• Title/Summary/Keyword: Off-grid

Search Result 217, Processing Time 0.03 seconds

Analysis of Phase Error Effects Due to Grid Frequency Variation of SRF-PLL Based on APF

  • Seong, Ui-Seok;Hwang, Seon-Hwan
    • Journal of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.18-26
    • /
    • 2016
  • This paper proposes a compensation algorithm for reducing a specific ripple component on synchronous reference frame phase locked loop (SRF-PLL) in grid-tied single-phase inverters. In general, SRF-PLL, which is based on all-pass filter to generate virtual voltage, is widely used to estimate the grid phase angle in a single-phase system. In reality, the estimated grid phase angle might be distorted because the phase difference between actual and virtual voltages is not 90 degrees. That is, the phase error is caused by the difference between cut-off frequency of all-pass filter and grid frequency under grid frequency variation. Therefore, the effects on phase angle and output current attributed to the phase error are mathematically analyzed in this paper. In addition, the proportional resonant (PR) controller is adapted to reduce the effects of phase error. The validity of the proposed algorithm is verified through several simulations and experiments.

A Pre-Feasibility Test of Introducing Renewable Energy Hybrid Systems -Case Studies for 3 Off-Grid Islands- (도서지역 신·재생복합 전력시스템 보급 타당성 분석 -3개 도서지역 분석결과-)

  • Jang, HaNa;Kim, Suduk
    • Environmental and Resource Economics Review
    • /
    • v.15 no.4
    • /
    • pp.693-712
    • /
    • 2006
  • A pre-feasibility test is done for renewable energy hybrid power systems at off~grid islands in which the current power supply is provided only by diesel generation. We apply Homer (Hybrid Optimization Model for Electric Renewables) which was developed by the National Renewable Energy Laboratory (NREL) for the analysis to identify the cost-minimizing combination of power generating facilities for the given load profiles. Chuja-Do, Geomun-Do and Youngsan-Do have been selected for our analysis considering the wind resources data of the Korea Institute of Energy Research (KIER). Information on wind speed, solar radiation and temperature is also used for the analysis. System component cost information from overseas market has been used due to the lack of domestic information. Site specific Load profile for electricity demand for those islands are reconstructed based on the partial survey results obtained form other sources. The LCOE of the least cost hybrid power systems for Chuja-Do, Geomun-Do and Youngsan-Do are $0.278/kWh, $0.234/kWh and $0.353/kWh, respectively Considering the fact that diesel generation is being subsidized at the price of $0.300/kWh by the government, first 2 cases are economically feasible for the introduction of renewable energy hybrid systems to those islands. But the third case of Youngsan-Do does not meet the criteria. The basic differences of these pre-feasibility test results are from the differences of the site specific renewable energy conditions, especially wind resources. In summary, promoting hybrid systems in the off-grid remote island should be based on the economic feasibility test results. Not all the off-grid islands are feasible for introducing this renewable energy hybrid system.

  • PDF

OPTIMAL SHAPE DESIGN OF A S-SHAPED SUBSONIC INTAKE USING NURBS (NURBS를 이용한 S형 천음속 흡입관 최적 설계)

  • Lee B.J.;Kim C.
    • Journal of computational fluids engineering
    • /
    • v.11 no.1 s.32
    • /
    • pp.57-66
    • /
    • 2006
  • An optimal shape design approach is presented for a subsonic S-shaped intake using aerodynamic sensitivity analysis. Two-equation turbulence model is employed to capture strong counter vortices in the S-shaped duct more precisely. Sensitivity analysis is performed for the three-dimensional Navier-Stokes equations coupled with two-equation turbulence models using a discrete adjoint method For code validation, the result of the flow solver is compared with experiment data and other computational results of bench marking test. To study the influence oj turbulence models and grid refinement on the duct flow analysis, the results from several turbulence models are compared with one another and the minimum number of grid points, which can yield an accurate solution is investigated The adjoint variable code is validated by comparing the complex step derivative results. To realize a sufficient and flexible design space, NURBS equations are introduced as a geometric representation and a new grid modification technique, Least Square NURBS Grid Approximation is applied With the verified flow solver, the sensitivity analysis code and the geometric modification technique, the optimization of S-shaped intake is carried out and the enhancement of overall intake performance is achieved The designed S-shaped duct is tested in several off-design conditions to confirm the robustness of the current design approach. As a result, the capability and the efficiency of the present design tools are successfully demonstrated in three-dimensional highly turbulent internal flow design and off-design conditions.

Development of International Market Selection Models for Solar Power System Industry of Korea (국내 태양광산업의 해외진출을 위한 시장 선택 요인에 대한 분석)

  • Jeon, Jin-Hyo;Oh, Keun-Yeob;Yoo, Jin-Man
    • Korea Trade Review
    • /
    • v.44 no.1
    • /
    • pp.269-283
    • /
    • 2019
  • Due to environmental issues such as global warming, the importance of renewable energy is growing. Solar Power System is one of the most growing eco-friendly energy industries in the world, but Korea's solar energy industry faces fierce competition due to the trade regulations and changes in energy related laws in the major markets such as the U.S., EU and China. Therefore, Korea needs to diversify its export markets towards emerging markets. This paper analyzed 162 countries in the world and developed a model to measure how promising the countries are. GSMI(Grid connected Solar Market Index) and OSMI(Off-grid Solar Market Index) are invented based on the models. By using the developed model and the data of 162 countries over the 15-year period from 2000 to 2014, the foreign markets are ranked for searching the export market. According to the analysis, China, Japan, U.S, India and Taiwan ranked first to fifth in GSMI and OSMI ranking, which were followed by China, India, Bangladesh, Philippines and Afghanistan. The model developed through this research is expected to provide a more reasonable and scientific approach to the advancement of the Korean solar energy industry into overseas markets.

An Experimental Study on the Flexural Behavior of RC beams Strengthened by CRFP-Grid (탄소격자섬유로 보강한 RC보의 휨거동에 관한 실험적 연구)

  • 조병완;김영진;태기호
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10b
    • /
    • pp.845-850
    • /
    • 1998
  • Flexural tests on 3.0m reinfored concrete beams with epoxy and anchor bolt bonded CFRF-Grid reported in these tests. The selected experimental variables are concrete compressive strength, strengthening length and strengthening method. The effects of these variables in overall behavior are discussed. The results generally shown that the main flexural mode of strengthened beams is separation failure. The strengthening of the chipping by the tensile bar is really necessary in order to prevent CFRP-Grid from rip-off failure.

  • PDF

A Study on the Estimation Method of Daily Load Curve for the Optimization Design and Economic Evaluation of Stand-alone Microgrids Based on HOMER Simulation in Off-Grid Limiting the Supply of Electricity (제한급전하는 오프그리드의 독립형 마이크로그리드 최적 설계 및 경제성 평가를 위한 일부하곡선 추정 방안에 관한 연구)

  • Nam, Yong-Hyun;Youn, Seok-Min;Kim, Jung-Hoon;Hwang, Sung-Wook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.68 no.1
    • /
    • pp.27-35
    • /
    • 2019
  • There is a growing interest in various microgrid solutions that supply electricity 24 hours a day to off-grid areas where are not connected with the main grid, and Korea has many positive effects by constructing overseas microgrids as a country operating the emission trading scheme. Since it is not clear how to obtain load curves that is one of the inputs of the HOMER used to design a microgrid optimization plan, or it is necessary to examine whether electricity is supplied to the peak load level of the areas where have not received the electricity benefits from the viewpoint of the demand management, a methodology should be developed to know the load composition ratio and the shape of the daily load curve. In this paper, the relative coefficient and average load information for each load group obtained from the survey are used besides peak load and total average load. A mathematical model is proposed to derive the load composition ratio in the form of a Quadratic Programming and the load forecasting is performed using simple linear regression with future indicators. The effectiveness of the proposed method is confirmed for the Philippine island region supported by Korea Energy Agency and the Asian Development Bank.

Optimal Operating Method of PV+ Storage System Using the Peak-Shaving in Micro-Grid System (Micro-Grid 시스템에서 Peak-Shaving을 이용한 PV+ 시스템의 최적 운영 방법)

  • Lee, Gi-hwan;Lee, Kang-won
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.43 no.2
    • /
    • pp.1-13
    • /
    • 2020
  • There are several methods of peak-shaving, which reduces grid power demand, electricity bought from electricity utility, through lowering "demand spike" during On-Peak period. An optimization method using linear programming is proposed, which can be used to perform peak-shaving of grid power demand for grid-connected PV+ system. Proposed peak shaving method is based on the forecast data for electricity load and photovoltaic power generation. Results from proposed method are compared with those from On-Off and Real Time methods which do not need forecast data. The results also compared to those from ideal case, an optimization method which use measured data for forecast data, that is, error-free forecast data. To see the effects of forecast error 36 error scenarios are developed, which consider error types of forecast, nMAE (normalizes Mean Absolute Error) for photovoltaic power forecast and MAPE (Mean Absolute Percentage Error) for load demand forecast. And the effects of forecast error are investigated including critical error scenarios which provide worse results compared to those of other scenarios. It is shown that proposed peak shaving method are much better than On-Off and Real Time methods under almost all the scenario of forecast error. And it is also shown that the results from our method are not so bad compared to the ideal case using error-free forecast.

An Improved Harmonic Compensation Method for a Single-Phase Grid Connected Inverter (단상 계통연계 인버터를 위한 개선된 고조파 보상법)

  • Khan, Reyyan Ahmad;Choi, Woojin
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.3
    • /
    • pp.215-227
    • /
    • 2019
  • Grid-connected inverters should satisfy a certain level of total harmonic distortion (THD) to meet harmonics standards, such as IEEE 519 and P1547. The output quality of an inverter is typically degraded due to grid voltage harmonics, dead time effects, and the device's turn-on/turn-off delay, which all contribute to increasing the THD value of the output. The use of a harmonic controller is essential to meet the required THD value for inverter output under a distorted grid condition. In this study, an improved feedforward harmonic compensation method is proposed to effectively eliminate low-order harmonics in the inverter current to the grid. In the proposed method, harmonic components are directly compensated through feedforward terms generated by the proportional resonant controller with the grid current in a stationary frame. The proposed method is simple to implement but powerful in eliminating harmonics from the output. The effectiveness of the proposed method is verified through simulation using PSIM software and experiments with a 5 kW single-phase grid-connected inverter.

Magnetic Design of Flyback Type Snubber for IGCT Applications

  • Shirmohammadi, Siamak;Lama, Amreena;Suh, Yongsug
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.367-368
    • /
    • 2016
  • 10kV IGCT has been recently developed and has the potential to push wind turbine systems to higher power and voltage rating. Converters employing IGCTs need snubber and OVP circuit to limit the rate of current's rising and peak over voltage across IGCT during turn on and off state, respectively. The conventional RCD snubber which is used in such power converter dissipates a significant amount of power. In order to reduce the amount of energy lost by conventional RCD snubber, this paper proposes flyback type snubber comprising two coils wound on a magnetic core. The flyback snubber not only meets all of the IGCTs characteristics during on and off-state but also significantly saves the power loss. Modern magnetic model using permeance-capacitance analogy leads to more accurate loss analysis of flyback type di/dt snubber circuit in 3-level NPC type back-to-back VSC. In turns, the comparison between conventional and flyback type snubber yield the effectiveness of proposed snubber in wind turbine systems.

  • PDF

Analysis of a Synchronizing PLL System for Single-phase Grid-tie Inverters (단상 그리드연결형 인버터의 동기화를 위한 PLL 시스템 해석)

  • Tran, Quang-Vinh;Chun, Tae-Won;Lee, Hong-Hee;Kim, Heung-Geun;Nho, Eui-Cheol
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.6
    • /
    • pp.447-452
    • /
    • 2008
  • In the paper, the product-type PLL system, which is so suitable for synchronizing a single phase grid voltage is designed. The PLL system is modelled with the small signal analysis. Both the cut-off frequency of low pass filter and the optimal gain are derived by considering the transient response for synchronization as well as a distortion of synchronization signal. Through the simulation studies and experimental results, the transient response and ripple component of synchronization signal are investigated with a variation of both the cut-off frequency and gain in order to verify the performance of design.