검색결과 122건 처리시간 0.02초

방사선취급 병원근무자들의 염색체이상 및 자매염색분체교환 빈도 (Chromosome Aberrations and Sister Chromatid Exchanges of Hospital Workers Exposed to Radiation)

  • 차애리;김미선;황인경;이수일;조병만;김돈균
    • Journal of Preventive Medicine and Public Health
    • /
    • 제31권4호
    • /
    • pp.616-627
    • /
    • 1998
  • In order to evaluate the cytogenetic hazard among hospital workers potentially exposed to low dose of radiation, the analysis of chromosome aberrations(CA) and sister chromatid exchanges(SCE) in lymphocytes were performed in 79 hospital workers and 79 non-exposed workers. The mean frequency of chromosomal exchange and deletion(respectively, $0.20\times10^{-2}/cell\;and\;0.39\times10^{-2}/cell$) in the exposed group were significantly higher than those$(0.07\times10^{-2}/cell\;and\;0.23\times10^{-2}/cell)$ in control group. The frequency of sister chromatid exchanges was 5.04/cell in the control vs. 6.57/cell in the exposed group. There were also significant differences in the mean frequencies of CA and SCE adjusted for age, sex, smoking, drinking between two groups. There were no evidence of significant increase of CA and SCE according to the department or duration of employment. But the frequency of cells having chromosome aberration was significantly higher in the exposed group than in the control group related to duration of employment. There was no dose-effect relationship between the cumulative doses and the frequency of CA and SCE. But in the case of last 1 yr cumulative dose, there were evidence of significant dose-dependant increase of chromosome type CA and percentage of cells with aberration. The result suggest that there is cytogenetic hazard in risk group like hospital workers handling low dose radiation. And the analysis CA and SCE are useful biological indicators for the exposure of low dose level of radiation.

  • PDF

DL-RRT* algorithm for least dose path Re-planning in dynamic radioactive environments

  • Chao, Nan;Liu, Yong-kuo;Xia, Hong;Peng, Min-jun;Ayodeji, Abiodun
    • Nuclear Engineering and Technology
    • /
    • 제51권3호
    • /
    • pp.825-836
    • /
    • 2019
  • One of the most challenging safety precautions for workers in dynamic, radioactive environments is avoiding radiation sources and sustaining low exposure. This paper presents a sampling-based algorithm, DL-RRT*, for minimum dose walk-path re-planning in radioactive environments, expedient for occupational workers in nuclear facilities to avoid unnecessary radiation exposure. The method combines the principle of random tree star ($RRT^*$) and $D^*$ Lite, and uses the expansion strength of grid search strategy from $D^*$ Lite to quickly find a high-quality initial path to accelerate convergence rate in $RRT^*$. The algorithm inherits probabilistic completeness and asymptotic optimality from $RRT^*$ to refine the existing paths continually by sampling the search-graph obtained from the grid search process. It can not only be applied to continuous cost spaces, but also make full use of the last planning information to avoid global re-planning, so as to improve the efficiency of path planning in frequently changing environments. The effectiveness and superiority of the proposed method was verified by simulating radiation field under varying obstacles and radioactive environments, and the results were compared with $RRT^*$ algorithm output.

직업인 전자파 노출 평가제도 연구 (Investigation of Occupational EMF Exposure Assessment System)

  • 전상봉;이애경;권용기;장주동;안준오;백정기;김윤명;최형도
    • 한국전자파학회논문지
    • /
    • 제28권11호
    • /
    • pp.843-852
    • /
    • 2017
  • 최근 WHO IARC에서 무선주파수 전자파를 발암 유발 가능 물질(2B 등급)으로 분류함에 따라 전자파로부터의 과다노출로 인한 건강 영향에 대한 우려가 증가하고 있다. 특히 직업인의 경우는 일반인에 비해 전자파에 더 많이 노출될 수밖에 없는 환경에서 근무하게 된다. 이로 인해 유럽에서는 직업인에 대한 전자파 인체보호를 위한 지침을 마련하여 직업인에 대해 엄격히 관리하고 있다. 본 논문에서는 EU의 직업인 보호 관련 법령, 표준 및 지침을 분석하고, 또한 실제 아크용접에 대한 직업인 전자파 노출 평가를 수행하였다. 이를 토대로 직업인 보호를 위한 국내 제도 도입 방안을 제시하였다.

A preliminary evaluation of the implementation of a radiation protection program for the lens of the eye in Korean nuclear power plants

  • Kong, Tae Young;Kim, Si Young;Cho, Moonhyung;Jung, Yoonhee;Son, Jung Kwon;Jang, Han;Kim, Hee Geun
    • Nuclear Engineering and Technology
    • /
    • 제53권9호
    • /
    • pp.3035-3043
    • /
    • 2021
  • Epidemiological research has revealed that radiation exposure can cause cataracts. The Korean nuclear regulatory body has proposed the reduction of the occupational dose limit for the lens of the eye from 150 mSv/y to 100 mSv/5y, with an additional limitation of not exceeding 50 mSv/y for a specific year, taking into account the recommendations of the International Commission on Radiological Protection, and the International Atomic Energy Agency. This means that radiation workers should receive the same level of radiation safety for the lens of the eye as for whole-body protection. Korean nuclear power plants (NPPs) are conducting research to establish the radiation protection program for the lens of the eye. In terms of the preliminary results of the implementation of the radiation protection program for the lens of the eye dedicated to Korean NPPs, this review article summarizes the current state of understanding of the regulations, technical guidance, eye lens dosimeters, and radiation field conditions resulting in lens dose.

18FDG 합성시 핫셀장비 외부로 유출 방사선의 선량 평가 (Evaluation of the Radiation Dosage Flowing out of the Hot Cell During Synthesis of 18FDG)

  • 정홍문;정재은;조준호;원도연
    • 한국방사선학회논문지
    • /
    • 제7권5호
    • /
    • pp.365-369
    • /
    • 2013
  • PET(positron emission tomography)을 촬영하기 위해서는 방사선 의약품 동위원소를 사용하여 인체 내에 정맥주사를 한다. 이 경우 대표적으로 사용하는 방사선 의약품은 $^{18}FDG$ (Fluorodeoxyglucose)이다. 의료용 싸이크로트론으로 생산하는 $^{18}F$에 deoxyglucose를 합성하기 위해서 합성용 카세트장치가 필요하다. 방사성 의약품 제조시에는 많은 양의 2차 방사선이 발생이 된다. 따라서 2차 방사선을 차폐하기 위하여 핫셀(Hot cell)을 사용한다. 우리는 $^{18}FDG$ 합성 또는 분배시에 핫 셀 외부로 유출되는 선량을 측정하였다. 이번 실험은 $^{18}FDG$ 제조 작업시에 의도하지 않게 발생할 수 있는 방사선 작업종사자의 피폭에 관한 선량정보를 제공하기 위함이다. 결론적으로 핫셀 내부에서 외부로 $^{18}FDG$ 합성시에 선량이 유출됨을 확인 할 수 있었다. 특히 핫셀에서 핫셀 내부를 볼 수 있는 납유리에서 외부로 방사선이 유출되는 것을 알 수 있었다. 결론적으로 $^{18}FDG$ 합성시 방사선 작업종사자의 피폭선량을 감소하기 위해서는 핫셀 존재하는 납유리의 개선점이 필요할 것으로 사료된다.

국내원전 액체방사성폐기물계통 설계경험

  • 이병식;김길정
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2003년도 가을 학술논문집
    • /
    • pp.43-47
    • /
    • 2003
  • The performance of the Radwaste System is measured in terms of generation of waste volumes, the release of radioactive materials to the environment and the occupational radiation exposure to workers. Based on our design and operating experience from PWR plants, various design goals for liquid radwaste system were developed to improve system performance. It has been making continuous effort to develop the advanced liquid radwaste processing technology for new PWR plants since 1998. The primary goal of this effort was to obtain better performance and to design a more economical liquid radwaste system. This paper describes lesson learned experience from design of the liquid radwaste system in Korea Nuclear Power Plants.

  • PDF

진단방사선 및 핵의학 검사에 의한 한국인의 의료상 피폭 (Medical Exposure of Korean by Diagnostic Radiology and Nuclear Medicine Examinations)

  • 권정완;정제호;장기원;이재기
    • Journal of Radiation Protection and Research
    • /
    • 제30권4호
    • /
    • pp.185-196
    • /
    • 2005
  • 의료 목적으로 X선 촬영이나 CT, PET과 같은 진단방사선 피폭은 불가피하지만 선진국에서 의료 방사선이 최대의 인공 피폭원을 구성하고 있고 또 빠르게 증가하는 경향에 있음을 고려하면 의료상 피폭의 특성이나 그 결과로 인한 환자 선량 크기를 이해하는 것은 매우 중요하다. 이에 2002년도를 기준으로 단위 진료행위별 선량과 국내 의료보험 통계자료를 결합하여 방사선 진료절차별 집단선량과 1인당 유효선량 평가하였다. 절차의 유효선량 값은 NRPB 보고서, ICRP 80, MIRDOSE3.1 및 우리가 독립적으로 산출한 자료들로부터 편집하였다. 평가 결과 연간 집단선량은 진단방사선 22880man-Sv, 핵의학 4560man-Sv로서 총 27440 man-Sv로 나타났으며 따라서 인구 4770만 명을 나눈 1인당 연평균 의료상 피폭선량은 0.58mSv였다. 이 집단선량은 2002년 16기의 원전을 가동한 우리나라의 직업상피폭 70man-Sv보다 크게 많다. 특히 CT 촬영만의 집단선량도 9960man-Sv에 이름은 주목할 일이다. 이 결과는 국가의 방사선방호 정책이 의료에서 환자선량 최적화에 보다 주목해야 함을 시사한다.

방사성 의약품 자동 분주장치의 유용성 및 최적화된 분주방법에 관한 고찰 (A Study on the Usefulness of Auto Dispenser and Optimized Dispensing Method)

  • 이정은;김호성;류재광;정우영
    • 핵의학기술
    • /
    • 제17권2호
    • /
    • pp.59-66
    • /
    • 2013
  • 최근 방사선 작업종사자의 외부피폭을 감소시키기 위하여 방사성 의약품 자동 분주장치를 사용하는 병원이 증가하는 추세이다. 방사성 의약품 자동 분주장치는 주사기의 피스톤을 잡아당기는 거리(mm)를 조절하여 방사성 의약품을 자동 분주 하도록 설계되어 있어 장비에 장착한 바이알 내 방사성 의약품의 비방사능이 클 때 소량의 원하는 단위 방사능의 방사성 의약품을 분주하기 어렵다. 따라서 본 연구에서는 방사성 의약품 자동 분주장치의 방사능 차폐능력을 평가하고 장비의 분주 재현성을 극대화하는 최적화된 분주방법을 찾고자 세 가지 실험을 진행하였다. 첫 번째 실험은 자동 분주장치의 사용여부에 따른 방사선 작업종사자의 손과 흉부의 피폭 비교 실험이다. 환자에게 $^{18}F-FDG$ 투여 시 30명은 자동 분주로, 30명은 수동으로 분주하여 투여하고 주사과정에서 방사선 작업종사자가 받는 손과 흉부의 피폭선량을 측정하여 비교하였다. 흉부 피폭선량은 독립표본 t-검정 결과, 분주방법에 따라 유의한 차이가 있었고 손의 피폭선량은 자동 분주 시 오른손 검지에서 11.5배 왼손 검지에서 4.8배 낮게 측정되었다. 두 번째 실험은 자동 분주장치의 분주 용량 재현성 평가이다. 생리식염수가 담긴 바이알을 장비에 장착하고 분주하고자 하는 용량을 1부터 15 mm까지 1 mm씩 증가시키면서 5회씩 분주하였을 때 주사기의 무게를 뺀 분주된 생리식염수만의 무게를 마이크로 저울로 측정하여 표준편차와 변동계수를 비교하였다. 그 결과, 표준편차는 분주하고자 하는 용량의 크기가 커짐에 따라 불규칙하게 나타났지만 변동계수는 감소하는 추세를 나타냈다. 또한 작은 크기의 주사기를 사용하였을 때 더 낮은 표준편차와 변동계수를 나타냈다. 세 번째 실험은 자동 분주장치의 분주 방사능 재현성 평가이다. 장비에 장착된 바이알 내 $^{18}F-FDG$의 비방사능이 다를 때 70 kg 환자를 기준으로 kg당 5.17 MBq (0.14 mCi)인 362.6 MBq (9.8 mCi)${\pm}10%$를 분주 후 동일 용량에서 4회 더 분주 하여 dose calibrator에서 방사능을 측정하고 그 표준편차와 변동계수를 비교 분석하였다. 그 결과, 장비에 장착된 바이알 내 $^{18}F-FDG$의 비방사능이 증가할수록 표준편차와 변동계수 모 두 증가하는 추세를 보였으며 작은 크기의 주사기를 사용할 때 더 낮은 편차를 보였다. 또한 바이알 내 $^{18}F-FDG$의 비방사능이 2 mL 주사기를 사용할 때에는 약 1,020 MBq/mL (27.6 mCi/mL) 이하, 5 mL 주사기를 사용할 때에는 약 915 MBq/mL (24.7 mCi/mL) 이하일 때 변동계수를 10% 미만으로 유지시키며 더욱 유용하게 사용할 수 있음을 확인하였다.

  • PDF

Use of Rank Sum Method in Identifying High Occupational Dose Jobs for ALARA Implementation

  • Cho, Yeong-Ho;Kang, Chang-Sun
    • Nuclear Engineering and Technology
    • /
    • 제30권5호
    • /
    • pp.444-451
    • /
    • 1998
  • The cost-effective reduction of occupational radiation exposure (ORE) dose at a nuclear power plant could not be achieved without going through an extensive analysis of accumulated ORE dose data of existing plants. It is necessary to identify what are high ORE jobs for ALARA implementation. In this study, the Rank Sum Method (RSM) is used in identifying high ORE jobs. As a case study, the database of ORE-related maintenance and repair jobs for Kori Units 3 and 4 is used for assessment, and top twenty high ORE jobs are identified. The results are also verified and validated using the Friedman test, and RSM is found to be a very efficient way of analyzing the data.

  • PDF

Development of Moving Alternating Magnetic Filter Using Permanent Magnet for Removal of Radioactive Corrosion Product from Nuclear Power Plant

  • M. C. Song;Kim, S. I.;Lee, K. J.
    • Nuclear Engineering and Technology
    • /
    • 제34권5호
    • /
    • pp.494-501
    • /
    • 2002
  • Radioactive Corrosion Products (CRUD) which are generated by the neutron activation of general corrosion products at the nuclear power plant are the major source of occupational radiation exposure. Most of the CRUD has a characteristic of showing strong ferrimagnetisms. Along with the new development and production of permanent magnet (rare earth magnet) which generates much stronger magnetic field than the conventional magnet, new type of magnetic filter that can separate CRUD efficiently and eventually reduce radiation exposure of personnel at nuclear power plant is suggested. This separator consists of inner and outer magnet assemblies, coolant channel and container surrounding the outer magnet assembly. The rotational motion of the inner and outer permanent magnet assemblies surrounding the coolant channel by driving motor system produces moving alternating magnetic fields in the coolant channel. The CRUD can be separated from the coolant by the moving alternating magnetic field. This study describes the results of preliminary experiment performed with the different flow rates of coolant and rotation velocities of magnet assemblies. This new magnetic filter shows better performance results of filtering the magnetite at coolant (water). How rates, rotating velocities of magnet assemblies and particle sizes turn out to be very important design parameters.