• 제목/요약/키워드: Occupational Radiation Exposure

검색결과 116건 처리시간 0.028초

치과종사자들의 방사선 안전관리에 대한 지식 및 행태 (The Knowledge, Attentions and Behaviors of Radiation Safety Managment by Dental Health care Workers)

  • 이선미;김민지
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권6호
    • /
    • pp.469-476
    • /
    • 2019
  • The purpose of this study examines the education, knowledge and behavior of radiation safety management among dental workers and compares the education, knowledge and behavior between dental hygienist group and other occupational groups. This study was conducted from November 2nd to November14th, 2019. The survey was conducted on dental workers(dental hygienists, nursing, assistants, coordinators, etc.) who worked in dental hospitals and clinics in Busan area. The tool of this study was modified and adapted to the clinical setting based on the questionnaire. Radiation safety education has 39 dental hygienists who had more education than non-dental hygienists (p=0.286). The most common types of radiation safety education were self-education which usually performed by dentistry, followed by conservative education and others. The average of radiation attitudes, knowledge and behaviors was higher in the dental hygienist group then in the non-dental hygienist group. On the item-specific behavior among employees, the question of 'the radiation should be shielded according to the menstrual cycle or pregnancy of the woman of childbearing' was significant (p<0.05). On the item-specific knowledge between occupations, the question of 'the intensity of X-rays decreases over distance' and 'the individual exposure can be measured by TLD badge or film badge' was significant (p<0.05). Taken together, these results indicate that the dental hygienist group is more concerned about radiation safety and that the dental hygienist group is receiving more radiation safety management training. However, if there is a low level of 'has experienced' in the presence or absence of safety management education, it is difficult to train radiation safety management in dentistry. Therefore, it is considered that dentists should be trained in radiation safety management periodically to pay attention to radiation safety accidents.

운항승무원의 우주방사선 피폭 평가에 있어 누적형 개인 중성자 선량계의 적용가능성 예비 연구 (Preliminary Study on Applicability of Accumulate Personal Neutron Dosimeter for Cosmic-ray Exposure of Aviators)

  • 김형진;장병욱;변종인;송명한;김정호
    • Journal of Radiation Protection and Research
    • /
    • 제38권1호
    • /
    • pp.44-51
    • /
    • 2013
  • 상대적으로 높은 항공승무원의 우주방사선 피폭을 고려하여 ICRP는 직무피폭의 일부로 간주하고 방사선 방호 대상으로 권고하였으며 이미 유럽 등 일부 국가에서는 항공 고도에서의 항공승무원에 대한 우주방사선 피폭 관리가 이루어지고 있다. 국내에서도 2012년 7월 26일 생활주변방사선안전관리법의 시행과 더불어 항공승무원에 대한 관리 기준이 마련되었다. 본 연구에서는 항공승무원의 개인 선량 평가에서 휴대가 용이한 누적형 고체비적검출기의 적용가능성을 검토하기 위해 수행되었다. 한국표준과학연구원에서 $^{252}Cf$ 중성자 표준 선원을 이용해 선량계의 중성자 선량에 대한 반응도의 선형성과 중성자 입사각에 따른 각도의존성을 평가하였고 한국민간항공조종사협회의 협조를 얻어 항공 고도에 선량계를 노출시켰다. 응답 특성 평가 결과, 선형성에서는 각각의 감속재에 대해 모두 상관계수($r^2$)가 0.99 이상으로 높았고 큰 각도의존성을 나타내었다. 또한 예측된 운항 승무원의 중성자 선량과 비적 밀도와의 상관성은 각각의 감속재에 대하여 r=0.486 (HDPE), r=0.241 (PA)으로 낮게 평가되었다. 누적형 중성자 선량계는 개인 피폭 선량 평가에 활용 가능성이 있을 것으로 판단되나 항공 고도에서의 중성자 에너지 스펙트럼을 고려하여 추가적인 연구가 필요하며 노출 시간을 증가시켜 비적 밀도와의 상관성을 보다 면밀하게 평가할 필요가 있다.

환자 이송원의 피폭선량 측정 (A Measurement of Exposure Dose for Patient Transporter)

  • 송채림;이왕희;안성민
    • 한국방사선학회논문지
    • /
    • 제13권3호
    • /
    • pp.433-438
    • /
    • 2019
  • 의료기관에서는 환자의 진단 및 치료를 위해 방사선발생장치 및 방사성동위원소를 사용하고 있다. 환자이송원은 환자이송을 위해 불가피하게 방사선 관리구역에 출입하거나, 동위원소가 투여된 환자를 근거리에서 이송하는 등 일반인과 비교했을 때, 방사선에 노출될 확률이 높은 환경에서 업무를 수행한다. 따라서 환자이송원의 피폭 정도를 알아보고자 연구를 진행했다. 인천 A 종합병원에서 근무하고 있는 12명의 환자이송원을 대상으로 2019년 4월 1일부터 4월 30일까지 한 달 동안 선량계를 가슴에 패용하고, 누적된 선량을 측정했다. 사용된 선량계는 광자극발광선량계(OSLD), 선량판독은 OSLD Microstar Reading System을 사용했다. 한 달 동안 누적선량 측정 결과 심부선량은 평균 0.13 mSv, 표층선량은 평균 0.13 mSv로 측정되었고, 한 달 동안 누적된 선량에 12를 곱해 일 년 동안 업무를 수행할 시 받게 될 누적선량 예상치를 추정한 결과 심부선량은 평균 1.52 mSv, 표층선량은 평균 1.51 mSv로 나타났다. 환자이송원의 수시출입자 분류를 통해 피폭선량을 측정, 관리 하고, 교육훈련을 통해 방사선에 대한 방호지식을 높이며 건강진단을 통해 방사선장해 발생을 방지하기 위한 노력이 필요하다.

Novel Dosimeter for Low-Dose Radiation Using Escherichia coli PQ37

  • Park, Seo-Hyoung;Kim, Tae-Hwan;Cho, Chul-Koo;Lee, Yeon-Hee
    • Journal of Microbiology and Biotechnology
    • /
    • 제11권3호
    • /
    • pp.524-528
    • /
    • 2001
  • The measurement of radiation response using simple and informative techniques would be of great value in studying the genetic risk following occupational, therapeutic, or accidental exposure to radiation. When patients receive radiation therapy, many suffer from side effects. Since each patient receives a different dose due to different physical conditions, it is important to measure the exact dose of radiation received by each patient to lessen the side effects. Even though several biological dosimetric systems have already been developed, there is no ideal system that can satisfy all the criteria for an idean dosimetric system, especially for low-dose radiation as used in radiation therapy. In this study, an SOS Chromotest of E. coli PQ37 was evaluated as a novel dosimeter for low-dose gamma-rays. E. coli PQ37 was originally developed to screen chemical mutagens using the SOS Chromotest-a colorimtric assay, based on the induction of ${\beta}$-galactosidase ue to DNA damage. The survival fraction of E. coli PQ37 decreased dose-dependently with an increasing dose of cobalt-60 gamma-rays. Also, a good linear correlation was found between the biological damage revealed by the ${\beta}$-galactosidase expression and the doses of gamma-rays. The expression of ${\beta}$-galactosidase activity that responded to low-dose radiation under 1 Gy was $Y=0.404+(0.089{\pm}0.3)D+(-0.018{\pm}0.16)D^2$ (Y, absorbance at 420 nm; D, Dose of irradiation) as calculated using Graph Pad In Plot and Excel. When a rabbit was fed with capsules containing an agar block embdded with E. coli PQ37 showed a linear response to the radiation doses. Accordingly, the results confirm that E. coli PQ37 can be used as a sensitive biological dosimeter fro cobalt-60 gamma-rays. To the best of our knowledge, this is the first time that a bacterium has been used as a biological dosimeter, especially for low-dose radiation.

  • PDF

다중소자 열형광선량계에 의한 수정체 등가선량 평가의 적정성 연구 (A Feasibility Study on the Lens of Eye Dose Assessment Using the System of Multi-Element TLD)

  • 이나래;한승재;이병일;조건우
    • Journal of Radiation Protection and Research
    • /
    • 제37권2호
    • /
    • pp.96-102
    • /
    • 2012
  • 2011년 국제방사선방호위원회(ICRP)는 최근 역학 조사들을 근거로 방사선영향으로 발생할 수 있는 암 외 질환의 위험에 대한 권고를 개정하였다. 특히 수정체 조직반응의 발단선량을 0.5 Gy로 하향 조정하면서, 계획 피폭상황에서 직무 피폭 시 수정체 등가선량한도를 "정해진 5년 기간 동안 평균해서 연간 20 mSv, 그 중 어느 한 해에도 50 mSv를 초과하지 않아야 한다"로 권고하였다. 방사선작업종사자의 외부선량은 개인 열형광선량계(TLD)를 사용하여 감시하고 있으며 판독한 열형광소자별 반응도를 선량평가 알고리즘에 적용하면 개인의 수정체 등가선량을 구할 수 있다. 본 논문에서는 성능검사에 사용된 Harshaw TLD의 소자반응도를 사용하여 현재 사용 중인 알고리즘들에 의한 수정체 등가선량을 평가하였다. 그 결과 성능검사에 사용된 TLD의 소자반응도를 사용하여 수정체 등가선량을 평가한 경우 알고리즘 간의 상대오차는 최대 48.84% 내에 있는 것으로 나타났다.

The Japan Health Physics Society Guideline on Dose Monitoring for the Lens of the Eye

  • Yokoyama, Sumi;Tsujimura, Norio;Hashimoto, Makoto;Yoshitomi, Hiroshi;Kato, Masahiro;Kurosawa, Tadahiro;Tatsuzaki, Hideo;Sekiguchi, Hiroshi;Koguchi, Yasuhiro;Ono, Koji;Akiyoshi, Masahumi;Kunugita, Naoki;Natsuhori, Masahiro;Natsume, Yoshinori;Nabatame, Kuniaki;Kawashima, Tsunenori;Takagi, Shunji;Ohno, Kazuko;Iwai, Satoshi
    • Journal of Radiation Protection and Research
    • /
    • 제47권1호
    • /
    • pp.1-7
    • /
    • 2022
  • Background: In Japan, new regulations that revise the dose limit for the lens of the eye (hereafter the lens), operational quantities, and measurement positions for the lens dose were enforced in April 2021. Based on the international safety standards, national guidelines, the results of the Radiation Safety Research Promotion Fund of the Nuclear Regulation Authority, and other studies, the Working Group of Radiation Protection Standardization Committee, the Japan Health Physics Society (JHPS) developed a guideline for radiation dose monitoring for the lens. Materials and Methods: The Working Group of the JHPS discussed the criteria of non-uniform exposure and the management criteria set not to exceed the dose limit for the lens. Results and Discussion: In July 2020, the JHPS guideline was published. The guideline consists of three parts: main text, explanations, and 26 examples. In the questions, the corresponding answers were prepared, and specific examples were provided to enable similar cases to be addressed. Conclusion: With the development of the guideline on radiation dose monitoring of the lens, radiation managers and workers will be able to smoothly comply with revised regulations and optimize radiation protection.

Evaluation of Chromosomal Alteration in Electrical Workers Occupationally Exposed to Low Frequency of Electro Magnetic Field (EMFs) in Coimbatore Population, India

  • Balamuralikrishnan, Balasubramanian;Balachandar, Vellingiri;Kumar, Shanmugam Suresh;Stalin, Nattan;Varsha, Prakash;Devi, Subramaniam Mohana;Arun, Meyyazhagan;Manikantan, Pappuswamy;Venkatesan, Chinnakulandhai;Sasikala, Keshavarao;Dharwadkar, Shahnaz N.
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제13권6호
    • /
    • pp.2961-2966
    • /
    • 2012
  • Extremely low frequency electro magnetic fields (EMFs) have been classified as possibly carcinogenic to humans by the International Agency for Research on Cancer. An increased number of chromosomal alterations in peripheral lymphocytes are correlated with elevated incidence of cancer. The aim of the present study was to assess occupationally induced chromosomal damage in EMF workers exposed to low levels of radiation. We used conventional metaphase chromosome aberration (CA) analysis and the micronucleus (MN) assay as biological indicators of non ionizing radiation exposure. In the present study totally 70 subjects were selected including 50 exposed and 20 controls. Informed written consent was obtained from all participants and the study was performed in accordance with the Declaration of Helsinki and the approval of the local ethical committee. A higher degree of CA and MN was observed in exposed subjects compared to controls, the frequency of CA being significantly enhanced with long years of exposure (P<0.05). Moreover increase in CA and MN with age was noted in both exposed subjects and controls, but was significantly greater in the former. The results of this study demonstrated that a significant induction of cytogenetic damage in peripheral lymphocytes of workers occupationally exposed to EMFs in electric transformer and distribution stations. In conclusion, our findings suggest that EMFs possess genotoxic capability, as measured by CA and MN assays; CA analysis appeared more sensitive than other cytogenetic end-points. It can be concluded that chronic occupational exposure to EMFs may lead to an increased risk of genetic damage among electrical workers.

Effect of a 20 kHz Sawtooth Magnetic Field Exposure on the Estrous Cycle in Mice

  • Jung, Kyung-Ah;Ahn, Hae-Sun;Lee, Yun-Sil;Gye, Myung-Chan
    • Journal of Microbiology and Biotechnology
    • /
    • 제17권3호
    • /
    • pp.398-402
    • /
    • 2007
  • Abstract Female mice post weaning were exposed to 20 kHz sawtooth electric and magnetic fields (EMF) with $6.25{\mu}T$ peak intensity for 6 weeks. Estrous cycles were checked using vaginal smears over the last 10 days of the experimental period. The vaginal smears from EMF-exposed mice revealed an increase in the frequency of one or two phases persisting. The number of estrous cycles less than 1 was more in the EMF-exposed group than in the sham control group. Furthermore, in the EMF-exposed group, the duration of proestrous and metestrous stages of the estrous cycle was significantly increased compared with the control group. In conclusion, our results suggest that exposure to 20 kHz sawtooth EMF may affect normal cycling of the estrous cycle by disrupting the female reproductive endocrine physiology. We should not disregard the possible adverse reproductive effect of the 20 kHz sawtooth EMF generated under the occupational exposure situation in females.

Intercomparison Exercise at Harshaw 6600, DVG-02TM, and D-Shuttle Dosimeters for the Individual Monitoring of Ionizing Radiation

  • Kim, Dmitriy Spartakovich;Murayama, Kentaro;Nurtazin, Yernat;Koguchi, Yasuhiro;Kenzhin, Yergazy;Kawamura, Hiroshi
    • Journal of Radiation Protection and Research
    • /
    • 제44권2호
    • /
    • pp.79-88
    • /
    • 2019
  • Background: The main goal of experiments is to compare various operational and technical characteristics of D-Shuttle semiconductor personal dosimeters of the Japanese company "Chiyoda Technol Corporation" and Harshaw thermoluminescent dosimeters (TLD) manufactured by "Thermo Fisher Scientific" and DTL-02 of the Russian Research and Production Enterprise (RPE) "Doza" by their occupational and calibration exposure at various dose equivalents from 0.5 to 20 mSv of gamma-radiation. Materials and Methods: Besides dosimeters DTL-02, D-Shuttle and Harshaw TLD, there were also used: (1) the primary reference radionuclide source Hopewell Designs IAEA: G10-1-12 with $^{137}Cs$ isotope (an error is not more than 6% and activity is 20 Ci), and (2) the verification device UPGD-2M of RPE "Doza" and installed in the National Center for Expertise and Certification of the Republic of Kazakhstan (Kapchagai, the National Center for Expertise and Certification). Results and Discussion: The main results of researches are the following: (1) TLDs for Harshaw 6600 and DVG-02TM have an approximately equal measurement accuracy of the individual dose equivalents in the range from 0.5 to 20 mSv of gamma-radiation. (2) Advantages of dosimeters for Harshaw 6600 are due to the high measurement productivity and opportunity to indicate the dose on the skin $H_p$(0.07). Advantages of DVG-02TM consist of operation simplicity and lower cost than of Harshaw 6600. (3) D-Shuttles are convenient for use in the current and the operational monitoring of ionizing radiation. Measurement accuracy and 10% linearity of measurements are ensured when D-Shuttle is irradiated with dose equivalents below 1 mSv at the equivalent dose rate not higher than $3mSv{\cdot}hr^{-1}$. This allows using D-Shuttle at a routine technological activity. Conclusion: The obtained results of experiments demonstrate advantages and disadvantages of D-Shuttle semiconductor dosimeters in comparison with two TLD systems of DVG-02TM and Harshaw 6600.

Web-based Personal Dose Management System for Data Recording on Dosimeter Usage: A Case of Tanzania Atomic Energy Commission

  • Mseke, Angela;Ngatunga, John Ben;Sam, Anael;Nyambo, Devotha G.
    • International Journal of Computer Science & Network Security
    • /
    • 제22권2호
    • /
    • pp.15-22
    • /
    • 2022
  • Modern technology drives the world, increasing performance while reducing labor and time expenses. Tanzania Atomic Energy Commission (TAEC) tracks employee's levels of exposure to radiation sources using dosimeters. According to legal compliance, workers wear dosimeters for three months and one month at the workplace. However, TAEC has problems in tracking, issuing and returning dosimeters because the existing tracking is done manually. The study intended to develop a Personal Dose Management System (PDMS) that processes and manages the data collected by dosimeters for easy and accurate records. During the requirements elicitation process, the study looked at the existing system. PDMS' requirement gathering included document reviews, user interviews, and focused group discussions. Development and testing of the system were implemented by applying the evolutionary prototyping technique. The system provides a login interface for system administrators, radiation officers, and Occupational Exposed Workers. The PDMS grants TAEC Staff access to monitor individual exposed workers, prints individual and institutional reports and manages workers' information. The system reminds the users when to return dosimeters to TAEC, generate reports, and facilitates dispatching and receiving dosimeters effectively. PDMS increases efficiency and effectiveness while minimizing workload, paperwork, and inaccurate records. Therefore, based on the results obtained from the system, it is recommended to use the system to improve dosimeter data management at the institution.