Evaluating Reliability of Rooftop Thermal Infrared Image Acquired at Oblique Vantage Point of Super High-rise Building (초고층건물의 사각조망에서 촬영된 지붕표면 열화상의 신뢰도 평가)

  • Ryu, Taek-Hyoung;Um, Jung-Sup
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.5
    • /
    • pp.51-59
    • /
    • 2013
  • It is usual to evaluate the performance of the cool roof by measuring in-site rooftop temperature using thermal infra-red camera. The principal advantage of rooftop thermal infrared image acquired in oblique vantage point of super high-rise building as a remote sensor is to provide, in a cost-effective manner, area-wide information required for a scattered rooftop target with different colors, utilizing wide view angle and multi-temporal data coverage. This research idea was formulated by incorporating the concept of traditional remote sensing into rooftop temperature monitoring. Correlations between infrared image of super high-rise building and in-situ data were investigated to compare rooftop surface temperature for a total of four different rooftop locations. The results of the correlations analyses indicate that the rooftop surface temperature by the infrared images of super high-rise building alone could be explained yielding $R^2$ values of 0.951. The visible permanent record of the oblique thermal infra-red image was quite useful in better understanding the nature and extent of rooftop color that occurs in sampling points. This thermal infrared image acquired in oblique vantage point of super high-rise made it possible to identify area wide patterns of rooftop temperature change subject to many different colors, which cannot be acquired by traditional in-site field sampling. The infrared image of super high-rise building breaks down the usual concept of field sampling established as a conventional cool roof performance evaluation technique.

Geometric Assessment and Correction of SPOT5 Imagery

  • Kwoh, Leong Keong;Xiong,, Zhen;Shi, Fusheng
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.286-288
    • /
    • 2003
  • In this paper, we present our implementation of the direct camera model (image to ground) for SPOT5 and use it to assess the geometric accuracy of SPOT5 imagery. Our assessment confirms the location accuracy of SPOT5 imagery (without use of GCPs) is less than 50m. We further introduce a few attitude parameters to refine the camera model with GCPs. The model is applied to two SPOT5 supermode images, one near vertical, incidence angle of 3 degrees, and one far oblique, incidence angle of 27 degrees. The results show that accuracy (rms of check points) of about one pixel (2.5m) can be achieved with about 4 GCPs by using only 3 parameters to correct the yaw, pitch and roll of the satellite.

  • PDF

Effects of Stabilization Exercise on the Structural Characteristics of Trunk Muscles between Stable and Unstable Surfaces

  • Park, Jae-Cheol;Yu, Jae-Young;Hwang, Tae-Yeon;Kim, Chan-Kyu;Jeong, Jin-Gyu
    • The Journal of Korean Physical Therapy
    • /
    • v.28 no.5
    • /
    • pp.297-302
    • /
    • 2016
  • Purpose: This study was conducted to evaluate the effects of bridge exercise on the structural characteristics of trunk muscles in patients with lumbar pain by applying the exercise on either a stable or an unstable surface. Methods: Thirty subjects participated in the experiment and were randomly divided into an unstable bridge exercise group (UBEG) and a stable bridge exercise group (SBEG). The exercise program for each group was conducted three times a week over a six-week period. The structural characteristics of trunk muscles were measured by obtaining images using an ultrasound imaging device. Results: The thicknesses of the external oblique (EO), internal oblique (IO), and transverse abdominis (TrA) and the fiber angle of the erector spinae (ES) in the UBEG and the SBEG showed statistically significant increases in all items measured after the experiment. A comparison of groups conducted after the experiment to determine the effects of the exercise on each group showed no significant differences between groups for any of the measured items. Conclusion: A comprehensive review of the study results showed statistically significant increases in the thicknesses of the EO, IO, and TrA and the fiber angle of ES in both the UBEG and the SBEG. While the comparison of the groups with respect to the effects of the exercise revealed no significant differences, there were relatively larger effects in the UBEG than in the SBEG.

Performance Comparison of Pressure Sensitive Paint and Pressure Field Measurement of Oblique Impinging Jet (Pressure Sensitive Paint의 성능비교 및 경사충돌분류의 압력장 측정)

  • Lee, Sang-Ik;Lee, Sang-Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.7
    • /
    • pp.1031-1038
    • /
    • 2002
  • The pressure sensitive paint (PSP) has recently received a considerable attention in the fields of aerodynamics and fluid mechanics as a new revolutionary optical technique to measure pressure fields on a body surface. In this study, the feasibility and effectiveness of the PSP pressure field measurement technique have been investigated experimentally. Seven different PSP formulations including two porphyrins(PtOEP and PtTFPP) and four polymers(Polystyrene, cellulous acetate butyrate, GP-197 and Silicon-708) were tested to check the performance and characteristics of each combination. The static calibration of each PSP formulation was carried out in a constant-pressure chamber. The PSP technique was applied to an oblique impinging jet flow to measure variation of pressure field on the impinging plate at on oblique jet angle of ${\theta}=60^{\circ}$. Pressure field images were captured by an 12bit intensified CCD(ICCD, $1K{\times}1K$)camera. As a result, the dynamic response of PSP depends on the oxygen permeability of polymer and the photochemical interaction between luminophore and polymer as well as the reaction of luminophore itself. The reaction of luminophore was changed by employing different polymers. In conclusion, Among 7 PSP formulation tested, the combination of PtTFPP and cellulous acetate butyrate show the best performance. In addition, the detail pressure field of an oblique high-speed impinging jet was measured effectively using the PSP technique.

Broden photographing method for Calcaneus Subtentaculum tali observation of Ankle plaster patient (발목부상을 당한 석고환자의 발꿈치뼈·목말받침돌기 관찰을 위한 Broden 촬영법 연구)

  • An, Byeongju
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.2
    • /
    • pp.107-112
    • /
    • 2013
  • There is an Ankle Oblique(Broden' low) as an examination for the patient whose ankle was encased in orthopedic plaster. Some types of Ankle Joint coalition - Calcaneonavicular coalition, Talocalcaneal coalition and Naviculocuneiform coalition. This study is focused on the relation between Ankle Joints and the structural change of soft tissues, also finding the most proper angle to obtain good images of Ankle Joint from the patient who wore a plaster on his ankle, when we x-ray with Harris-Beath View($30^{\circ}{\sim}55^{\circ}$) - for observing Subtalar joint, Calcaneus Fracture, Subtentaculum, Tali Fracture and Talocalcaneal coalition. We intend to get the angle which makes us achieve the good image that shows Calcaneus Fracture, Subtentaculum, and Tali Fracture by changing internal angles of the patient's ankle. We evaluated the images obtained from 51 patients with PACS monitor. The result of the evaluation, subtalar joint was not seperated but opened, and Subtentaculum Tali Fracture was seen overlaid. at the angle 30, we could observe Calcaneus Fracture, Subtentaculum Tali Frature and the front part of behind side of subtalar joint well. And Calcaneo Navicularcoalition, Talocal Canealcoalition, Naviculo Cuneiform coalition condition were clearly seen at that angle. At the angle 35, we could achieve the clear images of subtalar comminuted fracture, talus, the behind joint of heel bone and get the high definition image on the degree of talocalcaneal joint separation. In addition to, We could obtain the good wide image of Sinus Tarsi. At the area of 45, We can distinguish the soft tissues from gyps separation. The outer-talus and density of the bone were definitely seen and Calcaneus is more separated than that of at the angle of 35, but this image is distorted. Calcaneus, Subtentaculum Tali show $1.20{\pm}0.414$ at the angle 25, $2.47{\pm}0.516$ at the angle 30, $2.27{\pm}0.458$ at the angle 45. This difference is statistically meaningful. (p<0.05). Including the degree of distortion, The distortion appears less at the area of $30^{\circ}$ but at the area of 40, there is heavy distortion. So, We could get the best image for making a diagnosis. At the $30{\sim}35^{\circ}$ degree for X-raying ankle. and at the $30{\sim}40^{\circ}$ for Calcaneus Fracture, Subtentaculum Tali Fracture.

Relationship between needle depth for lumbar transforaminal epidural injection and patients' height and weight using magnetic resonance imaging

  • John, Hyunji;Sohn, Kyomin;Kim, Jae Hun
    • The Korean Journal of Pain
    • /
    • v.35 no.3
    • /
    • pp.345-352
    • /
    • 2022
  • Background: Optimal needle depth in transforaminal epidural injection (TFEI) is determined by body measurements and is influenced by the needle entry angle. Physician can choose the appropriate needle length and perform the procedure more effectively if depth is predicted in advance. Methods: This retrospective study included patients with lumbosacral pain from a single university hospital. The skin depth from the target point was measured using magnetic resonance imaging transverse images. The depth was measured bilaterally for L4 and L5 TFEIs at 15°, 20°, and 25° oblique angles from the spinous process. Results: A total of 4,632 measurements of 386 patients were included. The lengths of the left and right TFEI at the same level and oblique angle were assessed, and no statistical differences were identified. Therefore, linear regression analysis was performed for bilateral L4 and L5 TFEIs. The R-squared values of height and weight combined were higher than the height, weight, and body mass index (BMI). The following equation was established: Depth (mm) = a - b (height, cm) + c (weight, kg). Based on the equation, maximal BMI capable with a 23G, 3.5-inch, Quincke-type point spinal needle was presented for three different angles (15°, 20°, and 25°) at lumbar levels L4 and L5. Conclusions: The maximal BMI that derived from the formulated equation is listed on the table, which can help in preparations for morbid obesity. If a patient has bigger BMI than the one in the table, the clinician should prepare longer needle than the usual spinal needle.

Accuracy Assessment of Aerial Triangulation of Network RTK UAV (네트워크 RTK 무인기의 항공삼각측량 정확도 평가)

  • Han, Soohee;Hong, Chang-Ki
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.38 no.6
    • /
    • pp.663-670
    • /
    • 2020
  • In the present study, we assessed the accuracy of aerial triangulation using a UAV (Unmanned Aerial Vehicle) capable of network RTK (Real-Time Kinematic) survey in a disaster situation that may occur in a semi-urban area mixed with buildings. For a reliable survey of check points, they were installed on the roofs of buildings, and static GNSS (Global Navigation Satellite System) survey was conducted for more than four hours. For objective accuracy assessment, coded aerial targets were installed on the check points to be automatically recognized by software. At the instance of image acquisition, the 3D coordinates of the UAV camera were measured using VRS (Virtual Reference Station) method, as a kind of network RTK survey, and the 3-axial angles were achieved using IMU (Inertial Measurement Unit) and gimbal rotation measurement. As a result of estimation and update of the interior and exterior orientation parameters using Agisoft Metashape, the 3D RMSE (Root Mean Square Error) of aerial triangulation ranged from 0.153 m to 0.102 m according to the combination of the image overlap and the angle of the image acquisition. To get higher aerial triangulation accuracy, it was proved to be effective to incorporate oblique images, though it is common to increase the overlap of vertical images. Therefore, to conduct a UAV mapping in an urgent disaster site, it is necessary to acquire oblique images together rather than improving image overlap.

Transitional Behavior of a Supersonic Flow in a Two-dimensional Diffuser

  • Kim, Sehoon;Kim, Hyungjun;Sejin Kwon
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.12
    • /
    • pp.1816-1821
    • /
    • 2001
  • Two-dimensional blow-down type supersonic wind tunnel was designed and built to investigate the transient behavior of the startup of a supersonic flow from rest. The contour of the divergent part of the nozzle was determined by the MOC calculation. The converging part of the nozzle, upstream of fille throat was contoured to make the flow uniform at the throat. The flow characteristics of the steady supersonic condition were visualized using the high-speed schlieren photography. The Mach number was evaluated from the oblique shock wave angle on a sharp wedge with halt angle of 5 degree. The measured Mach number was 2.4 and was slightly less than the value predicted by the design calculation. The initial transient behavior of the nozzle was recorded by a high-speed digital video camera with schlieren technique. The measured transition time from standstill to a steady supersonic flow was estimated by analyzing the serial images. Typical transition time was approximately 0.1sec.

  • PDF

Does matching relation exist between the length and the tilting angle of terminal implants in the all-on-four protocol? stress distributions by 3D finite element analysis

  • Li, Xiaomei;Cao, Zhizhong;Qiu, Xiaoqian;Tang, Zhen;Gong, Lulu;Wang, Dalin
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.3
    • /
    • pp.240-248
    • /
    • 2015
  • PURPOSE. To explore whether there is matching relation between the length and the tilting angle of terminal implants in the All-on-Four protocol by studying the effects of different implant configurations on stress distributions of implant, bone, and framework. MATERIALS AND METHODS. Four implants were employed to support a full-arch fixed prosthesis and five three-dimensional finite element models were established with CT images, based on the length (S and L) and distal tilt angle ($0^{\circ}$, $30^{\circ}$ and $45^{\circ}$) of terminal implants for an edentulous mandible, which named: Tilt0-S, Tilt30-S, Tilt30-L, Tilt45-S and Tilt45-L. An oblique 240 N was loaded at second molar. The von Mises Stresses were analyzed. The implants were consecutively named #1 to #4 from the loading point. RESULTS. 1) Tilt0-S had the greatest stress on the implants, with the other groups exhibiting variable reductions; the four implants of Tilt45-L demonstrated the greatest reduction in stress. 2) Tilt0-S had the greatest stress at bone around #1 implant neck, and Tilt45-L exhibited the least stress, which was a 36.3% reduction compared to Tilt0-S. 3) The greatest stress in the framework was found on the cantilevers distal to #1 implant. Tilt45-S exhibited the least stress. CONCLUSION. Matching different length and tilting angle of the terminal implants led to variable stress reductions on implants, bone and the superstructure. By optimizing implant configuration, the reduction of stress on implants and surrounding bone could be maximized. Under the present condition, Tilt45-L was the preferred configuration. Further clinical testings are required.

Consideration of Shoulder Joint's Image with the Changed Tube Angle of the Shoulder Oblique Projection in Supine Position (Supine 자세에서 Shoulder oblique촬영시 Tube angle 변화에 따른 Shoulder joint에 대한 고찰)

  • Seo, Jae-Hyun;Choi, Nam-Gil
    • Journal of radiological science and technology
    • /
    • v.31 no.2
    • /
    • pp.109-114
    • /
    • 2008
  • There is a standard shoulder oblique method (Grashey method) available to view the shoulder joint. This method projects AP view of the shoulder joint so that the Humerus head's subuxation or joint degeneration can be easily visualized. However, in this view, the patients, with supine or sitting or erect position, have to keep their body obliquely. Whereas, the patients who are not well or operated, usually feel very uncomfortable to keep their body in this position and hence, we need other persons' help and much efforts will be needed to get the good quality shoulder joint view. Therefore, we thought of examining a method which shows the joint well by angling the tube to Medio-Lateral direction and without keeping the patients' one side upward in supine position. For this study, total 15 subjects with no history of neurological or psychiatric illness, were recruited for examinations. They consisted of 9 males and 6 females. Statistic group analysis was performed with ANOVA test. Scores of the evaluation of the experts were $1.10{\pm}0.54$ at $25^{\circ}$, $2.50{\pm}0.50$ at 30^{\circ}$, $2.85{\pm}0.36$ at $35^{\circ}$ and $2.33{\pm}0.47$ at $40^{\circ}$, respectively, and they were significant(p<0.05, Table 1). Joint space of the Humerus head and Scapula were well distinguished at $35^{\circ}$, $30^{\circ}$ and $40^{\circ}$ with the almost same score. However, the degree of distortion at $40^{\circ}$ was more severe than that at $30^{\circ}$. Ultimately, $30-35^{\circ}$ views were shown to yield good quality shoulder oblique images. In conclusion, this method may be very useful for the patients who are uncomfortable and for the emergency patients. In order to get similar or comparable view, the same X-tube angle is recommended to be used before and after the operation. Therefore, we hope that this new angled method seems to be efficient.