• 제목/요약/키워드: Occlusal analysis

검색결과 455건 처리시간 0.018초

악교정수술 후 조기 재수술 증례의 분석 (Clinical analysis of early reoperation cases after orthognathic surgery)

  • 이주환;이인우;서병무
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제36권1호
    • /
    • pp.28-38
    • /
    • 2010
  • The factors influencing the relapse and recurrence of skeletal deformity after the orthognathic surgery include various factors such as condylar deviation, the amount of mandibular set-back, stretching force by the soft tissues and muscles around the facial skeleton. The purpose of this report is to recognize and analyze the possible factors of reoperation after orthognathic surgery, due to early relapses. Six patients underwent reoperation after the orthognathic surgeries out of 110 patients from 2006 to 2009 were included in this study. In most cases, clincal signs of the insufficient occlusal stability, anterior open bite, and unilateral shifting of the mandible were founded within 2 weeks postoperatively. Although elastic traction was initiated in every case, inadequate correction made reoperation for these cases inevitable. The chief complaints of five cases were the protruded mandible combined with some degree of asymmetric face and in the other one case, it was asymmetric face only. Various factors were considered as a major cause of post-operative instability such as condylar sagging, counter-clockwise rotation of the mandibular segment, soft tissue tension related with asymmetrical mandibular set-back, preoperatively existing temporomandibular disorder (TMD), poor fabrication of the final wafer, and dual bite tendency of the patients.

골유착성 치과 임플랜트 고정체 직경에 따른 지지골의 응력분포에 관한 삼차원 유한요소 분석적 연구 (A 3-dimensional Finite Element Analysis of Stress Distribution in the Supporting Bone by Diameters of Dental Implant Fixture)

  • 이명곤
    • 대한치과기공학회지
    • /
    • 제26권1호
    • /
    • pp.69-76
    • /
    • 2004
  • The objective of this finite element method study was to analyze the stress distribution induced on a supporting bone by 3.75mm, 4.0mm, 5.0mm diameter of dental implant fixture(13mm length). 3-dimensional finite element models of simplified gold alloy crown(7mm height) and dental implant structures(gold cylinder screw, gold cylinder, abutment screw, abutment, fixture and supporting bone(cortical bone, cancellous bone) designs were subjected to a simulated biting force of 100 N which was forced over occlusal plane of gold alloy crown vertically. Maximum von Mises stresses(MPa) under vertical loading were 9.693(3.75mm diameter of fixture), 8.885(4.0mm diameter of fixture), 6.301(5.0mm diameter of fixture) and the highest von Mises stresses of all models were concentrated in the surrounding crestal cortical bone. The wide diameter implant was the good choice for minimizing cortical bone-fixture interface stress.

  • PDF

코핑 두께의 차이에 따른 POM 보철물의 변연적합도 연구 (Comparison of the marginal fit of POM restorations with different thickness of metal copings)

  • 임형택
    • 대한치과기공학회지
    • /
    • 제34권2호
    • /
    • pp.135-143
    • /
    • 2012
  • Purpose: The purpose of this in vitro study was to compare the marginal fit of POM restorations with 3 different thickness of metal coping. Methods: 2.0mm Occlusal reduction, 1.0mm preparation of axial wall with 6degree taper, and chamfer margin was prepared a maxillary first premolar on dentiform. Duplicate prepared die and, make 30 individual dies with Ni-Cr metal. Make 3 groups of 30 press ceramic on Metal crown with different thickness of metal coping; 10 of 0.1mm, 10 of 0.3mm, 10 of 0.5mm thickness metal coping. The marginal fit of the crowns was evaluated 50 points per 1 crown, around the crown margin circumference under a optical microscope at original magnification ${\times}100$. A 1-way analysis of variance (ANOVA) was used to compare data. Results: The mean marginal discrepancy for POM with 0.1mm metal copings was $72.56{\mu}m$, $67.83{\mu}m$ for 0.3mm metal coping POMs, and $72.56{\mu}m$ for 0.5mm metal coping POM. The 1-way ANOVA showed significant difference among 3 groups. Conclusion: The marginal fit of pressed-on-metal (POMs) was best with 0.3mm thickness of metal coping, fallowing by 0.1mm, and 0.5mm in the order.

3차원 유한요소해석을 이용한 비우식성 치아의 수복 방법 (An Optimal Restoration Method of Noncarious Cervical Lesions Using Three-Dimensional Finite Element Analysis)

  • 우성관;김광훈;박정길;허복;손권
    • 한국정밀공학회지
    • /
    • 제24권7호
    • /
    • pp.112-119
    • /
    • 2007
  • Cavities of Class V are caused by heavy occlusal loads due to bruxism and clenching habit. It is general to restore abfraction lesions with dental filler materials to reduce stress concentration. A material should be selected from various dental products based on long term clinical experiences or personal preference concerning filler methods. A quantitative criterion is necessary to make an evaluation of the results as dentists decide treatment methods and dental materials relying on their clinical experiences. The purpose of this study is to find an optimal restoration method and material for noncarious cervical lesions using the finite element method. An objective function was defined to minimize the sum of tensile and compressive stresses. Several models with different combinations of resins were suggested and compared in terms of the values of objective function. An optimal solution was to fill TetricFlow inside the lesion and Z100 in the remaining region with a thickness ratio of 0.125.

구치부(臼齒部) 도재전장주조관(陶在前裝鑄造冠) 변연형태(邊緣形態)에 따른 응력분석(應力分析) (Stress Analysis of Posterior Porcelain-Fused-to-Metal Crown by Marginal Configurations)

  • 김광석;송광엽;박찬운
    • 대한치과보철학회지
    • /
    • 제25권1호
    • /
    • pp.161-179
    • /
    • 1987
  • To study the mechanical behaviors of the margins of porcelain-fused-to-metal crown on the posterior teeth, 5 types of margins on the lower first molar were chosen, and then the finite element models were constructed. 50kg forces were applied to the porcelain on the axial wall supported by the metal vertically. The displacements and stresses of the porcelain-fused-to-metal crown were analyzed to investigate the influence of the type of margins. The results were as follows; 1. High tensile stresses were exhibited on the porcelain of the portion of the coronal line angle insufficient metallic support. 2. In case metal coping had a good supporting form to vertical force, uniform compressive stresses were exhibited on their supporting form. 3. Tensile stresses in the inframetallic margin on the series of the shoulder with a bevel margins were decreased in the bevel portion. 4. Principal stresses on the metal of the chamfer marginal portion were decreased comparing with the series of the shoulder margins. 5. The noticeable compressive stress gradients were exhibited between axial cement layer and metal on the series of the shoulder margins. 6. The principal stresses on the marginal cement layer were higher than that of the occlusal surface and axial wall.

  • PDF

구내디지털방사선영상의 JPEG와 wavelet 압축방법 비교 (Comparison of JPEG and wavelet compression on intraoral digital radiographic images)

  • 김은경
    • Imaging Science in Dentistry
    • /
    • 제34권3호
    • /
    • pp.117-122
    • /
    • 2004
  • Purpose : To determine the proper image compression method and ratio without image quality degradation in intraoral digital radiographic images, comparing the discrete cosine transform (DCT)-based JPEG with the wavelet-based JPEG 2000 algorithm. Materials and Methods : Thirty extracted sound teeth and thirty extracted teeth with occlusal caries were used for this study. Twenty plaster blocks were made with three teeth each. They were radiographically exposed using CDR sensors (Schick Inc., Long Island, USA). Digital images were compressed to JPEG format, using Adobe Photoshop v.7.0 and JPEG 2000 format using Jasper program with compression ratios of 5 : 1,9 : 1, 14 : 1,28 : 1 each. To evaluate the lesion detectability, receiver operating characteristic (ROC) analysis was performed by the three oral and maxillofacial radiologists. To evaluate the image quality, all the compressed images were assessed subjectively using 5 grades, in comparison to the original uncompressed images. Results: Compressed images up to compression ratio of 14 : 1 in JPEG and 28 : 1 in JPEG 2000 showed nearly the same the lesion detectability as the original images. In the subjective assessment of image quality, images up to compression ratio of 9 : 1 in JPEG and 14 : 1 in JPEG 2000 showed minute mean paired differences from the original Images. Conclusion : The results showed that the clinically acceptable compression ratios were up to 9 : 1 for JPEG and 14 : 1 for JPEG 2000. The wavelet-based JPEG 2000 is a better compression method, comparing to DCT-based JPEG for intraoral digital radiographic images.

  • PDF

두부규격방사선사진과 측두하악관절 단층방사선사진 계측치간의 상관관계 (Relation of the measuring values in cephalometric radiographs and TMJ tomographs)

  • 한진우
    • Imaging Science in Dentistry
    • /
    • 제37권1호
    • /
    • pp.19-26
    • /
    • 2007
  • Purpose : To examine whether the maxillofacial skeletal morphology correlates with the condylar position and the anatomic characteristics of articular eminence using measurements of lateral cephalometric radiographs and individualized sagittal temporomandibular joint (TMJ) tomographs. Materials and Methods : I compared measurements of 202 TMJs of 101 orthodontic patients of Kangnung National University Dental Hospital. 1 used Pearson's correlation for comparison of the measuring values in lateral cephalometric radiographs and individualized sagittal TMJ tomographs. Results : Large occlusal plane angle tendency showed decreased width of posterior eminence slope, decreased depth of articular fossa and decreased posterior slope angle of eminence. Large mandibular plane angle tendency showed decreased superior joint space, decreased depth of articular fossa and decreased posterior slope angle of eminence. Large genial angle tendency showed decreased depth of articular fossa, decreased posterior slope angle of eminence and anterior position of condylar head. Large anterior facial height and large posterior facial height tendency showed increased width of posterior slope of eminence, increased depth of articular fossa, increased posterior slope angle of eminence and posterior position of condylar head. Conclusion : Maxillofacial skeletal morphology has correlation with the anatomic characteristics of TMJ. Individualized sagittal TMJ tomographs can provide useful information for anatomical analysis of TMJ.

  • PDF

Clinical gap changes after porcelain firing cycles of zirconia fixed dentures

  • Bugurman, Bugurman Burcu;Turker, Sebnem Begum
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권3호
    • /
    • pp.177-184
    • /
    • 2014
  • PURPOSE. The aim of this study was to measure the changes on the marginal and internal adaptation of zirconia based anterior fixed partial dentures after the porcelain firing process. MATERIALS AND METHODS. A total of 34 anterior fixed partial dentures using LAVA CAD/CAM system (3M ESPE, Germany) were applied. Two silicone replicas were obtained: one is obtained before porcelain firing process (initial) and the other is obtained after porcelain firing process (final), followed by the examination under a binocular stereomicroscope. Kruskal Wallis and Wilcoxon Signed Ranks tests were used for the statistical analysis (P<.05). RESULTS. No statistically significant difference was found between initial and final marginal gap values (P>.05). At the internal gap measurements, final marginal area values ($59.54{\mu}m$) were significantly lower than the initial marginal area values ($68.68{\mu}m$)(P<.05). The highest and the lowest internal gap values were observed at the incisal/occlusal area and at the marginal area, respectively. In addition, lower internal gap values were obtained for canines than for central incisors, lateral incisors and premolars at the incisal area (P<.05). CONCLUSION. The firing cycles did not affect the marginal gap of Lava CAD/CAM system, but it is controversial for the internal gap.

내측연결 시스템에서 임플란트 고정체의 경부 형태에 따른 지지골에서의 유한요소 응력분석 (Finite Element Stress Analysis in Supporting Bone according to Crest Module Shape of Fixture in Internal Connection System)

  • 박영남;김희중;오상호;정재헌
    • 구강회복응용과학지
    • /
    • 제22권1호
    • /
    • pp.55-74
    • /
    • 2006
  • The external contour of an implant can have significant effects on the load transfer characteristics and may result in different bone failure rates for different implant system. The purpose of this study was to investigate the effects of crest module shape and occlusal load direction on bone failure modes of five commercially available dental implant systems. Five different implant systems with internal connection; ITI (Model 1), Astra (Model 2), Bicon (Model 3), Friadent (Model 4), and Paragon (Model 5), comparable in size, but different in thread profile and cest module shapes, were compared using the finite element method. Conclusively, in the internal connection system of the implant-abutment connection methods, the stress-induced pattern at the supporting bone according to the abutment connection form had differenence among them, and implants with narrowing crestal module cross-sections at the top of the cortical bone created more favorable load transfer characteristics in this region. But it is considered that the future study is necessary about how this difference in the magnitude of the stress have an effect on the practical clinic.

교합이 악구강계 및 전신에 미치는 영향 (III) -카이로돈틱과 치아 스트레스 원인 증후군 및 Quadrant Theorem을 중심으로- (Dental Occlusion and Relationship to TMD and Systemic Symptoms (III) -Chirodontics, Dental Distress Syndrome(DDS), Quadrant Theorem-)

  • 박은진;최병갑;배은경
    • 구강회복응용과학지
    • /
    • 제26권2호
    • /
    • pp.89-95
    • /
    • 2010
  • 본 연구는 앞서 발표된 '교합이 악구강계 및 전신에 미치는 영향 (I), (II)'에서 연결되는 세 번째 논문으로 교합과 악구강계 및 전신 증상과의 관계를 다루고 있는 다섯 가지 주요 이론 중 두 가지인 Chirodontics, Dental Distress Syndrome and Quadrant Theorem에 관한 내용이다. 앞서 발표되었던 논문과 비슷한 방식으로 각각의 이론에 대한 역사적 배경과 정의, 기본 개념과 치료방법 및 그 한계에 대하여 보고하고자 한다.