• 제목/요약/키워드: Obliquity

검색결과 55건 처리시간 0.032초

Do Obliquity and Position of the Oblique Lumbar Interbody Fusion Cage Influence the Degree of Indirect Decompression of Foraminal Stenosis?

  • Mahatthanatrakul, Akaworn;Kotheeranurak, Vit;Lin, Guang-Xun;Hur, Jung-Woo;Chung, Ho-Jung;Lokanath, Yadhu K;Pakdeenit, Boonserm;Kim, Jin-Sung
    • Journal of Korean Neurosurgical Society
    • /
    • 제65권1호
    • /
    • pp.74-83
    • /
    • 2022
  • Objective : Oblique lumbar interbody fusion (OLIF) is a surgical technique that utilizes a large interbody cage to indirectly decompress neural elements. The position of the cage relative to the vertebral body could affect the degree of foraminal decompression. Previous studies determined the position of the cage using plain radiographs, with conflicting results regarding the influence of the position of the cage to the degree of neural foramen decompression. Because of the cage obliquity, computed tomography (CT) has better accuracy than plain radiograph for the measurement of the obliquely inserted cage. The objective of this study is to find the correlation between the position of the OLIF cage with the degree of indirect decompression of foraminal stenosis using CT and magnetic resonance imaging (MRI). Methods : We review imaging of 46 patients who underwent OLIF from L2-L5 for 68 levels. Segmental lordosis (SL) was measured in a plain radiograph. The positions of the cage were measured in CT. Spinal canal cross-sectional area (SCSA), and foraminal crosssectional area (FSCA) measurements using MRI were taken into consideration. Results : Patients' mean age was 69.7 years. SL increases 3.0±5.1 degrees. Significant increases in SCSA (33.3%), FCSA (43.7% on the left and 45.0% on the right foramen) were found (p<0.001). Multiple linear regression analysis shows putting the cage in the more posterior position correlated with more increase of FSCA and decreases SL correction. The position of the cage does not affect the degree of the central spinal canal decompression. Obliquity of the cage does not result in different degrees of foraminal decompression between right and left side neural foramen. Conclusion : Cage position near the posterior part of the vertebral body increases the decompression effect of the neural foramen while putting the cage in the more anterior position correlated with increases SL.

텅스텐 원형 관통자의 관통특성에 관한 연구 (Study on Penetration Characteristics of Tungsten Cylindrical Penetrator)

  • 조종현;이영신;김재훈;배용운
    • 대한기계학회논문집A
    • /
    • 제37권9호
    • /
    • pp.1083-1091
    • /
    • 2013
  • 미사일 설계에서는 매우 효율적이며 치명적인 극히 작은 탄두를 필요로 한다. 탄두에서 각 관통자의 관통성능과 관통자의 총 개수는 탄두 파괴성능에 영향을 미치는 주요 요인이다. 관통자 L/D 의 설계는 탄두의 공간과 중량에 직접적인 관련되어 있다. L 과 D 는 발사체의 길이와 직경이다. AUTODYN-3D code 가 관통자 관통의 영향을 연구하기 위해 사용되었다. 수치해석의 목적은 초기속도, 경사각도, 관통자의 L/D 와 같은 다양한 초기 조건 아래 초고속 충격에 의해 생성되는 관통자의 관통특성을 확인하는 것이다. $L/D{\leq}4$ 에서의 초기 충격속도 증가는 잔류질량과 잔류속도를 감소시킨다.

Effect of Different Types of Foam Rollers on Self-Myofascial Release of the Quadriceps Femoris

  • Heun Jae Ryu;Ji Hun Kim;Han Na Kwon;Ri Been Kim;ji Hwan Byun;Yuean Hei Lee;Jeong Pyo Seo
    • The Journal of Korean Physical Therapy
    • /
    • 제35권4호
    • /
    • pp.89-94
    • /
    • 2023
  • Purpose: This study investigates the impact of self-myofascial release using a foam roller on the quadriceps femoris for pelvic stability. We further compare the effects of a GRID surface Foam Roller (GFR), a Non-Vibration Foam Roller (NVFR), and a Vibration Foam Roller (VFR). Methods: Thirty healthy adults (15 males, 15 females) participated in this study and were randomly assigned to one of three conditions: GFR, NVFR, or VFR. Participants walked at self-selected speeds with an arm sling before and after foam roller stretching. The analyzed gait parameters included pelvic tilt, pelvic obliquity, and pelvic rotation. Results: In the NVFR and VFR groups, there was a Significant differences were obtained in the pelvic tilt between pre-test and post-test values (p<0.05) in the NVFR and VFR groups, but no significant difference was observed in the GFR group (p>0.05). Comparing the amount of change between the three groups exhibited a significant decrease in pelvic tilt in the NVFR and VFR groups compared to the GFR group (p<0.017). No significant differences were found in pelvic obliquity and pelvic rotation (p>0.05) in all groups. Conclusion: While walking, the use of a VFR for self-myofascial release results in pelvic alteration by reducing the anterior pelvic tilt. We propose that a foam roller can be utilized to enhance pelvic stability during gait.

The Influence of Contact Shape on the Slip Regime in Contact-induced Failure

  • Kim, Hyung-Kyu;Kang, Heung-Seok;Song, Kee-Nam
    • KSTLE International Journal
    • /
    • 제2권2호
    • /
    • pp.85-92
    • /
    • 2001
  • The variation of contact traction induced by different contact shapes is studied experimentally and theoretically. Considerations fer the contact shape are rounded, truncated and truncated with rounding punches. A fretting wear experiment is conducted with the contact configuration of the strip on the tube specimens. The strip specimen is pressed to form the end profile of a rounded and truncated with rounding punches shape. Wear on the tube is investigated, which is regarded as the slip region of the contact surface. Taken into consideration is the general solution of the normal traction in the case of the indentation by a punch with its end profile of the combination of parabolas. Then, partial slip solution is obtained numerically, which is compared with the wear on the tube. The radius of the rounding and the obliquity of the edge truncation affect the tractions considerably. It is found that the proper choice of the end profile can restrain the contact-induced failure such aswear.

  • PDF

부분 미끄럼 상태에서의 마찰에너지 방출 및 균열해석 방법 (Method of Friction Energy Dissipation and Crack Analysis under Partial Slip)

  • 김형규
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1999년도 제29회 춘계학술대회
    • /
    • pp.38-46
    • /
    • 1999
  • Numerical methods are procured for evaluating the contact stresses, the dissipation of friction energy density and the fatigue cracking emanated from the contact surface under the partial slip condition. A rounded punch is used for the indenter pressing and slipping on the elastic half plane. Plane strain condition is assumed for the present analysis. Several sample calculations are carried out to investigate the effect of the punch roundness, the shear load path, and the crack obliquity and closure on the failure. It is found that the present methods can be a useful tool for studying the physical failure of the of the contacting materials such as fretting wear and fretting fatigue cracking.

  • PDF

표면처리된 Al 5083-H131 합금의 고속 충격 거동에 관한 연구 (A Study on the fracture behavior of surface treated Al 5083-H131 alloy under the high velocity impact)

  • 손세원;김희재;홍성희;황도연
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.820-824
    • /
    • 1997
  • In order to investigate the effect of surface treatment(Anodizing) and rolling in Al 5083-H131 alloy, ballistic testing was conducted. Ballistic resistance of these materials. was measured by protection ballistic limit(V$_{50}$), a statical velocity with 50% probability for incomplete penetration. Fracture behaviors and ballistic tolerance, described by penetration modes, are observed respectfully, resulting from V$_{50}$ test and Projectile Through Plates(PTP) test at velocities greater than V$_{50}$. PTP tests were conducted with 0$^{\circ}$obliquity at room temperature were also conducted with projectiles that were able to achieve near or complete penetration during PTP tests. Resistance to penetration, and penetration modes of Al 5052-H34 alloy, compared to those of Al 5083-H131 alloy.alloy.

  • PDF

하이브리드 복합재료의 고속충격 저항성에 관한 연구 (A Study on the high velocity impact resistance of hybrid composite materials)

  • 손세원;김희재;김영태
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.273-278
    • /
    • 2003
  • Recently, high-performance hybrid composite materials have been used for various industrial fields because of their superior high strength, high stiffness and lower weight. In this study, manufactured hybrid composite materials are composed of two parts. One is hard-anodized Al5083-O alloy as a face material and the other is high strength aramid fiber ($Twaron^{(R)}$ CT709) laminates as a back-up material. Resistance to penetration is determined by protection ballistic limit($V_{50}$, a static velocity with 50% probability for complete penetration) test method. $V_{50}$ tests with $0^{\circ}$obliquity at room temperature were conducted with 5.56mm ball projectiles that were able to achieve near or complete penetration during high velocity impact tests.

  • PDF

섬유강화 금속 적층 재료의 고속 충격 저항성에 관한 연구 (A Study on the high-velocity impact resistance of fiber reinforced metal laminate materials)

  • 손세원;김영태
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1378-1381
    • /
    • 2003
  • Recently, high-performance composite materials have been used for various industrial fields because of their superior high strength, high stiffness and lower weight. In this study, manufactured fiber reinforced metal laminate materials are composed of two parts. One is hard-anodized A15083-O alloy as a face material and the other is high strength aramid fiber (Twaron CT709) and polyethylene fiber(Dyneema HB25) laminates as a back-up material. Resistance to penetration is determined by protection ballistic limit(V$\sub$50/, a static velocity with 50% probability for complete penetration) test method. V$\sub$50/ tests with 0$^{\circ}$ obliquity at room temperature were conducted with 5.56mm ball projectiles that were able to achieve near or complete penetration during high velocity impact tests.

  • PDF

Anti-Plane Shear Behavior of an Arbitrarily Oriented Crack in Bonded Materials with a Nonhomogeneous Interfacial Zone

  • Chung, Yong-Moon;Kim, Chul;Park, Hyung-Jip
    • Journal of Mechanical Science and Technology
    • /
    • 제17권2호
    • /
    • pp.269-279
    • /
    • 2003
  • The anti-plane shear problem of bonded elastic materials containing a crack at an arbitrary angle to the graded interfacial zone is investigated in this paper The interfacial zone is modeled as a nonhomogeneous interlayer of finite thickness with the continuously varying shear modulus between the two dissimilar, homogeneous half-planes. Formulation of the crack problem is based upon the use of the Fourier integral transform method and the coordinate transformations of basic field variables. The resulting Cauchy-type singular integral equation is solved numerically to provide the values of mode 111 stress intensity factors. A comprehensive parametric study is then presented of the influence of crack obliquity on the stress intensity factors for different crack size and locations and for different material combinations, in conjunction with the material nonhomogeneity within the graded interfacial zone.

외연 유한요소 기법을 사용한 고속충돌 및 관통해석 (High Speed Impact and Penetration Analysis using Explicit Finite Element Method)

  • 백승훈;김승조
    • 한국군사과학기술학회지
    • /
    • 제8권4호
    • /
    • pp.5-13
    • /
    • 2005
  • The impact of a long-rod penetrator into oblique plates with combined obliquity and yaw is investigated. The study was done using a newly developed three dimensional dynamic and impact analysis code, which uses the explicit finite element method. Through the comparison of simulation result with experimental result and other code's result, the adaptability and accuracy of the developed code is evaluated under the complex situation in which yaw angle and oblique angle exist simultaneously. As a result of comparison, it has found that deformed shape, residual length and velocity, rotational velocity of long-rod show good agreement with experimental data. Through this study, the applicability and accuracy of the code as a metallic armour system design tool is verified.