• Title/Summary/Keyword: Occupational exposure

Search Result 1,567, Processing Time 0.031 seconds

Comorbid Conditions in Persons Exposed to Ionizing Radiation and Veterans of the Soviet-Afghan War: A Cohort Study in Kazakhstan

  • Saule Sarkulova;Roza Tatayeva;Dinara Urazalina;Ekaterina Ossadchaya;Venera Rakhmetova
    • Journal of Preventive Medicine and Public Health
    • /
    • v.57 no.1
    • /
    • pp.55-64
    • /
    • 2024
  • Objectives: This study investigated the prevalence and characteristics of comorbid conditions in patients exposed to ionizing radiation and those who were involved in the Soviet-Afghan war. Methods: This study analyzed the frequency and spectrum of morbidity and comorbidity in patients over a long-term period (30-35 years) following exposure to ionizing radiation at the Semipalatinsk nuclear test site or the Chornobyl nuclear power plant, and among participants of the Soviet-Afghan war. A cohort study, both prospective and retrospective, was conducted on 675 patients who underwent comprehensive examinations. Results: Numerical data were analyzed using the Statistica 6 program. The results are presented as the mean±standard deviation, median, and interquartile range (25-75th percentiles). The statistical significance of between-group differences was assessed using the Student t-test and Pearson chi-square test. A p-value of less than 0.05 was considered statistically significant. We found a high prevalence of cardiovascular diseases, including hypertension (55.0%) and cardiac ischemia (32.9%); these rates exceeded the average for this age group in the general population. Conclusions: The cumulative impact of causal occupational, environmental, and ultra-high stress factors in the combat zone in participants of the Soviet-Afghan war, along with common conventional factors, contributed to the formation of a specific comorbidity structure. This necessitates a rational approach to identifying early predictors of cardiovascular events and central nervous system disorders, as well as pathognomonic clinical symptoms in this patient cohort. It also underscores the importance of selecting suitable methods and strategies for implementing treatment and prevention measures.

Comparison of Correlation between Total Airborne Bacteria and Particulate Matter in University Spaces (일부 학교 내 총부유세균 및 미세먼지의 상관성 비교)

  • Hyekyung Seo;Harim An
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.34 no.2
    • /
    • pp.115-124
    • /
    • 2024
  • Objectives: The aim of this study is to assess indoor air quality within and around buildings and evaluate the health risks associated with exposure to indoor air pollution. The study compares IAQ standards established by the World Health Organization with those set by South Korea's Ministry of Environment and Ministry of Education. Methods: The study utilized an Anderson Sampler and DustTrakTM II to collect samples of total airborne bacteria and PM in indoor and outdoor environments. Collected samples were analyzed using biological and biochemical methods. Statistical analysis was conducted using SPSS to examine the correlation between airborne bacteria and PM. Results: The study revealed that the concentration of total airborne bacteria in indoor air generally remained below the Ministry of Environment's standard of 800 CFU/m3, although it surpassed this threshold in certain instances. PM concentrations did not exceed the standards. Indoor fine dust concentration was higher when there were people (P<0.05). There was no difference in total floating bacterial concentrations between indoor and outdoor environments (P=0.184). Finally, there was a correlation between fine dust and airborne bacteria concentrations. Conclusion: The study evaluated the concentrations of total airborne bacteria and PM in indoor air, emphasizing the importance of managing IAQ. Further research in various environments is essential to ensure a healthy indoor environment. The findings underscore the need for ongoing research and management to enhance IAQ and create safer and healthier living environments.

Health Perceptions of Police Officers in Korea: An Investigative Study

  • Dongmin Lee;Seohyun Park;Byeong Kwan Woo;Yeon-Cheol Park;Jion Kim
    • Journal of Acupuncture Research
    • /
    • v.41
    • /
    • pp.149-159
    • /
    • 2024
  • Background: Police officers are an occupational group with a high risk of developing musculoskeletal, cardiovascular, and mental diseases because of the nature of their work. This study aimed to gain an understanding of job-related health risks by comparing overall health awareness, presence of physical and mental disabilities and their causes, medical use patterns, and quality of life of the general public through a survey. Methods: In this comparative study, police officer data were collected through a survey conducted from October 1, 2022, to November 15, 2022, and general public data from the 8th National Health and Nutrition Examination Survey of Korea were used for comparison. Results: Police officers' health perception of physical or mental disabilities was significantly more negative than that of the general public because of their work characteristics, patterns, and functions. In addition, police officers with disabilities had severe work and daily living limitations, and their awareness of their overall quality of life was low enough to warrant alarm. Despite their high rates of seeking treatment in medical institutions, continuous medical use was limited. Conclusion: More research on major diseases to which police officers are at risk of exposure is necessary to analyze risk factors and accumulate related data to systematize health management. In addition, Korean medicine treatment techniques with excellent disease prevention are recommended for the health management of police officers.

Real-time Analysis and Safety Assessment of Volatile Organic Compounds Emitted from Masks (마스크에서 방출되는 휘발성유기화합물의 실시간 분석 사례)

  • Hyekyung Seo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.34 no.3
    • /
    • pp.179-188
    • /
    • 2024
  • Objectives: The safety of distributed masks has been widely investigated following the coronavirus disease (COVID-19) pandemic. Although the unpleasant odor from masks is concerning, research on the toxicity of volatile organic compounds emitted from them is limited. Here, we aimed to quantify the VOCs emitted from masks and explore strategies for safe mask usage. Methods: The VOCs emitted from 15 masks in five categories were measured. Proton transfer reaction time-of-flight mass spectrometry (PTR-TOF-MS, IONICON, Austria), which can rapidly and sensitively detect complex mixtures, was conducted. The test chamber connected to the equipment was comprised of uninterrupted acrylic and glass. PTR-TOF-MS data were analyzed using Tofware (PTR-MS Viewer 3.3, IONICON, Austria). Statistical analyses were performed using SPSS ver. 20 to determine the highest, lowest, and average concentrations of the VOCs (IBM SPSS Inc., USA). Analysis of variance (ANOVA) was conducted to compare the VOCs emitted from different masks. Results: A total of 25 VOCs were detected among the 15 masks. The peak concentrations of formaldehyde, acrolein, isoprene, and benzene were higher than the exposure standards (Ceiling). The average concentrations of these compounds differed significantly among the mask samples (p < 0.05). The VOC concentration decreased gradually after approximately one hour. Conclusions: Higher concentrations of VOCs were emitted from healthy, printed, and surgical masks compared to industrial masks. Further research is required to determine the factors affecting VOCs, such as mask material, temperature, and humidity. For safety, masks must be ventilated for at least an hour before usage.

Exposure Assessments of Environmental Contaminants in Ansim Briquette Fuel Complex, Daegu(I) - Effect zone of environmental pneumoconiosis and fugitive dust - (대구 안심연료단지 환경오염물질 노출 평가(I) - 환경성 진폐증 및 비산먼지 영향권역 -)

  • Jung, Jong-Hyeon;Oh, In-Bo;Phee, Young-Gyu;Nam, Mi-Ran;Hwang, Mi-Kyoung;Bang, Jin-Hee;Jeon, Soo-Bin;Lee, Sang-sup;Yu, Seung-do;KimS, Byung-Seok;Yoo, Seok-Ju;Lee, Kwan;Lim, Hyun-Sul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.3
    • /
    • pp.366-379
    • /
    • 2015
  • Objectives: The objective of this study is to assess airborne particulate matter(PM) pollution and its effect on health of residents living near Ansim Briquette Fuel Complex in Daegu metropolitan region. Methods: The California Puff(CALPUFF) dispersion model, version 5.8, which can estimate the dispersion direction and range of airborn $PM_{10}$ was used to determine the possible areas affected by $PM_{10}$ pollutants emitted from Ansim briquette fuel complex. The CALPUFF modeling with 200 m grid-cell resolution was performed based on $PM_{10}$ emissions estimated from the amount of coal consumption in the fuel complex for four months in 2012. The Weather Research and Forecasting(WRF) fields were processed using CALMET to produce CALPUFF-ready meteorological inputs. Also, the distance from Ansim Briquette Fuel Complex to the residence of each environmental pneumoconiosis patient was analyzed. In addition, the affecting region of the pollutants emitted from briquette factories in Ansim Briquette Fuel Complex was determined. Results: CALPUFF modeling results showed that the highest concentrations of $PM_{10}$ were found near around the fuel complex. The modeled $PM_{10}$ distributions were characterized by significant decreases in concentration with distance from the complex. Seasonally, the highest concentration of $45{\mu}g/m^3$ was calculated in October which was mostly due to the distinct variation of amount of emission. Additional modeling with the maximum $PM_{10}$ emission of about 88 tons per year in 1986 showed that the highest concentration in October was nearly increased by 8 times than the concentration modeled with emission of 2010. As a result of medical examination and interviews for the residents in Ansim Briquette Fuel Complex and its surroundings, 8 environmental pneumoconiosis patients were found. These patients do not have occupational exposure and history. These patients have lived 0.3~1.1 km area in Ansim Briquette Fuel Complex and its surroundings. Conclusions: Airborne particles emitted from Ansim Briquette Fuel Complex can contribute to significant increase in $PM_{10}$ concentration in residential areas near around the complex. Especially, the residents near fuel complex may exposed to the pollutants emitted from the factories in Ansim Briquette Fuel Complex.

Study of External Radiation Expose Dose on Hands of Nuclear Medicine Workers (핵의학 종사자에서 손 부위의 외부 피폭선량 연구)

  • Park, Jun-Chul;Pyo, Sung-Jae
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.141-149
    • /
    • 2012
  • The aims of this study are to assess external radiation exposed doses of body and hands of nuclear medicine workers who handle radiation sources, and to measure radiation exposed doses of the hands induced by a whole body bone scan with high frequency and handling a radioactive sources like $^{99m}Tc$-HDP and $^{18}F$-FDG in the PET/CT examination. Skillful workers, who directly dispense and inject from radiation sources, were asked to wear a TLD on the chest and ring finger. Then, radiation exposed dose and duration exposed from daily radiation sources for each section were measured by using a pocket dosimeter for the accumulated external doses and the absorbed dose to the hands. In the survey of four medical institutions in Incheon Metropolitan City, only one of four institutions has a radiation dosimeter for local area like hands. Most of institutions uses radiation shielding devices for the purpose of protecting the body trunk, not local area. Even some institutions were revealed not to use such a shielding device. The exposed doses on the hands of nuclear medicine workers who directly handles radioactive sources were approximately twice as much as those on the body. The radiation exposure level for each section of the whole body bone scan with high frequency and that of the PET/CT examination showed that radiation doses were revealed in decreasing order of synthesis of radioactive medicine and installation to a dispensing container, dispensing, administering and transferring. Furthermore, there were statistically significant differences of radiation exposure doses of the hands before and after wearing a syringe shielder in administration of a radioactive sources. In this study, although it did not reach the permissible effective dose for nuclear medicine, the occupational workers were exposed by relatively higher dose level than the non-occupational workers. Therefore, the workers, who closely exposed to radioactive sources should be in compliance with safety management regulations, and take actions to maximally reduce locally exposed dose to hands monitoring with ring TLD.

Compositions and Contents of Thinner and Reliability of MSDS sold in Busan and Gyeongnam Province (부산,경남에서 판매되는 시너(Thinner)의 구성 성분 중 벤젠 등 일부 독성물질의 함량과 물질안전보건자료에 관한 연구)

  • Kim, Yu Young;Yang, Seung Hyuk;Lee, Jung Sil;Lee, Hyoung Sook;Jang, Kong Hwa;Jin, Koo Won;Lee, Yong Il;Joo, Woo Hong;Paik, Do-Hyeon;Kang, Dae-Ook;Moon, Ja-Young;Cho, Yong-Kweon;Park, Dong Uk;Yoon, Chung Sik;Ha, Kwon Chul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.16 no.4
    • /
    • pp.314-323
    • /
    • 2006
  • This study was conducted to identify ingredients of thinners and to confirm reliability of material safety data sheets (MSDS) of thinners for public and workers' health. The 41 thinner products were collected from paint shops located in Busan and Gyeongnam province. The 12 thinner products among them were identified using product MSDS. GC-MSD was used to analyze 41 kinds of thinners qualitatively and quantitatively. The 12 products MSDS were compared with thinner's component through qualitative analysis to confirm MSDS. Chemical ingredients, such as Benzene, Toluene, and Xylene etc., of thinners were analysed in quantity. The 41 thinner products contained 17 disclosed specific, trade name, or generically described chemical solvent ingredients. These 17 ingredients came under 6 classes: alcohols, aromatic hydrocarbons, esters, glycol ethers, ketones, and mixtures. These 17 ingredients were important in the view of industrial hygiene and had occupational exposure limit in the ambient, such as toluene, xylene, acetone, nonane, EGEE, heptane, cumene, MIBK, indene, tri-methyl benzene, etc, were found in 41 kinds of thinners. Aromatic hydrocarbons were the most identified ingredient in thinners. Especially, the benzene, which induces leukemia, was found in 4 kinds of thinners. The content rates of benzene in thinners were 0.25~1.18%. The benzene in enamel thinner, which were 0.39~0.72%, was highest from chemical classification. The contents of toluene, which was found from 27 kinds of thinners, were 5.35~64.16%, which were highest in sobu thinner as 58.80%. Xylene was found from 22 kinds of thinners and contents of xylene were 4.61~72.42%. Acrylic thinner's contents of xylene were 12.06~51.05%, which was most high. It was found that contents of benzene were increased and frequency of detection was decreased through comparison with other study. The MSDS possession rate of paint shops was low as 29.27%. So it did not provide information with public or workers. Mean of agreement rate between MSDS and components of thinners through qualitative analysis was 42.01% and it has wide range from 8.3% to 75%. There are many deficiencies in MSDS about component of thinners. In some case of sample, expecially, despite containing benzene, information was not written it on MSDS.

Comparison of Sleep Patterns and Autonomic Nervous System Activity among Three Shifts in Shiftworkers (교대근무자에서 각 교대근무간의 수면양상 및 자율신경계 활성도 비교)

  • Yoon, In-Young;Ha, Mi-Na;Park, Jung-Sun;Song, Byoung-Gun
    • Sleep Medicine and Psychophysiology
    • /
    • v.7 no.2
    • /
    • pp.96-101
    • /
    • 2000
  • Objectives: Through comparing sleep variables and autonomic activities among three shifts in shift workers, the authors intended to clarify which shift is most tolerable and to identify the characteristics of their psychological and physical problems. This study is also expected to help shift workers to adapt themselves to their work more effectively. Methods: Fifty one shift workers took part in this study. They were working in a rapidly rotating system in which they worked for 3 days in one shift with one day off between each shift. Based on a sleep diary, sleep latency (SL), sleep period time (SPT), and number of wake after sleep onset (NWASO) were estimated and compared among the three shifts. In assessing sleepiness, Epworth sleepiness scale (ESS) and visual analogue scale (VAS) were used. To evaluate mood states among the three shifts, profile of mood states (POMS) was administered. Heart rate variability (HRV), and the level of adrenaline and noradrenaline were measured to assess autonomic activities. HRV included low frequency power (LF), high frequency power (HF), and LF/HF. Results: SPT was significantly lengthened during the evening shift and SL was shortened during the night shift. The workers showed a drop in alertness at wake-up during morning shift and a drop in alertness at work during night shift. During night shift the subjects complained of physical fatigue and cognitive decline. Comparison of HRV showed that parasympathetic activity was most prominent during the evening shift. Secretion of adrenaline and noradrenaline decreased during the evening shift, though statistically not significant. Conclusion: We found that the evening shift was most tolerable among the three shifts. It is recommended that morning light exposure be done during the morning shift and nocturnal light exposure during the night shift.

  • PDF

Application of Oral Absorption in Establishment of AOEL for Pesticides and Occupational Risk Assessment for farm worker (경구흡수율을 반영한 농약의 AOEL 설정 및 농작업자 위해성 평가)

  • You, Are-Sun;Hong, Soonsung;Lee, Je Bong;Lee, Seungdon;Ihm, Yangbin
    • The Korean Journal of Pesticide Science
    • /
    • v.18 no.4
    • /
    • pp.342-349
    • /
    • 2014
  • Methods of establishment of AOEL (Acceptable Operator Exposure Level), application of oral absorption by country, and calculation of exposure dose for operator risk assessment in USA, EU and Korea were investigated. Oral absorption of 141 active substances for pesticides was also investigated, then operator risk assessment was conducted with AOEL including oral absorption and Korean AOEL. Internal dose converted to external dose with oral or dermal absorption in USA and EU, but external dose to which oral absorption was not applied was used for establishment of AOEL in Korea. Oral absorption of 50 active substances among 141 were below 80%. In case of application of oral absorption as a correction factor in below 80%, AOELs of about 36% active substances were considered to be lower than the current Korean AOELs. Operator risk assessment of 28 active substances among 50 active substances with oral absorption below 80% was conducted with EU AOELs. TER (Toxicity Exposure Ratio) of 12 plant protection products including chlorothalonil WG (Water-dispersible Granule) was less than 1 and the risk was high. Operator risk assessment of 24 active substances among 50 active substances with oral absorption below 80% was conducted with Korean AOELs. TER of 6 plant protection products including chlorothalonil WG were less than 1 and the risk was high. Operator risk assessment of 4 plant protection products not having Korean AOEL was conducted with converted EU AOEL into AOEL not including oral absorption. The results indicated TER of 4 products including daminozide WP (Wettable Powder) was over 1 and risk was low. 22 products except 6 products such as oxadiagyl SC (Suspension Concentration) were shown the same results of risk assessment between EU AOELs and Korean AOELs. As a result, it was considered that AOELs including oral absorption was possible to be used for operator risk assessment. It was considered operator risk assessment with AOEL including oral absorption was more like real assessment method, and improvement of assessment was needed for application to evaluate pesticides in registration.

Design of Ultrasonic Nebulizer for Inhalation Toxicology Study of Cadmium with Application of Engineering Methodology and Performance Evaluation with Light-Scattering Photometer (공학적 기법을 응용한 카드뮴의 흡입독성 연구를 위한 초음파 네뷸라이져의 설계 그리고 광산란 광도계를 이용한 성능평가)

  • Jeung Jae Yeal;Milton Donald K.;Kim Tae Hyeung;Lee Jong Young;Chong Myoung Soo;Ko Kwang Jae;Kim Sang Duck;Kang Sung Ho;Song Young Sun;Lee Ki Nam
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.16 no.3
    • /
    • pp.464-471
    • /
    • 2002
  • Author applied several engineering methodologies to classical ultrasonic nebulizer to cope with it's demerits. After several trials and errors, we got the several meaningful results. To evaluate the modified ultrasonic nebulizer for inhalation toxicology of cadmium, author used light-scattering photometer. This paper is the one part of inhalation exposure systems for inhalation toxicology study of cadmium. According to the testing conditions, source temperature 50℃ and inlet-duct band temperature 150℃, aerosol generation results for sodium chloride and cadmium chloride were as followings: Coefficients of variation(CV) of sodium chloride and cadmium chloride for repeated trials were 3.38 and 4.77 for 10g, 2.47 and 5.02 for 5g, and 4.70 and 2.98 for 2.5g. All the CVs were within 10% of acceptance variability. Count Per Minute(CPM) changes of NaCl and CdCl₂ for 5 repeated trials were similar. CPM ratios of CdCl₂/NaCl were 1.13 for 10g, 0.76 for 5g, and 1.06 for 2.5g. Relative aerosol generation of cadmium chloride to sodium chloride was the highest in 10g. Efficiency increases of 24.50% for 5g NaCl, 14.91 % for 2.5g NaCl, and 16.48% for 2.5g CdCl₂ with respect to theoretical efficiency were observed but 0.04% efficiency decrease was observed in 5g CdC₂. According to the modifications of source temperature(20, 50, 70℃) and inlet-duct band temperature(20, 50, 100, 150, 200℃), aerosol generation results for NaCl and CdCl₂ were as followings: CPM trends for each quantity excepting 10g NaCl in inlet-duct band temperature 200℃ were similar, and the highest CPM was observed in source temperature 70℃ to each inlet-duct band temperature. The highest CPMs to 10, 5, and 2.5g NaCl were observed in source temperature 70℃ and inlet-duct band temperature 20℃. Aerosol generation of cadmium chloride was increased with the higher source temperature, excepting inlet-duct band temperature 200℃. The highest CPMs for 10, 5, and 2.5g CdCl₂ were observed in source temperature 70℃ and inlet-duct band temperature 20℃, and this trend was similar to NaCl aerosol generation The highest CPMs for 10, 5, and 2.5g CdCl₂ were observed in source temperature 70℃ and inlet-duct band temperature 20℃, and this result was similar to NaCl aerosol generation. Observed efficiencies of 5 and 2.5g NaCl were similar to ifs theoretical efficiency but -3.08% efficiency decrease of 5g CdCl₂, 17.47% efficiency increase of 2.5g CdCl₂ were observed. CPM ratio of CdCl₂/NaCl of 10g was different to 5 and 2.5g, and 2.5g ratio was higher than 5g ratio. In conclusion, to get maximum aerosol generation for NaCl and CdCl₂ will be the conditions that set the appropriate inlet-duct band temperature for each materials and increase the source temperature. Sodium chloride can be used to evaluate the performance and predict the concentration for cadmium aerosol in aerosol generator and inhalation exposure system.