• Title/Summary/Keyword: Odor Emission

Search Result 136, Processing Time 0.025 seconds

Evaluation of Air Quality in the Compost Pilot Plant with Livestock Manure by Operation Types (축분 퇴비화시스템 운용방식에 따른 실내 대기오염 평가)

  • Kim, K.Y.;Choi, H.L.;Ko, H.J.;Kim, C.N.
    • Journal of Animal Science and Technology
    • /
    • v.46 no.2
    • /
    • pp.283-294
    • /
    • 2004
  • Air quality in the livestock waste compost pilot plant at the Colligate Livestock Station was assessed to quantity the emissions of aerial contaminants and evaluate the degree of correlation between them for different operation strategies; with the ventilation types and agitation of compost pile, in this study. The parameters analyzed to reflect the level of air quality in the livestock waste compost pilot plant were the gaseous contaminants; ammonia, hydrogen sulfide, and odor concentration, the particulate contaminants; inhalable dust and respirable dust, and the biological contaminants; total airborne bacteria and fungi. The mean concentrations of ammonia, hydrogen sulfide, and odor concentration in the compost pilot plant without agitation were 2.45ppm, 19.96ppb, and 15.8 when it was naturally ventilated, and 7.61ppm, 31.36ppb, and 30.2 when mechanically ventilated. Those with agitation were 5.50ppm, 14.69ppb, and 46.4 when naturally ventilated, and 30.12ppm, 39.91ppb, and 205.5 when mechanically ventilated. The mean concentrations of inhalable and respirable dust in the compost pilot plant without agitation were 368.6${\mu}g$/$m^3$ and 96.0${\mu}g$/$m^3$ with natural ventilation, and 283.9${\mu}g$/$m^3$ and 119.5${\mu}g$/$m^3$ with mechanical ventilation. They were also observed with agitation to 208.7${\mu}g$/$m^3$ and 139.8${\mu}g$/$m^3$ with natural ventilation, and 209.2${\mu}g$/$m^3$ and 131.7${\mu}g$/$m^3$ with mechanical ventilation. Averaged concentrations of total airborne bacteria and fungi in the compost pilot plant without agitation were observed to 28,673cfu/$m^3$ and 22,507cfu/$m^3$ with natural ventilation, and 7,462cfu/$m^3$ and 3,228cfu/$m^3$ with mechanical ventilation. They were also observed with agitation to 19,592cfu/$m^3$ and 26,376cfu/$m^3$ with the natural ventilation, and 18,645cfu/$m^3$ and 24,581cfu/$m^3$ with the mechanical ventilation. It showed that the emission rates of gaseous pollutants, such as ammonia, hydrogen sulfide, and odor concentration, in the compost pilot plant operated with the mechanical ventilation and with the agitation of compost pile were higher than those with the natural ventilation and without the agitation. While the concentrations of inhalable dust and total airborne bacteria in the compost pilot plant with the natural ventilation and with the agitation, the concentrations of respirable dust and total airborne fungi in the compost pilot plant with the mechanical ventilation and agitation were higher than those with the natural ventilation and without the agitation of compost pile. It was statistically proved that indoor temperature and relative humidity affected the release of particulates and biological pollutants, and ammonia and hydrogen sulfide were believed primary malodorous compounds emitted from the compost pilot plant.

Effects of Probiotic Complex on Performance, Blood Biochemical and Immune Parameters, Digestive Enzyme Activity, Fecal Microbial Population and Noxious Gas Emission in Broiler Chicks (복합생균제가 육계의 생산성, 혈액생화학성분과 면역지표, 소화효소 활성도, 분중 미생물 및 유해가스 발생에 미치는 영향)

  • Kim, Min-Jeong;Jeon, Dong-Gyung;Ahn, Ho-Sung;Yoon, Il-Gyu;Moon, Eun-Seo;Lee, Chai-Hyun;Lim, Yong;Jang, In-Surk
    • Korean Journal of Poultry Science
    • /
    • v.47 no.3
    • /
    • pp.169-180
    • /
    • 2020
  • This study examined the effects of a probiotic complex (PC) containing Lactobacillus plantarum, Bacillus subtilis, and Saccharomyces cerevisiae on growth performance, organ weight, immune parameters, fecal microbial count, and noxious odor in broiler chicks. A total of 216 birds (4-day-old) were fed a basal diet (CON) and a diet supplemented with 0.25% (PC1) and 0.5% (PC2) of PC until 35 days of age. No difference in body weight, feed intake, and FCR was observed among the groups. The intestinal mucosal weight of the PC1 group was greater than that of the CON group without affecting weights of the other organs. Intestinal secretory immunoglobulin A (sIgA) levels in the PC2 group increased significantly (P<0.05) compared with that in the CON group. The PC2 group also had a strong tendency for elevated blood sIgA levels. Dietary PC did not affect the level of interleukin-1β in the blood and mucosal tissues or alter maltase, sucrase, and leucine aminopeptidase activities in the intestinal mucosa. The PC2 group had higher colony-forming units (cfu) for L. plantarum and S. cerevisiae, but lower cfu for E. coli than those in the CON group. Compared to the CON diet, the PC2 diet resulted in a decreased H2S concentration and a tendency toward decreased CH3SH concentration. In conclusion, a 0.5% PC diet showed increased sIgA and desirable microbial population, and decreased noxious odor in the feces, suggesting that PC could be applied as an environmentally friendly feed additive in broiler chicks.

Analysis of Nutritional Components, Volatile Properties, and Sensory Attributes of Cynanchi wilfordii Radix: Characterization Study (백하수오의 식품학적 영양 성분 및 휘발성 향기 성분 분석을 통한 관능적 특성 검토)

  • Lim, Ho-Jeong;Kim, Jae-Kyeom;Cho, Kye Man;Joo, Ok Soo;Nam, Sang Hae;Lee, Shin-Woo;Kim, Hyun Joon;Shin, Eui-Cheol
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.44 no.4
    • /
    • pp.564-572
    • /
    • 2015
  • Nutritional compositions, volatile compounds, and sensory attributes of Cynanchi wilfordii Radix were analyzed in order to examine its practical utilization as a food resource. In the proximate analysis, protein and lipid contents were shown to be 14.6 and 5.0 mg/100 g, respectively, in C. wilfordii Radix. Potassium was the most predominant mineral (809 mg/100 g), as determined by inductively coupled plasma-optical emission spectrometry in parallel with microwave acid digestion. Total phenolic content was found to be 410 mg/100 g. Further, arginine and linoleic acid were the most abundant amino acid and fatty acid of C. wilfordii Radix, respectively. To examine its functional properties, classical 2,2-diphenyl-1-picrylhydrazyl (DPPH) analysis was performed. As a result, the concentration of C. wilfordii Radix required to scavenge 50% of DPPH radicals was 1.16 mg of dried material. Lastly, in olfactory and sensory tests, ${\beta}$-eudesmol (woody odor) was the major flavor compound responsible for the bitter taste and sensory attributes of C. wilfordii Radix. Taken altogether, the above results provide important preliminary results for utilization of C. wilfordii Radix as a food resource.

Development of Biofilter for Reducing Offensive Odor from Pig House (돈사 악취 저감을 위한 바이오필터 개발)

  • Lee, Seung-Joo;Lim, Song-Soo;Chang, Dong-Il;Chang, Hong-Hee
    • Korean Journal of Environmental Agriculture
    • /
    • v.24 no.4
    • /
    • pp.386-390
    • /
    • 2005
  • This study was conducted to develop the biofilter fur reducing ammonia $(NH_3)$ and hydrogen sulfide $(H_2S)$ gas emission from a pig house. A biofilter was designed and constructed by a type of squeeze air into the column type of air flow upward. Its column size was ${\Phi}260{\times}360mm$. It was used pressure drop gauge, turbo blower, air temperature, velocity sensor and control program that was programed by LabWindows CVI 5.5. Mixing materials were consisted with composted pine tree bark and perlite with 7:3 ratio (volume). The biofilter media inoculated with ammonia (Rhodococcus equi A3) and hydrogen sulfide (Alcaligenes sp. S5-5.2) oxidizing microorganisms was installed in a commercial pig house to analyzed the effectiveness of biogas removal for 10 days. Removal rates of ammonia and hydrogen sulfide gases were 90.8% and 81.5%, respectively. This result suggests that the pine compost-perlite mixture biofilter is effective and economic for reducing ammonia ana hydrogen sulfide gases.

Estimation on the Contribution of VOCs and Nitric Oxides in Creating Photochemical Ozone (휘발성유기화합물과 질소산화물의 오존생성 기여도 평가에 관한 연구)

  • Cheong, Jang-Pyo;You, Sook-Jin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.2
    • /
    • pp.209-218
    • /
    • 2010
  • The fifty six components of volatile organic compounds(VOCs) were continuously measured by the hour to see the distributions their of its concentration and the ozone creating contribution of nitric oxides and VOCs in Gamjeon Odor and VOCs Monitoring Network from April to September, 2008. Aromatics occupied 51.3% of VOCs and paraffins, alkanes and olefins came in order. The monthly concentration of VOCs in Gamjeon was high in July and low in September. As for hourly concentration of ozone and nitric oxides, ozone started to increase since 10am having the highest in the daytime, and nitric oxides had the different trend from that of ozone, showing the lowest in the daytime. The photochemical ozone creating potentials(POCPs) of toluene, propane, m/p-xylene, ethylbenzene, and 1,2,4-trimethylbenzene were 30.6%, 10.2%, 9.4%, 7.4% and 5.2% respectively. These five components occupied 62.8% of total POCPs, which means they contributed to the ozone creation mainly. Related with the ozone creating contribution, the ratio of VOCs to NOx was generally under 6 occupied 72.0%, which came under the area coexisting the limit of VOCs. Therefore it is thought that the management of emission source of VOCs is very important for the reduction of ozone.

A study on inspection methods for waste treatment facilities(I): Derivation of impact factor and mass·energy balance in waste treatment facilities (폐기물처리시설의 세부검사방법 마련연구(I): 공정별 주요인자 도출 및 물질·에너지수지 산정)

  • Pul-Eip Lee;Eunhye Kwon;Jun-Ik Son;Jun-Gu Kang;Taewan Jeon;Dong-Jin Lee
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.31 no.1
    • /
    • pp.69-84
    • /
    • 2023
  • Despite the continuous installation and regular inspection of waste treatment facilities, complaints about excessive incineration and illegal dumping stench continue to occur at on-site treatment facilities. In addition, field surveys were conducted on the waste treatment facilities currently in operation (6 type) to understand the waste treatment process for each field, to grasp the main operating factors applied to the inspection. In addition, we calculated the material·energy balance for each main process and confirmed the proper operation of the waste disposal facility. As a result of the site survey, in the case of heat treatment facilities such as incineration, cement kilns, and incineration heat recovery facilities, the main factors are maintenance of the temperature of the incinerator required for incineration and treatment of the generated air pollutants, and in the case of landfill facilities Retaining wall stability, closed landfill leachate and emission control emerged as major factors. In the case of sterilization and crushing facilities, the most important factor is whether or not sterilization is possible (apobacterium inspection).In the case of food distribution waste treatment facilities, retention time and odor control during fermentation (digestion, decomposed) are major factors. Calculation results of material balance and energy resin for each waste treatment facility In the case of incineration facilities, it was confirmed that the amount of flooring materials generated is about 14 % and the amount of scattering materials is about 3 % of the amount of waste input, and that the facility is being operated properly. In addition, among foodwaste facilities, in the case of an anaerobic digestion facility, the amount of biogas generated relative to the amount of inflow is about 17 %, and the biogas conversion efficiency is about 81 %, in the case of composting facility, about 11 % composting of the inflow waste was produced, and it was comfirmend that all were properly operated. As a result, in order to improve the inspection method for waste treatment facilities, it is necessary not only to accumulate quantitative standards for detailed inspection methods, but also to collect operational data for one year at the time of regular inspections of each facility, Grasping the flow and judging whether or not the treatment facility is properly operated. It is then determined that the operation and management efficiency of the treatment facility will increase.