• 제목/요약/키워드: Odor detection system

검색결과 20건 처리시간 0.026초

후각 센서를 이용한 냄새 인식 및 실감형 멀티미디어 표현 기술 (A technology of realistic multi-media display and odor recognition using olfactory sensors)

  • 이현구;노용완
    • 디지털산업정보학회논문지
    • /
    • 제6권4호
    • /
    • pp.33-43
    • /
    • 2010
  • In this paper, we propose a floral scent recognition using odor sensors and a odor display using odor distribution system. Proposed odor recognition has method of correlation coefficient between sensors that select optimal sensors in floral scent recognition system of selective multi-sensors. Proposed floral scent recognition system consists of four module such as floral scent acquisition module, optimal sensor decision module, entropy-based floral scent detection module, and floral scent recognition module. Odor distribution system consists of generation module of distribution information, control module of distribution, output module of distribution. We applied to floral scent recognition for performance evaluation of proposed sensors decision method. As a result, application of proposed method with floral scent recognition obtained recognition rate of 95.67% case of using 16 sensors while applied floral scent recognition system of proposed sensor decision method confirmed recognition rate of 96% using only 8 sensors. Also, we applied to odor display of proposed method and obtained 3.18 thorough MOS experimentation.

향 검지 시스템의 특성 해석 및 평가에 관한 연구 (A Study on the Properties Analysis and Estimation of Odor Detection System)

  • 최충석
    • 한국화재소방학회논문지
    • /
    • 제23권2호
    • /
    • pp.1-5
    • /
    • 2009
  • 본 연구에서는 분전반의 설치 형태를 조사하였고, 향 검지 시스템의 재현 실험을 통해서 전기 재해 예방의 가능성을 확인하고자 한다. 주택용 분전반 내에 설치된 차단기는 MCCB, RCD 순서로 되어 있으나, 산업용은 혼용되고 있다. 접속이 부적절하게 된 단자대에 가진기를 이용하여 진동을 가했을 때 불꽃이 확인되었다. 단자대에 향 캡슐을 부착하여 실험한 결과, 발생한 열에 의해 캡슐이 정확하게 작동되었다. 센서의 설치 위치에 따라 검지 시간의 차이는 약 10초 이었다. 향 검지 시스템은 전기 설비 사고 예방이 가능한 것으로 판단된다. 전선의 접속부에서 이상 발열이 있을 때 과열의 상태를 관리자에게 경보해 줌으로써 사고 예방이 가능할 것으로 판단된다.

전자코를 이용한 살모넬라 식중독균 판정 (Identification of Salmonella Pathogen Using Electronic Nose)

  • 김기영;이민욱;이강진;최규홍;노광모;강석원;장영창
    • Journal of Biosystems Engineering
    • /
    • 제30권2호
    • /
    • pp.121-126
    • /
    • 2005
  • In this study, a commercial electronic nose system was used to detect contamination of Salmonella bacteria. Odors from growth media contaminated with Salmonella typhimurium, Salmonella enteritidis, or Escherichia coli were collected and analyzed to evaluate a possibility of rapid detection of pathogen. Odor chromatograph showed that S. typhimurium, S. enteritidis, and E. coli had 7,6, and 9 main peaks, respectively. Retention time and intensity of the peaks were distinct for different bacteria species. Principal component analysis (PCA) were also performed to clarify odor differences. Analysis results showed that the odors for uncontaminated growth medium were differently grouped from the odors of contaminated one. The odor from the bacteria growth identified with two principal components, PC 1 and PC2. In PCA figures, odor groups were moved from left to right of PC 1 with elapse of the bacteria growth time. The electronic nose system could detect odors of S. typhimurium, S. enteritidis, E. coli when their concentration were $1.85\times10^6\;cfu/g,\;2.25\times10^6\;cfu/g,\;and\;1.8\times10^5 cfu/g$, respectively.

나방의 성페로몬 감지 (Perception of Sex Pheromone in Moth)

  • 박계청
    • 한국응용곤충학회지
    • /
    • 제61권1호
    • /
    • pp.1-14
    • /
    • 2022
  • 나방은 성페로몬에 대한 통신시스템이 잘 발달되어 있다. 동종의 암컷이 방출하는 성페로몬을 원거리에서 감지하여 암컷을 정확히 찾아가 교미할 수 있도록 하기 위해서, 수컷 나방은 고도로 발달된 성페로몬 감지 시스템을 갖고 있다. 이러한 시스템을 이용해서 수컷 나방은 페로몬 냄새기둥(plume)을 따라 바람을 거슬러 비행하면서 간헐적으로 감지되는 페로몬 냄새가닥(odor filaments)을 추적하는 고정행동양식(stereotypic behavior)을 보인다. 일반적으로 여러 성분으로 구성되는 나방의 암컷 성페로몬은 그 조성이 종특이적(species-specific)이며, 비슷한 성분을 공유하는 유사종들이 방출하는 성페로몬과 동종의 암컷이 방출하는 성페로몬을 정확히 구분하기 위해서 수컷 나방은 촉각에 여러 종류의 고도로 특화된 페로몬 감각세포들을 갖고 있어서, 이들이 페로몬을 감지할 때 나오는 신경 신호들을 종합해서 동종의 페로몬을 인식하여 행동반응이 일어나게 된다. 수컷 나방은 보통 동종의 페로몬 성분뿐만 아니라 유사종이 사용하는 페로몬 성분들을 특이적으로 감지하는 길항적(antagonistic) 냄새감각세포들도 갖고 있어서 페로몬 식별력을 강화한다. 본 종설에서는 지금까지 보고된 수컷 나방의 페로몬 감지 시스템과 이와 연관된 수컷의 감각기 및 행동반응에 대한 연구 결과들을 정리하고, 이를 종합하여 앞으로의 연구 방향을 제시하고자 한다.

엣지 시스템을 위한 LSTM 기반 화재 및 악취 예측 모델 (LSTM-based Fire and Odor Prediction Model for Edge System)

  • 윤주상;이태진
    • 정보처리학회논문지:컴퓨터 및 통신 시스템
    • /
    • 제11권2호
    • /
    • pp.67-72
    • /
    • 2022
  • 최근 인공지능을 활용한 다양한 지능형 응용서비스 개발이 활발히 진행 중이다. 특히, 제조 산업 현장에서는 인공지능 기반 실시간 예측서비스 연구가 활발히 진행 중이며 이중 화재 및 악취를 감지·예측할 수 있는 인공지능 서비스에 대한 요구가 매우 높다. 하지만 기존 감지·예측시스템은 화재 및 악취 발생 예측이 아닌 발생 후 감지 서비스가 대부분이다. 이는 인공지능 기반 예측서비스 기술이 적용되어 있지 않기 때문이다. 또한, 화재 예측 및 악취 감지·예측서비스는 초저지연 특징을 가진 서비스이다. 따라서 초저지연 예측서비스를 제공하기 위해 엣지 컴퓨팅 기술이 인공지능 모델과 결합되어 클라우드에 비해 빠른 추론 결과를 현장에 빠르게 적용할 수 있도록 개발 중이다. 따라서 본 논문에서는 제조 산업 현장에서 가장 많이 요구되는 화재 예측 및 악취 감지·예측에 사용할 수 있는 LSTM 알고리즘 기반 학습모델을 제안한다. 또한, 제안하는 학습모델은 엣지 다바이스에 구현이 가능하도록 설계하였으며 사물인터넷 단말로부터 실시간 센서데이터를 수신하고 이 데이터를 추론 모델에 적용하여 화재 및 악취 상태를 실시간으로 예측할 수 있도록 제안한다. 제안된 모델은 3가지 성능 지표를 통해 학습모델의 예측 정확도를 평가하였으며 평가 결과는 평균 90% 이상 성능을 보였다.

An Identification Technique Based on Adaptive Radial Basis Function Network for an Electronic Odor Sensing System

  • Byun, Hyung-Gi
    • 센서학회지
    • /
    • 제20권3호
    • /
    • pp.151-155
    • /
    • 2011
  • A variety of pattern recognition algorithms including neural networks may be applicable to the identification of odors. In this paper, an identification technique for an electronic odor sensing system applicable to wound state monitoring is presented. The performance of the radial basis function(RBF) network is highly dependent on the choice of centers and widths in basis function. For the fine tuning of centers and widths, those parameters are initialized by an ill-conditioned genetic fuzzy c-means algorithm, and the distribution of input patterns in the very first stage, the stochastic gradient(SG), is adapted. The adaptive RBF network with singular value decomposition(SVD), which provides additional adaptation capabilities to the RBF network, is used to process data from array-based gas sensors for early detection of wound infection in burn patients. The primary results indicate that infected patients can be distinguished from uninfected patients.

냄새성분 측정을 위한 기체 크로마토그래피/불꽃이온화 검출/후각 검출법의 개발 (Method Development for the Odor-Active Compound Determination by Gas Chromatography/Flame Ionization Detection/Olfactometry)

  • 김만구;정영림;서영민;양희화
    • 분석과학
    • /
    • 제14권2호
    • /
    • pp.180-190
    • /
    • 2001
  • 화합물에 포함된 냄새를 유발하는 물질은 다양한 성분으로 되어 있다. 냄새를 유발하는 휘발성 화합물의 분석에는 GC 또는 GC/MSD 등이 많이 사용된다. 그러나, 이들 분석기기는 전체 휘발성 성분의 profile이나 특정성분의 함량을 정량적으로 분석할 수는 있으나, 냄새를 유발하는 지배적인 성분이 무엇인지 파악하기가 어렵다. 이러한 문제점을 해결하기 위해 사용되는 방법에는 GC-Sniffing 또는 GC-Olfactometry법 등이 있다. 본 연구에서는 복합적인 냄새성분을 검출하기 위해 사람의 후각을 이용하는 olfactometry를 기존 GC에 결합시켜 분리컬럼에서 분리된 시료가 동시에 검출되는 GC/FID/Olfactometry를 개발하였다. FID와 ODP 신호간의 시간차이는 물질의 종류와 농도, 그리고 패널에 따라 다르게 나타났다. 일반적으로 휘발성과 냄새강도는 큰 물질일수록, 패널의 호흡주기가 짧을수록 두 신호간의 시간차이가 적었다. 그러므로, 정확한 냄새 원인물질의 규명에는 이들 신호의 관계에 대한 고찰이 필요하다.

  • PDF

MCCB 단자 접속부의 접촉불량에 의한 과열사고 방지기법에 관한 연구 (Research on Overheat Protection Techniques of Connection Parts of MCCB by Poor Contact)

  • 김동우;이기연;문현욱;김향곤;최충석
    • 한국화재소방학회논문지
    • /
    • 제22권4호
    • /
    • pp.54-60
    • /
    • 2008
  • 본 논문에서는 MCCB 및 단자대 접속부의 접촉불량에 의한 소손특성을 분석하였으며, 발열을 감지하여 화재를 예방할 수 있는 다양한 기법들을 제시하였다. 첫째로, 열전대를 사용하는 방법과 적외선 열화상기를 사용하여 접촉불량 등의 원인에 의해서 발열을 감지하는 방법을 분석하였다. 또한, 접촉불량 발생시 변색여부로 쉽게 이상유무 판단이 가능한 서모캡의 특성을 분석하였으며, 공간 등의 제약을 덜 받으면서 접속부위에 상시 설치하고 감시할 수 있는 방식인 향 캡슐과 향 검지기를 사용하여 과열을 감지하는 시스템의 원리 및 특징을 분석하였다. 마지막으로, 가융합금의 용융특성을 응용한 접촉불량 감지나사를 제작하여 단자대에 적용 및 실험하여 성능을 검증하였다. 상기 제시된 기법들을 적절히 적용된다면 MCCB 및 단자대등의 접속부의 접촉불량에 의한 전기화재 예방에 기여할 수 있을 것으로 기대된다.

2008년과 2010년 지정 VOC 계열 신규악취성분들에 대한 분포특성 조사: 도심 하수환경 중 빗물받이에 대한 연구 (Measurements of Volatile Organics, Newly Designated Offensive Odorants in Korea in 2008 and 2010: a Case Study on Gutter System)

  • 안지원;홍원필;이은희;김기현
    • 한국대기환경학회지
    • /
    • 제26권3호
    • /
    • pp.305-317
    • /
    • 2010
  • In this research, a total of 11 newly designated offensive odorants in Korea in 2008 and 2010 (styrene (S), toluene (T), p-xylene (p-X), methyl ethyl ketone (MEK), methyl isobutyl ketone (MIBK), butyl acetate (BuAc), isobutyl alcohol (i-BuAl), propionic acid (PA), butyric acid (BA), isovaleric acid (IA), and valeric acid (VA)) were selected as target compounds and analyzed from two types of gutter system in the urban environment. Because of the environmental significance of these compounds as offensive odorants, the results are meaningful enough to explore their behavior and distribution in the urban environmental systems. In the course of this study, samples were collected three times a day from two different gutter systems representing the wet (W) and dry (D) conditions. A large fraction of volatile organic compounds (VOCs) data fell into method detection limit (MDL) range with exceptions of toluene, p-xylene, and methyl ethyl ketone. In contrast, the results of organic fatty acids were distinguished by the relative dominance of butyric acid and propionic acid over others. If the concentration data of all odorants were converted into odor intensity (OI), the results of aromatics, ketones, acetate, and alcohol groups approached zero level. However, odor intensity of organic fatty acids was noticeably higher with the value of 2.8 (on average) from both W and D system, suggesting their potent roles as odorants in gutter system.

Evaluation of an Ammonia Passive Sampler Using Chamber System

  • Yim, Bong-Been;Kim, Sun-Tae
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제22권E1호
    • /
    • pp.1-8
    • /
    • 2006
  • The purpose of this study was to evaluate the efficiency of a passive sampler in measuring atmospheric ammonia concentrations using chamber system. The ability of the passive sampler to quantitatively determine atmospheric ammonia gas was almost identical to that of the reference method (indophenol method). There was no significant difference between concentrations measured by the two methods. The detection and quantification limits of the ammonia passive sampler were 16.9 ppb and 25.3 ppb, respectively, for a 24-h sampling period. The average coefficient of variation between replicated samplers was $6.7{\pm}4.2%$. The concentrations measured by the two methods (passive sampler and indophenol method) were no significant difference with good a correlation (correlation coefficient=0.964).