• 제목/요약/키워드: Off-pump

검색결과 302건 처리시간 0.032초

Voltage Sags Impact on CAR and SOR of HANARO

  • Kim, Hyung-Kyoo;Jung, Hoan-Sung;Wu, Jong-Sup
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 2004년도 추계학술발표회 발표논문집
    • /
    • pp.657-658
    • /
    • 2004
  • The reactor protection system (RPS) of HANARO is a safety class system. The reactor is tripped by dropping four shut off rods (SOR). The SOR system consists of a SOR, hydraulic pump, hydraulic cylinder, solenoid valves and a power supply unit which has the AC coil contactor as a switching component. The hydraulic pump lifts up the SOR. The SOR drops by loss of the hydraulic pressure in the hydraulic circuit at the occurrence of voltage sags or interruptions. From this experiment, we knew that the magnitude of the voltage sag which impacts on this system is 70V, 500msec. The reactor regulation system (RRS) of HANARO has four CARs which are connected to the driver through a magnetic clutch. The CAR drops by loss of electromagnetic force of the magnetic clutch when the deeper voltage sags to lower than 10V, 500msec.

  • PDF

태양광발전을 이용한 독립형 지하수 양수 시스템 개발 (Development of Stand-Alone Underground Water Pumping System using Photovoltaics System)

  • 이승훈;황정훈;조운식;김만일;이준기;박문희
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.69-72
    • /
    • 2009
  • In this paper, the Stand-alone underground water pumping system was developed that is consist of Submersible Pump (AC type), Photovoltaic Array and Power converter by the application of solar energy. And also wish to introduce system that is possible to supply of drinking water or water for agriculture using solar energy at desertification area or a Off-grid area, interior etc. and operation test results. This system can use in deep tube well of 200m range with common Submersible Pump and maximized to the quantity of pumping through M.P.P.T control. Also system availability raised through apply various driving mode.

  • PDF

듀얼 위상 주파수 검출기를 이용한 CMOS RF Charge-Pump PLL 설계 (Design of CMOS RF Charge-Pump PLL using Dual PFD)

  • 최현승;김종민;박창선;이준호;이근호;김동용
    • 한국통신학회논문지
    • /
    • 제26권10B호
    • /
    • pp.1353-1359
    • /
    • 2001
  • 본 논문에서는 위상획득과정과 동기과정에서 trade-off 현상을 향상시킨 듀얼 위상 주파수 검출기를 제안하여 차지펌프 PLL을 설계하였다. 듀얼 위상 주파수 검출기는 상승에지에서 동작하는 POSITIVE 위상 주파수 검출기와 하강에지에서 동작하는 NEGATIVE 위상 주파수 검출기로 구성되어 있다. 제안한 차지펌프는 전류뺄셈회로를 이용하여 전류 부정합을 감소시켰으며, reference spurs와 전압제어발진기의 변동을 감소시킬 수 있도록 구현하였다. 제안한 차지펌프 PLL은 0.25$\mu\textrm{m}$ CMOS 공정을 사용하여 SPICE로 시뮬레이션 하였으며, 그 결과 1.6~1.85GHz의 넓은 동기범위를 나타내었다.

  • PDF

디젤엔진 연료분사펌프 캐비테이션 손상 방지를 위한 실험적 연구 (Experimental Study for the Prevention of Cavitation Damage in the Diesel Fuel Injection Pumps)

  • 김동훈;박태형;허정윤;류승협;강상립
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2011년도 후기공동학술대회 논문집
    • /
    • pp.61-61
    • /
    • 2011
  • Cavitation phenomena during the injection process of the conventional fuel injection pump for a medium-speed diesel engine can cause surface damage with material removal or round-off on the plunger and barrel port and may shorten their expected life time. An experiment of flow visualization was carried out to investigate the main cause of these cavitation damages and find the prevention method. Experimental results of flow visualization show that these damages are mainly affected by fountain-like cavitation and jet-type cavitation generated before and after the end of fuel delivery process and therefore the prevention method was designed to control these cavitation flows. From the visualization and endurance test, it was proved that this method can effectively prevent cavitation damages by controlling cavitation flows.

  • PDF

베인 펌프용 유량 제어부의 전산설계에 관한 연구 (A Study on the computer aided design for flow control valve of vane pump)

  • 이윤태
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2000년도 춘계학술대회논문집 - 한국공작기계학회
    • /
    • pp.555-560
    • /
    • 2000
  • The modeling and the numerical analysis are done so as to develop the Computer Aided Design program for the design of flow control valve attached to the vane pump. The factors affecting the flow rate characteristics, are analyzed by the experiments and the numerical methods. It is shown that the main factor affecting to the first control flow is the diameter of small rod of the spool, the main factor affecting to the second control flow is the diameter of big rod of the spool, the main factors affecting to the cut off are the main spring constant, the initial displacement of main spring and small diameter of the spool, and the dropping slope characteristics of flow rate are decided by the chamfer of spool and the dynamic characteristics of the spool.

  • PDF

펌프장 정전시 역류발생시간에 관한 연구 (A Study on the Reversal Flow Time due to Blackout)

  • 박종호;박한영
    • 한국유체기계학회 논문집
    • /
    • 제14권6호
    • /
    • pp.26-34
    • /
    • 2011
  • Waterhammer and slamming phenomena can occur when power is cut off due to reversal flow in pipeline and sudden close of check valve. Therefore analysis of reversal flow time, which means the time of reversal flow in pipeline due to pumping station blackout, is needed to protect facilities from waterhammer economically and efficiently. However systematic study on reversal flow time has not been done yet. So theory of reversal flow time analysis is proposed and verified with experiment using several parameters like pump specific speed, motor pole number, and characteristic curve of pipeline in this study.

혹한기 지역에서의 자연순환형 태양열 시스템 동파방지 (Freeze Protection for Passive Solar Water Heating System in Bitter Cold Areas)

  • 권재욱;김종현;홍희기
    • 한국태양에너지학회 논문집
    • /
    • 제31권5호
    • /
    • pp.41-46
    • /
    • 2011
  • In the present work, a new freeze protection method has been proposed for a natural circulation system of solar water heater. Though electrothermal wire is popularly used for the purpose, there are freezing troubles by wire cut-off and excessive electric power consumption. In the experimental device, hot water in a storage tank was circulated by a small pump and used to heat the outdoor pipes if the cold water pipe surface temperature falls lower than a set point. As a result, It was observed that there was no hot water waste while the solar water heating system operated without freeze and burst.

무심폐기하 관상동맥우회수술에서 아스피린과 Clopidogrel의 수술 전 병합투여가 수술 후 출혈에 미치는 영향 (Effects of Preoperative Combined Antiplatelet Agents on the Postoperative Bleeding that Occurs during Off-pump Coronary Artery Bypass Surgery)

  • 최강주;성후식;계여곤
    • Journal of Chest Surgery
    • /
    • 제41권5호
    • /
    • pp.605-609
    • /
    • 2008
  • 배경: 심폐기하 관상동맥우회술시 수술직전 항혈소판제의 병파투여는 수술 후 출혈과 출혈로 인한 수술 등의 합병증에 영향을 주는 것으로 알려져 있다. 하지만 무심폐기 하에서의 관상동맥우회술시 항혈소판제의 병합투여가 수술결과에 미치는 영향에 대해서는 잘 알려져 있지 않아 조사하고자 한다. 대상 및 방법: 2003년부터 2005년까지 무심폐기 하에서 시행한 관상동맥우회수술 중 항혈소판제(아스피린, clopidogrel)를 수술 12시간 전까지 지속적으로 사용한 19예를 대상으로 후향적 조사를 하였다. 수술 전 사용한 항혈소판제의 투여방법에 따라 아스피린 단독투여군 10예와 아스피린+clopidogrel 병합투여군 9예로 나누었는데 수술 전후의 혈소판, hemoglobin, hematocrit, prothrombin 시간, aPTT 그리고 수술 후 출혈과 출혈로 인한 수혈요구와 재수술여부에 대해 두 군을 비교하였다. 결과: 두 군간에 수술시간, 수술 중 2회 이상 측정한 ACT는 차이가 없었다. 수술 후 24시간 흉관을 통한 출혈량은 단독투여군 $697{\pm}271mL$, 병합투여군 $944{\pm}432mL$로 두 군간에 차이가 없었다. 수혈을 받은 환자의 수도 두 군 모두 3명으로 차이가 없었으며 출혈로 인해 재수술을 받은 경우는 두 군 모두 없었다. 수술 전후 측정한 헤모글로빈과 Hematocrit의 수치는 두 군간에는 차이가 없었으나 두 군 모두 수술 후의 수치가 수술 전보다 유의하게 감소하였다. 그러나 수술 전후의 감소량에 있어서는 두 군간에 차이가 없었다. 결론: 무심폐기하 관상동맥우회술에 있어 수술 전 aspirin과 clopidogrel의 병합투여는 aspirin 단독투여에 비해 수술 후 출혈로 인한 수혈이나 재수술 등의 수술조기결과에 있어 차이가 없었다. 하지만 저자의 경우는 대상 군의 수가 적어 향후 이에 대한 추가적인 연구가 필요할 것으로 사료된다.

Off-gas Analyzer를 이용한 하수처리장 단일선회류 방식 포기시스템 산소전달 효율의 평가 (Oxygen Transfer Efficiencies of A Single Spiral Roll Aeration System by the Off-gas Method)

  • 박보화;고광백;박재한;임세호;신동록;윤혜정;이지영;문태훈
    • 한국물환경학회지
    • /
    • 제22권3호
    • /
    • pp.534-539
    • /
    • 2006
  • The supply of oxygen for aeration is the largest energy consumer at activated sludge wastewater treatment plants. Replacement of less efficient aeration systems with fine pore aeration devices can save up to 50 percent of aeration energy costs. The purpose of this study was the diagnosis and evaluation of a domestic wastewater aeration system by the off-gas method which had been studied by US EPA and ASCE. For this study, an off-gas analyzer and its hood were made to collect off-gas. Also, a vacuum pump was connected to the analyzer to make suction of off-gas. Experiments were conducted at a domestic activated sludge wastewater treatment plant which had a single spiral roll aeration system installed with P.E tube diffuser. Data on OTE(f), SOTE(pw), OUR, and air flow rate were obtained from these experiments. In case of replacing an aeration system, it is recommended that it should be replaced with perforated membrane disc or ceramic disc fine bubble diffusers installed in a full floor coverage or grid pattern.

Impact of High-Dose Statin Pretreatment in Patients with Stable Angina during Off-Pump Coronary Artery Bypass

  • Youn, Young-Nam;Park, Seong-Yong;Hwang, Yoo-Hwa;Joo, Huyn-Chul;Yoo, Kyung-Jong
    • Journal of Chest Surgery
    • /
    • 제44권3호
    • /
    • pp.208-214
    • /
    • 2011
  • Background: Periprocedural treatment with high-dose statins is known to have cardioprotective and pleiotropic effects, such as anti-thrombotic and anti-inflammatory actions. We aimed to assess the efficacy of high-dose rosuvastatin loading in patients with stable angina undergoing off-pump coronary artery bypass grafting (OPCAB). Materials and Methods: A total of 142 patients with stable angina who were scheduled to undergo surgical myocardial revascularization were randomized to receive either pre-treatment with 60-mg rosuvastatin (rosuvastatin group, n=71) or no pre-treatment (control group, n=71) before OPCAB. The primary endpoint was the 30-day incidence of major adverse cardiac events (MACEs). The secondary endpoint was the change in the degree of myocardial ischemia as evaluated with creatine kinase-myocardial band (CK-MB) and troponin T (TnT). Results: There were no significant intergroup differences in preoperative risk factors or operative strategy. MACEs within 30 days after OPCAB occurred in one patient (1.4%) in the rosuvastatin group and four patients (5.6%) in the control group, respectively (p=0.37). Preoperative CK-MB and TnT were not different between the groups. After OPCAB, the mean maximum CK-MB was significantly higher in the control group (rosuvastatin group $10.7{\pm}9.75$ ng/mL, control group $14.6{\pm}12.9$ ng/mL, p=0.04). Furthermore, the mean levels of maximum TnT were significantly higher in the control group (rosuvastatin group $0.18{\pm}0.16$ ng/mL, control group $0.39{\pm}0.70$ ng/mL, p=0.02). Conclusion: Our findings suggest that high-dose rosuvastatin loading before OPCAB surgery did not result in a significant reduction of 30-day MACEs. However, high-dose rosuvastatin reduced myocardial ischemia after OPCAB.