• Title/Summary/Keyword: Objective lens

Search Result 223, Processing Time 0.026 seconds

Geometrical Characteristics of Dimer Liquid Crystals Comprising Comprising Carbonate Linkage (Carbonate-type 이량체액정의 기하학적 특징)

  • 남수용
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.13 no.1
    • /
    • pp.25-37
    • /
    • 1995
  • Today, regarded as a science in photography, the role of the lens and sensitizer is important. In this research, we manufactured simple test lens with a various diaphragm which is based on the general purpose lens, and measured the quantity of light and flare. The objective of this study is to figure out the characteristics of our test lens and maximize its usefulness. The results showed that (1) The quantity of light through the lens was not constant. (2) As for flare, its value was consist. (3) Our lens had the characteristics of the soft lens and (4) It had much chromatic abberation. Therefore, We found that a hand-made lens is to acquire visual image such as the effects of a specialized lens.

  • PDF

A study of glass molding the micro Blu-ray pick-up lens (초소형 블루레이 광 팍업 렌즈의 유리 성형에 관한 연구)

  • Park, S.S.;Lee, K.Y.;Kim, H.M.;Hwang, Y.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2006.05a
    • /
    • pp.164-167
    • /
    • 2006
  • Micro lens especially for optical pick up(Blu-ray) lens module is one of the key products for IT technology. Specific attention has been given to manufacturing of large radius lens but little to small radius less than 2mm diameter with N.A>0.8. This paper deals with a high precision glass molding technology for mass production of Blu-ray pick up lens. Ultra precisely machined tungsten carbide core and glass molding equipments are utilized for forming process. Evaluation was performed in terms of profile accuracy, surface roughness and thickness of fabricated glass lens.

  • PDF

Design of Optical Path for Small Form Factor Optical Disk Drive and Fabrication of Micro-Compensatory Lens (초소형 광 정보 저장 기기를 위한 광 경로 설계 및 마이크로 보정 렌즈 제작)

  • 김홍민;정경성;최우재;박노철;강신일;박영필
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.115-118
    • /
    • 2002
  • The purpose of this paper is to design a pick-up for the small form factor optical disk drive and to fabricate a micro-compensatory lens for the pick-up using the micro-compression molding process. At design stage, the optical elements including the objective lens and the compensatory lens are miniaturized. The height of pick-up and free working distance are designed as 2mm and 0.2% respectively. To analyze the fabricated micro-compensatory lens, the system was analyzed using the surface profile of the fabricated micro-compensatory lens and CODE V which is commercial software. The RMS wave front aberration of the system using fabricated micro-compensatory lens is 0.01677λ which is lower than Marechal's criterion, 0.07λ.

  • PDF

The Change in the Parameters of Silicone Hydrogel Lens and Objective/Subjective Symptoms induced by Repetitive Dryness of Lens (실리콘 하이드로겔 렌즈의 반복적 건조로 인한 렌즈형태 및 자·타각적 증상의 변화)

  • Kim, So Ra;Kang, Byeong Ho;Jung, In Pil;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.4
    • /
    • pp.381-388
    • /
    • 2012
  • Purpose: In this study, the changes in the shape of silicone hydrogel lenses, dryness of lens and objective/ subjective symptoms that could be induced by repeating dryness of lens and objective/subjective symptoms were investigated. Methods: After drying and rehydrating of silicone hydrogel lenses with different lens material and thickness for 4 times, their overall diameters and base curves were compared. Subjective symptoms, non-invasive tear break-up time (NIBUTs) and blinking rate were evaluated after wearing dehydrated silicone hydrogel lens. Results: Overall diameter and base curve increased in all tested silicone hydrogel lenses by repeating dryness and rehydration. The degree of change in over all diameter and base curve were variable on the material. There were irregular change of lens parameters in thicker lens. When the subjects wore silicone hydrogel lenses after drying and rehydrating, their NIBUTs were decreased and blink rates were increased regardless of lens material or thickness. In addition, repetitive drying of silicone hydrogel lenses affected the lens fitting. Therefore, subjective symptoms such as itching, pain, irritation, foreign body sensation, dryness tended to be increased. Conclusions: The results obtained from the study may suggest to develop durable silicone hydrogel contact lenses against dry environment since the changes in parameters of silicone hydrogel lens and the subjective discomfort were observed after repetitive drying and rehydration.

Development and Design of the Optical System of a Night Scope (Night Scope 광학계의 설계 및 개발)

  • Lee, Dong-Hee;Lim, Yang-Moo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.1
    • /
    • pp.11-17
    • /
    • 2004
  • We tried to design and manufacture a night scope which is used in the leisure sports field. The whole system consists of an IR light source part, an objective lens part, an intensifier tube part and an eye_piece lens part. We designed an objective lens part to the infinite object imaging optical-system with 80mm focal-length, 40mm effective-aperture and 14mm image-field-size of which the chromatic aberration is reduced by using materials of BK7 and FD4. The resolution of this system is about 25lines/mm at the 40% MTF value criterion. The eye_piece lens is adopted goods to be used commercially to save cost of production. The design technique which gets in this development will be utilized greatly in good developments of the dot, the sight and the day/night riflescope system at the hereafter.

  • PDF

A Single Lens Micro-Angle Sensor

  • Saito, Yusuke;Gao, Wei;Kiyono, Satoshi
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.8 no.2
    • /
    • pp.14-19
    • /
    • 2007
  • Angle sensors based on the principle of autocollimation, which are usually called autocollimators, can accurately measure small tilt angles of a light-reflecting flat surface. This paper describes a prototype micro-angle sensor that is based on the laser autocollimation technique. The new angle sensor is compact and consists of a laser diode as the light source and a quadrant photodiode as a position-sensing device. Because of its concise design, the microangle sensor facilitates dynamic measurements of the angular error motions of a precision stage without influencing the original dynamic properties of the stage. This is because the sensor only requires a small extra target mirror to be mounted on the stage. The sensitivity of the angle detection is independent of the focal length of the objective lens; therefore, an objective lens with a relatively short focal length is employed to reduce the size of the device. The micro-angle sensor uses a single lens for the both the laser collimation and focusing, which distinguishes it from the conventional laser autocollimation method that has separate collimate and objective lenses. The new micro-angle sensor has dimensions of $15.1\times22.0\times14.0mm$ and its resolution is better than 0.1 arc-second The optical design and performance of this micro-angle sensor were verified by experimental results.

The Evaluation of Visual Quality by Employing Double-pass Principle in Circle Contact Lens Wearers after Refractive Surgery (시력교정술 후 써클콘택트렌즈 착용시 double-pass 원리를 이용한 시력의 질 평가)

  • Kwon, Ki Nam;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.277-284
    • /
    • 2015
  • Purpose: The study aimed to evaluate the effect of circle contact lens wearing on visual quality of the eyes after a refractive surgery. Methods: The objective visual quality was evaluated for 40 eyes who did not get refractive surgery and 30 eyes who got a refractive surgery after applying plano circle contact lenses on their eyes, respectively. Modulation transfer function (MTF), objective scatter index (OSI) and the focusing ratio on retina (Strehl ratio) were measured by using optical quality analysis system (OQAS) and the correlation between pupil size and objective visual quality was analyzed by measuring the pupil size. Results: When wearing circle contact lens on the eyes after refractive surgery, MTF and Strehl ratio were reduced and OSI was increased compared with the eyes without refractive surgery. The eyes after a refractive surgery showed more significant difference changes in MTF, OSI and Strehl ratio according to the pupil size compared with those without refractive surgery. Conclusions: The results showed that wearing of circle contact lens after the refractive surgery has deteriorated the objective visual quality based on the quality of focused image on the retina. Therefore, we suggest that sufficient understanding and consideration about the deterioration of visual quality is necessary in the case of circle contact lens wearing after refractive surgery.

The Analysis of position Sensitivity and Aberration characteristics of Liquid Crystal Elements (액정 소자의 위치 민감도 및 수차 특성에 대한 연구)

  • Heor Jae-Youn;Yoo Ho-Sik;Yoo Jang-Hoon;Park Soo Han;Jeong Soo-Jin
    • Transactions of the Society of Information Storage Systems
    • /
    • v.1 no.1
    • /
    • pp.78-83
    • /
    • 2005
  • The Blu-ray disc as a next generation high density optical medium uses an objective lens of high numerical aperture(NA 0.85) and blue laser in order to increase the recording density. The double layer is also useful for doubling the density. The spherical aberration of Blu-ray disc is very sensitive to the thickness of the disk because of high numerical aperture. This paper suggests a method to compensate the spherical aberration caused by the change of disk thickness, by using the Liquid Crystal lens instead of the Liquid Crystal panel. It was possible to develop both the LC panel generating the optical phase difference and LC lens changing the optical power. In this paper, we analyzed the aberration performance and a position sensitivity of the two type LC elements when the samples deviate from the optical axis of the objective lens. The results of applying this analysis show that the LC lenses rather than the LC panels have a significant assembling tolerance. The theoretical characteristics of the two elements are calculated and compared with the measurement data.

  • PDF

The Optical Design of Probe-type Microscope Objective for Intravital Laser Scanning CARS Microendoscopy

  • Rim, Cheon-Seog
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.4
    • /
    • pp.431-437
    • /
    • 2010
  • A stack of gradient-index (GRIN) rod lenses cannot be used for coherent anti-Stokes Raman scattering (CARS) microendoscopy for insertion to internal organs through a surgical keyhole with minimal invasiveness. That's because GRIN lens has large amount of inherent chromatic aberrations in spite of absolutely requiring a common focus for pump and Stokes beam with each frequency of ${\omega}_p$ and ${\omega}_S$. For this endoscopic purpose, we need to develop a long slender probe-type objective, namely probe-type microscope objective (PMO). In this paper, we introduce the structure, the working principle, and the design techniques of PMO which is composed of a probe-type lens module (PLM) and an adaptor lens module (ALM). PLM is first designed for a long slender type and ALM is successively designed by using several design parameters from PLM for eliminating optical discords between scanning unit and PLM. A combined module is optimized again to eliminate some coupling disparities between PLM and ALM for the best PMO. As a result, we can obtain a long slender PMO with perfectly diffraction-limited performance for pump beam of 817 nm and Stokes beam of 1064 nm.

Changes in Subjective Symptom, Tear Film Stabilization and Blinking Rates when Wearing RGP Lenses with Different Polishing Conditions for Certain Period of Time (연마상태가 다른 RGP렌즈의 일정기간 착용 시 렌즈착용자의 자각적 증상, 눈물막 안정 및 순목횟수 변화)

  • Park, Mijung;Kim, Hyo Gyum;Bae, Jun Seob;Park, Jung Ju;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.31-42
    • /
    • 2014
  • Purpose: The present study was conducted to investigate the effect of the physical properties of RGP lens induced by lens polishing on the actual wearer's subjective comfort, the tear film break-up time and the blinking rate as a follow-up study that revealed the relationship between the lens physical properties during lens manufacturing and lens wearer's factors. Methods: RGP lenses made from the three different polishing conditions (25, 50 and 100 seconds) were applied on 28 eyes of 17 subjects, aged 20 to 29 years, without any known disease and surgical history in the eyes. While the subjects were asked to wear the RGP lenses longer than a week, the questionnaire for the comfortability was administered everyday. Subjective and objective tear break-up time and blinking rate of the wearers were further measured. Results: The wearer's subjective comfortability showed some difference in the type of discomfort and satisfaction score according to the polishing status when wearing RGP lenses made from different polishing conditions longer than a week, and a bigger difference in satisfaction score induced by polishing condition was especially shown in experienced RGP lens wearer rather than un-experienced wearer. In the case of RGP lens wearer compared with the ones without the wearing experience, as the wearing time increased subjective and objective tear break-up time were increased and the blinking rate was decreased. However, subjective and objective tear break-up time were tended to decrease with even longer wearing time when wearing the RGP lens made from the polishment for 100 seconds. Conclusions: These results confirmed that the optimization of physical properties of the lens may not give the same effect on the wearer's subjective and objective symptoms and other factors when actual wearing. From the results, it can suggest that the success rate of RGP lens wear may be changed by physiological factors such as the stabilization of wearer's tear film, comfortability and lens wearing experience when wearing RGP lens based on 'The manufacturing standard for soft contact lens/hard contact lens' provided by Korea Food and Drug Administration.