• Title/Summary/Keyword: Observation type

Search Result 1,403, Processing Time 0.03 seconds

Pore Structure Modification and Characterization of Porous Alumina Filter with Chemical Vapor Infiltration (CVI) SiC Whisker (화학증착 탄화규소 휘스커에 의한 다공성 알루미나 필터의 기공구조 개질 및 특성 평가)

  • 박원순;최두진;김해두
    • Journal of the Korean Ceramic Society
    • /
    • v.41 no.7
    • /
    • pp.518-527
    • /
    • 2004
  • In this study, SiC whiskers were grown in porous alumina substrate in order to enhance the filtering efficiency, performance, and durability by controlling pore morphology. This experiment was performed by Chemical Vapor Infiltration (CVI) in order to obtain the whiskers on the inside of pores as well as on the surface of porous the A1$_2$O$_3$ substrate. The deposition behavior was changed remarkably with the deposition position, temperature, and input gas ratio. First, the mean diameter of whisker was decreased as the position of observation moved into the inside of substrate due to the reactant gas depletion effect'. Second, the deposition temperature caused the changes of the deposition type such as debris, whiskers and films and the change in morphology affect the various properties. When SiC films were deposited. the gas permeability and the specific surface area decreased. However, the whisker showed the opposite result. The whiskers increase not only the specific surface area and minimizing pressure drop but also mechanical strength. Therefore it is expected that the porous alumina body which deposited the SiC whisker is the promising material for the filter trapping the particles.

The Observation of Scattering Patterns During Membrane Formation: Spinodal Decomposition and Nucleation Growth (스피노달 분해와 기핵성장에 따른 상분리 과정의 광산란 패턴의 관찰)

  • Kang, Jong-Seok;Huh, Hoon;Lee, Young-Moo
    • Membrane Journal
    • /
    • v.12 no.2
    • /
    • pp.97-106
    • /
    • 2002
  • Small angle light scattering (SALS) and field emission scanning electron microscope (FE-SEM) have been used to investigate the light scattering patterns with time evolved during water vapor quenching (relative humidity of 53 (${\pm}3)%$ at $26^{\circ}C$ of polysulfone (PSf)/NMP/Alcohol and chlorinated poly(vinyl chloride) (CPVC)/THF/Alcohol, respective1y. Time dependence of the position of the light scattering maximum was observed at PSf dope solutions, confirming spinodal decomposition (SD), while CPVC dope solutions showed a decreased scattered light intensity with an increased q-value, indicating nucleation & growth (NG). For the each system, domain growth rate in the intermediate and late stage of phase separation decreased with increasing the number of carbon of alcohol used as additive (non-solvent). Also, in the early stage for SD, the scattering intensity with time was in accordance with Cahn's linear theory of spinodal decomposition, regardless of types of non-solvent additive. Also, the size scales obtained by SALS were mutually compared to domain sizes gained by FE-SEM measurement. These observations of scattering pattern were much clearly observed for the 20PSf/70NMP/10n-butanol (w/w%) and agreed with the theoretical predictions for scattering patterns of each stage like the early, the intermediate, and the late stage of SD type phase separation. As the scattering maximum was observed at the larger angles (larger q) in the order of n-butanol > n-propanol > methanol > no alcohol, the pore size of final morphology decreased.

A Study on the Development of GIS based Integrated Information System for Water Quality Management of Yeongsan River Estuary (영산강 하구역 수질환경 관리를 위한 GIS기반 통합정보시스템 개발에 관한 연구)

  • Lee, Sung Joo;Kim, Kye Hyun;Park, Young Gil;Lee, Geon Hwi;Yoo, Jea Hyun
    • Journal of Wetlands Research
    • /
    • v.16 no.1
    • /
    • pp.73-83
    • /
    • 2014
  • The government has recently carried out monitoring to attain a better understanding of the current situation and model for prediction of future events pertaining to water quality in the estuarine area of Yeongsan River. But many users have noted difficulties to understand and utilize the results because most monitoring and model data consist of figures and text. The aim of this study is to develop a GIS-based integrated information system to support the understanding of the current situation and prediction of future events about water quality in the estuarine area of Yeongsan River. To achieve this, a monitoring DB is assembled, a linkages model is defined, a GUI is composed, and the system development environment and system composition are defined. The monitoring data consisted of observation data from 2010 ~ 2012 in the estuarine area of Yeongsan River. The models used in the study are HSPF (Hydrological Simulation Program-Fortran) for simulation of the basin and EFDC (Environmental Fluid Dynamics Code) for simulation of the estuary and river. Ultimately, a GIS based system was presented for utilization and expression using monitoring and model data. The system supports prediction of the estuarine area ecological environment quantitatively and displays document type model simulation results in a map-based environment to enhance the user's spatial understanding. In future study, the system will be updated to include a decision making support system that is capable of handling estuary environment issues and support environmental assessment and development of related policies.

The Clinical Observation of Facial Palsy Sequela (안면신경마비 후유증에 대한 임상적 고찰)

  • 김남권
    • The Journal of Korean Medicine
    • /
    • v.23 no.1
    • /
    • pp.100-111
    • /
    • 2002
  • Objectives : In order to obtain the clinical type of facial palsy sequelae and try to make the treatment protocols for each, I observed patients who visited Gunpo-Wonkwang oriental medicine center with Bell’s palsy sequelae that were treated over three months. Methods : I make the value standard of muscle paralysis, contraction, synkinesis and acquired the results as follows. Results and Conclusions : 1. The distribution of age and sex was as follows : females of 41-50 years were the most common demographic, females of 51-60 years and males of 31-40 years were the second, males of 51-60 years were the third, females of 21-30 years and males of over 60 years were the fourth, and males of 41-50 years were the fifth. 2. The distributions of period of disease were as follows : 3-6 months was the most, 12-18 months was the second, 6-12 months and over 24 months was the third, and 18-24 months was the fourth. 3. The sequelae distributions of disease were as follows. In the group of 3-6 months, 12 persons (80%) showed palsy and atrophy, 10 persons (66.6%) showed synkinetics. In the group of over 6 months, all patients showed muscle palsy, muscle atrophy and synkinetics. All groups showed lower sensitivity of muscles, but the group of 18-24 months and the group of over 24 months showed more. Tinnitus was shown by the groups of 12-18 months and 3-6 months. Facial muscle pain was shown by the group of3-6 months only, Crocodile's tear was shown by the groups of 18-24 months and over 24 months. 4. The total palsy rates of sequela patients and palsy rates by muscle for disease period were as follows. The total palsy rate was 27.94%; the palsy rates for the group of 6-12 months and the group of over 24 months was lower than the total palsy rate. The rates of the groups of 3-6, 12-18, 18-24 months were higher than the total palsy rate. The palsy rate of zygomatic minor, levator labii superior muscle was higher than the total palsy rate for all groups. 5. Synkinetics manifestation rates by disease period were as follows. Total synkinetics manifestation rate was 73.81 %; the manifestation rate of the group of 6-12 months was lower than total synkinetics manifestation rate. For the groups of 12-18, 18-24, and over 24 months it was more than the total synkinetics manifestation rate. The group of over 24 months, total synkinetics induced by orbicularis oculi muscle and orbicularis oris muscle. 6. Facial muscle atrophy rates by disease period were as follows. Total atrophy rate was 5.26%; in the groups of 6-12, 18-24, over 24 months, the atrophy rates were higher than the total atrophy rate. The groups of 3-6 and 12-18 months showed lower than the total atrophy rates, while the atrophy of the levator palpebrae superioris muscle and levator palpebrae inferioris muscle was higher than in other groups.

  • PDF

A Study on the Mechanical Properties of AC8A/$Al_2O_3$ Composites. (용탕단조법에 의한 AC8A/$Al_2O_3$ 복합재료의 기계적 성질에 관한 연구)

  • Kim, Ki-Bae;Kim, Kyoung-Min;Cho, Soon-Hyung;Yoon, Eui-Park
    • Journal of Korea Foundry Society
    • /
    • v.11 no.6
    • /
    • pp.475-481
    • /
    • 1991
  • In this study the fabrication technology and mechanical properties of AC8A/$Al_2O_3$ Composites by squeeze casting process were investigated to develope for application as the piston materials that require good friction, wear resistance, and thermal stability. AC8A/$Al_2O_3$ composistes without a porosity and the break of preform were fabricated at the melt temperature of $740^{\circ}C$, the preform temperature of $500^{\circ}C$, and mold temperature of $400^{\circ}C$ under the applied pressure of $1200kg/cm^2$ as the results of the observation of microstructures. As the results of this study, the tensile strength of AC8A/$Al_2O_3$ composites was not increased linearly with $Al_2O_3$ volume fraction and so it seemed not to agree with the rule of mixture, which had been used often in metal matrix composite. Also the tensile strength after thermal fatigue test was little different from that before the test. Consequently it was thought that AC8A/$Al_2O_3$ composites fabricated under our experimental conditions had a good thermal stability and subsequently a good interface bonding. Wear rate(i.e., volume loss per unit sliding distance) of AC8A/$Al_2O_3$ composites was decreased with $Al_2O_3$ volume fraction and the sliding speed at both room temperature and $250^{\circ}C$ and so there was a good correlation between wear rate and hardness. Also the wear rate of AC/8A20% $Al_2O_3$ composities was obtained the value of $1.65cm^3/cm$ at sliding speed of 1.14m/sec as compared with about $3.0\;{\times}10^{-8}cm^3/cm$ hyereutectie Al-Si alloy(Al-16%Si-2%Cu-1%Fe-1%Ni), which applied presently for piston materials. The wear behavior of $Al_2O_3$ composites was observed to a type of abrasive wear by the SEM view of wear surface.

  • PDF

Analysis of Conformability for Cadastral Control Network Using GPS Satellite Surveying (GPS에 의한 지적삼각망의 정합성 분석)

  • Kang, Joon-Mook;Yoon, Hee-Cheon;Kim, Hong-Jin
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.2 no.1 s.3
    • /
    • pp.121-129
    • /
    • 1994
  • A number of existing cadastral control stations have been destroyed and shifted by a long lapse of time and careless management. Also, results of them are partly poor owing to dependence on conventional survey method. Because of these, it is very difficult in use of results. Hereupon, correction of cadastral results is necessary in level of government. But it is very consumable to check and adjust results with existing equipments and related techniques only. It is required that this problem can be resolved efficiently. This study analyzed the conformability for cadastral control network to GPS, GPS, which determine precise 3-D coordinates on a short time, to positioning of cadastral stations. We chose DaeJon city for the test area of this study and analyzed the precision of network composed of sixteen cadastral control stations. We made comparision the old result and the new outcome which obtained from coordinate transformation method and horizontal network adjustment method. As a result of this, we detected the blunder of cadastral stations. Furthermore, we suggested effective network type according to precision analysis of GPS observation network. Therefore, there is no doubt that GPS surveying can be applied to checking and adjustment of cadastral control network. Hereafter, it is expected that the practical use of GPS is advanced in a field of cadastration.

  • PDF

Development of a Seismic Measurement System with a reference for the Reduction of Artificial Noise (인공잡음 제거를 위한 기준점 이용 탄성파 측정시스템 개발)

  • Hwang, Hak-Soo;Lee, Tai-Sup;Sung, Nak-Hoon
    • Geophysics and Geophysical Exploration
    • /
    • v.2 no.4
    • /
    • pp.180-183
    • /
    • 1999
  • A proto-type seismic measurement system with a reference was developed to improve S/N (signal-to-noise ratio) of seismic data, especially in noisy urban areas. Two pairs of correlation measurements (the one for microphone and geophone, and another for electromagnetic (EM) loop and geophone) were carried out near Kimpo Airport and at Kimje. The spectrum analyses were also performed to investigate the correlation of two pairs of time series; one for microphone and geophone, and another for EM loop and geophone. The sound waves measured with the microphone and the geophone are highly correlated. However, differences in the reponses are readily identifiable across 200 Hz; in the vicinity of 100 Hz, the spectral energy for geophone is 20 dB higher than that for microphone, and at near 500 Hz, the spectral energy for microphone is 30 dB higher than that for geophone. Overall, the spectral energy appears concentrated on the frequency window below 600 Hz for geophone. It contrasts with the observation of dominant frequency at the range of above 200 Hz for microphone. The wave forms of EM noise (due to an ACDC inverter) measured with EM loop and geophone are consistently and highly correlated each other. The power spectrum of the EM noise for EM loop shows that the spectral energies at odd harmonic frequencies of 60 Hz are higher than those at even harmonic frequencies of 60 Hz. It is compared to the power spectrum for geophone; the spectral energies at odd harmonics are nearly same as those at even harmonic frequencies.

  • PDF

Tissue Engineered Catilage Reconstruction with Alginate Sponge Containing Demineralized Bone Particles (탈미네랄골분이 첨가된 알지네이트 스펀지에서 조직공학적 연골 재건)

  • Kim, Hye Min;Park, Jin Young;Kim, Eun Young;Song, Jeong Eun;Kwon, Soon Yong;Chung, Jin Wha;Khang, Gilson
    • Polymer(Korea)
    • /
    • v.38 no.3
    • /
    • pp.278-285
    • /
    • 2014
  • Demineralized bone particles (DBP) and alginate hybrid sponges were fabricated at 10, 20, 40 and 80% DBP/alginate hybrid ratios for seeding chondrocyte. Cell proliferation was measured via MTT assay. Morphological observation, histology, biological assay and RT-PCR were performed at each time point 1, 2 and 3 weeks. The cell viability was better in 20% DBP/alginate sponges than in other sponges. SEM results showed that more attached and more proliferated cells in the 20% DBP/alginate sponges with the lapse of time. Finally, histochemical assay results showed that the phenotype of chondrocyte was well maintained and both acidic mucopolysaccharide and type II collagen was well formed at 20% sponges. This study suggested that DBP/alginate sponge may serve as a potential cell delivery vehicle and a structural basis for tissue engineered articular cartilage.

Analysis of the Recurrence after Surgical Treatment of the Hemangioma in the Extremities (사지에 발생한 혈관종의 수술적 치료 후 재발에 대한 분석)

  • Kim, Young-Sin;Choi, Hee-Lack;Lee, Jun-Mo;Lee, Hyung-Seok;Kim, Jung-Ryul
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.16 no.2
    • /
    • pp.74-79
    • /
    • 2010
  • Purpose: To analyse the risk factors for recurrence of hemangiomas in extremities after surgical treatment and to compare with those of trunk. Materials and Methods: 120 cases of hemangioma with surgical treatments from June 1998 to September 2009 were analysed. 53 cases with surgical treatment on trunk in the same period were set to be the control group. We analyze several factors: age, location, site, size, histologic types and correlation between recurrence and each risk factor using logistic regression analysis. Results: Recurrence rate was 11.7% in extremities and 9.4% in trunk. There were no correlation between recurrence and age, site, size, histologic type. But, there was stastically significant correlation between recurrence rate and location, especially hand, forearm, feet in extremities and head and neck in trunk. Conclusion: Recurrence after surgical treatment of hemangioma is highly prevalent in anatomical location such as, hand, foot and forearm those are difficult to achieve complete resection because of close to neurovascular structures. Careful observation should be needed owing to incomplete resection can occurs recurrence.

Clinical Analysis of 61 Krukenberg Tumors (크루켄버그 종양 61예에 대한 임상적 분석)

  • Kim Joo Dong;Yook Jeong Hwan;Kim Yong Man;Choi Won Yong;Kim Yong Jin;Lim Jung Taek;Oh Sung Tae;Kim Byung Sik
    • Journal of Gastric Cancer
    • /
    • v.4 no.2
    • /
    • pp.126-130
    • /
    • 2004
  • Purpose: A Krukenberg tumor is an ovarian tumor of a signet-ring cell type. This tumor arises more commonly in young women, and the prognosis is poor. The primary focus of this tumor is often found at gastrointestinal malignancy, especially gastric cancer. We tried to identify the clinical characteristics of this tumor, and in that regard, this report might be helpful. Materials and Methods: We reviewed the 61 patients with Krukenberg tumors, who had been diagnosed at our hospital from 1994 to 2002, and retrospectively analyzed the clinical features. Results: The age distribution ranged from 15 to 59 years, and the mean age was 41 years. The most common symptom was a lower abdominal mass ($46\%$). Fourty-two cases ($77\%$) showed bilateral ovarian involvement, and the size of this tumor was variable, but in 24 cases ($4\%$) the size was $5\∼10$ cm for the largest diameter. Among 54 cases, 40 cases had ascites, and the volume of ascites was variable. The median survival of the 61 patients was 10 months, and Krukenberg tumor developed 19.7 months after the primary operation. The median survival durations of recurrence patterns were 20 months for the Krukenberg tumor alone, and 7 months for the Krukenberg tumor with peritoneal seeding. Conclusion: In young women treated with a gastrectomy, especially one for an advanced tumor, closed observation with abdominal ultrasonography or computed tomography to detect a Krukenberg tumor is recommended. The patient with a Krukenberg tumor alone has a better prognosis than one with a Krukenberg tumor combined peritoneal seeding. We will have to consider more progressive treatment for the patient with a Krukenberg tumor alone.

  • PDF