• Title/Summary/Keyword: Odor Gas

Search Result 289, Processing Time 0.027 seconds

Fabrication and characterization of a small-sized gas identification instrument for detecting LPG/LNG and CO gases

  • Lee Kyu-Chung;Hur Chang-Wu
    • Journal of information and communication convergence engineering
    • /
    • v.4 no.1
    • /
    • pp.18-22
    • /
    • 2006
  • A small-sized gas identification system has been fabricated and characterized using an integrated gas sensor array and artificial neural-network. The sensor array consists of four thick-film oxide semiconductor gas sensors whose sensing layers are $In_{2}O_{3}-Sb_{2}O_{5}-Pd-doped\;SnO_2$ + Pd-coated layer, $La_{2}O_{5}-PdCl_{2}-doped\;SnO_2,\;WO_{3}-doped\;SnO_{2}$ + Pt-coated layer and $ThO_{2}-V_{2}O_{5}-PdCl_{2}\;doped\;SnO_{2}$. The small-sized gas identification instrument is composed of a GMS 81504 containing an internal ROM (4k bytes), a RAM (128 bytes) and four-channel AD converter as MPU, LEDs for displaying alarm conditions for three gases (liquefied petroleum gas: LPG, liquefied natural gas: LNG and carbon monoxide: CO) and interface circuits for them. The instrument has been used to identify alarm conditions for three gases among the real circumstances and the identification has been successfully demonstrated.

A Study on the Measurement of Halitosis of Human Mouth with Chemical Gas Sensor Arrays (화학 가스센서를 활용한 구취측정 방법에 관한 연구)

  • Lee, Seok-Jun;Kim, Sun-Tae;Kim, Han-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.279-285
    • /
    • 2011
  • This study was carried out to apply chemical gas sensors for the identification of bad breath which is one of the important sensitive problem for the humans' daily life. Seven sensors, including five semiconductor sensors and two electrochemical sensors, were tested for the three panels three times in several conditions. The results showed that the reproducibility of sensors were generally good, and electrochemical sensors showed better reproducibility while semiconductor sensors showed better sensitivity. No rinsing before measurement showed relatively better results in terms of both sensitivity and reproducibility. Semiconductor gas sensors for hydrogen sulfide shows the highest sensitivity, and it was recommended to use the odor-free bag for the measurement of bad breath.

An Air Cleaning Efficiencies of Wet Air Cleaner in the Swine Finishing Winch Curtain Stall (윈치커튼식 비육돈사에서 습식공기정화기의 공기정화 효율 분석)

  • Oh, I.H.;Kim, W.G.;Lee, H.S.
    • Journal of Animal Environmental Science
    • /
    • v.14 no.2
    • /
    • pp.75-80
    • /
    • 2008
  • High concentration of $NH_3$, $CO_2$, and lots of dust are found in modern densely raising stall system, as results, they provide a negative influence on animal and lamer health, and production ability. Therefore, it is necessary to keep clean the inside of stall air to increase the productivity. A wet type air cleaner has been developed to clean the stall air. The work principle is that the inside air are sucked through the fan, and the rotating discs make a water into a fineness spray and blows into the stall. The spray can take the dust, $NH_3$, and odor from the stall inside air and give back to the circulating water, which can be refreshed in 2 hours interval. In the Present study, we measured the $NH_3$, dust, odor, temperature and humidity in a swine stall that were installed two wet air cleaners with 700 fattening swine with on-mode and off-mode of wet air cleaners. In fall, the concentrations of $NH_3$ in off-mode stall were maximum 24 ppm and minimum 16 prm, and the average was 18.2 ppm. However in on-mode stall the $NH_3$ concentrations were maximum 7ppm and minimum 1ppm, and the average was 2.7ppm. The concentration of $NH_3$ in on-mode was 74% lower than off-mode stall. Odor was measured by olfactometer. In the off-mode stall, the odor unit was 3,800 OU/$m^3$, but in the on-mode stall the odor unit was 2,100 OU/$m^3$ Odor removal efficiency was about 45% in on-mode stall. The dust measure was divided into 3 categories, $PM_{10}$, $PM_{2.5}$ and $PM_{1.0}$. Whereas the $PM_{10}$ showed no significant differences between the tests, $PM_{2.5}$ and $PM_{1.0}$ in the fine particle range reduced remarkably in the on-mode.

  • PDF

Effect of Substitute Processed Dustproof Fly-Ash as a Bedding Materials at Pigpens (방진처리 석탄회의 돈사깔짚 대체 . 이용효과)

  • 김영민;김재황;김삼철;하홍민;고영두
    • Journal of Animal Environmental Science
    • /
    • v.6 no.3
    • /
    • pp.133-140
    • /
    • 2000
  • This study was carried out to determine a suitable mixing rate to utilize the PDF as a bedding materials at the pigpens and investigate the effect of substitute processed dustproof fly-ash(PDF) on the odor. In proportion to the increase of substitute rate of the PDF, the utilizable period was extended, and there was a little change of the moisture in the bedding materials. At all the treatment of PDF, there was the significant effect on the maggots and parasites but it didn\`t hinder in the biodegradation. According to highly mixing rate, PDF decreased in the noxious gas ($NH_3$ and $H_2$S) emission. In conclusion, the mixing rate of 30% or above this substituted level will increase replacement terms, and reduce the sawdust cost and the pollutions of breed pigs.

  • PDF

Ammonia Removal Characteristics by Pyroligneous Liquid at Livestock Farmhouse (축산농가에서 목초액을 이용한 암모니아 가스의 제거 특성에 관한 연구)

  • 박정호;전기일;정창훈
    • Journal of Environmental Science International
    • /
    • v.12 no.12
    • /
    • pp.1309-1313
    • /
    • 2003
  • This study was carried out to obtain the optimal ammonia removal efficiency using pyroligenous liquid for the economical and environment-friendly odor removal at a petty livestock farmhouse. The ammonia removal efficiencies were evaluated due to changing dilution rates(${\times}$10, ${\times}$20, ${\times}$30, ${\times}$50 and ${\times}$100 times) and different spray amounts(10$m\ell$ and 20$m\ell$) of pyroligenous liquid. The wet scrubber device was used to remove odor in closed-type livestock farmhouse. According to dilution rate of the pyroligenous liquid, the optimum rate was 20 times and the removal efficiency increased by decreasing dilution rates. In the case of spray amounts with the optimum dilution, the amount was 20 me and the removal efficiency increased by increasing spray amount. Also, the removal efficiency by using wet deodorizing device was 83.0-97.0% with 20 times diluted liquid.

Intelligent Air Quality Sensor System with Back Propagation Neural Network in Automobile

  • Lee, Seung-Chul;Chung, Wan-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.468-471
    • /
    • 2005
  • The Air Quality Sensor(AQS), located near the fresh air inlet, serves to reduce the amount of pollution entering the vehicle cabin through the HVAC(heating, ventilating, and air conditioning) system by sending a signal to close the fresh air inlet door/ventilation flap when the vehicle enters a high pollution area. One chip sensor module which include above two sensing elements, humidity sensor and bad odor sensor was developed for AQS (air quality sensor) in automobile. With this sensor module, PIC microcontroller was designed with back propagation neural network to reduce detecting error when the motor vehicles pass through the dense fog area. The signal from neural network was modified to control the inlet of automobile and display the result or alarm the situation. One chip microcontroller, Atmega128L (ATmega Ltd., USA) was used. For the control and display. And our developed system can intelligently detect the bad odor when the motor vehicles pass through the polluted air zone such as cattle farm.

  • PDF

An Identification Technique Based on Adaptive Radial Basis Function Network for an Electronic Odor Sensing System

  • Byun, Hyung-Gi
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.3
    • /
    • pp.151-155
    • /
    • 2011
  • A variety of pattern recognition algorithms including neural networks may be applicable to the identification of odors. In this paper, an identification technique for an electronic odor sensing system applicable to wound state monitoring is presented. The performance of the radial basis function(RBF) network is highly dependent on the choice of centers and widths in basis function. For the fine tuning of centers and widths, those parameters are initialized by an ill-conditioned genetic fuzzy c-means algorithm, and the distribution of input patterns in the very first stage, the stochastic gradient(SG), is adapted. The adaptive RBF network with singular value decomposition(SVD), which provides additional adaptation capabilities to the RBF network, is used to process data from array-based gas sensors for early detection of wound infection in burn patients. The primary results indicate that infected patients can be distinguished from uninfected patients.

The Study on the Removal of Odor Emitting Environmental Fundamental Facility (환경기초시설에서 발생하는 악취가스 제거에 관한 연구)

  • Lee, Byung-Kwan;Lee, Sang-Hun;Tak, Sung-Je;Lee, Byung-Ki
    • Journal of Climate Change Research
    • /
    • v.8 no.1
    • /
    • pp.51-56
    • /
    • 2017
  • The objective of the research project is to develop the hybrid deodorizer for the removal of residual harmful gases generating during pretreatment process of biogas. This hybrid deodorizer is capable of treating harmful gases that contains hydrogen sulfide ($H_2S$), ammonia ($NH_3$) and other odor substances. This hybrid deodorizer reduced the hydrogen sulfide content from approximately 150~200 ppm to less than 16 ppm. These residual harmful gases were effectively removed in the effluent, achieving up to 97% removal of $H_2S$ and 94% removal of $NH_3$ after treatment using hybrid deodorizer.

Method Development for the Odor-Active Compound Determination by Gas Chromatography/Flame Ionization Detection/Olfactometry (냄새성분 측정을 위한 기체 크로마토그래피/불꽃이온화 검출/후각 검출법의 개발)

  • Kim, Man-Goo;Jung, Young-Rim;Seo, Young-Min;Yang, Hee-Hwa
    • Analytical Science and Technology
    • /
    • v.14 no.2
    • /
    • pp.180-190
    • /
    • 2001
  • Oder-active compounds are complex in a sample. These compounds are usually analyzed by GC or GC/MSD while such analytical measurement can quantify specific volatile organic compounds, it has limitations in identifying odor-active compounds. To resolve this problem, GC-Sniffing or GC-Olfactometry method has been attempted. In this study, GC/FID/Olfactometry system was developed. This system can simultaneously sniff and detect GC effluents by traditional GC combined with human olfactory system. The time gap between FID and ODP response was dependent on the kinds and concentrations of chemicals and panels, with more volatile, stronger and shorten breath cycle panel showing narrow time gap. Thus, clear relationship between FID and ODP should be considered to identify the odor-active compounds.

  • PDF

Release of Ammonia Odor from AAFA (Ammonia Adsorbed Fly Ash) by Installation of NOx Reduction System

  • Kim, Jae-kwan;Park, Seok-un;Lee, Hyun-dong;Chi, Jun-wha
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.3
    • /
    • pp.437-445
    • /
    • 2016
  • This paper discussed the effect of ammonia concentration adsorbed on fly ash for the ammonia emission as AAFA (Ammonia Adsorbed Fly Ash) produced from coal fired plants due to operation of NOx reduction technologies was landfilled with distilled or sea water at closed and open systems, respectively. Ammonia bisulfate and sulfates adsorbed on fly ash is highly water soluble. The pH of ammonium bisulfate and sulfate solution had significant effect on ammonia odor emission. The effect of temperature on ammonia odor emission from mixture was less than pH, the rate of ammonia emission increased with increased temperature when the pH conditions were kept at constant. Since AAFA increases the pH of solution substantially, $NH_3$ in the ash can release the ammonia order unless it is present at low concentration. $NH_4{^+}$ ion is unstable in fly ash and water mixtures of high pH at open system, which is changed to nitrite or nitrate and then released as ammonia gas. The proper conditions for < 20 ppm of ammonia concentration released from the AAFAs landfilled in ash pond were explored using an open system with sea water. It was therefore proposed that optimal operation to collect AAFA of less than 168 ppm ammonia at the electrostatic precipitator were controlled to ammonia slip with less than 5 ppm at SCR/SNCR installations, and, ammonia odor released from mixture of fly ash of 168 ppm ammonia with sea water under open system has about 20 ppm.