• 제목/요약/키워드: Oblique

검색결과 1,718건 처리시간 0.025초

Effects of Shoulder Abduction in Opposite Directions on EMG Activity in the Abdominal Muscles during Single Leg Raising in the Supine Position on the Foam Roller in Healthy Subjects

  • Yun, Sung-Joon;Kim, Moon-Hwan
    • The Journal of Korean Physical Therapy
    • /
    • 제27권4호
    • /
    • pp.270-274
    • /
    • 2015
  • Purpose: The purpose of this study was to examine the electromyographic (EMG) activity of the abdominal muscles and to compare the activity ratios of the bilateral rectus abdominis (RA) to oblique abdominal muscles during shoulder abduction in opposite directions with single leg raising (SLR) performed in the supine position on a foam roller. Methods: Fifteen healthy subjects were recruited to the study. Each subject lay on the foam roller and performed left single leg raising with right or left shoulder $90^{\circ}$ abduction (Abd); performed in a random order. Surface EMG recordings of selected abdominal muscles (i.e., the RA, external oblique abdominis [EO], internal oblique abdominis [IO], and transverse abdominis [TrA]) were normalized to maximum voluntary isometric contraction. EO/RA and IO and TrA/RA ratios were determined with surface EMG. Data were analyzed by Independent t-test. The statistical significance level was p<0.05. Results: The results were as follows: (1) the right RA, left EO, and right IO and TrA muscle activities increased significantly at the left SLR with left Abd compared to the left SLR with right Abd (p<0.05); and (2) the ratio of right EO/RA activity increased significantly at the left SLR with right Abd compared to left Abd (p<0.05). Conclusion: These findings suggest that left SLR with left Abd on a foam roller is an appropriate exercise for activation of specific oblique abdominal muscles.

밸브 없는 양방향 피에조 마이크로펌프의 유동해석 (A Numerical Study on Flow Analysis of a Valveless Bidirectional Piezoelectric Micropump)

  • 이상혁;허인영;허남건
    • 한국유체기계학회 논문집
    • /
    • 제11권3호
    • /
    • pp.14-21
    • /
    • 2008
  • A numerical simulation on the flow field of a valveless bidirectional piezoelectric micropump has been performed. In this type of micropump, the oscillation of the piezoelectric diaphragm generates the blowing and suction flow through the oblique channel from the pumping chamber. The angle between the oblique and main channel causes the variation of flow distribution through upstream and downstream channels in suction and blowing modes. In the suction flow mode, the working fluid flows from both the upstream and downstream of the main channel to the pumping chamber through the oblique channel. However, in the blowing flow mode, the fluid pushed out of the pumping chamber flows more toward the downstream of the main channel due to the inertia of the fluid. In the present study, the effects of geometries such as the angle of oblique channel and the shape of main channel on the flow rate of the up/downstream were investigated. The flow rate obtained from the pump and the energy required to the pump were also analyzed for various displacements and frequencies of the oscillation of the diaphragm.

경사단을 갖는 Steel 및 복합재료 원통쉘의 자유진동 특성에 관한 연구 (A Study on Free Vibration of Steel and Composite Cylindrical Shells with an Oblique Angle)

  • 이장원;최영진;이영신
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.928-933
    • /
    • 2004
  • The vibration characteristic is a primary design factor. The cylindrical shells are used as a primary components of complex structure. also, The cylindrical shells have oblique angle. In this study, The vibrational characteristics of steel and plain wave GFRP cylindrical shell with an oblique end are given by experimental and finite element method. To be find characteristic of the oblique end, the mass of the cylindrical shell is maintained. Natural frequency and mode shapes of isotropic and plain weave composite shells are obtained by modal test. The results are compared with those of the finite element method. The simply supported boundary conditions with bolts along the circumferential direction of the GFRP shell are well achieved. Also, The clamped boundary conditions is applied to the steel specimen. Those are shown to agree well with the analytical results and finite element analysis results.

  • PDF

Influence of Slashpipe Exercise on Symmetrical Contraction of Trunk Muscle in Normal Adults

  • Choi, Young In;Kim, Jung Sun;Kim, Shin Young
    • The Journal of Korean Physical Therapy
    • /
    • 제31권5호
    • /
    • pp.298-303
    • /
    • 2019
  • Purpose: This study examined the effects of slashpipe exercise on reducing the thickness of the left and right external oblique, internal oblique, transverse abdominis, erector spinae, and multifidus muscles. Methods: A total of 29 healthy adult men and women were included in the study. They performed trunk flexion in the supine position and trunk extension in the prone position with a slashpipe and weight bar. The external oblique, internal oblique, and transverse abdominis muscles were measured in the supine position, while the erector spinae and multifidus muscles were measured in the prone position. The data were analyzed using the SPSS ver 21.0 statistical program. The difference in thickness between the right and left sides of the trunk muscle was analyzed by repeated measures analysis. The statistical significance level was set to p<0.05. Results: The results showed that the slashpipe exercise reduced significantly the difference in thickness of the oblique internus and erector spinae muscles compared to the weight bar exercise. Conclusion: The chaotic fluidity of the fluid filled inside the slashpipe could be used as sensory feedback information on body mal-alignment, which would have positively affected the symmetrical contraction of the trunk muscles as a trigger for self-correction. Therefore, it will have a useful effect not only on the health of the general public, but also on low back patients and athletes with muscle asymmetry.

플랭크 운동 시 척추세움근과 허리네모근 키네시오 테이핑 적용 및 지지면 조건이 복부 근 활성도에 미치는 영향 (Effect of erector spinae and quadratus lumborum kinesio taping and support surface conditions on abdominal muscle activity during plank exercise)

  • 김동훈
    • 대한물리치료과학회지
    • /
    • 제29권1호
    • /
    • pp.55-63
    • /
    • 2022
  • Background: This study investigated the effect of erector spinae and quadratus lumbar kinesio taping and support surface conditions on abdominal muscle activity during plank exercise. Design: Within-Group design. Methods: A total of twenty-three healthy men and women participated in this study. Abdominal muscle (both external obliques and internal oblique muscle) contraction was analyzed through EMG measurement with the presence or absence of kinesio taping applied to the erector spinae muscle and quadratus lumborum muscle during plank exercise and the difference between the support surfaces (stable surface and unstable surface) as variables. Abdominal EMG was attached to the right external oblique, left external oblique, right internal oblique, and left internal oblique. Results: The results showed that Abdominal left and right external obliques and internal obliques showed significant increases in activity when kinesio taping was applied to the erector spinae and quadratus lumborum muscles and unstable ground (p<0.05). Conclusion: In this study, we confirmed that the activity of the abdominal muscles was significantly increased during the plank operation in the state where the kinesio tape was attached. In addition, it was confirmed that the activity of the abdominal muscles was significantly increased during the plank operation on the unstable surface. These results suggest that in the state of kinesio tape attached and instability, plank motion has a positive effect on abdominal muscle activity.

Effect of the Abdominal Bracing Maneuver on Muscle Activity of the Trunk and Legs during Walking in Healthy Adults

  • Park, Daechan;Lee, Miyoung;Chung, Yijung
    • Physical Therapy Rehabilitation Science
    • /
    • 제11권2호
    • /
    • pp.119-126
    • /
    • 2022
  • Objective: This study aimed to investigate the effect of the application of abdominal brace techniques on muscle activity of the trunk and lower extremities when walking. Design: Cross-sectional study Methods: This study was conducted on 26 healthy adults in their 20s, and the subjects performed two conditions in random order: walking with the abdominal bracing technique and walking in an abdominal relaxation state (normal gait). Muscle activity was measured on the dominant side of all subjects using surface electromyography, and the attachment sites were the erector spinae, external oblique, internal oblique, vastus lateralis, and vastus medialis oblique muscles. Each condition was measured three times to calculate and analyze the average value. Results: When walking using the abdominal brace technique, the muscle activity of the erector spinae, external oblique, internal oblique, and vastus lateralis increased significantly (p<0.05), and the muscle activity of the vastus medialis increased as well but was not significant. Conclusions: The results of this study indicate that it is possible to be used as an effective guide to increasing the muscle activity and stability of the trunk and lower extremities through the application of the abdominal bracing technique during walking.

OBLIQUE PROJECTIONS AND SHIFT-INVARIANT SPACES

  • Park, Sang-Don;Kang, Chul
    • Journal of applied mathematics & informatics
    • /
    • 제26권5_6호
    • /
    • pp.1207-1214
    • /
    • 2008
  • We give an elementary proof of one of the main results in [H.O. Kim, R.Y. Kim, J.K. Lim, The infimum cosine angle between two finitely generated shift-invariant spaces and its applications, Appl. Comput. Har-mon. Anal. 19 (2005) 253-281] concerning the existence of an oblique projection onto a finitely generated shift-invariant space along the orthogonal complement of another finitely generated shift-invariant space under the assumption that the generators generate Riesz bases.

  • PDF

A Numerical Study on Pontoon Type Floating Breakwaters in Oblique Waves

  • Kim, Do-Young
    • International Journal of Ocean Engineering and Technology Speciallssue:Selected Papers
    • /
    • 제3권1호
    • /
    • pp.23-28
    • /
    • 2000
  • A numerical investigation was made to examine characteristics of rectangular pontoon type floating breakwaters in oblique waves. Sway and heave wave exciting forces, roll moment acting on the floating breakwater and three motion reponses decrease as the incident wave angle increases for the most of the wave ranges. There exists a minimum wave transmission coefficient which is a function of wave frequency. In short wave range wave transmission coefficient increases as the incident wave angle increases. In long wave range, however, wave transmission coefficient decreases as the wave incident angle increases.

  • PDF

Transient Inferior Oblique Muscle Palsy Following Transconjunctival Lower Lid Blepharoplasty

  • Lee, Hye Jin;Rhiu, Soolienah;Oh, Dong Eun;Jeong, Jin Ho
    • 고신대학교 의과대학 학술지
    • /
    • 제33권2호
    • /
    • pp.208-214
    • /
    • 2018
  • Although the inferior oblique (IO) muscle is positioned considerably deep in the orbit, transconjunctival lower lid blepharoplasty may affect it and transient or permanent IO muscle palsy might result. Therefore diplopia should be explained before cosmetic blepharoplasty performed with transconjunctival approach.

톱밥 제조기용 3차원 절삭 헬리컬형 드럼의 개발 (Development of a Helical Type Drum with an Oblique Cutting Condition for the Sawdust Machine)

  • 오상엽;배용환;하민수
    • 한국산업융합학회 논문집
    • /
    • 제7권4호
    • /
    • pp.419-424
    • /
    • 2004
  • In order to increase the efficiency of the sawdust machine, the helical type drums with an oblique cutting condition (3D) were developed. The preexisting drums have an orthogonal cutting condition (2D) considering of a saw cutter and a wood cutting pattern. Unfortunately, the disadvantages of this type drum are the big cutting resistance, the high cost of a cutting power and the extreme occurrence of a vibration. To improve this shortcoming, the helical type drum with an oblique cutting condition was developed. Therefore, this type drum decreased the vibration and the cutting resistance of the sawdust machine, and also improved the productivity of 30% or more and the porosity of the sawdust.

  • PDF