• Title/Summary/Keyword: Occlusion pressure

Search Result 130, Processing Time 0.024 seconds

Superior Vena Cava Syndrome -2 Bypass Graft Cases- (상공정맥 증후군 -Dacron & Nylon 환치수술 2예-)

  • 김정석
    • Journal of Chest Surgery
    • /
    • v.2 no.1
    • /
    • pp.65-72
    • /
    • 1969
  • Superior Vena Cava Syndrome: Dacron and Nylon graft between the left innominate vein and the right atrial appendage. Two cases with typical superior vena cave syndrome treated by by-pass graft between the left innominate vein and the right atrial apepndage were presented. One of them was a 58 year old farmer who suffered from marked swelling of the neck and upper half of body, the other was a 50 years old government employee who had acutely progressive symptoms of superior vena cave obstruction. Both of cases revealed that [1] cubitel venous pressure was markedly increased. [2] tumors were noted in the posterior mediastinum by laminography. [3] preoperative cavogram showed the occlusion of superior vena cava and marked collaterals. Dacron and Nylon graft were inserted between the left innominate vein and the right atrial appendage. Postoperatively, the symptoms were relieved markedly, showing edema free face and decreased cubital venous pressure. Postoperative cavogram showed patent graft. Histologically the first case was diagnosed as squamous cell carcinoma and the second as undifferentiated carcinoma, originated probably from bronchus. Total doses of 3150 r X-ray irradiation and 5000 mg of 5-FU were administered in each cases. The first case expired 11 months postoperatively without recurrence of superior vena cave obstruction symptom and the second case is living now without obstruction signs, 4 months after by-pass operation.

  • PDF

A Study on the Surface Treatment of Magnesium for marine engine systems (초경량성 박용기관을 위한 마그네슘 표면처리)

  • Yun, Yong-Sup
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.2
    • /
    • pp.252-257
    • /
    • 2011
  • Magnesium thin films for marine engine parts such as the engine block and the cylinder head cover etc. were prepared on the magnesium alloy(AZ91D) substrate by Thermo-electron activated Ion-plating method. The influence of gas pressure and substrate bias voltages on the crystal orientation and morphology of the films was investigated with X-ray diffraction and field emission scanning electron microscope(FE-SEM), respectively. Moreover, the effect of crystal orientation and morphology of the magnesium films on the its hardness property was investigated as well. From the results, the hardness of the films was increased in Ar gas pressure due to the grain boundary strengthening and occlusion effects.

A Study on the Color Stability of Temporary Resins according to Polymerizing Methods and Staining (온성 방법에 따른 수종의 임시 수복용 레진의 착색시의 색 안정성에 관한 연구)

  • Park, Sung-Ho;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.16 no.1
    • /
    • pp.1-11
    • /
    • 2000
  • Dental temporary resin should have adequate strength and similar esthetics as natural teeth. Recently esthetics has become a high priority in clinical dentistry. Thus the evaluation of color stability of dental temporary resin has become an important part in dental research. The purpose of this study was to evaluate the difference in color stability of 3 resins($Snap^{(R)}$, Temporary bridge $resin^{(R)}$, Trim $II^{(R)}$) according to polymerizing methods and stainning. The resins were divided into groups by 2 types of polymerizing methods ( air or pressure and heat curing) The resins were dyed with coffee, chlorhexidine and artificial saliva and then the color stability was evaluated with a spectrophotometer(CM-503i, Minolta, Japan). The results were as follows ; 1. In the color stability according to polymerizing method, pressure and heat polymerizing method was higher than air polymerizing method. 2. The color stability according to staining fluid decreased in the order of I, II, III group, there was significant difference among the groups of staining fluid. 3. The color stability according to resins decreased in the order of $Snap^{(R)}$, Trim $II^{(R)}$, Temporary Bridge $resin^{(R)}$, The $Snap^{(R)}$ resin was highest color stability, there was significant difference among the 3 resins.

  • PDF

Duplex Sonography in Subclavian Steal Syndrome Treated by Stent Insertion (이중초음파검사상 빗장밑혈류빼앗김증후군이 관찰된 환자에서의 스텐트 삽입 후 추적)

  • Han, Minho
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.50 no.3
    • /
    • pp.370-374
    • /
    • 2018
  • Subclavian steal syndrome is a type of obstructive artery disease caused by severe stenosis and occlusion of a left proximal subclavian artery or brachiocephalic trunk. The resulting vertebro-basilar insufficiency symptoms are due to retrograde blood flow from the contralateral vertebral and basilar arteries into the low-pressure ipsilateral upper extremity vessels. For that reason, patients usually experience dizziness or arm ischemic symptoms. Neurointervention is an effective treatment for ischemic stroke, including the subclavian artery stenosis. This paper reports a patient with subclavian steal syndrome who had a vertebral artery Doppler waveform change in duplex sonography and a 12 mmHg difference in interarm systolic blood pressure. A stenotic lesion of the subclavian artery was treated effectively by inserting a precise stent. The follow up examination showed that the vertebral artery Doppler waveform change disappeared and recovered and that the 12 mmHg difference in interarm systolic blood pressure decreased to 5 mmHg after treatment.

Influence of marginal bone resorption on two mini implant-retained mandibular overdenture: An in vitro study

  • Guo, Ying;Kono, Kentaro;Suzuki, Yasunori;Ohkubo, Chikahiro;Zeng, Jian-Yu;Zhang, Jing
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.1
    • /
    • pp.55-64
    • /
    • 2021
  • PURPOSE. To investigate the biomechanical effect of marginal bone resorption (MBR) on the mandibular mini implant (MI)-retained overdenture (MI-OD) on the edentulous model. MATERIALS AND METHODS. The experimental mandibular edentulous model was modified from a commercial model with 2 mm thick artificial soft tissue under denture base. Two MIs (Φ2.6 mm × 10 mm) were bilaterally placed between the lateral incisor and the canine area and attached with magnetic attachments. Three groups were set up as follows: 1) alveolar bone around the MI without MBR (normal group), 2) with MBR to 1/2 the length of the implant (resorption group), and 3) complete denture (CD) without MI (CD group). Strain around the MI, pressure near the first molar area, and displacement of denture were simultaneously measured, loading up to 50 N under bilateral/unilateral loading. Statistical analysis was performed using independent-samples t test and one-way ANOVA (α=.05). RESULTS. The strain around the MI with MBR was approximately 1.5 times higher than that without MBR. The pressure in CD was higher than in MI-ODs (P<.05), while there was no statistical difference between the normal and resorption group (P>.05). Similarly, the CD demonstrated a greater displacement of the denture base than did the MI-ODs during bilateral and unilateral loadings (P<.05). CONCLUSION. The strain around the MI with MBR was approximately 1.5 times higher than that without MBR. The pressure on posterior alveolar ridge and denture displacement of MI-ODs significantly decreased compared to CDs, even when MBR occurs. Bilateral balanced occlusion was recommended for MI-ODs, especially when MBR occurred.

Epidural Hematomas due to Occipital Artery Injury Following Ventriculoperitoneal Shunt and Extraventricular Drainage

  • Choi, Jeong-Hoon;Moon, Jae-Gon;Hwang, Do-Yun;Choi, Jong-Hun
    • Journal of Korean Neurosurgical Society
    • /
    • v.41 no.5
    • /
    • pp.314-317
    • /
    • 2007
  • Ventriculoperitoneal [VP] shunt is a common treatment for hydrocephalic patients. However, complications, such as shunt tube occlusion, infection, intracranial hemorrhage, seizure can occur. Of these, intracranial hemorrhage may occur due to intracranial vascular injury or a rapid decrease of intracranial pressure [ICP]. Most of these hemorrhages are subdural hematomas [SDH] while a few are epidural hematomas [EDH]. It is extremely rare for an intracranial hemorrhage to occur due to an extension of the bleeding from an injured extracranial vessel. We report two cases of EDH due to occipital artery injury following VP shunt and extraventricular drainage [EVD].

A Study on the Hypotensive Action of Mori Radicis Cortex Water Extract in the Rabbit. (상백피 수성 엑기스의 혈압강하작용에 관한 연구)

  • 고석태;신흥수
    • YAKHAK HOEJI
    • /
    • v.21 no.1
    • /
    • pp.17-25
    • /
    • 1977
  • Intravenous injection of Mori Radicis Cortex Water Extract (MWE) regularly caused the does-related, lowering of blood pressure in the rabbits anesthetized with urethane, and then did not show the cumulative effect and the tachyphylaxis. The hypotensive effects of MWE were inhibited by atropine, chlorisodamine, phentolamine and bethanidine, while not altered by diphenhydramine, propranolol and cyproheptadine. Atropine after chlorisondamine did not alter the effect of MWE. MWE potentiated the pressor effect of nore-pinephrine, but did not carotid occlusion was inhibited by previous administration of MWE. It is conclude that MWE elicits hypotensive action in the rabbit by the centrally induced cholinergic effect and the inhibitation of responses to sypathetic adrenergic nerve activation.

  • PDF

Magnesium Thin Films Possessing New Corrosion Resistance by RF Magnetron Sputtering Method

  • Lee, M.H.;Yun, Y.S.;Kim, K.J.;Moon, K.M.;Bae, I.Y.
    • Corrosion Science and Technology
    • /
    • v.3 no.4
    • /
    • pp.148-153
    • /
    • 2004
  • Magnesium thin flims were prepared on cold-rolled steel substrates by RF magnetron sputtering technique. The influence of argon gas pressure and substrate bias voltage on their crystal orientation and morphology of the coated films were investigated by scanning electron microscopy (SEM) and X-ray diffraction, respectively. And the effect of crystal orientation and morphology of magnesium films on corrosion behaviors was estimated by measuring anodic polarization curves in deaerated 3%NaCl solution. From the experimental results, all the sputtered magnesium films showed obviously good corrosion resistance to compare with 99.99% magnesium target of the sputter-evaporation metal. Finally it was shown that the Corrosion-resistance of magnesium films can be improved greatly by controlling the crystal orientation and morphology with effective use of the plasma sputtering technique.

Management of complications of oral appliance therapy for snoring and obstructive sleep apnea (코골이 및 폐쇄성 수면무호흡증의 구강내 장치 치료시 부작용 및 관리)

  • Jo, Jung-Hwan
    • The Journal of the Korean dental association
    • /
    • v.57 no.5
    • /
    • pp.270-278
    • /
    • 2019
  • Oral appliances therapy is becoming increasingly recognized as a successful treatment for snoring and obstructive sleep apnea(OSA). Compared with continuous positive airway pressure(CPAP), the gold standard therapy for OSA, oral appliance therapy are less efficacious for severe OSA but are more acceptable and tolerable for patients, which in turn, may lead to a comparable level of therapeutic effectiveness. Nevertheless, the various side effects of oral appliance therapy, such as, increased salivation or dryness, pain or discomfort in the teeth or gums, occlusal discomfort in the morning, temporomandibular disorders, dental and occlusal changes may cause discontinuation of treatment or changes in treatment plan. Therefore, oral appliance therapy should be provided by a qualified dentist who can evaluate oral tissues, occlusion, and temporomandibular joints, and prevent and manage the possible side effects.

  • PDF

Cerebroprotective Effect of Nociceptin on Transient Focal Cerebral Ischemia in Rats

  • Lee Seung Yoon;Lee Won Suk;Choi Chang Hwa
    • Biomedical Science Letters
    • /
    • v.11 no.2
    • /
    • pp.201-209
    • /
    • 2005
  • This study aimed to investigate the cerebroprotective effect of nociceptin on transient focal cerebral ischemia in Sprague-Dawley rats by determining the changes in regional cerebral blood flow (rCBF) and the infarct size. Right middle cerebral artery (MCA) was occluded for 2 hours, and thereafter was followed by reperfusion by an intraluminal monofilament technique. An open cranial window was made on the right parietal bone for determination of continuous changes in rCBF by laser-Doppler flowmetry. The infarct size was morphometrically determined using the 2,3,5-triphenyltetrazolium chloride technique. In normal rats, nociceptin ($0.01\~100\;nmol/kg$, Lv.) increased rCBF and decreased cerebral arterial resistance in a dose-dependent manner. Systemic arterial blood pressure was little affected by nociceptin at the doses of 0.01 and 0.1nmol/kg, but dose-dependently reduced at the doses of 1 nmol/kg or more. In transient cerebral ischemic rats, nociceptin ($0.01\~0.1$ nmol/kg, i.p.) significantly attenuated the postischemic cerebral hyperemia, and progressively increased rCBF. The improving effect of nociceptin on the postischemic rCBF response was markedly blocked by pretreatment with $[Nphe^1]nociceptin(1-13)NH_2$ (1 nmol/kg, i.p.), a selective nociceptin receptor antagonist, but not by naloxone ($3{\mu}mol/kg$, i.p.), a selective opioid receptor antagonist. The cerebral infarct size was significantly reduced by nociceptin ($0.01\~0.1$ nmol/kg) administered i.p. 5 min after MCA occlusion in transient cerebral ischemia of 2-hour MCA occlusion and 22-hour reperfusiion. It is suggested that nociceptin improves the postischemic cerebral hemodynamics and thereby has a cerebroprotective effect in transient focal cerebral ischemia.

  • PDF