• 제목/요약/키워드: Occlusal/Axial thickness

검색결과 11건 처리시간 0.033초

Fracture load and survival of anatomically representative monolithic lithium disilicate crowns with reduced tooth preparation and ceramic thickness

  • Nawafleh, Noor A;Hatamleh, Muhanad M;Ochsner, Andreas;Mack, Florian
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권6호
    • /
    • pp.416-422
    • /
    • 2017
  • PURPOSE. To investigate the effect of reducing tooth preparation and ceramic thickness on fracture resistance of lithium disilicate crowns. MATERIALS AND METHODS. Specimen preparation included a standard complete crown preparation of a typodont mandibular left first molar with an occlusal reduction of 2 mm, proximal/axial wall reduction of 1.5 mm, and 1.0 mm deep chamfer (Group A). Another typodont mandibular first molar was prepared with less tooth reduction: 1 mm occlusal and proximal/axial wall reduction and 0.8 mm chamfer (Group B). Twenty crowns were milled from each preparation corresponding to control group (n=5) and conditioned group of simultaneous thermal and mechanical loading in aqueous environment (n=15). All crowns were then loaded until fracture to determine the fracture load. RESULTS. The mean (SD) fracture load values (in Newton) for Group A were 2340 (83) and 2149 (649), and for Group B, 1752 (134) and 1054 (249) without and with fatigue, respectively. Reducing tooth preparation thickness significantly decreased fracture load of the crowns at baseline and after fatigue application. After fatigue, the mean fracture load statistically significantly decreased (P<.001) in Group B; however, it was not affected (P>.05) in Group A. CONCLUSION. Reducing the amount of tooth preparation by 0.5 mm on the occlusal and proximal/axial wall with a 0.8 mm chamfer significantly reduced fracture load of the restoration. Tooth reduction required for lithium disilicate crowns is a crucial factor for a long-term successful application of this all-ceramic system.

다양한 부위에서의 감소된 두께가 지르코니아 크라운의 파절 저항에 미치는 영향 (The effect of reduced thickness in different regions on the fracture resistance of monolithic zirconia crowns)

  • 라일라 아부카보스;박재억;이원섭
    • 대한치과보철학회지
    • /
    • 제60권2호
    • /
    • pp.135-142
    • /
    • 2022
  • 목적: 이번 연구의 목적은 단일구조 지르코니아(monolithic zirconia) 크라운의 서로 다른 부위에서, 감소된 지르코니아의 두께가 파절 저항성에 미치는 복합적인 영향을 평가하기 위한 것이다. 재료 및 방법: 실험을 위해 7개의 니켈-크롬 다이를 제작하였다. 다이는 하악 제 1대구치를 치아 형성한 지대치 3D 모델을 바탕으로 제작되었다. 지대치는 1.5 mm 교합면 삭제를 시행하였고, 변연은 1.0 mm의 deep chamfer로 형성하였다. 이 지대치 형태를 바탕으로 지르코니아 블록(Luxen Zirconia)를 사용하여, 교합면 두께는 0.3 mm, 0.5 mm, 1.5 mm, 축면 두께는 0.3 mm, 0.5 mm, 1.0 mm로 설정한 63개의 지르코니아 크라운을 제작하였다. 이 크라운은 니켈 크롬 다이에 레진 시멘트를 이용하여 접착하였다. 그 다음, electronic universal testing machine을 사용하여 크라운이 파절될 때까지 load-to fracture 시험을 진행하였다. 이후 scanning electron microscope (SEM)를 사용하여 크라운의 파절 형태를 관찰하였다. 통계 분석을 위해 Two-way ANOVA 방법을 사용하였고, 이에 대하여 Tuckey HSD test로 사후 검정을 시행하였다(P < .05). 결과: 모든 지르코니아 크라운의 평균 파절 저항 값은 구치부의 평균 저작력보다 큰 값을 나타냈다. 또한 Two-way ANOVA 결과, 지르코니아 크라운의 교합면 두께와 축면 두께는 파절 저항에 통계적으로 유의한 영향을 미치는 것으로 나타났다(P < .05). 그러나, 지르코니아의 축면 두께가 0.5 mm 이상일 때, 파절 저항에 미치는 영향은 통계적으로 유의한 차이를 보이지 않았다. 나타난 파괴 양상은 균열의 전파 양상에 따라 크라운의 부분 파절 또는 완전 파절로 나타났다. 결론: 이번 연구의 한계 내에서, 극도로 감소된 두께를 가진 CAD-CAM 단일구조 지르코니아 크라운은 구치부 교합력을 견딜 수 있는 적절한 파절 저항을 보였다. 또한, 지르코니아 크라운의 교합면 두께와 축면 두께는 파절 저항에 유의미한 영향을 나타냈으며 복합적인 결과를 보였다.

Ceromer crown의 교합면 두께에 따른 압축 파절 강도의 비교 (The compressive fracture strength of ceromer crown by the difference of occlusal thickness)

  • 김지연;박하옥;양홍서
    • 구강회복응용과학지
    • /
    • 제18권3호
    • /
    • pp.205-215
    • /
    • 2002
  • This study investigated the compressive fracture strength of Targis ceromer crown by the difference of occlusal thickness on a maxillary first premolar. Control group was a castable IPS-Empress all-ceramic crown with occlusal thickness of 1.5 mm constructed by layered technique. Experimental groups were Targis crowns having different occlusal thicknesses of 1.0 mm, 1.5 mm, 2.0 mm, 2.5 mm, respectively. The classification of Targis group is T10, T15, T20, T25 and T15N (for no-thermocycling and occlusal thickness of 1.5mm). Ten samples were tested per each group. Except occlusal thickness, all dimension of metal die is same with axial inclination of $10^{\circ}$and marginal width 0.8mm chamfer. All crowns were cemented with Panavia F and thermocycled 1,000 times between $5^{\circ}$ and $55^{\circ}$ water bath with 10 sec dwelling time and 10 sec resting time. The compressive fracture strength was measured by universal testing machine. The results were as follows : 1. Fracture strength was increased as the occlusal thickness increased : compressive fracture strength of Group T10, T15, T20, T25 was $66.65{\pm}4.88kgf$, $75.04{\pm}3.01kgf$, $87.07{\pm}7.06kgf$ and $105.03{\pm}10.56kgf$, respectively. 2. When comparing material, Targis crown had higher fracture strength than IPS-Empress crown : the mean compressive strength of group T15 was $75.04{\pm}3.01kgf$ and the value of group Control was $37.66{\pm}4.28kgf$. 3. Fracture strength was decreased by thermocycling : the compressive fracture strength of T15 was $75.04{\pm}3.01kgf$, which is lower than $90.69{\pm}6.88kgf$ of group T15N. 4. The fracture line of crowns began at the loading point and extended along long axis of tooth. IPS-Empress showed adhesive failure pattern whereas Targis had adhesive and cohesive failure. In the SEM view, stress was distributed radially from loading point and the crack line was more prominent on Targis crown.

완전 지르코니아 크라운의 교합면 두께에 따른 파절강도의 비교 연구 (Comparative study of fracture strength depending on the occlusal thickness of full zirconia crown)

  • 장수아;김윤영;박원희;이영수
    • 대한치과보철학회지
    • /
    • 제51권3호
    • /
    • pp.160-166
    • /
    • 2013
  • 연구 목적: 본 연구의 목적은 전통적인 금속도재관과 완전 지르코니아 크라운의 교합면 두께에 따른 파절강도를 비교하는 것이다. 연구 재료 및 방법: 하악 제1대구치에 해당하는 레진치를 교합면 1.5 mm, 변연은 1.0 mm 폭의 rounded shoulder로 하고 축면 경사각이 $6^{\circ}$가 되도록 삭제하여 금속 다이 64개를 제작하였다. 완전 지르코니아 크라운은ZIRKONZAHN CAD/CAM을 이용하여 Prettau zirconia blanks를 절삭하여 48개의 크라운을 제작하고 교합면 교두정의 두께에 따라 6개 군으로 분류하였다(0.5 mm, 0.6 mm, 0.7 mm, 0.8 mm, 0.9 mm, 1.0 mm). 16개의 금속도재관을 제작하여 교합면 교두정 도재의 두께에 따라 2개 군으로 분류하였다(1.0 mm, 1.5 mm). 완성된 완전 지르코니아 크라운과 금속도재관은 만능시험기 상에서 치아 교합면에 수직으로 하중이 가하도록 하여 파절강도를 측정하였다. One-way ANOVA, Tukey multiple comparison test (${\alpha}=.05$)와 t-test (${\alpha}=.05$)로 검정하였다. 결과: 본 연구의 결과는 다음과 같다. 1. 실험 1군은 가장 낮은 값(646.48 N)을 나타내었고(P<.05), 실험 2, 3, 4, 5군은 교합면의 두께가 증가할수록 파절강도는 증가하였지만 (866.40 N, 978.82 N, 1196.82 N, 1222.41 N) 통계적으로 유의한 차이를 나타내지 않았다(P>.05). 실험 6군은 다른 군보다 통계적으로 유의하게 가장 높은 값(1781.24 N)을 나타내었다(P<.05). 2. 대조군의 파절강도는 도재의 두께가 1.0 mm와 1.5 mm일때각각2515.71 N, 3473.31 N이며 이는 통계적으로 유의한 차이를 나타내지 않았다(P>.05). 결론: 완전 지르코니아 크라운은 대구치부에서 최대교합력보다 높은 파절강도를 갖기 위해서는 1.0 mm이상의 두께가 필요하다.

코핑 두께의 차이에 따른 POM 보철물의 변연적합도 연구 (Comparison of the marginal fit of POM restorations with different thickness of metal copings)

  • 임형택
    • 대한치과기공학회지
    • /
    • 제34권2호
    • /
    • pp.135-143
    • /
    • 2012
  • Purpose: The purpose of this in vitro study was to compare the marginal fit of POM restorations with 3 different thickness of metal coping. Methods: 2.0mm Occlusal reduction, 1.0mm preparation of axial wall with 6degree taper, and chamfer margin was prepared a maxillary first premolar on dentiform. Duplicate prepared die and, make 30 individual dies with Ni-Cr metal. Make 3 groups of 30 press ceramic on Metal crown with different thickness of metal coping; 10 of 0.1mm, 10 of 0.3mm, 10 of 0.5mm thickness metal coping. The marginal fit of the crowns was evaluated 50 points per 1 crown, around the crown margin circumference under a optical microscope at original magnification ${\times}100$. A 1-way analysis of variance (ANOVA) was used to compare data. Results: The mean marginal discrepancy for POM with 0.1mm metal copings was $72.56{\mu}m$, $67.83{\mu}m$ for 0.3mm metal coping POMs, and $72.56{\mu}m$ for 0.5mm metal coping POM. The 1-way ANOVA showed significant difference among 3 groups. Conclusion: The marginal fit of pressed-on-metal (POMs) was best with 0.3mm thickness of metal coping, fallowing by 0.1mm, and 0.5mm in the order.

하악전돌증에 있어서 전산화단층촬영을 이용한 하악지의 형태학적 평가 (MORPHOLOGICAL EVALUATION OF MANDIBULAR RAMUS IN MANDIBULAR PROGNATHISM BY COMPUTED TOMOGRAPHY)

  • 차두원;장지영;이상한
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제34권3호
    • /
    • pp.370-375
    • /
    • 2008
  • Sagittal split ramus osteotomy (SSRO) is widely used in treatment of dentofacial deformities. But, many complications can occur including unfavorable fractures during osteotomy. To prevent these complications, it is necessary to understand comprehensively the anatomy of the mandiular ramus. The purpose of this study was to evaluate the morphology of the madibular ramus in manibular prognathism patients by computed tomography comparing with normal control group. The study group consisted of 33 skeletal class III patients (20 males, 13 females) and the control group consisted of the 52 patients without dentofacial deformities (32 males, 20 females). The mean age of study group was 22.0-year old, and that of control group was 37.1-year. For the CT examination, following scan parameters was used: 1mm slice thickness, 0.5 second scan time, 120kV and 100mA/s. The axial scans of the head were made parallel to the mandibular occlusal plane. The anteroposterior length of the ramus, the distance from anterior border of the ramus to lingula, the relative distance from the anterior border of the ramus to lingula compared to the anteroposterior length of the ramus, the thickness of anterior and posterior cortical plate, the thickness of medial cortical plate of the ramus at lingula level, the thickness of cancellous bone of the ramus at lingula level were measured. The skeletal class III mandibular prognathism patients exhibited shorter anteroposterior length of the ramus, thicker anterior and posterior cortical plate, thinner mediolateral cancellous bone thickness. The lingula has a relative stable anteroposterior position in ramus in all groups. There was higher possibility of fusion of medial and lateral cortical plate at lingula level in the mandibular prognathism group. In conclusion, the mandibular prognathism patients have narrow rami with scanty cancellous bone, which means that careful preoperative examination including CT scan can prevent undesirable fractures during osteotomy.

하악과두에 발생된 골연골증 (OSTEOCHONDROMA OF THE MANDIBULAR CONDYLE)

  • 정기훈;김은경
    • 치과방사선
    • /
    • 제23권2호
    • /
    • pp.373-378
    • /
    • 1993
  • 저자들은 희귀한 하악과두의 골연골종으로 진단 내려진 27세 남성 환자에서 아래와 같은 사항을 관찰하였다. 1. 임상적으로 좌측안면부의 비대칭과, 교합이상 그리고 저작 시 좌측 악관절의 동통이 있었다. 2. 방사선학적으로 좌측과두에 내측으로 균일한 방사선불투과성의 종괴가 보였으며, 좌측 하악지 길이의 증가 및 우측으로의 하악 변위가 관찰되었다. 또 골스캔상에서 좌측 악관절부위의 hot spot이 관찰되었다. 3. 조직병리학적으로 불규칙한 골의 형성과 연골모를 볼 수 있었다.

  • PDF

시멘트 공간이 캐드캠 시스템으로 제작한 지르코니아 수복물의 변연과 내부 적합도에 미치는 효과 (Effect of cement space on the marginal and internal fit of zirconia restorations fabricated by CAD/CAM system)

  • 이정환;안재석
    • 대한치과기공학회지
    • /
    • 제39권4호
    • /
    • pp.235-242
    • /
    • 2017
  • Purpose: The aim of this study was to evaluate the marginal and internal gap of zirconia copings fabricated by CAD/CAM system and to research the effect of cement space on the fit of zirconia prosthesis. Methods: Zirconia copings were designed using 3shape software and then milled from presintered zirconia blocks by Kavo dental milling machine. The cement space was set at $0{\mu}m$ around the margins for all groups, and additional cement space appling 1 mm above the finish lines of tooth. The samples were classified into 4 groups according to the cement space setting(Cs-0, Cs-40, Cs-80, Cs-120). Replica technique used to investigate marginal and internal gap. The silicone film thickness was recorded using a optical microscope with image software analysis system at 75${\times}$magnification. The assessment performed on the six points in bucco-lingual and mesio-distal sections(4 groups, 10 copings per group, 12 measuring points per coping). The data were statistically analyzed with one-way ANOVA followed by pair-wise Tukey's post hoc tests(${\alpha}$<0.05). Results: Better marginal and internal fit values were exhibited by $80{\mu}m$ cement space. The results showed that different cement space values had statistically significant effect on the marginal and internal gap of zirconia copings(p<0.001). The gap of margin and axial wall area was smaller than that the gap of occlusal area in all groups(p<0.001). Conclusion : Effect of different cement spaces on the marginal and internal gap of zirconia copings.

Marginal and internal fit of 3D printed provisional crowns according to build directions

  • Ryu, Ji-Eun;Kim, Yu-Lee;Kong, Hyun-Jun;Chang, Hoon-Sang;Jung, Ji-Hye
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권4호
    • /
    • pp.225-232
    • /
    • 2020
  • PURPOSE. This study aimed to fabricate provisional crowns at varying build directions using the digital light processing (DLP)-based 3D printing and evaluate the marginal and internal fit of the provisional crowns using the silicone replica technique (SRT). MATERIALS AND METHODS. The prepared resin tooth was scanned and a single crown was designed using computer-aided design (CAD) software. Provisional crowns were printed using a DLP-based 3D printer at 6 directions (120°, 135°, 150°, 180°, 210°, 225°) with 10 crowns in each direction. In total, sixty crowns were printed. To measure the marginal and internal fit, a silicone replica was fabricated and the thickness of the silicone impression material was measured using a digital microscope. Sixteen reference points were set and divided into the following 4 groups: marginal gap (MG), cervical gap (CG), axial gap (AG), and occlusal gap (OG). The measurements were statistically analyzed using one-way ANOVA and Dunnett T3. RESULTS. MG, CG, and OG were significantly different by build angle groups (P<.05). The MG and CG were significantly larger in the 120° group than in other groups. OG was the smallest in the 150° and 180° and the largest in the 120° and 135° groups. CONCLUSION. The marginal and internal fit of the 3D-printed provisional crowns can vary depending on the build angle and the best fit was achieved with build angles of 150° and 180°.

세척 방법 및 세척 시간에 따른 3D 프린팅 방식으로 제작된 임시 보철물의 변연 및 내면 적합도 평가 (Evaluation of Marginal and Internal Gap of Temporary Prosthesis Fabricated by 3D Printing Method According to Rinsing Method and Rinsing Time)

  • 배지현;최재원
    • 한국산업융합학회 논문집
    • /
    • 제26권4_2호
    • /
    • pp.561-570
    • /
    • 2023
  • This study was to evaluate the effect of different rinsing times and methods on the accuracy of temporary prostheses fabricated by 3D printing method. Sixty temporary prostheses were fabricated with LCD types of 3D printer(Halot-Sky, Creality, Shenzhen, China) and divided into six groups (n = 10) based on rinsing times and methods. All specimens were rinsed with 99% isopropanol alcohol for 5 and 10 min using three methods-hand washed, ultrasonic cleaning, and automated washing. All specimens were polymerized for 3 minutes under the same conditions. The marginal and internal gaps of specimens were examined using a replica technique. The light-body silicone thickness was measured at 6 reference points(Absolute marginal discrepancy, Marginal, Chamfer, Axial, Angle, and Occlusal gap). All measurements were performed by a stereomicroscope. Reference point images were taken at 100× magnification and then measured using an image analysis program. Statistical analysis was performed using Two-way ANOVA, One-way ANOVA, and the Kruskal-Wallis test (p = .05). The marginal and internal gaps were statistically different according to the rinsing methods and rinsing times(p < .001). In the rinsing time, the temporary prosthesis rinsed for 5 minutes group showed higher accuracy than 10 minutes group. In the rinsing method, the hand washing group showed higher accuracy than the automated washing group.