115-119
    • /
    • 2002
  • This study was performed to improve mechanical properties of rotor and bushing materials. SACD and SKD11 steels as rotor and bushing materials were investigated. Gas nitriding and TiN coating were carried out on SACM and SKD11 steels. TiN coating was deposited on SKD11 steel by reactive sputtering process. This coated layer was picked off during the operation because of insufficient adhesion. Gas nitriding was carried out on SACM and SKD11 steels in an ammonia atmosphere at 51$0^{\circ}C$ for 72 hrs. These gas nitrided parts showed good mechanical properties. SKD11 steels were heat-treated to obtain optimum carbide size and distribution. As a results, the hardness increased.

  • PDF

A Study on the Design of PLL for Improving of Characteristics of Locking Time and Jitter (Locking Time과 Jitter 특성의 개선을 위한 PLL 설계에 관한 연구)

  • Park, Jae-Boum;Park, Yun-Sik;Kim, Hwa-Young;Sung, Man-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.1188-1191
    • /
    • 2003
  • In this paper, we focus our attention on the improvement of locking time and jitter parameter and propose the new structure of PLL which combined with the FVC, FOVI Matcher(FVC-Output and VCO-input Matching Circuit), Control Circuit and the conventional charge pump PLL. Using fast operation characteristics of the FVC, the circuit matching FVC-Output and VCO-input (FOVI Matcher) made to synchronize very fast. Fast locking time is usually required for application where the PLL has to settle rapidly if they switch from an idle mode to a normal mode and to track high-frequency data bit rate in data recovery systems. After a fast acqusition is achieved by the using the FVC, the conventional PLL operates for removing the phase error between the reference signal and the feedback signal. Therefore this structure can improve the trade-off between acquisition behavior and locked behavior.

  • PDF

Modeling and simulation of RAON cryogenic system using EcosimPro

  • Byeongchang, Byeon;Bokuem, Kim;Denis, Groshev;Sangkwon, Jeong;Taekyung, Ki;Lingxue, Jin
    • Progress in Superconductivity and Cryogenics
    • /
    • v.24 no.4
    • /
    • pp.59-64
    • /
    • 2022
  • The cryogenic system of RAON which is Korea's first heavy ion accelerator was numerically modeled and simulated. EcosimPro which is widely used off-the-shelf numerical software for a large scale cryogenic system was used for the simulation. The model of SRF TF cryogenic system, which is the testbed of cryomodule, was firstly established. The integrity of system of SRF TF was confirmed by comparison of simulation and experimental results. The cool-down strategy to minimize the thermal stress of the cavity was simulated and an optimal strategy was established. In addition, the influence of valve and pump control parameters on the cooling time was investigated, and optimal control parameters were also derived. The cryogenic system of SCL3 that is a low-energy acceleration section including 55 cryomodules, valve boxes, and helium supply lines was also modeled. The soundness of the thermal shield system and interlock system of SCL3 was investigated.