• 제목/요약/키워드: Occlusal contacts

검색결과 73건 처리시간 0.026초

E.M.G. biofeedback therapy에 의한 occlusal contact의 변화에 관한 련구 (A Study on the Changes of Occlusal Contacts after Electromyographic Biofeedback Therapy)

  • 김영주;이승우;김영구
    • Journal of Oral Medicine and Pain
    • /
    • 제10권1호
    • /
    • pp.33-39
    • /
    • 1985
  • Changes of occlusal contacts after E.M.G. biofeedback therapy with D.D.S. (Self control system, EMG 220, Sandiago California) was investigated in 20 SNUH students and residents with normal occlusion. Treatment time was 30 minutes on every subject. Occlusal contacts of before biofeedback therapy were taken at 4: 00 P.M. and that of after biofeedback therapy were taken at 4:40 P.M. Author compared the occlusal contacts before biofeedback therapy with that of after biofeedback therapy. The obtained results were as follow : 1. The number of occlusal contacts was 23.9, before biofeedback therapy and, 26.3, after biofeedback therapy. 2. The percentage of accentuated contact to diffuse contact was 78.5%, before treatment and 38.8% after treatment. 3. 6 heaviest contacts were changed 4.3 teeth per one subject after biofeedback therapy.

  • PDF

유리단 국소의치 환자에서 T-scan system을 이용한 중심교합시에 교합접촉 양상 연구 (COMPUTERIZED EVALUATION OF OCCLUSAL CONTACTS IN CENTRIC CLOSURE IN DISTAL EXTENSION PARTIAL DENTURE CASES)

  • 이호용
    • 대한치과보철학회지
    • /
    • 제30권4호
    • /
    • pp.565-573
    • /
    • 1992
  • This clinical study was to analyze occlusal contacts in maximum intercuspation on distal extension partial denture and to compare tooth contact state between the denture teeth and abutment teeth by time mode and force mode using the T-scan system. The subjects ware twenty-one adult patients with upper natural teeth and lower distal extension partial denture. Conclusion : 1. The patient with simultaneous occlusal contacts both denture tooth and abutment and bilaterally in Kennedy Class I cases was one-sixth, but there was no one with symmetric occlusal and equal force among bilateral denture teeth and abutments. 2. The five-fifteenth of Kennedy Class I case patients resulted in simultaeous occlusal contacts bet-ween denture teeth and abutments but no one has the symmetric occlusal contacts and unifarm force between denture teeth and abutment teeth.

  • PDF

T-Scan system을 이용한 하악 측방운동 시 교합접촉 분석 (An occlusal contact analysis of lateral mandibular movement using T-Scan system)

  • 송주헌;주세진;이호선;강동완;이경제
    • 대한치과보철학회지
    • /
    • 제53권2호
    • /
    • pp.128-137
    • /
    • 2015
  • 목적: 교합접촉 분석에 대한 연구는 외국인을 대상으로 이루어져왔다. 이번 연구에서는 T-Scan을 이용하여 하악 측방운동시 교합접촉 분석을 통해 한국인의 교합 양상을 파악해보고자 한다. 재료 및 방법: 87명을 대상으로 T-Scan을 이용하여 하악 측방운동시 교합접촉을 분석하였다. 최대교두감합위에서 측방으로 3 mm범위까지 교합접촉을 측정하였으며, 최대교두감합위, 우측방운동, 좌측방운동을 각각 3회씩 측정하였다. 교합접촉은 thin metal foil을 이용하여 재확인하였다. 결과는 균형측 교합접촉 고려하지 않은 경우와 고려한 경우로 나누어 정리하였다. 결과: 하악 측방운동시 균형측 접촉 고려 유무에 따라 결과에서 많은 차이가 관찰되었으며, 두가지 분류 모두에서 군기능유도가 가장 우세하게 나타났다. 작업측에서는 견치에서 가장 많은 접촉빈도가 관찰되었으며, 견치에서 구치부로 멀어질수록 접촉빈도는 감소하는 양상을 보였다. 균형측에서는 제 2대구치에서 압도적으로 많은 빈도로 관찰되었다. 성별에 따른 균형측 접촉 빈도는 여성에서 더 높은 균형측 교합접촉이 관찰되었으며 이는 통계적으로 유의성이 있었다(${\alpha}$=.05). 결론: 전방유도의 양상 중 군기능유도가 가장 우세하게 나타났다. 작업측에서는 견치에서 가장 높은 접촉빈도가 관찰되었으며, 균형측에서는 제 2 대구치에서 가장 높은 접촉빈도가 관찰되었다.

두부의 자세 변화가 초기 교합접촉에 미치는 영향 (The Effect of Head Posture Change on Initial Occlusal Contacts)

  • Woo-Cheon Kee
    • Journal of Oral Medicine and Pain
    • /
    • 제20권1호
    • /
    • pp.195-204
    • /
    • 1995
  • The purpose of this study was to evaluate effect of head posture change on initial occlusal contacts through measuring the distances between initial occlusal contacts and maximum intercuspal position at different head posture. Two special devices were designed and constructed. Mandibular movement replicator was used to assess reliability of the K6 diagnostic system(MKG; Myo-tronic Inc, Seatle, USA) and head posture calibrator was used to maintain the constant head posture during experiment. We measured difference of distance between initial occlusal contact and maximum intercuspal position with MKG in upright, supine, 45 degrees extension, 30 degrees flexion, 30 degrees right and left bending postion of the head. The Frankfurt horizontal plane was used as a reference plane. 21 adults aged from 23 to 25 were selected, who have normal or class I molar relationship, and have no symptoms on TMJ and masticatory muscles, and have restorations less than 3 surfaces on each tooth, and have no other prosthetic restoration. The obtained results were as follows : The mean absolute distances between initial occlusal contact and maximum intercuspal postion were 0.39(0.18mm in the upright position, 0.65(0.37mm in the supine position, 0.59(0.33mm in the 45 degree extension, 0.70(0.53mm in the 30 degrees flexion, 1.12(1.10mm in the 30 degrees right bending and 1.94(0.67mm in the 30 degrees left bending of the head. The positions of the initial occlusal contacts have a tendency to locate anterior, left and inferior to maximal intercuspal position in upright position, posterior and inferior in supine position and 45 degrees extension, anterior and inferior in 30 degrees flexion, right and inferior in 30 degrees right bending, and left and inferior in 30 degrees left bending of the head. There were significant differences among the initial occlusal contacts in each head postures(P<0.0001). Therefore, we need to check initial occlusal contacts in the altered head posture during occlusal analysis and adjustment of occlusal appliance and dental occlusion for diagnosis and treatment of temporomandibular disorder.

  • PDF

측두악관절 잡음자의 교합접촉에 관한 연구 (A STUDY ON THE OCCLUSAL CONTACT OF THE SUBJECTS WITH TEMPOROMANDIBULAR JOINT SOUND)

  • 윤광현;강동완
    • 대한치과보철학회지
    • /
    • 제31권1호
    • /
    • pp.51-61
    • /
    • 1993
  • The purpose of this study was to evaluate a possible occlusal contributing factor on the pathogenesis of temporomandibular joint sound by a new computer aided method for analysis of occlusal contact. 20 subjects without temporomandibular joint sound as control group and 20 subjects with temporomandibular joint sound as experimental group in the TMJ clinic, dental infirmary, School of Dentistry, Chosun University were selected so as to investigate the distribution and intensity of the bilateral occlusal contacts on silicone rubber bites in habitual intercusal position through a computer aided system. The following results were obtained : 1. The distribution and intensity of the occlusal contact could be analyzed and expressed as color density value per levels by this computer aided method. 2. There was not statistical significance between control and experimental group in total occlusal contacts. 3. There was statistical significance between control and experimental group In the total difference of right and left occlusal contacts.(P<0.05).

  • PDF

저작습관에 따른 교합접촉의 변화양태에 관한 연구 (A Study on the Effects of Chewing Side Preference on the Pattern of Occlusal Contacts)

  • Sun-Oh Kwon;Kyung-Soo Han
    • Journal of Oral Medicine and Pain
    • /
    • 제15권1호
    • /
    • pp.117-124
    • /
    • 1991
  • The purpose of his study was to investigate the variations of occlusal contact pattern according to chewing side preference. The author selected 59 dental students (mean age 23.6 years) who had no signs and symptoms of masticatory disorders and divided into two groups, that is, bilateral chewing side group and unilateral chewing side group, respectively. For recording, T-Scan System(Teksan Inc., USA) was used and the recorded occlusal contacts were examined as to the number of occlusal contacts, points distribution in dental arch, time sequence and force snapshot. The obtained results were as follow s: 1. Total number of occlusal contacts were more in unilateral chewing side group and there were significant difference in number between right and left side or between chewing and less-chewing side in all two groups. 2. All items related to time sequence showed no statistical significant difference between two groups in any case. 3. Unilateral chewing side group had more occlusal contact force than bilateral group, especially in chewing side. From the above finding, the author considered that there was occlusal unbalance in unilateral chewing side group. 4. Chewing side preference would possibly have more effects on the occurrence rate of anterior tooth contact that the rate of prolonged their contact but proved.

  • PDF

Evaluation of biogeneric design techniques with CEREC CAD/CAM system

  • Arslan, Yeliz;Nemli, Secil Karakoca;Gungor, Merve Bankoglu;Tamam, Evsen;Yilmaz, Handan
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권6호
    • /
    • pp.431-436
    • /
    • 2015
  • PURPOSE. The aim of this study was to evaluate occlusal contacts generated by 3 different biogeneric design modes (individual (BI), copy (BC), reference (BR)) of CEREC software and to assess the designs subjectively. MATERIALS AND METHODS. Ten pairs of maxillary and mandibular casts were obtained from full dentate individuals. Gypsum cast contacts were quantified with articulating paper and digital impressions were taken. Then, all ceramic crown preparation was performed on the left first molar teeth and digital impressions of prepared teeth were made. BI, BC, and BR crowns were designed. Occlusal images of designs including occlusal contacts were superimposed on the gypsum cast images and corresponding contacts were determined. Three designs were evaluated by the students. RESULTS. The results of the study revealed that there was significant difference among the number of contacts of gypsum cast and digital models (P<.05). The comparison of the percentage of virtual contacts of three crown designs which were identical to the contacts of original gypsum cast revealed that BI and BR designs showed significantly higher percentages of identical contacts compared with BC design (P<.05). Subjective assessment revealed that students generally found BI designs and BR designs natural regarding naturalness of fissure morphology and cusp shape and cusp tip position. For general occlusal morphology, student groups generally found BI design "too strong" or "perfect", BC design "too weak", and BR design "perfect". CONCLUSION. On a prepared tooth, three different biogeneric design modes of a CAD/CAM software reveals different crown designs regarding occlusal contacts and morphology.

이갈이와 편심위 교합간섭의 상관관계 분석 (A correlation between bruxism and eccentric occlusal interferences)

  • 이호선;김미경;진수윤;김희중;이경제
    • 구강회복응용과학지
    • /
    • 제34권4호
    • /
    • pp.253-261
    • /
    • 2018
  • 목적: 이갈이와 편심위 유도양상 및 균형측 교합간섭과의 연관성에 대해 분석해 보고자 한다. 연구 재료 및 방법: 이갈이와 비이갈이군 및 성별에 따른 군기능 교합 및 균형측 교합간섭의 차이를 비교하고 편심위 유도 양상 및 이갈이와 균형측 교합간섭간의 상관성을 알아보기 위해 제3대구치를 제외한 상실치가 없는 26 - 37세 사이의 100명의 유치악 성인(이갈이군 39명, 비이갈이군 61명)을 대상으로 실험을 하였다. 디지털 교합분석장치 T-Scan system을 이용하여 최대교두감합위, 좌 우측방 편심위 운동을 측정하여 균형측 교합접촉의 유무를 판별하였으며 각 대상의 편심위 교합유도 양상에 대해서도 측정하였다. 디지털 교합분석 장치 검사 후 교합지를 이용하여 접촉되는 치아를 재확인 하였다. 결과: 군기능 교합이 이갈이군에서 61.5%, 비이갈이군에서 47.5%로 가장 높게 나타났다. 남자는 군기능 교합이 58.9%, 여자는 37.0%로 나타났다. 균형측 교합접촉은 전체 100명 중 48명에서 나타났고 이갈이군에서는 51.2%, 비이갈이군에서는 46%였다. 통계적으로 이갈이와 균형측 교합접촉간의 유의성은 나타나지 않았다. 성별에 따른 균형측 교합접촉의 차이도 없었다. 결론: 이갈이와 균형측 교합 접촉간에는 상관관계가 없었다. 이갈이군에서 군기능 교합이 가장 높게 나타났다.

측두하악 장애환자에서 두부자세 변화가 초기 교합접촉에 미치는 영향 (The Effect of Head Posture Change on Initial Occlusal Contact in Temporomandibular Disorder Patient)

  • Weon-Ho Choi;Woo-Cheon Kee
    • Journal of Oral Medicine and Pain
    • /
    • 제20권2호
    • /
    • pp.489-496
    • /
    • 1995
  • The purpose of this study was to evaluate an effect of change on head posture initial occlusal contacts with measuring the distances between initial occlusal contacts and maximum intercuspal position at different head posture in TMDs patient. For this study, 24 patients from age 13 to 36 were selected, they were examined health history taken, patients who have sign and symptoms of TMDs were examine before the study. For the normal group, 21 adults from age 23 to 25 were selected. They have normal or class I molar relationship, and have no other prosthetic restorations. Difference on distance between initial occlusal contact and maximum intercuspal position with mandibular kinesiograph$(MKG^R)$(K6 diagnostic system, Myo-tronic Inc, USA) in upright, supine, 45$^{\circ}$ extension, 30$^{\circ}$ flexion position of the head were measured. The Frankfort horizontal plane was used as a reference plane. The results were as follows : 1. There were significant differences between initial occlusal contacts of the normal and patient group on upright position and 30$^{\circ}$ flexion of the head(p<0.05, p<0.01) 2. The position of the initial occlusal contacts have a tendency to place anterior and inferior to maximal intercuspal position in upright position and 30( flexion of the head as well as posterior and inferior in supine position and 45$^{\circ}$ extension of the head in the normal and patient groups. 3. There were significant differences among the initial occlusal contacts between uptight and supine position; upright and 45$^{\circ}$ extension of the head(p<0.05); supine position and 30$^{\circ}$ flexion of the head, .and 30(flexion and 45$^{\circ}$ extension of the head in the patient group(p<0.01) The result have shown that after treatment on the supine position, it may be necessary to check occlusal contact on the upright position as well ass flexion of the head. It may need careful adjustment in occlusal condition on upright position of TMDs patient.

  • PDF

Comparison of two computerized occlusal analysis systems for indicating occlusal contacts

  • Jeong, Min-Young;Lim, Young-Jun;Kim, Myung-Joo;Kwon, Ho-Beom
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권2호
    • /
    • pp.49-54
    • /
    • 2020
  • PURPOSE. The purpose of this study was to compare the performance of Accura to that of the T-scan for indicating occlusal contacts. MATERIALS AND METHODS. Twenty-four subjects were selected. Their maxillary dental casts were scanned with a model scanner. The Stereolithography files of the casts were positioned to align with the occlusal plane. Occlusal surfaces of every tooth were divided into three to six anatomic regions. T-scan and Accura recordings were made during two masticatory cycles. The T-scan and Accura images were captured at the maximum bite force and overlapped to the cast. Photographs of interocclusal records were used as the reference during overlap. The occlusal contacts were counted to compare the T-scan and Accura. McNemar's test was used for statistical significance and the corresponding P-values were calculated from a chi-square distribution with one degree of freedom. The accuracy, sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of Accura were calculated relative to the T-scan values as a control. RESULTS. No statistical differences (P>.05) were found between the T-scan and Accura methods. The accuracy of Accura was 75.8%, sensitivity was 82.1%, specificity was 60.1%, PPV was 82.9%, and NPV was 60.1%. CONCLUSION. Accura could be another possible option as a computerized occlusal analysis system for indicating occlusal contacts at maximum intercuspation.