• 제목/요약/키워드: Oblique view

검색결과 86건 처리시간 0.027초

족근 관절 골절에서 사면상 단순 방사선 사진의 유용성 (Usefulness of the Oblique Radiographic View in Ankle Fractures)

  • 조덕연;송상준;윤형구;한수홍;장지훈;윤병호
    • 대한족부족관절학회지
    • /
    • 제9권1호
    • /
    • pp.94-98
    • /
    • 2005
  • Purpose: To compare the radiographic evaluations between two radiographic views (AP and lateral views) and four radiographic views (AP, lateral and both oblique views) in ankle fractures. Materials and Methods: From January 2000 to June 2002, 60 cases of ankle fractures were treated with open reduction and internal fixation and its followed up periods were at least 2 years. All cases were classified into three groups according to the method of preoperative radiographic evaluation. Two radiographic views (AP and lateral views) were taken in group A and four radiographic views (AP, lateral and both oblique views) were taken in group B. 12 Cases were evaluated with three dimensional computed tomography (3D CT). Four radiographic views and 3D CT were taken in group C. All cases were classified according to the Danis-Weber and Lauge-Hansen classification. Displacement of fracture fragment of medial, lateral, posterior malleolus and size of fracture fragment of posterior malleous were measured using picture archiving communication system (PACS). Results: Although kappa value between two or four radiographic views were good or excellent in Danis-Weber classification and Lauge-Hansen classification of ankle fractures, the displacements of medial and lateral malleoli were statistically different. Four radiographic views evalulated the degree of displacement of medial and lateral fragments more accurately compared to two radiographic views. Conclusion: Four radiographic views will be more useful than two radiographic views to decide the method of treatment and operation considering the displacement of fracture fragment.

  • PDF

경사사진(傾斜寫眞)의 해석적(解析的) 위치결정(位置決定)에 있어서 경중율(輕重率) 적용에 관한 연구(硏究) (A Study on Effectiveness of Weight in Analytical Positioning of Oblique Photography)

  • 양인태;권현;유복모
    • 대한토목학회논문집
    • /
    • 제4권2호
    • /
    • pp.143-150
    • /
    • 1984
  • 본(本) 논문(論文)은 경사사진(傾斜寫眞)의 해석적(解析的) 위치결정(位置決定)에 있어서 경중율(輕重率) 적용에 관한 연구(硏究)로서 경사사진(傾斜寫眞)의 정도(精度)를 향상시키고 그 효용성(効用性)을 높이는 데 그 목적(目的)이 있다. 경사사진(傾斜寫眞)은 수직사진(垂直寫眞)에 비(比)하여 피복면적이 넓어 경제적이며 접근하기 어려운 대상물의 좌표해석과 정보(情報)획득에 용이하므로 많은 분야에서 그의 이용을 시도하고 있으나 수직사진에 비하여 해석방법이 복잡하다. 이에 본 연구에서는 경사사진을 수직화(垂直化)하는 데 있어서 해석적(解析的) 편위수정(偏位修正) 이론을 도입하여 고찰하였다. 관측값 해석단계에서는 $30^{\circ}$ 경사사진의 수직화 과정에 본 연구에서 유도한 등각점(等角點)으로부터 상점까지의 y축방향의 거리 ${\gamma}_y=f{\cdot}tan{\frac{\theta}{2}}+y_a$의 역수로 경중율(輕重率)을 적용한 결과 경중율을 고려하지 않은 경사사진에 비하여 53.2%까지 수직사진에 접근시킬 수 있었다.

  • PDF

어깨관절의 접시오목을 나타내는 Grashey법에 대한 연구 (The Study of Grashey Method Viewing the Glenohumeral(shoulder) Joint)

  • 이재섭;김영재
    • 한국방사선학회논문지
    • /
    • 제9권6호
    • /
    • pp.331-335
    • /
    • 2015
  • Glenohumeral joint's를 나타내는 단순방사선 촬영법으로 전후사방향 자세에서 촬영하는 Grashey법이 있다. 이 촬영법 자세는 선 자세에서 검사 측을 들어 올리고 촬영한다. 하지만 촬영 시 환자를 몸통을 들어 올리고 회전하는 정도에 따라 관찰범위가 변화한다. Glenohumeral joint's를 가장 잘 나타내기 위한 몸통 회전 각도를 알아보기 위하여 총 20명(남:13명, 여:7명)을 대상으로 촬영을 실시하였으며, 정확한 영상의 판단을 위하여 정형외과 전문의 2명, 방사선사 2명(경력 15년 이상자)이 관찰 평가하였다. 평가의 척도는 Glenohumeral joint's 분리 정도의 점수를 0점은 '분리 안 됨', 1점은 '불량', 2점은 '보통', 3점은 '양호'로 점수를 부여하였다. 몸통 회전 각도를 $30^{\circ}$ 인 영상은 Humerus head와 Glenoid fossa가 겹쳐서 나타났고, $35^{\circ}$ 인 영상에서는 Humerus head와 Glenoid fossa가 약간 겹쳐서 나타났고, $40^{\circ}$ 인 영상에서는 Humerus head와 Glenoid fossa의 관절강이 가장 겹침이 적게 나타났고, $45^{\circ}$ 인 영상에서도 겹침 정도가 많았다. 각 영상의 평가 점수는 $30^{\circ}$$0.40{\pm}0.499$, $35^{\circ}$$1.34{\pm}0.657$, $40^{\circ}$$1.84{\pm}0.573$, $45^{\circ}$$0.76{\pm}0.649$로 나타났고 통계적으로 유의한 차이를 나타냈다.(p < .05). 선 자세에서 Glenohumeral joint's를 나타내기 위한 자세에서 환자 몸통을 $40^{\circ}$ 검사 반대 측을 들어 올리고 촬영하였을 경우 우리는 가장 양호한 접시오목(Glenoid fossa)를 나타낼 수 있었다.

다각사진촬영시스템 프로토타입 개발 (Development of a Multi-View Camera System Prototype)

  • 박선동;서상일;윤동진;신진수;이창노
    • 한국측량학회지
    • /
    • 제27권2호
    • /
    • pp.261-271
    • /
    • 2009
  • 최근 도시의 3차원 공간정보에 대한 필요성이 증가함에 따라 연직사진과 경사사진을 동시에 촬영하는 항공용 다각카메라에 대한 관심이 높아지고 있다. 기존의 지형공간정보는 주로 연직사진에 의존하지만 다각 카메라는 연직사진 뿐 아니라 사방에서 촬영된 경사사진도 함께 이용하므로 사용자가 대상물을 쉽게 판독할 수 있게 한다. 본 연구에서는 카메라시스템, GPS/INS, 촬영안내시스템, 제어시스템으로 구성된 다각사진촬영시스템 프로토타입을 개발하고, 실제 항공촬영에 통해 장비개발 시 고려해야 할 카메라 설치 각도, 동시촬영, 촬영시간지연, 저장 등에 대해 실험하였다.

어깨뼈 후전사방향촬영에서 Tube 각도와 환자의 회전각도 관한 연구 (A Study of Tube Angle and Patient's Rotation Angle in Scapular Y View)

  • 안병주;이준행
    • 한국방사선학회논문지
    • /
    • 제7권4호
    • /
    • pp.271-275
    • /
    • 2013
  • 어깨뼈 검사는 일상생활, 스포츠 활동 시에 어깨관절의 후측부나, 후외측부에 강한 외력이 가해서 발생하는 직접외상에 의한 경우와 상완부에 주로 외전, 신전, 외회전력이 가해져 어깨관절 탈구 등 병변의 유무를 관찰하는데 유용하게 사용되고 있다. 본 연구의 목적은 어깨관절 후전사방향촬영(shoulder PA oblique projection, scapula Y-view)의 촬영각도에 따른 영상의 왜곡을 방지하고 방사선학적 진단에 가장 유용한 촬영 각도를 알아보고자 하였다. 어깨뼈체부와 봉우리(acromion) 및 부리돌기(coracoid process)는 Y자를 이루게 되는데 $10^{\circ}$에서는 어깨뼈와 봉우리사이의 각도가 협착되어 나타나고, $20^{\circ}{\sim}25^{\circ}$에서는 Y자에 위팔뼈머리가 겹쳐 보이며, 어깨관절과의 위치도 적절해 보였다. $35^{\circ}$에서는 위팔뼈머리가 Y자에 겹쳐 보이지만, 위팔뼈머리와 어깨관절이 왜곡되어 보였다. 환자체위는 $45^{\circ}$ 거상시킬 때 가장 적합한 측면상을 관찰되며, 봉우리(acromion) 및 부리돌기(coracoid process)도 Y 자를 이루었다.

Supine 자세에서 Shoulder oblique촬영시 Tube angle 변화에 따른 Shoulder joint에 대한 고찰 (Consideration of Shoulder Joint's Image with the Changed Tube Angle of the Shoulder Oblique Projection in Supine Position)

  • 서재현;최남길
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제31권2호
    • /
    • pp.109-114
    • /
    • 2008
  • 어깨의 병변을 관찰하는 단순 방사선촬영법들 중 견관절을 보기 위한 대표적인 검사법으로 Shoulder oblique법(Grashey법)이 있다. 이 검사는 견관절의 정면상을 볼 수 있는 검사로 누운 자세에서 검사할 때는 몸의 한쪽 면을 거상시키는 자세를 취하여 검사를 시행한다. 하지만 몸이 불편하거나 수술직후의 환자들의 경우에는 이러한 자세를 취하는 것이 힘들기 때문에 견관절이 잘 묘출되는 영상을 얻기가 어렵다. 이러한 어려움을 개선하면서 견관절이 잘 나타나는 영상을 얻을 수 있는 방법을 모색해 보고자 누운 자세에서 몸의 한쪽면을 거상시키는 자세를 취하는 대신에 누운 자세를 취한상태에서 X-선관의 각도를 Medio-Lateral(몸의 중심에서 바깥쪽으로) 방향으로 변화시켜 영상을 획득하였다. 총 15명(남: 9, 여: 6)을 대상으로 검사를 시행하였으며 획득한 영상은 Picture archiving and communication system(PACS) 모니터에서 전문가 4명(정형외과 전문의 2명, 방사선과 전문의 2명)이 각각 독립적으로 평가하여 점수를 부여하였다. 그 결과, X-선관의 각도를 Medio-Lateral로 변화시킨 정도가 $25^{\circ}$인 영상에서는 상완골두와 견갑골이 겹쳐보였으며, $30^{\circ}$$35^{\circ}$인 영상에서는 상완골두와 견갑골이 분리되어 보였고, $40^{\circ}$인 영상에서는 상완골두와 견갑골이 분리되어 보였으나 영상이 많이 왜곡되어 나타났다. 영상의 평가점수는 각각 $25^{\circ}1.20{\pm}0.414$ (평균$\pm$표준편차), $30^{\circ}2.47{\pm}0.516$, $35^{\circ}2.87{\pm}0.352$, $40^{\circ}2.27{\pm}0.458$로 나타났고 통계적으로 유의한 차이를 나타냈다(p < 0.05). 왜곡의 정도는 $30^{\circ}$에서 적게 나타났고 $40^{\circ}$에서 심하게 나타났다. 누운 자세를 취한상태에서 X선관의 각도를 Medio-Lateral 방향으로 $30{\sim}35^{\circ}$ 주는 경우 가장 좋은 견관절 영상을 얻을 수 있었으나 이 방법이 Shoulder Oblique법보다 상완골두의 왜곡을 더 발생시키는 것도 확인할 수 있었다. 하지만 이 방법은 몸이 불편한 환자들의 견관절을 검사하는데 매우 유용하게 사용할 수 있고 특히 응급환자의 경우 환자의 체위변화 없이 사용가능하다는 장점이 있다. 뿐만 아니라 체위변화가 없는 이 촬영법은 환자의 추적 검사 시에도 최적의 동일 X선관의 각도를 적용하기 때문에 이전검사와 거의 같은 영상을 얻을 수 있어서 영상의 비교에도 유용할 것으로 사료된다.

  • PDF

초고층건물의 사각조망에서 촬영된 지붕표면 열화상의 신뢰도 평가 (Evaluating Reliability of Rooftop Thermal Infrared Image Acquired at Oblique Vantage Point of Super High-rise Building)

  • 류택형;엄정섭
    • 한국태양에너지학회 논문집
    • /
    • 제33권5호
    • /
    • pp.51-59
    • /
    • 2013
  • It is usual to evaluate the performance of the cool roof by measuring in-site rooftop temperature using thermal infra-red camera. The principal advantage of rooftop thermal infrared image acquired in oblique vantage point of super high-rise building as a remote sensor is to provide, in a cost-effective manner, area-wide information required for a scattered rooftop target with different colors, utilizing wide view angle and multi-temporal data coverage. This research idea was formulated by incorporating the concept of traditional remote sensing into rooftop temperature monitoring. Correlations between infrared image of super high-rise building and in-situ data were investigated to compare rooftop surface temperature for a total of four different rooftop locations. The results of the correlations analyses indicate that the rooftop surface temperature by the infrared images of super high-rise building alone could be explained yielding $R^2$ values of 0.951. The visible permanent record of the oblique thermal infra-red image was quite useful in better understanding the nature and extent of rooftop color that occurs in sampling points. This thermal infrared image acquired in oblique vantage point of super high-rise made it possible to identify area wide patterns of rooftop temperature change subject to many different colors, which cannot be acquired by traditional in-site field sampling. The infrared image of super high-rise building breaks down the usual concept of field sampling established as a conventional cool roof performance evaluation technique.

허리뼈 사방향 X-선 검사에서 3D 프린팅으로 제작된 보조기구의 임상적 유용성 평가 (Evaluation of the Clinical Usefulness of an Assistive Device Fabricated by 3D Printing in an Oblique X-ray Examination of the Lumbar Vertebrae)

  • 김형균
    • 한국방사선학회논문지
    • /
    • 제16권5호
    • /
    • pp.505-512
    • /
    • 2022
  • 인체 질병진단을 위해 3D 프린팅으로 제작된 보조기구를 엑스선 검사에 적용하였다. 사용 평가된 결과를 바탕으로 통계 분석하여 임상적 유용성을 평가하고 도입의사를 회귀분석 하였다. 실험은 90명의 방사선사들이 허리뼈 사방향 엑스선 검사에서 보조기구 사용에 동의한 환자를 대상으로 엑스선 검사 진행 후 기존 사용 보조기구와 요인분석 등으로 통계 분석하였다. 3D 프린팅으로 제작된 보조기구 도입의사에 대한 변수를 종속변수로 요인분석으로 계산된 3D 프린팅 보조기구 및 기존 사용 보조기구를 독립변수로 설정한 다중회귀분석 비표준화 계수 값이 0.893(p<0.001), 0.269(p<0.001)으로 나타나 모두 통계적으로 유의미한 결과를 나타내었다. 결과적으로 본 연구로 제작된 3D 프린팅 보조기구가 허리뼈 사방향 엑스선 검사에서 기존 사용하는 보조기구보다 임상적 유용성이 더 높음을 확인 할 수 있었다.

Alternative Method of Retrocrural Approach during Celiac Plexus Block Using a Bent Tip Needle

  • An, Ji Won;Choi, Eun Kyeong;Park, Chol Hee;Choi, Jong Bum;Ko, Dong-Kyun;Lee, Youn-Woo
    • The Korean Journal of Pain
    • /
    • 제28권2호
    • /
    • pp.109-115
    • /
    • 2015
  • Background: This study sought to determine safe ranges of oblique angle, skin entry point and needle length by reviewing computed tomography (CT) scans and to evaluate the usefulness of a bent tip needle during celiac plexus block (CPB). Methods: CT scans of 60 CPB patients were reviewed. Image of the uppermost margin of L2 vertebral body was used to measure the minimal and maximal oblique angles and the distances from the midline to skin puncture point. The imaginary needle trajectory distance was calculated by three-dimensional measurement. When the procedure was performed by using a $10^{\circ}$ bent tip needle under a $20^{\circ}$ oblique X-ray fluoroscopic view, the distance (GF/G'F) from the midline to the actual puncture site was measured. Results: The imaginary safe oblique angle range was $26.4-34.2^{\circ}$ and $27.7-36.0^{\circ}$ on the right and left, respectively. The distance from the midline to skin puncture point was 6.1-7.6 cm on the right and 6.3-7.6 cm on the left. The needle trajectory distance at minimal angle was 9.6-11.6 cm on the right and 9.5-11.5 cm on the left. The distance of GF/G'F was 5.1-6.5 cm and 5.0-6.4 cm on the right and left, respectively. All imaginary parameters were correlated with BMI except for GF/G'F. All complications were mild and transient. Conclusions: We identified safe values of angles and distances using a straight needle. Furthermore, using a bent tip needle under a $20^{\circ}$ oblique fluoroscopic view, we could safely perform CPB with smaller parameter values.

경추 추간공 관찰을 위한 촬영법의 고찰 (The Comparison of $45^{\circ}$ and $55^{\circ}$ Anteroposterior Oblique View for Observating the Intervertebral Foramen)

  • 전주섭;은성종;김혜란;안승현;최남길;김영근
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제28권2호
    • /
    • pp.91-95
    • /
    • 2005
  • I. 목 적 : 경추의 퇴행성 질환이나 분리증을 진단하는데 필수적인 전 후 사방향 촬영은 $45^{\circ}$사방향 (하 상방향 tube angle $15^{\circ}$)으로 촬영하여 경추 추간공과 주변 구조물을 살피는 것으로 알려져 있으나 아직까지 우리나라 성인에 대한 연구결과는 거의 없는 실정이다. 본 연구는 우리나라 성인에 적합한 전 후 사방향 촬영 각도를 알아보는데 목적이 있다. II. 대상 및 실험방법 : 1. 연구대상인 성인의 경추 신경공과 정중 시상면이 이루는 평균 각을 알아보기 위해 C-spine MRI를 촬영한 환자 200명(남 100명, 평균 40.3세, 여자 100명 47.6세)을 대상으로 축방향 T2 강조영상에서 C2-C3부터 C7-T1까지의 평균 각을 구하였다. 2. 경추에 이상이 없는 남자 10명(평균 36.2세)을 대상으로 전 후 사방향 촬영시 경추 신경공과 정중 시상면이 이루는 각도에서 실제로 추간공이 가장 크게 관찰되는지를 알아보기 위하여 나선식CT(QXi, GE medical) 촬영을시행하여, 축방향 영상에서 추간공이 이루는 각과 3D Raysum기법에서의 추간공의 최대횡경을 이루는 각도를 비교하였다. 또한 경추 전후 사방향 $45^{\circ}$, $50^{\circ}$, $55^{\circ}$(하 상방향 tube angle $15^{\circ}$)로 촬영한 일반촬영 영상을 PACS로 전송하여 최대횡경을 측정하고, 그 차이를 비교하였다. III. 결 과 : 연구대상인 성인추간공의 평균 각도를 MR영상에서 측정한 결과 C2-C3, C3-C4, C4-C5, C5-C6, C6-C7, C7-T1에서의 각은 $47.4^{\circ}{\pm}3.3$, $50.5^{\circ}{\pm}2.3$, $52.7^{\circ}{\pm}4.2$, $53.2^{\circ}{\pm}1.9$, $53.2^{\circ}{\pm}2.3$, $55.2^{\circ}{\pm}2.3$로 나타나 하부 경추로 갈수록 신경공과 정중 시상면이 이루는 각이 커짐을 알 수 있었다. 10명을 대상으로 CT촬영하여 Raysum 영상에서 추간공의 최대 횡경을 보이는 각도와 2D 축방향 영상에서 측정한 추간 공의 각도의 비교에서는 유의한 차이가 없었다(P>0.01). 전 후 사방향 $45^{\circ}$, $50^{\circ}$, 그리고 $55^{\circ}$로 촬영한 일반촬영에서의추간공의최대횡경을측정한결과 C2-C3, C3-C4, C4-C5까지는 각도가 $5^{\circ}$씩 커질수록 횡경이 감소($0.11\;mm{\sim}0.21\;mm$)한 반면 C5-C6, C6-C7, C7-T1에서는 횡경이 증가($0.32\;mm{\sim}0.91\;mm$)함을 알 수 있었으며, 그 차이를 분산분석(ANOVA)을 통해 비교한 결과 하부경추로 갈수록 유의한 차이가 있는 것으로 나타났다(P<0.001). IV. 결 론 : 우리나라 성인에 있어서 추간공을 관찰하기 위한 전 후 사방향촬영각도는 상부 경추의 경우 전 후사방향 $50^{\circ}$에서, 하부 경추의 경우 $55^{\circ}$에서 추간공을 가장 크게 관찰할 수 있었다. 따라서 향후 경추의 퇴행성 질환을 진단하는데 본 연구의 촬영법이 유용할 것으로 사료된다.

  • PDF