• Title/Summary/Keyword: Objective Measurement

Search Result 1,923, Processing Time 0.031 seconds

Correlation between Subjective and Objective Measurement of Climacteric Women's Hot Flashes (갱년기 여성 안면홍조의 주관적 측정과 객관적 측정의 상관성)

  • Kim, Hyung-Jun;Leem, Kang-Hyun;Kim, Myoung-Hee
    • Journal of Korean Academy of Nursing
    • /
    • v.40 no.6
    • /
    • pp.765-774
    • /
    • 2010
  • Purpose: The purposes of this study were to explain the phenomena of hot flashes in climacteric women by using Mexameter, Skin Thermometer, Corneometer, and Laser Doppler Perfusion Imager (LDPI) objectively and to identify the interrelation between the subjective and objective measurements of hot flashes by comparing the two as reported in retrospective questionnaires. Methods: The participants were one hundred women (45-60 yr) who were not currently on hormone therapy, and had reached hot flash scores of 10 or higher. Hot flashes were measured in a temperature and humidity controlled room for 7 hr from 10 am to 5 pm. Hot flashes were measured subjectively and recorded via the Hot Flash Diary Report. When participants felt the hot flashes, they were measured objectively by Mexameter, Skin Thermometer, Corneometer, and LDPI. Results: The frequency of hot flashes in participants ranged from 1 to 7 times. When hot flashes occurred in participants, the erythema, skin temperature, skin hydration, and blood perfusion showed statistically significant changes in all measurements. But, the subjective and objective measurements of hot flashes showed only weak correlations. Conclusion: Results indicate a need for future research with subjective and objective measuring instruments chosen depending variations identified for the study.

Comparison of Subjective and Objective Sleep Quality in Subjects with and without Hyper-kyphosis

  • Kim, Jun-hee;Hwang, Ui-jae;Choi, Sil-ah;Jung, Sung-hoon
    • The Journal of Korean Physical Therapy
    • /
    • v.34 no.5
    • /
    • pp.272-277
    • /
    • 2022
  • Purpose: This study compared the subjective and objective sleep quality between subjects with and without thoracic hyper-kyphosis. Methods: Forty participants were divided into a hyper-kyphosis (n=17) and normal group (n=17) by thoracic spinal angle measurement. The subjective sleep quality was measured using PSQI, a self-report, and objective sleep quality was measured using an actigraphy that measures time according to sleep patterns. Results: The PSQI scores of subjects with thoracic hyper-kyphosis were significantly higher than those with normal thoracic curvature (p=0.013). The total sleep time and real sleep time were less in subjects with hyper-kyphosis than in normal subjects (p=0.006; p=0.029). The light sleep time was less in subjects with excessive spondylolisthesis than in normal subjects (p=0.010). Light sleep time was less in those with hyper-kyphosis, but deep sleep time was similar to the subjects with a normal thoracic curvature (p=0.003; p=0.140). Conclusion: Subjects with thoracic hyper-kyphosis had a decrease in subjective sleep quality, such as sleep discomfort, and objective sleep quality, such as a decrease in sleep time compared to normal subjects.

Study to the Effect of Involutional Blepharoptosis Surgery Using Objective and Subjective Parameters

  • Asamura, Shinichi;Wada, Yoshitaka;Tanaka, Saiichi;Saika, Shizuya
    • Archives of Plastic Surgery
    • /
    • v.49 no.4
    • /
    • pp.473-478
    • /
    • 2022
  • Background We investigate the effect of involutional blepharoptosis (IB) surgery based on dry eye symptoms by analysis using objective and subjective measures. Methods We recorded various parameters from patients that underwent levator advancement surgery for IB, totaling 125 eyes (total 65 patients, 5 unilateral, 60 bilateral). Subjective assessment comprised a questionnaire on dry eye-related quality of life score (DEQS), a summary score calculated from DEQS, and six-grade evaluation, the patient's own measure of eye comfort. Objective assessment comprised marginal-reflex distance-1 (MRD-1), measurement of tear film breakup time, and superficial keratopathy (SPK) existence by slit lamp microscope. Results Subjective assessments showed that IB patients had improvement of dry eye symptoms and eye comfort when surgery increased MRD-1. On the other hand, objective assessments showed that the presence of SPK is suspected when the postoperative MRD-1 level is 3 mm or higher. Conclusion IB surgery must not only increase MRD-1 value, but also to perform maintenance of the appropriate ocular surface condition. From our parameters, we suggest postoperative MRD-1 value should be maintained at < 3 mm to safe and effective of IB surgery.

Quantitative Evaluation of Median Nerve Motor Function in Carpal Tunnel Syndrome Using Load Cell : Correlation with Clinical, Electrodiagnostic, and Ultrasonographic Findings

  • Kim, Dong Hwan;Park, Sung Bae;Lee, Sang Hyung;Son, Young-Je;Chung, Gih Sung;Yang, Hee-Jin
    • Journal of Korean Neurosurgical Society
    • /
    • v.54 no.3
    • /
    • pp.232-235
    • /
    • 2013
  • Objective : Major complaints of carpal tunnel syndrome (CTS) are sensory components. However, motor deficit also impedes functional status of hand. Contrary to evaluation of sensory function, the objective, quantitative evaluation of median nerve motor function is not easy. The motor function of median was evaluated quantitatively using load cell and its correlation with findings of electrodiagnostic study (EDS) was evaluated. Methods : Objective motor function of median nerve was evaluated by load cell and personal computer-based measurement system. All of the measurement was done in patients diagnosed as having idiopathic CTS by clinical features and EDS findings. The strength of thumb abduction and index finger flexion was measured in each hand three times, and the average value was used to calculate thumb index ratio (TIR). The correlation of TIR with clinical, EDS, and ultrasonographic findings were evaluated. Results : The TIR was evaluated in 67 patients (119 hands). There were 14 males and 53 females, mean age were 57.6 years (range 28 to 81). The higher preoperative nerve conductive studies grade of the patients, the lower TIR was observed [p<0.001, analysis of variance (ANOVA)]. TIR of cases with thenar atrophy were significantly lower than those without (p<0.001, t-test). TIR were significantly lower in patients with severe median nerve swelling in ultrasonography (p=0.042, ANOVA). Conclusion : Measurements of median nerve motor function using load cell is a valuable evaluation tool in CTS. It might be helpful in detecting subclinical motor dysfunction before muscle atrophy develops.

Implementation of an Auditory Late Latency Response Measurement System for Researching Objective Tinnitus Detection Method (객관적 이명검사 연구를 위한 청성 후기 반응 측정 시스템의 구현)

  • Park, I.Y.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.7 no.1
    • /
    • pp.45-50
    • /
    • 2013
  • Recently, a method for detecting animal tinnitus objectively, gap prepulse inhibition of acoustic startling (GPIAS) were reported. However, the GPIAS method is difficult to be directly applied to human tinnitus research because measuring repeatedly startling responses evoked by more than 110 dB SPL acoustic stimuli for human is not easy. In this paper, the auditory late latency response (ALLR) measurement system which can measure conveniently evoked potentials involving the information about the brain cortical activity related with auditory psychologic phenomena such as a tinnitus has been implemented. By using the implemented system, 8 persons with normal hearing sense have been experimented to measure N1-P2 amplitudes of ALLRs evoked by gap prepulse based acoustic stimuli. Through the experimental results, the prepulse inhibitions of all the participants' N1-P2 responses have been observed and their characteristics were evaluated. And it is verified that our implemented system can be utilized as a device for researching and evaluating the objective tinnitus detection method in the future study.

  • PDF

Reliability and validity of pelvic mobility measurement using a cushion sensor in healthy adults

  • Jung, Seung-Hwa;Kim, Su-Kyeong;Lee, Ji-Hyun;Choi, Soo-Ih;Park, Dae-Sung
    • Physical Therapy Rehabilitation Science
    • /
    • v.9 no.2
    • /
    • pp.74-81
    • /
    • 2020
  • Objective: To prevent low back pain, an objective evaluation tool to evaluate pelvic mobility and exercise to improve the flexibility of the lumbar region is needed. The purpose of this study was to compare the results of pelvic mobility measurements using the Wii Balance Board (WBB) and Sensbalance Therapy Cushion (STC), evaluate the usefulness of the STC as a tool for measuring pelvic mobility. Design: Cross-sectional study. Methods: Fifty healthy subjects participated in this study. The subjects performed pelvic mobility range, proprioception, reaction time and reach of the arm using the STC. The pelvic movement parameter was measured two times to determine the intra-rater reliability. To measure the correlation between lumbar muscle tension and pelvic mobility, Myovision was used to measure tension of L4, L5 level erector spinae muscle. Correlations between measured variables were checked to determine the validity of the pelvic mobility assessment tool. Results: STC showed high test-retest reliability in pelvic tilt measurement and reaching task [intraclass correlation coefficients (3,1)=0.804-0.915]. The relationship between WBB and STC showed a significant positive correlation with the pelvic tilt and reaching task (p<0.05). Posterior tilt and erector spinae activation (Lt. L5) showed a significant negative correlation (p<0.05). Left, right tilt and erector spinae activation (L5) showed a significant negative correlation (p<0.05). Conclusions: This study confirmed the advantages of the STC and found efficiency as an objective measuring device of pelvic mobility.

Development of O-Ring Measurement Systems of Muscular Meridians for objectification of Constitutional Diagnosis (체질 진단의 객관화를 위한 O-Ring 경근 계측시스템의 개발)

  • 정동명
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.4
    • /
    • pp.555-561
    • /
    • 1995
  • In this paper, the O-Ring Measurement System (O-R MS) has been designed to supplement such subectivity and apply to the diagnosis by constitution. A single chip microprocessor of Intel MCS-51 family has been used to control the O-R MS and process data with real time, and the O-R MS could measure the minute muscular strength, expanded width between fingers, and time of the measurement. Therefore the objective constitutional diagnosis is possible by the O-R MS. As a clinical testing for estimating credibility of O-R MS, the acupuncture points representing the constitution has been stimulated using a semiconductor laser stimulator and measure the muscular strength by the O-R MS. The result of clinical testing has been shown that the constitutional diagnosis with the O-R MS is proved highly precision of 96% and it is expected that the O-R MS can be used practically for the objective constitutional diagnosis.

  • PDF

A Study on the Development of Diagnostic Model for Promotion of Management Innovation of Medium Enterprises (중견기업 경영혁신 촉진을 위한 진단모델 개발에 관한 연구)

  • Lee, Joon-Ho;Park, Kwang-Ho
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.36 no.3
    • /
    • pp.109-117
    • /
    • 2013
  • This study designed a "Diagnostic Model for Management Innovation of Medium Enterprises" based on the theoretical background of success factor and management diagnosis model for management innovation of medium enterprises and suggested a measure for utilization of strategic subject and diagnostic model that enterprises can apply. Utilization of medium enterprises management innovation diagnostic model designed through this study would be of help for making a diagnosis of the capability maturity level of enterprises' current management system and improving it by establishing a challenging capability objective and building a circulation system capable of innovating enterprises. It is expected for enterprises to overcome growing pains and establish a management system capable of achieving outcome (productivity) by repeating measurement and innovation through management diagnosis. In addition, this study provides a method to produce a strategic subject, select priority of implementation and prepare an implementation road map by classifying and filtering management issues produced as a result of management diagnosis in a systematic way. If variables necessary for production of an objective weighted value of scoring and discover of elements for category of diagnostic model and elementary items as well as design of a self-diagnosis questionnaire, measurement of management outcome suggested in this study can be able to be verified and supplemented through case study in the future, it is expected to make the degree of completion as a diagnostic model elevated that may help for growth and development through innovation of medium enterprises.

An Implementation of a GPIAS Measurement System for Animal Tinnitus Detection and Study on Effect of Starting Point of Stimulus Background Sound on Startle Response (동물 이명 검사용 GPIAS 측정 장치 구현과 이를 통한 자극 배경음의 시작 시점이 놀람 반응에 주는 영향)

  • Jeon, Poram;Jung, Jae Yun;Lee, Seung-Ha;Park, Ilyong
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.6
    • /
    • pp.410-414
    • /
    • 2013
  • As one of the effective methods for researching the objective tinnitus detection, the GPIAS (Gap Pre-pulse Inhibition of Acoustic Startle) measurement has been used to verify the existence of animal tinnitus objectively. The level and pattern of the background sound presented prior to a startle pulse are closely related with the GPIAS results. But the effect of the starting point of the background sound on animal startle responses has not been reported yet. In this paper, we present the implementation of a GPIAS measurement system based on an unconstrained enclosure to avoid animals' excessive constraint stress and deal with the animals' growth. After the performance of our implemented system has been tested through the animal experiment using 4 SD-rats, the effect of starting point of stimulus background sound on the startle response has been studied by the use of our implemented system. Through the results, it is verified that our system can measure the inhibition of animal startle responses due the gap pre-pulse for GPIAS calculation and the background sound starting point does not significantly effect on the startle response and the GPIAS values if the background sound continues for more than 300msec before a gap pre-pulse is presented.

A Systematic Review of the Attributes of Interior Design Affecting User's Positive Emotions Measured via Bio-Signals (생체신호 기반 사용자의 긍정적인 감정에 영향을 미치는 실내디자인 특성에 관한 문헌고찰)

  • Kim, Sieun;Ha, Mikyoung
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.36 no.5
    • /
    • pp.83-91
    • /
    • 2020
  • Environmental conditions are known to impact human health and behavior, emotions such as pleasure, anxiety, and depression, and reduce stress. Interior design that elevates emotional comfort and satisfaction can help improve mental health and well-being. This study is a systematic review that analyzed previous empirical studies that explored the effect of interior design elements on the user's emotional response which is quantitatively evaluated by bio-signal and qualitatively evaluated through self-reported questionnaire surveys. This paper aims to derive the attributes of interior design and biometric indicators that affect the user's positive emotion through the synthesis of previous studies and to confirm the feasibility of measuring bio-signals as an objective evaluation tool for architectural design and as a quantitative research method. As a result of the review, the biometric data from EEG, fMRI, ECG, EMG, GSR, and eye-tracking were used to measure the participants' emotional responses, which were manifested as positive or negative depending on certain attributes of interior design such as the form, color, lighting, material and furniture. The attributes of interior design related to the positive emotional response were the curved shape, high ceiling, openness of space, and subdued tone colors. Standard lighting conditions and wooden spaces were related to stress reduction in terms of comfort and relaxation. The free arrangement of furniture was related to the user's positive emotions. On the other hand, consistent experimental protocols could not be found, and although the sample sizes of the studies were small, the studies have demonstrated the feasibility of the emotional response measurement by using the biometric data. Therefore this method can be a useful objective tool in the measurement of human-centric data in architectural design, and to develop the evidence-based design to induce positive emotions and minimize stress.