• 제목/요약/키워드: Odor removal efficiency

검색결과 127건 처리시간 0.025초

Development of Complex Module Device for Odor Reduction in Sewage

  • KIM, Young-Do;KWON, Woo-Taeg
    • 웰빙융합연구
    • /
    • 제4권3호
    • /
    • pp.1-9
    • /
    • 2021
  • Purpose: This study was conducted to develop a module with higher removal efficiency and effectiveness by adapting two or more deodorization techniques for main cause of odor pollution exposed citizen living near water treatment facilities. Research design, data and methodology: To consider the standard, unity, electrical wire, compatibility of detachable device by installing two types of dry deodorization device within one module for easy replacement. Complex odor, H2S, NH3 were collected from sewage treatment facilities for evaluation of deodorization device. Results: Using the developed application in this study, removal efficiency of complex odor, H2S, NH3 were 93%, 100%, 82%, respectively. Conclusions: The H2S removal efficiency of deodorization device was higher than bio-filter system, which were currently used by sewage treatment. Further, the device should be considered for use in efficient odor removal system.

Application of Biofilter Using Fibril-form Matrix for Odor Gas Removal

  • Lee, Gwang-Yeon;Jeong, Gwi-Taek;Lee, Kyoung-Min;Snuwoo, Chang-Shin;Lee, Woo-Tae;Cha, Jin-Myoung;Jang, Young-Seon;Park, Don-Hee
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2005년도 생물공학의 동향(XVI)
    • /
    • pp.247-251
    • /
    • 2005
  • This research was performed for developing of biological treatment process of odor gas such as MEK, $H_{2}S$, and toluene, which is generated from the food waste recycling process. To establish the operational conditions of odor gas removal by small-scale biofiltration equipment, it was continuously operated by using toluene as a treating odor object. When the odor treating microorganisms were adhered to fibril form biofilter, high removal efficiency over 93% was obtained by biofilm formation. At 400 ppm of inlet odor gas concentration and 10 sec of retention time, the removal efficiency was 76% and 93% in 1st stage reactor and 2nd stage reactor, respectively. However, the removal efficiency remained over 97% at the operational conditions above 15 sec of retention time.

  • PDF

갈대(Phragmites australls)수초를 적용한 바이오필터에서의 하수처리시설 악취저감기술 (Odor Reduction Technology in Sewage Treatment Facility Using Biofilter with Reed Grass(Phragmites australls))

  • 정진도;김규열
    • 상하수도학회지
    • /
    • 제27권3호
    • /
    • pp.373-382
    • /
    • 2013
  • In this study, a biological odor treatment system was proposed to remove odor(foul smell) materials causing several problems in the closed sewage treatment plant. This odor treatment system was composed of a two-step biofilter system in one reactor. The two-step biofilter reactor was constructed with natural purification layer in upper part and artificial purification layer in lower part. The reed grasses of water purification plants were planted in the surface area and mixed porous ceramic media were filled with the lower part of biofilter reactor. By using the above experimental apparatus, the ammonia gas removal efficiency was attained to 98.3 % and the hydrogen sulfide gas removal efficiency was appeared more than 97.7 % which shows more effective than the conventional odor removal process.

매립지 메탄 및 악취 배출 저감을 위한 바이오커버 및 바이오필터의 현장적용 평가 연구 (Evaluation of field application of biocover and biofilter to reduce landfill methane and odor emissions)

  • 채정석;전준민;오경철;류희욱;조경숙;김신도
    • 실내환경 및 냄새 학회지
    • /
    • 제16권2호
    • /
    • pp.139-149
    • /
    • 2017
  • In order to reduce odor and methane emission from the landfill, open biocovers and a closed biofilter were applied to the landfill site. Three biocovers and the biofilter are suitable for relatively small-sized landfills with facilities that cannot resource methane into recovery due to small volumes of methane emission. Biocover-1 consists only of the soil of the landfill site while biocover-2 is mixed with the earthworm casts and artificial soil (perlite). The biofilter formed a bio-layer by adding mixed food waste compost as packing material of biocover-2. The removal efficiency decreased over time on biocover-1. However, biocover-2 and the biofilter showed stable odor removal efficiency. The rates of methane removal efficiency were in order of biofilter (94.9%)>, biocover-1(42.3%)>, and biocover-2 (37.0%). The methane removal efficiency over time in biocover-1 was gradually decreased. However, drastic efficiency decline was observed in biocover-2 due to the hardening process. As a result of overturning the surface soil where the hardening process was observed, methane removal efficiency increased again. The biofilter showed stable methane removal efficiency without degradation. The estimate methane oxidation rate in biocover-1 was an average of 10.4%. Biocover-2 showed an efficiency of 46.3% after 25 days of forming biocover. However, due to hardening process efficiency dropped to 4.6%. After overturn of the surface soil, the rate subsequently increased to 17.9%, with an evaluated average of 12.5%.

축산농가에서 목초액을 이용한 암모니아 가스의 제거 특성에 관한 연구 (Ammonia Removal Characteristics by Pyroligneous Liquid at Livestock Farmhouse)

  • 박정호;전기일;정창훈
    • 한국환경과학회지
    • /
    • 제12권12호
    • /
    • pp.1309-1313
    • /
    • 2003
  • This study was carried out to obtain the optimal ammonia removal efficiency using pyroligenous liquid for the economical and environment-friendly odor removal at a petty livestock farmhouse. The ammonia removal efficiencies were evaluated due to changing dilution rates(${\times}$10, ${\times}$20, ${\times}$30, ${\times}$50 and ${\times}$100 times) and different spray amounts(10$m\ell$ and 20$m\ell$) of pyroligenous liquid. The wet scrubber device was used to remove odor in closed-type livestock farmhouse. According to dilution rate of the pyroligenous liquid, the optimum rate was 20 times and the removal efficiency increased by decreasing dilution rates. In the case of spray amounts with the optimum dilution, the amount was 20 me and the removal efficiency increased by increasing spray amount. Also, the removal efficiency by using wet deodorizing device was 83.0-97.0% with 20 times diluted liquid.

대청호 원수내 냄새 및 THM 제거방안 연구 (Removal of Odor and THM from the Raw Water of Daecheong Dam)

  • 전항배;윤기식
    • 한국수자원학회논문집
    • /
    • 제30권3호
    • /
    • pp.235-245
    • /
    • 1997
  • 대청호 원수를 취수하여 정수하는 대청수도에서 이취미를 제거하고 THM(Trihalomethanes) 발생량을 줄이기 위하여 기존 표준정수공정에 오존과 활성탄여과공정을 추가한 pilot plant 실험을 수행하였다. pilot 실험결과 표준정수공정에서 DOC(dissolved organic carbon)는 약 25% 제거되었으나, 오존공정에서는 거의 제거되지 않았고, 30일이 지난 후 GAC(granular activated carbon)에서는 약 75%까지 제거되는 것으로 나타났다. 표준정수공정에서 이취미는 약 30%, 오존산화공정에서 약 60%정도 제거되었고, 활성탄여과에서 대부분 제거되었으나, Column 1과 2에서는 DOC와 같이 이취미물질도 파과(breakthrough) 되는 것으로 나타났다. 전염소처리 대신에 중1, 2염소처리를 도입할 경우 전염소처리와 비교하여 약 25%정도의 THM발생량이 감소하였으며, 후염소처리만할 경우 약 30%까지 감소하는 것으로 나타났다.

  • PDF

분말 흡착제를 이용한 악취 저감 여과 집진장치 개발연구 (Odor Removal with Powdered Adsorbent using Bag-filter System)

  • 허영빈;김태형;하현철;박승욱
    • 한국산업보건학회지
    • /
    • 제27권4호
    • /
    • pp.291-301
    • /
    • 2017
  • Objectives: In order to improve the working environment and solve the complaints, many efforts have been made to remove the odor from the industrial process. There are many disposal methods to remove odor, but there are many disadvantages and inadequate applications. The Purpose of this study was to develop a bag-filer system for odor removal using powder adsorbent. Methods: The bag-filter system is composed of a shear bag filter, an absorbent spraying system and an absorbent circulation system. The spraying absorbent system was connected with the inlet duct of the shear bag filter for inputting adsorbent. And the absorbent circulation system can transport the collecting adsorbent from hoper to the inlet duct of the system. As a result, the adsorbent can remove odor with recycling in the system. Also affective factors like the powdered absorbent combination and injection method was researched for maximization of system efficiency. The study was conducted in two stages. The first step was testing equipment made and the second is to evaluate the efficiency of the odor control by connecting to the actual odor generation process. Results: Both experiment stages showed efficient odor control ability. The adsorption efficiency of the system is demonstrated and the odor was adsorbed well by the powder adsorbent. It is essential to accurately understand the characteristics of the odorous and use the appropriate adsorbent. Although the powder adsorbent was used in the experiment, the problem of scattering did not occur due to the high degree of system sealing. Also the system manufactured in this study was designed to recycle the adsorbent, so adsorbent reuse or batch processing is convenient. Conclusions: The applicability of the system has been proven through this research. Customized systems for industrial process and the appropriate adsorbent base on the characteristics of pollutant generation will show efficient odor collection ability.

Analysis on an Oxidation-Reduction Reaction of Photocatalytic Plasma Complex Module

  • KIM, Young-Do;KWON, Woo-Taeg
    • 웰빙융합연구
    • /
    • 제5권2호
    • /
    • pp.21-27
    • /
    • 2022
  • Purpose: This study is about photocatalytic technology and plasma oxidation-reduction technology. To the main cause of exposure to odor pollution, two deodorization techniques were applied to develop a module with higher removal efficiency and ozone reduction effect. Research design, data and methodology: A composite module was constructed by arranging two types of dry deodorization equipment (catalyst, adsorbent) in one module. This method was designed to increase the responsiveness to the components of complex odors and the environment. standard, unity, two types of oxidizing photo-catalyst technology and plasma dry deodorization device installed in one module to increase the potential by reduction to 76% of ozone, 100%, and 82%. Results: The complex odor disposal efficiency was 92%. Ammonia was processed with 50% hydrogen sulfide and 100% hydrogen sulfide, and ozone was 0.01ppm, achieving a target value of 0.07ppm or less. The combined odor showed a disposal efficiency of 93%, ammonia was 82% and hydrogen sulfide was 100% processed, and ozone achieved a target value of 0.07 ppm or less. Conclusions: Ozone removal efficiency was 76% by increasing Oxidation-Reduction Reaction(ORR). The H2S removal efficiency of the deodorizer was higher than that of the biofilter system currently used in sewage disposal plants.

우엉발효추출물을 이용한 생활악취물질 제거효율 조사 (Removal Efficiency of odor substance Using Arctium Lappa Root extract)

  • 이동섭;박진식
    • 한국환경과학회지
    • /
    • 제23권11호
    • /
    • pp.1953-1961
    • /
    • 2014
  • Increasing public concerns over odors and air regulations necessitates the remediation of a wide range of odor substances for industrial and indoor purpose. Currently, the wet scrubbing technique by neutralization using oils is being used to treat odor substances such as Ammonia($NH_3$), Methyl Mercaptan($CH_3SH$), Hydrogen Sulfide($H_2S$), Methylamine($CH_3NH_2$), Acetaldehyde($CH_3CHO$). The chemical analysis is performed to analyze the composition of an Arctium Lappa Root extract by VOC analyzer(Phocheck 5000Ex, ION SCIENCE co.) The objectives of the this study are to clarify the possibility of the neutralization of odors sprayed in the fixed bed and determine the removal efficiencies for different input odor concentrations. It is found that Ammonia($NH_3$), Methyl Mercaptan($CH_3SH$), Hydrogen Sulfide($H_2S$), Methylamine($CH_3NH_2$), Acetaldehyde($CH_3CHO$) are significantly removed and their removal efficiencies are higher than 98%. The kitchen detergent with Arctium Lappa Root extract showed excellent removal efficiencies of odor substances and high possibility for the development of kitchen detergent with odor removal.

Pulse UV 장치를 이용한 먹는 물의 이취미 유발물질 제거효과에 관한 연구 (Removal of taste and odor causing compounds in drinking water using Pulse UV System)

  • 손진식;박순호;정의택
    • 상하수도학회지
    • /
    • 제26권2호
    • /
    • pp.219-228
    • /
    • 2012
  • Problems due to the taste and odor in drinking water are common in treatment facilities around the world. Taste and odor are perceived by the public as the primary indicators of the safely and acceptability of drinking water, and are mainly caused by the presence of two semi-volatile compounds-2-methylisoborneol(2-MIB) and geosmin. Conventional treatment processes in water treatment plants, such as coagulation, sedimentation and chlorination have been found to be ineffective for the removal of 2-MIB and geosmin. Pulse UV system is a new UV irradiation system that is a non-mercury lamp-based alternative to currently used continuous wave systems for water disinfection. This study shows pulse UV system to be effective in treatment of these two compounds. Geosmin removal efficiency of UV process alone achieved approximately 70% at 10sec contact time. 2-MIB removal efficiency of UV only process achieved approximately 60% at 10sec contact time. The addition of $H_{2}O_{2}$ 7mg/L increased geosmin and 2-MIB removal efficiency upto approximately 94% and 91%, respectively.