• Title/Summary/Keyword: Odor removal efficiency

Search Result 127, Processing Time 0.02 seconds

Simultaneous Removal of TVOC and Particulate Matters Using Rectangular Bag-Filter System with for a Foundry (주물공정 악취·분진 동시 처리를 위한 여과 집진장치 개발연구)

  • Xu, Rong-Bin;Kim, Tae-Hyeung;Ha, Hyun-Chul;Piao, Cheng-Xu
    • Journal of Environmental Science International
    • /
    • v.23 no.8
    • /
    • pp.1409-1418
    • /
    • 2014
  • Foundry has an important economic value in the industry. However, the generation of air pollutants like particulate and odor are serious. Due to the unavoidable usage of molding sand, particulate occurs in almost all the processes. That accounts for the majority of respirable dust in the size less than $10{\mu}m$ As well as particulate, over 22 species of odor-causing gases and VOCs including hydrogen sulfide and ammonia are occurred. Therefore, the development of equipment that can simultaneously remove TVOC and particulate is regarded as an essential research. In this study, the spraying absorbent system was connected with the shear bag filter for the purpose to remove TVOC and particulate simultaneously. Maximization of process efficiency for the affective factors like the powder combination and injection method is conducted. The experiment was performed at the de-molding process of one foundry plant. Through these devices, the removal efficiency of more than 95% for TVOC was achieved with the absorbent that composed by 800 mesh Activated carbon (80%) and 300 mesh zeolite (20%). Also, the durability and economic evaluation were assessed. In the result of Durability assessment, the available recovery to maintain the deodorizing effect at 90% was counted to 350 degree.

Removal Characteristics of Natural Organic Matter and Taste and Odor by Advanced Water Treatment Process around the Han River Water Supply System (한강수계 고도정수처리 공정에서의 유기물과 맛·냄새의 제거특성)

  • Jae-Lim Lim;Lee, Kyung-Hyuk;Kim, Seong-Su;Chae, Seon-Ha
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.1
    • /
    • pp.13-25
    • /
    • 2007
  • The water treatment plants in Seoul Metropolitan Area, which are under Korea Water Resources Corporation(KOWACO)'s management, take water from Paldang Reservoir in Han River System for drinking water supply. There are taste and odor (T&O) problems in the finished water because the conventional treatment processes do not effectively remove the T&O compounds. As part of countermeasures for taste and odor control, KOWACO is planning to introduce advanced water treatment process such as ozone and GAC in near future. This study evaluated the removal characteristics of T&O and dissolved organic matter (DOM) to find design and operation parameters of advanced water treatment processes in a pilot-scale treatment plant. The GAC adsorption capacity for DOC in the two GAC system (GAC and $O_3$-GAC) at an EBCT of 14min was mostly exhausted after 9months. The differency of the removal efficiency of DOC between $O_3$-GAC and GAC increased with increasing operation time because the bioactivity in $O_3$-GAC process was enhanced by post-ozone process. Removal by conventional treatment was unable to reach the target TON(threshold odor number) of 3 but GAC systems at an EBCT(empty bed contact time) of 14 min were able to archive the target with few exception. During the high T&O episodes, PAC as a pretreatment together with GAC could be useful option for T&O control. However, substantial TON removal continued for more than two year (> 90,000 bed volumes). At the spiking of less concentration 26 to 61 ng/L in the influent of GAC systems, GAC absorber and $O_3$-GAC processes could meet the treatment target. The better spike control after 12 and 19 months of operation compared to that after 7 months of operation is a strong indication of biological control. The results presented in this study had shown that $O_3$-GAC process was found to be more effective for T&O control than GAC process. And the main removal mechanism in GAC systems were adsorption capacity and biodegradation.

Complex odor removal in pilot-scale biofilter with microorganisms immobilized on polymer gel media (미생물 포괄고정화 담체를 적용한 파일럿 스케일 바이오필터에서의 복합악취 제거)

  • Kim, Sun-Jin;Kim, Tae-Hyeong;Lee, Yun-Hee;Jang, Hyun-Sup;Song, Ji-Hyeon;Hwang, Sun-Jin
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.5
    • /
    • pp.741-750
    • /
    • 2011
  • A pilot-scale biofilter was constructed to discover degradation characteristics of the complex odor discharged from Ansan wastewater treatment plant. Candida tropicalis for volatile organic compounds, sulfur oxidizing bacteria(SOB) for hydrogen sulfide, and bacteria extracted from feces soil were immobilized on a polymer gel media. According to this study, the EBCT was varied from 36 sec to 18 sec. Toluene was removed as 80% along the variations, but it was recovered as 100% within 1 week. All benzene and xylene were removed during the operation while the efficiency of hydrogen sulfur was temporary decreased at 18 sec of EBCT, thereafter it was recovered to 100% within a week. The maximum elimination capacities of the benzene, toluene, xylene, and hydrogen sulfur were 6.6 g/$m^{3}$/hr, 31.7 g/$m^{3}$/hr, 7.8 g/$m^{3}$/hr, and 133.6 g/$m^{3}$/hr, respectively. There were merits on removal both organic and inorganic complex odor using the pilot-scale biofilter embedded with microorganisms immobilized on polymer gel media.

Removal of Malodorous Gases Emitted from a Wastewater Pumping Stations by Biological Methods (생물학적 방법에 의한 하수 중계펌프장의 악취제거)

  • 류희욱
    • Microbiology and Biotechnology Letters
    • /
    • v.32 no.3
    • /
    • pp.265-270
    • /
    • 2004
  • To select a promising technologies for removal of odorous gases emitted from a wastewater pump station, four methods such as activated carbon (A/C) adsorption, chemical absorption (acid and alkali scrubber), and two biofilters (polyurethane (PU) and worm cast) were investigated. The average odor removal efficiencies in the PU biofilter and A/C column was over 98%, but in a worm cast biofilter and chemical absorption were below 60-80%. The removal efficiency of PU biofilter was very stable (about 98-99%) in the range of retention times of 4-36s, and a maximum elimination capacity was $1.6${\times}$10^{ 7}$ $OUm^{-3}$$h^{-1}$ Deodorization costs for an activated carbon adsorption and a biofiltration method were investigated. With increasing odor intensity, the operating cost of the A/C column increased linearly, but the operating cost of the biofilteration increased slightly. The capital cost in a biofilter is about two times higher than that in an A/C column, but the operating cost is very lower than that of in A/C column. In conclusion, the biofiltration was evaluated one of the most promising technologies to control odor in a wastewater pump station.

Study on the applicability of the ozone / AOP and activated carbon process for the removal of trace organic contaminants and taste odor causing substances (미량오염물질 및 맛 냄새유발물질의 제거를 위한 오존/AOP 및 활성탄 공정의 적용성에 관한 연구)

  • Ha, Jeongtae;Im, Jiyeol;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.17 no.2
    • /
    • pp.155-162
    • /
    • 2015
  • This study was conducted to assess the removal characteristics of taste and odor causing compounds(2-MIB and geosmin) and micro organic matters. GAC and BAC process consisting of Ozone/AOP and activated carbon was applied. As a result, the influent concentration of 2-MIB 159 ng/L and geosmin 371 ng/L were removed 42% and 86% by ozone 1.0 mg/L, and 58%, 90% by AOP(ozone 1.0 mg/L + $H_2O_2$ 0.5 mg/L). Also it showed less than 2 ng/L effluent in GAC process and 99.8% removal efficiency in BAC process. Therefore, BAC process combining ozone/AOP and GAC is effective for persistent removal of micro organic matters, taste and odor. It is needed for optimization of Ozone/AOP process according to influent concentrations.

Nutrients removal enhancement using a modified rotating activated bacillus contactor (RABC) process (수정 RABC 공정을 이용한 영양염류 제거능 제고에 관한 연구)

  • Kim, Sunhee;Kim, Donghwan;Jang, Giung;Kim, Eung-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.1
    • /
    • pp.99-104
    • /
    • 2016
  • This study was performed to develop a new process technology for advanced wastewater treatment using a modified Rotating Activated Bacillus Contactor (RABC) process that adopts anoxic-oxic suspended biomass tanks to enhance nutrients removal. A modified lab-scale RABC process was applied to examine its applicability and to obtain the design factors for the optimum operation of the system. The modified RABC process showed a little more stable and high nutrients removal efficiency than the prototype RABC process: about 70% of nitrogen and 55% of phosphorous removal when the low organic loading (influent COD 200mg/L). However, the processing efficiency of nutrients removal rates was enhanced to great extent when high organic loading: nitrogen 90% and phosphorous 85% (influent COD 500mg/L). High organic loading stimulated extremely good biomass attachment on the reticular carrier RABC stage and the excellent nutrients removal, nevertheless with almost no offensive odor.

Decrease efficiency of Offensive Odor from Pig Excreta by Yeast Strain, Pichia farinosa NASS-2 Isolated from Soy Bean Paste (된장에서 분리한 효모(Pichia farinosa NASS-2)의 돈분 악취감소효과)

  • Yoo, Jae Hong;Park, In Cheol;Kim, Wan Gyu
    • The Korean Journal of Mycology
    • /
    • v.40 no.4
    • /
    • pp.254-257
    • /
    • 2012
  • The different microbial species were isolated from soy bean paste samples. A yeast strain NASS-2 was effective to decrease odor activity on pig excreata was identified as Pichia farinosa based on nucleotide sequences of 18S ribosomal DNA and Internal transcribed space (ITS). The extracellular fraction of P. farinosa NASS-2 was effective to decrease odor activity of pig excrements. Optimal medium component for decreasing order activity on odor material composed of soluble starch 2.0% (w/v) and yeast extract 0.8% (v/v). The decrease of odor material was maximum at $28^{\circ}C$ for 72 hours with pH 5.5. When the P. farinosa NASS-2 culture broth was treated to pig excrements, the removal efficiency was an average concentration with 1.38 ppm of ammonia gas.

Characteristics of deodorization for malodorants in aqueous solution by sonication

  • Yoo, Young-Eok;Maeda, Yasuaki
    • Journal of Environmental Science International
    • /
    • v.13 no.2
    • /
    • pp.167-173
    • /
    • 2004
  • A aqueous solution of malodorants (i.e., n-valeraldehyde, n-valeric- acid, 2-methylisoborneol, and trimethylamine) was exposed to 200KHz ultrasound with a power of 6.0W/$\textrm{cm}^2$ per unit volume in a sonochemical reactor under room temperature and atmospheric pressure condition. The concentration of malodorants decreased with irradiation time, indicating pseudo-first-order kinetics. The removal efficiency of malodorants was about from 50% to 96% decomposed after 90 minutes sonication. At the deodorization, it was determined by triangle odor bag(TOB) method for odor sensory measurement, and it indicated that over 60% of relative odors were deodorized with degradation by the sonication.

A Study on the Odor Characteristics and Identification of Microbial in Biological Swine Manure Treatment Process by Bioreactor (생물반응기를 도입한 돈분뇨의 생물학적 처리공정에서 악취발생 특성 및 미생물동정에 관한 연구)

  • Ko, Joon-il;Park, Gui-hwan;Bae, Ju-soon;Oh, Gil-young;Chung, Seon-yong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.9
    • /
    • pp.526-532
    • /
    • 2015
  • A bioreactor filling with pellets and stones was equipped to the swine manure treatment system, which is expected to emit high concentration of odor in the process of the organic wastewater treatment system, and in comparison with the activated sludge process as the control process, the reactor operation state, treatment water quality and odor emission concentration were measured. The reactor using the bioreactor proved to be much more stable in the bubble condition, treatment water transparency, etc, and BOD removal efficiency was also much better. The removal efficiency of T-N and T-P, however, showed little difference in the two reactors. Odor, as a result of examining $NH_3-N$, $NH_3$ concentratio, and complex odor, was 4 times to 24 times less emitted in the system using bioreactor than in the activated sludge system. $H_2S$, methyl mercaptan, dimethyl sulfide, and dimethyl disulfide were not found or were found in only 5 ppbs in each reactor and showed little difference between the two reactors. In the bioreactor process, Bacillus sp./ Pseudomonas sp. species were mainly found and in the activated sludge process, acterium sp. Chryseobacterium sp. species were mainly found.

Removal Efficiency of Some Odorants against Water as Sorptive Media: A Case Study on Trimethylamine and Reduced Sulfur Compounds (물을 흡수매체로 이용한 트리메틸아민과 환원황화합물의 제거효율 비교 연구)

  • Ahn, Ji-Won;Kim, Ki-Hyun;Ok, Joon-Seok;Kim, Yong-Hyun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.25 no.6
    • /
    • pp.512-522
    • /
    • 2009
  • In this study, the removal efficiency of trimethylamine (TMA) and four reduced sulfur compounds (RSC) of $H_2S$, $CH_3SH$, DMS, and DMDS was investigated using deionized water as absorbent. To this end, two types of experiments were conducted which include: (1) by passing both RSC and TMA standard gases through water contained in an impinger system and (2) by passing TMA gases through a water spray system. In the former method, TMA standard gases were effectively removed (below detection limit) in all experiments. Likewise, minor fractions of some RSC ($CH_3SH$, DMS, and DMDS) were removed by water in line with theoretical expectations. In addition, the first type of our experiment was extended further to test some commercially available odor treatment products. The results of this test showed that removal efficiencies of RSC $(8.2\pm13.7\sim43.7\pm2.48%)$ were different significantly among 4 kinds of absorbent, while the removal of TMA was consistently good as water. In the second phase of experiment, removal efficiency of TMA was tested by passing its standard gas through a water spray system. The overall results of our study showed that the actual removal efficiency of odorants by water (as sorptive media) approached the values that can be predicted theoretically (by Henry's law).