Browse > Article
http://dx.doi.org/10.5293/kfma..2011.14.6.026

A Study on the Reversal Flow Time due to Blackout  

Park, Jong-Ho (충남대학교 기계공학과)
Park, Han-Yung (한국수자원공사 수도기술처)
Publication Information
Abstract
Waterhammer and slamming phenomena can occur when power is cut off due to reversal flow in pipeline and sudden close of check valve. Therefore analysis of reversal flow time, which means the time of reversal flow in pipeline due to pumping station blackout, is needed to protect facilities from waterhammer economically and efficiently. However systematic study on reversal flow time has not been done yet. So theory of reversal flow time analysis is proposed and verified with experiment using several parameters like pump specific speed, motor pole number, and characteristic curve of pipeline in this study.
Keywords
Inertial moment; Similarity Law; Flywheel Effect; Torque; Specific Speed; Pump Characteristic Curve; Pipeline Characteristic Curve; Slamming Phenomenon; Waterhammer Phenomenon;
Citations & Related Records
연도 인용수 순위
  • Reference
1 한국수자원공사, 2004, "그림으로 푸는 수충격해석", 동명사, 서울특별시, pp. 27-29.
2 Bruce E. Larock, Roland W. Jeppson and Gary Z. Watters, 2000, "Hydraulics of Pipeline Systems", CRC, Boca Raton London New York Washington, D.C., pp. 399-403.
3 Bruce E. Larock, Roland W. Jeppson and Gary Z. Watters, 2000, "Hydraulics of Pipeline Systems", CRC, Boca Raton London New York Washington, D.C., pp. 403-406.
4 Parmakian, J, 1963, "Waterhammer Analysis", Dover Publications, New York, pp. 103-106.
5 Richard W. Fruge, "Practical Motor Starting".