• Title/Summary/Keyword: Occupational exposure

Search Result 1,528, Processing Time 0.028 seconds

Bactericidal Efficacy of Non-thermal DBD Plasma on Staphylococcus aureus and Escherichia coli (비열 유전체장벽방전 플라즈마의 포도상구균 및 대장균 살균효과)

  • Kim, Keyyoung;Paik, Namwon;Kim, Yonghee;Yoo, Kwanho
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.28 no.1
    • /
    • pp.61-79
    • /
    • 2018
  • Objectives: The objective of this study was to examine the effect of non-thermal dielectric barrier discharge(DBD) plasma on decontamination of Staphylococcus aureus(S. aureus) and Escherichia coli(E. coli) as common pathogens. Methods: This experiment was carried out in a chamber($0.64m^3$)designed by the authors. The plasma was continuously generated by a non-thermal DBD plasma generator(Model TB-300, Shinyoung Air tech, Korea). Suspensions of S. aureus and E. coli of 0.5 McFarland standard($1.5{\times}10^8CFU/mL$) were prepared using a Densi-Check photometer(bio $M{\acute{e}}rieux$, France). The suspensions were diluted1:1000 in sterile PBS solutions(approximately$10^{4-5}CFU/mL$) and inoculated on tryptic soy agar(TSA) in Petri dishes. The Petri dishes(80mm internal diameter)were exposed to the non -thermal DBD plasma in the chamber. Results: The results showed that 95% of S. aureus colonies were killed after a six-hour exposure to the DBD plasma. In the case of E. coli, it took two hours to kill 100% of the colonies. The gram-negative E. coli had a greater reduction than the gram-positive S. aureus. This difference may be due to the structure of their cell membranes. The thickness of gram-positive bacteria is greater than that of gram-negative bacteria. The S. aureus is more resistant to DBD plasma exposures than is E. coli. It should be noted that average concentrations of ozone, a byproduct of the DBD plasma generator, were monitored throughout the experiment and the results were well below the criteria, 50 ppb, recommended by the Korean Ministry of the Environment. Thus, non-thermal DBD plasma is deemed safe for use in hospital and public facilities. Conclusions: There was evidence that non-thermal DBD plasma can effectively kill S. aureus and E. coli. The results indicate that DBD plasma technology can greatly contribute to the control of infections in hospitals and other public and private facilities.

Evaluation of Lead levels in Airborne by a portable X-Ray Fluorescence Instrument (휴대용 X-Ray 형광기기(XRF)를 이용한 공기중 납농도 평가)

  • Ahn, Kyu Dong;Lee, Jong Chun;Cho, Kwang Sung;Kim, Nam Su;Kim, Jin Ho;Lee, Sung Soo;Lee, Byung Kook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.11 no.3
    • /
    • pp.235-240
    • /
    • 2001
  • This study was performed to compare the lead levels of 20 quality control standard samples(KOSHA:18-2000) and 72 field samples in lead-acid battery manufacturing plant between ICP and portable-XRF methods. 1. While the proficiencies of 20 quality control standard samples by ICP were 100%, those of analytic result values by XRF were 75%. 2. The correlation coefficient(r) between the reference values for quality control (REF) and the analytic result values by ICP (ICP) was 1.0(p<0.05), and simple linear regression equation and the coefficient(R2) were REF = -0.0009 + 1.016 ICP and 0.9997, respectively. 3. The correlation coefficient(r) between the analytic result values of quality control standard samples by ICP (ICP) and by XRF (XRF) was 0.975(p<0.05), and simple linear regression equation and the coefficient(R2) were ICP = -0.0003 + 1.002 XRF and 0.950, respectively. 4. The correlation coefficient(r) between the analytic result values for lead samples of a lead-acid battery manufacturing plant by ICP (ICP) and by XRF (XRF) was 0.993(p<0.05), and simple linear regression equation and the coefficient(R2) were ICP = -2.058 + 0.996 XRF and 0.987, respectively. 5. While the frequency distributions of XRF /ICP(Ratio) for each ICP concentration levels in a lead-acid battery manufacturing plant revealed high proportion in ratio range of 0.876-1.125 than in ration range of 1.126-1.375. Also, ICP concentration level in ration range of 0.786-1.125 was increased with increase of frequency distribution of XRF/ICP. 6. The limit of detection of XRF on lead was determined to be $6.11{\mu}g$/filter The data presented in this study indicated that relationship for lead level of quality control samples and field samples in a lead -acid battery manufacturing plant by ICP and portable-XRF methods was proved. The practicing industrial hygienist can use portable-XRF to produce a rapid on-site determination of lead exposure that can immediately becommunicated to workers and help identify appropriate levels of personal protection.

  • PDF

Smoke Generation by Burning Test of Cypress Plates Treated with Boron Compounds (붕소 화합물로 처리된 편백목재의 연소시험에 의한 연기발생)

  • Chung, Yeong-Jin;Jin, Eui
    • Applied Chemistry for Engineering
    • /
    • v.29 no.6
    • /
    • pp.670-676
    • /
    • 2018
  • Experiments on combustion gases generation of untreated cypress specimens or treated with boric acid, ammonium pentaborate, and boric acid/ammonium pentaborate additive were carried out. Test specimens were painted three times with 15 wt% boron compound aqueous solutions. After drying, the generation of combustion gas was analyzed using a cone calorimeter (ISO 5660-1). As a result, comparing to untreated specimen, the smoke performance index (SPI) of the specimens treated with the boron compound increased by 1.37 to 2.68 times and the smoke growth index (SGI) decreased by 29.4 to 52.9%. The smoke intensity (SI) of the specimens treated with boron compounds is expected to be 1.16 to 3.92 times lower than that of untreated specimens, resulting in lower smoke and fire hazards. Also, the maximum carbon monoxide ($CO_{peak}$) concentration of specimens treated with boron compounds was 12.7 to 30.9% lower than that of untreated specimens. However, it was measured to produce fatal toxicities from 1.52 to 1.92 times higher than that of permissible exposure limits (PEL) by Occupational Safety and Health Administration (OSHA). The boron compounds played a role in reducing carbon monoxide, but it did not meet the expectation of reduction effect because of the high concentration of carbon monoxide in cypress itself.

Skin Absorption of Lawsone in Henna Hair Dye and the Effect of Skin Protectants (헤나염모제 사용 시 로우손의 피부흡수 특성 및 피부보호제의 효과)

  • Kim, Ju Yeon;Kim, Bae-Hwan;Kim, Seung Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.31 no.2
    • /
    • pp.173-183
    • /
    • 2021
  • Objectives: This study evaluated the skin permeability of lawsone in henna hair dyes to understand the exposure characteristics of henna hair dyes in the human body. It examined the protective effects of protectants by applying protectants A, B, and C to test skin. Methods: Skin absorption tests were conducted using Franz diffusion cells according to OECD test guideline 428. After applying one kind of natural henna hair dye and chemical henna hair dye, respectively, to a standardized pig skin model, samples of receptor fluid were collected at 1h, 3h, 6h, and 24h. The skin permeation of lawsone was determined using HPLC. After the skin absorption experiment, the skin to which hair dye was applied was analyzed to determine the residual amount of lawsone in the skin. Results: The cumulative permeation of both natural and chemical henna hair dyes increased over time, and the natural henna hair dye had a flux value (t=3.194, p<.05) high both in the Kp value (t=3.207, p<.05) and the residual amount (t=22.701, p<.001). For skin treated with a protectant, the cumulative permeation of natural henna hair dye 24h control and the cumulative permeation of protectant A, B, and C increased over time. Flux and Kp values were in the order control > protectant A > protectant C > protectant B. The residual amount (F=4.469, p<.05) was in the order of protectant C > protectant A > protectant B > control. At 3h, the dye application time of natural henna hair dye, the lawsone flux value (F=4.454, p<.05) and Kp value (F=4.455, p<.05) were higher in the control group than in the protectant groups. The 24h cumulative permeation of the chemical henna hair dye increased with time in both the control and the protectant groups, and the flux and Kp values were in the order of protectant A > protectant C > protectant B > control. The residual amount (F=7.901, p<.01) was in the order of protectant B > protectant A> protectant C > control. Conclusions: Within the normal dyeing time for henna hair dye (three hours for natural henna hair dyes and 30 minutes for chemical henna hair dyes) lawsone skin penetration was not observed even when no protective agent was applied. After that time, however, evidence of skin penetration and retention of lawsone and the protective effect of protective agents were observed.

Efficacy Evaluation of Disinfectant for Reducing Bioaerosols Generated in a Meat Processing Workplace (육가공 작업장에서 발생되는 바이오에어로졸 저감을 위한 살균제 효능 실증 평가)

  • Hwang, Ju-Young;Choi, Won;Kim, Doo-Young;An, Woo-Ju;Lee, Woo-Je;Kim, Ki-Youn
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.31 no.2
    • /
    • pp.138-146
    • /
    • 2021
  • Objectives: This study aims to compare and evaluate the reduction efficiency of disinfectants used in the domestic meat processing industry to reduce bioaerosol exposure of meat industry workers and to use this as basic data for establishing work environment management measures. Methods: Thirteen disinfectants sold in South Korea were selected for evaluation and the bacterial reduction effect of the disinfectants was investigated. Bacterial suspension and surface disinfection tests were conducted to compare and analyze the antibacterial strength of the disinfectants. Pork carcasses, cutting boards, benches, and conveyor belts were selected for surface sterilization tests. Results: As a result of the bacterial suspension experiment test, all disinfectants had a bacterial reduction efficiency of more than 86%. Among them, the bacterial reduction efficiency of chlorine disinfectants was 99.93% on average. In the results of the pork carcass surface sterilization test, the rate of reduction of disinfectants made of quaternary ammonium compounds (QACs) was the highest. Tests of plastic cutting boards showed that chlorine disinfectants had the best sterilization effect. Experiments on stainless steel benches showed the best bacterial reduction efficiency for chlorine dioxide and QACs disinfectants. In the conveyor belt made of urethane, QACs disinfectants showed excellent sterilization effects. Conclusions: The study evaluated the disinfection power of disinfectants against bacteria occurring in domestic meat processing plants. All disinfectants were found to be effective in bacterial suspension experiments, and chlorine disinfectants were particularly effective. In surface sterilization experiments, sterilizing agents with QACs as the main ingredient were excellent.

The Effect on Attention of College Students by Epidermal Cooling in Posterior and Lateral of Upper Cervix (경추부 후면 및 측면 피부 냉각 작용이 대학생의 주의력에 미치는 영향)

  • Chang, Ji Hong
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.5
    • /
    • pp.328-334
    • /
    • 2022
  • The process that one may consciously focuses on necessary stimulation among tremendous amount of stimulation through human sensory systems is called attention in psychology. It is known that the attention can be affected by many factors such as room temperatures, humidity level, etc. In the field of sports science, ice packs are widely used for recovery from exercise fatigue providing fast heat transfer by conduction. However, the effect on attention by so-called iced-pack-cooling has not been tested. This research focuses on the attention levels when one is provided with a special cooling pad on their dorsal and lateral cervices. 40 subjects were divided into four groups and their attention level was evaluated based on the exposure conditions of combinations in reading and light walking with and without the cooling pad. The Frankfruter Aufmerksamkeits-Inventar, FAIR was used to evaluate the attention levels; the performance index, quality index, and continuity index consist of the FAIR test indicating the selectiveness of the attention, correctness of the attention, and maintaining term of the attention, respectively. Analysis of variance was carried out for those variables and post-hoc if applicable. When visual attention is constantly used for reading and studying, application of conductive heat transfer by the cooling pads is significantly helpful for improvement in selectiveness of the attention and maintaining terms of the attention levels. Also, light walking yielded improvement in selectiveness of the attention and maintaining terms of the attention levels; however one should presupposedly consider the loss of reading time.

Ecological Risk Assessment of 4,4'-Methylenedianiline (4,4'-Methylenedianiline의 환경매체별 위해성평가)

  • Hyun Soo Kim;Daeyeop Lee;Kyung Sook Woo;Si-Eun Yoo;Inhye Lee;Kyunghee Ji;Jungkwan Seo;Hun-Je Jo
    • Journal of Environmental Health Sciences
    • /
    • v.49 no.6
    • /
    • pp.334-343
    • /
    • 2023
  • Background: South Korea's Act on Registration and Evaluation, etc. of Chemicals (known as K-REACH) was established to protect public health and the environment from hazardous chemicals. 4,4'-Methylenedianiline (MDA), which is used as a major intermediate in industrial polymer production and as a vulcanizing agent in South Korea, is classified as a toxic substance under the K-REACH act. Although MDA poses potential ecological risks due to industrial emissions and hazards to aquatic ecosystems, no ecological risk assessment has been conducted. Objectives: The aim of this study is to assess the ecological risk of MDA by identifying the actual exposure status based on the K-REACH act. Methods: Various toxicity data were collected to establish predicted no effect concentrations (PNECs) for water, sediment, and soil. Using the SimpleBox Korea v2.0 model with domestic release statistical data and EU emission factors, predicted environmental concentrations (PECs) were derived for ten sites, each referring to an MDA-using company. Hazard quotient (HQ) was calculated by ratio of the PECs and PNECs to characterize the ecological risk posed by MDA. To validate the results of modeling-based assessment, concentration of MDA was measured using in-site freshwater samples (two to three samples per site). Results: PNECs for water, sediment, and soil were 0.000525 mg/L, 4.36 mg/kg dw, and 0.1 mg/kg dw, respectively. HQ for surface water and sediment at several company sites exceeded 1 due to modeling data showing markedly high PEC in each environmental compartment. However, in the results of validation using in-site surface water samples, MDA was not detected. Conclusions: Through an ecological risk assessment conducted in accordance with the K-REACH act, the risk level of MDA emitted into the environmental compartments in South Korea was found to be low.

Cadmium Concentrations in Environmental Tobacco Smoke of Indoor Environments (실내환경의 환경성담배연기(ETS) 중 카드뮴에 관한 연구)

  • Ha, Kwon Chul;Park, Dong-Uk;Yoon, Chung Sik
    • Analytical Science and Technology
    • /
    • v.16 no.4
    • /
    • pp.299-308
    • /
    • 2003
  • The purpose of this study is to investigate cadmium concentrations among metals in ETS (Environmental Tobacco Smoke) of indoor environments and to evaluate the cadmium as a marker of ETS. The correlations of cadmium concentrations and nicotine, 3-EP, RSP, SD (Smoking Density), and SI (Smoking Index). Air samples of metals, nicotine, 3-EP, and RSP were taken in smoking room, smoking allowed office, corridor outside smoking room, and non-smoking office respectively. The SD, ACH, and SI were investigated during sampling. Airborne concentration of cadmium known as human carcinogen were qualified and quantified. The SD was 0.2 to $2.6cig/m^2{\cdot}hr$, and the mean value of SD in smoking rooms was $1.2cig/m^2{\cdot}hr$ that is higher than other researches. The mean of ACH in smoking rooms was 11.1. The concentrations of cadmium showed log-normal distributions and the geometric mean concentrations of cadmium in smoking rooms, corridor outside smoking rooms, smoking allowed offices, and non-smoking offices were $0.045{\mu}g/m^3$, $0.018{\mu}g/m^3$, $0.021{\mu}g/m^3$, and $0.017{\mu}g/m^3$ respectively. The concentrations of cadmium in smoking room showed significant difference according to category of indoor office environments (p<0.05) and showed compliance with occupational exposure limits. The correlation coefficients between cadmium and nicotine, 3-EP, and RSP were 0.53, 0.41, 0.43 respectively. The cadmium among metals showed the highest correlations (r=0.63) with SI. It was recommended cadmium among metals is a good indicator for ETS.

Lead Pollution and Lead Poisoning among Children in China

  • Zheng, Yuxin
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2003.06a
    • /
    • pp.24-25
    • /
    • 2003
  • Lead is ubiquitous in the human environment as a result of industrialization. China's rapid industrialization and traffic growth have increased the potential for lead emissions. Lead poisoning in children is one of the most common public health problems today, and it is entirely preventable. Children are more vulnerable to lead pollution and lead in their bodies can affect their nervous, circulatory, and digestive systems. Children are exposed to lead from different sources (such as paint, gasoline, and solder) and through different pathways (such as air, food, water, dust, and soil). Although all children are exposed to some lead from food, air, dust, and soil, some children are exposed to high dose sources of lead. Significant sources of lead for China's children include industrial emissions (often close to housing and schools), leaded gasoline, and occupational exposure that occurs when parents wear lead-contaminated clothing home from work, burning of coal for home heat and cooking, contaminated food, and some traditional medicines. To assess the blood lead level in children in China, a large-scale study was conducted in 19 cities among 9 provinces during 1997 to 2000. There were 6502 children, aged 3-5 years, were recruited in the study The result indicates that the mean blood lead level was 8.83ug/dl 3-5 year old living in city area. The mean blood lead level of boys was higher than that of girls (9.1l ug/dl vs 8.73ug/dl). Almost 30 percent childrens blood lead level exceeded 10ug/dl. The average blood lead level was higher than that of in 1985 (8.83ug/dl vs 8.lug/dl). An epidemiological study was carried on the children living around the cottage industries recycling the lead from battery. Nine hundreds fifty nine children, aged 5-12 years, living in lead polluted villages where the lead smelters located near the residential area and 207 control children live in unpolluted area were recruited in the study. The lead levels in air, soil, drinking water and crops were measured. The blood lead and ZnPP level were tested for all subjects. The results show that the local environment was polluted. The lead levels both in the air and crops were much higher than that of in control area. In the polluted area, the average blood level was 49.6ug/dl (rang 19.5-89.3ug/dl). Whereas, in the unpolluted area, the average blood level was 12.4ug/dl (rang 4.6-24.8ug/dl). This study indicates that in some countryside area, some cottage industries induce seriously lead pollution and cause children health problem. For the introducing of unleaded gasoline in some large cities, such as Beijing and Shanghai, the blood lead level showed a declined trend since 1997. By 2000, the use of leaded gasoline in motor vehicles has been prohibited in China. The most recent data available show that levels of lead in blood among children in Shanghai decreased from 8.3ug/dl in 1997 to 7.6ug/dl in 1999. The prevalence rate of children lead poisoning (blood lead >10ug/dl) was also decreased from 37.8% to 24.8%. In children living in downtown area, the blood lead level reduced dramatically. To explore the relationship between gene polymorphisms and individual susceptibility of lead poisoning, a molecular epidemiological study was conducted among children living in lead polluted environment. The result showed that the subjects with ALAD2 allele has higher ZPP level, and the subjects with VDR B allele has larger head circumference than only with b allele. In the present study, we demonstrated that ALAD genotypes modify lead effects on heme metabolism and VDR gene variants influence the skull development in highly exposed children. The polymorphism of ALAD and VDR genes might be the molecular inherited factor modifying the susceptibility of lead poisoning. Recently, Chinese government pays more attention to lead pollution and lead poisoning in children problem. The leaded gasoline was prohibited used in motor vehicles since 2000. The government has decided to have a clampdown on the high-polluted lead smelters for recycling the lead from battery in countryside. It is hopeful that the risk of lead poisoning in children will be decreased in the further

  • PDF

Clinical Characteristics of Diffuse Panbronchiolitis (미만성 범세기관지염의 임상상에 관한 연구)

  • Kim, Young-Whan;Yoo, Chul-Gyu;Han, Sung-Koo;Shim, Young-Soo;Kim, Keun-Youl;Han, Yong-Chol
    • Tuberculosis and Respiratory Diseases
    • /
    • v.39 no.1
    • /
    • pp.28-34
    • /
    • 1992
  • Background: Diffuse panbronchiolitis (DPB) is a chronic obstructive pulmonary disease distinguished from bronchial asthma, chronic bronchitis, pulmonary emphysema, bronchiectasis, or alveolitis. It is prevalent in Japan, but is known to be rare outside of Japan. Only a few cases in Chinese, Italian, Noirth American and Korean have been reported. During recent two years we have found 16 cases of DPB in Seoul National University Hospital and analyzed the clinical characteristics. Method: We reviewed the patients' age, sex, duration of illness, smoking history, occupational history and past medical history. And we analyzed patients' symptoms, physical signs, laboratory findings and responses to treatment. Results: 1) Male: female ratio was 2.2:1, the ages ranged from 27 to 72 years old, and the duration of disease varied from 1 to 20 years. 2) Most of the patients were being treated as bronchiectasis, miliary tuberculosis, chronic bronchitis or bronchial asthma before they were diagnosed as DPB. 3) Only one patient was a smoker, and 25% of patients had the occupational history of exposure to particles or gas. And all patients had paranasal sinusitis. 4) High resolution computed tomography (HRCT) was very useful in diagnosing the disease in most of the patients. 5) PFT showed obstructive and restrictive abnormalities, and blood gas revealed hypoxemia in most of the patients. 6) Pseudomonas aeruginosa was isolated in the sputum of four patients (25%). 7) The titers of cold hemaglutinin, RA factor and CRP were elevated in most of the patients. 8) Most of the patients improved after treatment with erythromycin. Conclusion: DPB might not be a rare disease in Korea. So DPB should be suspected in a patient who has chronic cough, sputum, dyspnea and diffuse fine nodular chest X-ray abnormality. HRCT and open lung biopsy should be considered in a patient suspected of DPB.

  • PDF