• 제목/요약/키워드: Occlusal thickness

검색결과 98건 처리시간 0.023초

하악관에 관한 방사선학적 연구 (A RADIOGRAPHIC STUDY ON THE MANDIBULAR CANAL)

  • 조성은;김재덕
    • 치과방사선
    • /
    • 제21권2호
    • /
    • pp.307-316
    • /
    • 1991
  • The purpose of this study is to improve the availabilities of radiographic technics as diagnostic method related to mandibular canal in dental clinic. For this study 12 dry mandibles were used and 12 orthopantomograms were taken for measuring the gonial angle and the angle of mandibular canal to inferior border of mandible. 12 sites located between the 1st premolar to the 3rd molar region of 3dry mandibles were selected randomly, for measuring the vertical image magnification rates on three films; intraoral film, orthopantomogram, and computed tomogram, respectively and the thickness of cortical bone, and for observing bucco-lingually and supero-inferiorly location of the mandibular canal. The acquired results were as follows: 1. The means of the gonial angle and the angle of mandibular canal to inferior border of mandible were 123.9° and 143.5° And the two angles of dry mandible in alveolar crest stage were greater than in alveolar socket stage. 2. The vertical image length on intraoral film by paralleling technic was magnified by 3.07% on the average, the length on orthopantomogram by 18.49%, and the length on computed tomogram by 0.27%. 3. Observation of the bucco-lingually positional relationship of the mandibular canal was impossible by occlusal projection with the cross section technic and intraoral standard projection with the Clack's rule, however, possible by computed tomogram. 4. The thickness of the cortical bone of mandible was thickest in inferior border, and thicker by 6.59% at buccal side than at lingual side.

  • PDF

$CO_2$ 레이저 광의 조사조건에 따른 치아의 치수강내 온도상승에 관한 연구 (A Study of Temperature Changes in the Dental Tissues Irradiated by $10.6{\mu}m$ Laser Beam)

  • 고동섭;박용환;신상훈;엄효순;김웅;이찬영
    • 한국광학회지
    • /
    • 제1권2호
    • /
    • pp.210-216
    • /
    • 1990
  • 본 연구에서는 레이저와 치아조직과의 상호작용에 대한 연구의 일환으로, $CO_2$ 레이저의 발진파장인 $10.6\mu\textrm{m}$의 레이저 빔 조사시에 일어나는 치아의 온도변화를 조사하기 위하여 $CO_2$ 레이저 발진장치를 제작하여 여러 가지 조사 에너지, 조사시간에 대하여 발거된 치아의 치수강의 온도변화를 측정 분석하였다. 측정한 data를 분석하여 최대 상승온도 $\DeltaT_m$를 추정할 수 있는 다음과 같은 실용적인 경험식을 얻었다. $\DeltaT_m=\alphaP\Delta\tauexp(-\betad)$$ 여기서 P는 레이저의 출력(W)이고 $\Delta\tau$는 조사시간(sec), d는 치아의 두께(mm)이다.

  • PDF

근관 전색재의 방사선 불투과성에 관한 비교연구 (A COMPARATIVE STUDY ON RADIOPACITY OF ROOT CANAL SEALERS)

  • 김태민;김서경;황인남;황윤찬;강병철;윤숙자;이재서;오원만
    • Restorative Dentistry and Endodontics
    • /
    • 제34권1호
    • /
    • pp.61-68
    • /
    • 2009
  • 다양한 근관전색제는 방사선 사진상 주위 해부학적 구조와 구별될 만한 방사선 불투과성을 나타내야 한다. 따라서 이런 물질들이 근관에 충전될 때의 방사선 불투과성 정도를 평가해야 할 필요성이 대두되고 있다. 본 실험에서는 다양한 근관전색제들의 방사선 불투과성을 평가하고자, 방사선 노출조건에 따른 aluminium step wedge에 대한 광학 밀도를 알아보고, 그 중 적절한 노출조건을 선택하여 수종의 근관 전색재의 방사선 불투과성 정도를 알루미늄 두께로 환산하여 비교해 보고자 한다. 방사선 불투과성의 기준을 위해 11개의 step으로 구성된 aluminum step wedge을 사용하여, 60kVp, 70kVp 관전압 상태에서 각각 0.2, 0.3, 0.4초 그리고 0.2, 0.3, 0.33초의 노출시간으로 교합필름상에서 방사선 촬영후 적절한 노출 조건을 구하였다. 직경 5 mm, 각각의 두께 0.5, 1.0, 1.5, 2.0, 2.5, 3.0 mm인 10종 (Tubli-$Seal^{TM}$, Kerr pulp Canal $Sealer^{TM}$, $AH26^{(R)}$, $AHplus^{(R)}$, AH plus jet starter $kit^{TM}$, Ad $seal^{TM}$ $Sealapex^{TM}$, Nogenol root canal $sealer^{TM}$, ZOB $seal^{TM}$, $Epiphany^{TM}$)의 근관전색재 시편을 각 재료와 두께당 10개씩 제작한 후, 동일한 두께의 상아질 시편, aluminum step wedge와 함께 정해진 노출시간에 따라 방사선 촬영을 하였다. 모든 필름은 자동현상기로 현상하였다. 시편의 방사선 흑화도를 densitometer로 5회 반복 측정 후, 평균값을 구하여 알루미늄 두께로 환산하였다. 얻어진 정보를 분석하여 다음의 결과를 얻었다. 1. 관전압 60 kVp에서 노출시간 0.2, 0.3, 0.4초, 70 kVp에서 0.2, 0.3, 0.33초로 변화를 주어 방사선 촬영을 하였을 때, 흑화도가 ISO No. 6876 규격에 가장 적합한 것은 60 kVp, 0.2초 일 경우였다. 2. 측정된 근관 전색제의 방사선 불투과성은 2.29 mm Al (NOGENOL)로부터 13.69 mm Al (AH Plus jet)까지 다양하게 나타났으나, 모두 ANSI/ADA specification (2000) 또는 ISO No. 6876 (2001) 규격이 제시한 최소한 3 mm Al이상의 방사선 불투과성을 지녀야 한다는 기준에 적합하였다. 3. 재료의 두께가 증가할수록 방사선 불투과성은 증가하지만, 정비례하지는 않았다. 4. 각 실험재료의 1 mm 두께의 시편에 대한 mm Al값들은 통계적으로 유의한 차이가 있었다. 이상의 결과는 본 실험에 사용된 수종의 근관 전색재는 모든 규격에 적합한 방사선 불투과성을 가지고 있음을 시사한다.

All-in-one adhesive의 다층적용이 미세인장결합강도에 미치는 영향 (THE EFFECT OF MULTIPLE APPLICATION ON MICROTENSILE BOND STRENGTH OF ALL-IN-ONE DENTIN ADHESIVE SYSTEMS)

  • 손성애;허복
    • Restorative Dentistry and Endodontics
    • /
    • 제29권5호
    • /
    • pp.423-429
    • /
    • 2004
  • The purpose of this study was to evaluate the effect of multiple application of all-in-one dentin adhesive system on microtensile bond strength using confocal laser scanning microscope and microtensile bond strength test. Flat occlusal dentin surfaces were prepared using low-speed diamond saw. In group I, Scotchbond Multipurpose (SM) was applied by manufacturer's recommendation. In group II, after Adper Prompt L-Pop was applied for 15s and light cured for 10s. the second coat was re-applied and light-cured. In group III, after light-curing the second layer. the third coat was re-applied and light-cured. Specimens bonded with a resin-composite were sectioned into resin-dentin stick for measuring the adhesive layer thickness by confocal laser scanning microscope and evaluating micro-tensile bond strength. The adhesive layers of three-step dentin adhesive system. 3 coats of Adper Prompt L-Pop had significantly thicker than SM. 2 coats of Adper Prompt L-Pop (p < 0.05). However. there was no significant differences in bond strengths between SM and 3 coats of Adper Prompt L-Pop (p > 0.05). And SM. 3 coats of Adper Prompt L-Pop had significantly higher than 2 coats of Adper Prompt L-Pop in bond strengths (p < 0.05).

임프란트를 이용한 고정성 계속가공의치의 FRAMEWORK 형태에 관한 연구 (A SUTDY ABOUT THE SHAPE OF THE FRAMEWORK OF THE FIXED BONE ANCHORED BRIDGE USING DENIAL IMPLANTS)

  • 김태균;이영수;유광희
    • 대한치과보철학회지
    • /
    • 제36권1호
    • /
    • pp.104-119
    • /
    • 1998
  • The purpose of this study was pertinent design of the framework of the fixed bone anchored bridge using implants in the edentulous mandible through analysis of stress distribution by the three dimensional finite element analysis method. The results were as follows: 1. The L-shaped framework was favorable in restoring the edentulous mandible by implants and fixed bone anchored bridge. 2. The structure of the framework should be designed to endure the occlusal load because of stress concentration at the most distal abutment of the framework. 3. The stress at the distal implant where cantilever starts was twice as much as that of other portions. 4. Compressive stress was generated on the framework of the mesial side of the distal implant and extrusive force was induced to the mesially positioned implants. 5. The height of vertical plate was high as possible as can be to distribute stresses concentrating bucco-lingually and labio-lingually in the framework between abutments, 6. Reinforcement of the horizontal plate thickness was needed because stress was loaded more on the horizontal plate than on the vertical plate of the framework. 7. Lengthening of the vertical plate can compensate for any limitations in horizontal plate width.

  • PDF

The effect of various polishing systems on surface roughness and phase transformation of monolithic zirconia

  • Caglar, Ipek;Ates, Sabit Melih;Duymus, Zeynep Yesil
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권2호
    • /
    • pp.132-137
    • /
    • 2018
  • PURPOSE. The purpose of this study was to evaluate and compare three polishing systems on the surface roughness and phase transformation of monolithic zirconia. MATERIALS AND METHODS. 100 disk shaped specimens (10 mm diameter, 3 mm thickness) were fabricated from monolithic zirconia blocks. 20 specimens were left as a control group and remaining specimens were grinded by diamond bur to simulate the occlusal adjustments. Grinded specimens were randomly divided into 4 groups: group G (no polishing), group M (Meisinger, zirconia polishing kit), group E (EVE Diacera, zirconia polishing kit), and group P (EVE Diapol, porcelain polishing kit). Surface roughness was measured with profilometer and surface topography was observed with SEM. XRD analysis was performed to investigate the phase transformation. Statistical analysis was performed with one-way ANOVA and Tukey's post hoc tests at a significance level of P=.05. RESULTS. All polishing groups showed a smoother surface than group G. Among 3 polishing systems, group M and group E exhibited a smoother surface than the group P. However, no significant differences were observed between group M and group E (P>.05). Grinding and polishing did not cause phase transformations in zirconia specimens. CONCLUSION. Zirconia polishing systems created a smoother surface on zirconia than the porcelain polishing system. Phase transformation did not occur during the polishing procedure.

3차원 유한요소해석을 이용한 비우식성 치아의 수복 방법 (An Optimal Restoration Method of Noncarious Cervical Lesions Using Three-Dimensional Finite Element Analysis)

  • 우성관;김광훈;박정길;허복;손권
    • 한국정밀공학회지
    • /
    • 제24권7호
    • /
    • pp.112-119
    • /
    • 2007
  • Cavities of Class V are caused by heavy occlusal loads due to bruxism and clenching habit. It is general to restore abfraction lesions with dental filler materials to reduce stress concentration. A material should be selected from various dental products based on long term clinical experiences or personal preference concerning filler methods. A quantitative criterion is necessary to make an evaluation of the results as dentists decide treatment methods and dental materials relying on their clinical experiences. The purpose of this study is to find an optimal restoration method and material for noncarious cervical lesions using the finite element method. An objective function was defined to minimize the sum of tensile and compressive stresses. Several models with different combinations of resins were suggested and compared in terms of the values of objective function. An optimal solution was to fill TetricFlow inside the lesion and Z100 in the remaining region with a thickness ratio of 0.125.

하악과두에 발생된 골연골증 (OSTEOCHONDROMA OF THE MANDIBULAR CONDYLE)

  • 정기훈;김은경
    • 치과방사선
    • /
    • 제23권2호
    • /
    • pp.373-378
    • /
    • 1993
  • 저자들은 희귀한 하악과두의 골연골종으로 진단 내려진 27세 남성 환자에서 아래와 같은 사항을 관찰하였다. 1. 임상적으로 좌측안면부의 비대칭과, 교합이상 그리고 저작 시 좌측 악관절의 동통이 있었다. 2. 방사선학적으로 좌측과두에 내측으로 균일한 방사선불투과성의 종괴가 보였으며, 좌측 하악지 길이의 증가 및 우측으로의 하악 변위가 관찰되었다. 또 골스캔상에서 좌측 악관절부위의 hot spot이 관찰되었다. 3. 조직병리학적으로 불규칙한 골의 형성과 연골모를 볼 수 있었다.

  • PDF

In-Ceram Alumina Bridge Restoration의 단기예후에 관한 임상적연구 (THE CLINICAL STUDY ON SHORT TERM PROGNOSIS OF IN-CERAM ALUMINA BRIDGE RESTORATION)

  • 조병완;박재범;안재진
    • 대한치과보철학회지
    • /
    • 제35권3호
    • /
    • pp.544-556
    • /
    • 1997
  • All ceramic restorations except In-Ceram Alumina system gave a good esthetics and an exellent marginal fidelity. The flexural strength of them had about 150MPa, so the indication is only single crown. By using In-ceram Alumina System(450Mpa), it is thought to be possible to construct bridge for its high flexural strength. But the prognosis is unclear, The purposes of this study are to clear short term prognosis of In-Ceram bridge restorations, to elucidate its clinical significance. Among 22 In-Ceram Bridge restored in our department, 11 In-Ceram bridges with follow up were used. The period of placement is from 1 to 18 months. The results were as follows : 1. Among follow up 11 bridges, 2 bridges were fractured. One is 4 unit in maxillary lateral incisors, the other is 3 unit bridge in maxillary canine and premolar. Including 11 bridge without follow up, failure rate is very low(2/22). 2. The fracture sites are connector areas between abutment and pontic. To maintain In-Ceram bridge for long term period, it is needed to remove the nonphysiologic occlusal force and to have sufficient thickness of alumina core. For estabilishing clinical use of In-Ceram bridges, it is thought to need clinical research during long term period.

  • PDF

왁스 밀링 방법 및 디지털 광 프로젝션 방법으로 제작된 3본 금속 구조물의 적합도 비교 (Comparison the fit of three-unit metal framework fabricated by wax milling method and digital light projection method)

  • 이정환;안재석
    • 대한치과기공학회지
    • /
    • 제41권1호
    • /
    • pp.9-19
    • /
    • 2019
  • Purpose: This study was conducted to comparative evaluate the marginal and internal gap of three-unit metal frameworks(Co-Cr) fabricated by wax milling method and digital light projection method of CAD/CAM systems. Methods: All the specimens were fabricated by three different fabrication methods: conventional wax up with casting(CWC), milled wax block with casting(MWC), digital light projection with casting(DLPC) (n=10 each). The marginal and internal fits of specimens were examined using a replica technique. The light-body silicone thickness was measured at 8 reference points(each abutment: 16 measurements). All measurements were conducted by a stereomicroscope. Digital photo were taken at $150{\times}$ magnification and then analyzed using a measurement software. The Mann-Whitney test was used for analyzing the results. Results: Statistically significant differences were found between the fabrication methods(p<0.001). The mean(SD) is ${\mu}m$ for fabrication methods, the mean marginal fit were recorded respectively, CWC 63(38), MWC group 50(33), DLPC 103(54) and the mean internal fit CWC 96(47), MWC group 116(41), DLPC 138(66). Conclusion : The marginal and internal fit were statistically different according to the fabrication methods(p<0.001). In all fabrication methods, the greatest misfit was found the occlusal area of all specimens.