• Title/Summary/Keyword: ORP

Search Result 228, Processing Time 0.027 seconds

Nitrogen removal characteristics of pigment wastewater using PAC-A/O process (PAC-A/O 공정을 이용한 안료폐수의 질소 제거 특성)

  • Jeong, Jongsik
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.1
    • /
    • pp.19-25
    • /
    • 2018
  • The objectives of this study were to evaluate the removal characteristics of total nitrogen, the influence factor of denitrification and the optimum operating condition in the pigment wastewater treatment using PAC-A/O process. The operating conditions of PAC-A/O process were mean BOD volumetric loading $0.86kgBOD/m^3/day$, mean F/M ratio 0.072~0.13 kgBOD/kgMLVSS/day and mean C/N ratio 3.47, respectively. The conditions of anoxic process in the field plant test were mean pH 8.3~8.7 and mean temperature $34.1{\sim}44.0^{\circ}C$. The ORP bending point knee was eventually appeared in the ORP -107 mV and $NO_3{^-}-N$ removal efficiency was increased according to the ORP decrease. In the ORP -107 mV below condition, the removal efficiency of T-N and $NO_3{^-}-N$ was 92.3~95.0% and 98.5~99.7%. Denitrification rate was calculated to be 1.581~1.791 mg $NO_3{^-}-N/gMLSS/hr$. The experimental results showed that the ORP control in the PAC-A/O process could be an effective method for treatment of pigment wastewater.

Operation diagnostic based on PCA for wastewater treatment (PCA를 이용한 하폐수처리시설 운전상태진단)

  • Jun Byong-Hee;Park Jang-Hwan;Chun Myung-Geun
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.16 no.3
    • /
    • pp.383-388
    • /
    • 2006
  • SBR is one of the most general sewage/wastewater treatment processes and, particularly, has an advantage in high concentration wastewater treatment like sewage wastewater. A Kernel PCA based fault diagnosis system for biological reaction in full-scale wastewater treatment plant was proposed using only common bio-chemical sensors such as ORP(Oxidation-Reduction Potential) and DO(Dissolved Oxygen). During the SBR operation, the operation status could be divided into normal status and abnormal status such as controller malfunction, influent disturbance and instrumental trouble. For the classification and diagnosis of these statuses, a series of preprocessing, dimension reduction using PCA, LDA, K-PCA and feature reduction was performed. Also, the diagnosis result using differential data was superior to that of raw data, and the fusion data show better results than other data. Also, the results of combination of K-PCA and LDA were better than those of LDA or (PCA+LDA). Finally, the fault recognition rate in case of using only ORP or DO was around maximum 97.03% and the fusion method showed better result of maximum 98.02%.

Mathematical Approach for Environmental Impact Analysis of Soils from Abandoned Mines (폐광산주변 토양의 환경영향해석을 위한 수학적 접근)

  • Kim, Kwang-Tae;Kang, Mee-A
    • The Journal of Engineering Geology
    • /
    • v.18 no.3
    • /
    • pp.297-302
    • /
    • 2008
  • The main reason of the pollution caused by soils and tailings located at discussed mines is heavy metals and AMD(acid mine drainage). Human health is affected by these pollutants which are spreaded from the abandoned mines. In this study, we try a mathematical approach to predict the pollution level of heavy metals caused by the surrounding soils of abandoned mines. The new approach is established with the correlation between the distance and pH, ORP. The change of pH and ORP can be described by the rate of initial values to experimental values. We demonstrate a realistic possibility of the mathematical approach to assess an environmental impact from disused mines cause the rate range is 0.95 to 1.03 for 60 days. Therefore our proposed approach will be useful as a few promising method for the management of heavy metals in many mines.

Evaluation of the Stability of Oxidation-Reduced Potential (ORP) Using the Filter of the Alkaline Water (알칼리 환원수 필터의 산화환원전위 안정화 평가)

  • Nam, Sangyep;Kwon, Yunjung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.8
    • /
    • pp.129-135
    • /
    • 2016
  • This study is about ionic water generator filter Recently, a lot of people feel deep interest in health and drinking water. Evaluation of the stability of oxidation-reduced potential (ORP) using the filter of the alkaline water. This study utilizes the three filter of activated carbon, UF, carbon block in alkaline reduced water equipment. Passing the water to the filter is evaluated that the OPR values are stability in accordance with the change of the volume in the bucket. Alkaline reduced water equipment is a system that has the function of making the water reduction. This system is the values of the human body beneficial minerals and ORP are made in the functional water has a very low value than general water. Which has passed through the filter the water in the water negative ions and positive ions through the electrolytic. After electrolysis, the cathode side by water, including $Ca^+$, $K^+$, $Mg^+$, $Na^+$ water gets Alkaline Reduced Water containing the minerals beneficial to the human body. A positive electrode side is made of the organic materials that have an anion such as chlorine (Cl), phosphorus (P), sulfur(S). This experiment uses the Alkaline Reduced Water to adjust the magnitude of the voltage of the electrolysis in the Alkaline Reduced Water. That is 1st step(pH8) 2nd step (pH8.5) 3th step (pH9), 4th step (pH9.5) in the Alkaline Reduced Water and -1st step (pH6.0), -2nd step (pH5.0) used as the acidic oxidation water. When the water passes through the three filter in this system was evaluated whether the ORP values are changed and stabilized. When about 100 liters of water passing through the filter was confirmed that the ORP values are stability and evaluation.

A Study on SUS MASK Etching Using Additives (첨가제를 이용한 SUS MASK 에칭에 관한 연구)

  • Lee, Woo-Sik
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.4
    • /
    • pp.243-248
    • /
    • 2022
  • The purpose of this paper is to etching SUS MASK by adding an additive (F300) to FeCl3. The equipment used in the experiment is a self-made automatic liquid management system. The automatic liquid management system is a device capable of controlling the Oxidation Reduction Potential (ORP) and specific gravity in real time and supplying FeCl3 and additives in a quantitative manner. SUS MASK was etched in units from 10 sheets up to 200 sheets for 1 minute. It was confirmed that when the initial SUS MASK was 10 sheets, the ORP value started with 628 mV and measured at 611 mV from the time of 40 sheets being injected, and maintained close to 610 mV up to 200 sheets. The specific gravity was maintained near 1.640. And the SUS MASK was measured close to 0.4 mm from 50 sheets to 200 sheets. The experimental conditions of ORP had a specific gravity of 610 mV, 1.463, an etching pressure of 3.0 kg/cm2, an additive (F300) ratio of 1.2%, and the hole size was measured by up to 200 sheets of 10 sheets at once etching. As a result, the diameter approached 0.4 mm from 20 sheets. Even if the number of SUS MASK was increased, the ORP and specific gravity were well controlled, and it was confirmed that the experimental target value was close to 0.4 mm.

Effect of Oxidation-Reduction Potential on Denitrification by Ochrobactrum anthropi SY509

  • Song, Seung-Hoon;Yeom, Sung-Ho;Choi, Suk-Soon;Yoo, Young-Je
    • Journal of Microbiology and Biotechnology
    • /
    • v.13 no.3
    • /
    • pp.473-476
    • /
    • 2003
  • The effect of oxidation-reduction potential (ORP) level on the denitrification by Ochrobactrum anthropi SY509 was investigated under nongrowing condition. The maximum ORP level of nitrate-containing buffer solution was -70∼-80 mV, under which the denitrification took place. By decreasing the initial ORP level, denitrifying enzyme activity was greatly enhanced, which led to higher denitrification efficiency.

Optimal Routing of Distribution System Planning using Hopfield Neural Network (홉필드 신경회로망을 이용한 배전계통계획의 최적 경로 탐색)

  • Kim, Dae-Wook;Lee, Myeong-Hwan;Kim, Byung-Seop;Shin, Joong-Rin;Chae, Myung-Suk
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1117-1119
    • /
    • 1999
  • This paper presents a new approach for the optimal routing problem of distribution system planning using the well known Hopfield Neural Network(HNN) method. The optimal routing problem(ORP) in distribution system planning(DSP) is generally formulated as combinational mixed integer problem with various equality and inequality constraints. For the exceeding nonlinear characteristics of the ORP most of the conventional mathematical methods often lead to a local minimum. In this paper, a new approach was made using the HNN method for the ORP to overcome those disadvantages. And for this approach, a appropriately designed energy function suited for the ORP was proposed. The proposed algorithm has been evaluated through the sample distribution planning problem and the simulation results are presented.

  • PDF

Optimal Routing Based on Genetic Algorithms for Distribution System Planning (유전 알고리즘을 이용한 배전 계통 계획의 최적 경로 탐색)

  • Kim, Min-Soo;Kim, Byung-Seop;Shin, Joong-Rin;Yim, Han-Suck
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.137-140
    • /
    • 1999
  • This paper presents an application of the Genetic Algorithms(GA) to solve the optimal routing problem(ORP) in power distribution system planning. Since the ORP is, in general, modeled as a mixed integer problem with some various mathematical constraints, it is hard to solve. In this paper, a new approach was made using the GA method for the ORP to overcome the disadvantages which many conventional methods generally have. For this approach, proposed was in this study a appropriately designed fitness function suited for the ORP. The proposed algorithm has been tested in sample network and the results are presented.

  • PDF

Oxygen Real-time Monitoring System using RGB Sensor toward PCB Manufacturing (PCB 제조공정을 위한 RGB 센서의 실시간 모니터링 시스템)

  • Anh, Jong-Hwan;Lee, Seok-Soon;Kim, Yi-Cheol;Hong, Sang-Jin;Soh, Dea-Wha
    • Journal of the Speleological Society of Korea
    • /
    • no.79
    • /
    • pp.73-75
    • /
    • 2007
  • 과거 PCB 제조의 주된 화제는 다양한 산업분야의 발전을 위해 한정된 시간 안에 좀 더 많은 PCB를 양산하는 기술 개발에 집중되어 있었지만, 현재는 비정상적인 공정 상태를 파악함으로써 제조 공정 환경에서의 오류를 줄여 전체 수율을 높이는 방법에 시선을 돌리고 있다. PCB 에칭의 경우 에칭 용액의 상태를 실시간으로 모니터링 하는 것이 중요하다. 본 논문에서는 기존 애칭용액의 상태를 판단할 때 사용되는 ORP센서 대신, RGB센서를 이용하여 실시간으로 용액의 상태를 모니터링 할 수 있는 시스템을 개발하였다. 개발된 시스템을 이용하여, 기존 ORP시스템과의 비교 분석을 및 RGB 센서를 이용한 모니터링 방법이 ORP센서를 이용한 방법 보다 좀 더 쉽고 정확하게 에칭 액의 상태를 모니터링 할 수 있다는 것을 확인하였다.

A Study on Autocontrolled SBR for Biological Nutrient Removal with External Carbon Sources (외부탄소원 주입시 영양염류의 생물학적 제거를 위한 자동제어 SBR 공정에 관한 연구)

  • Lee, Byung-hun;Kang, Seong-jae;Lim, Sung-il;Yoo, Pyung-jong
    • Journal of Korean Society on Water Environment
    • /
    • v.18 no.4
    • /
    • pp.371-377
    • /
    • 2002
  • The purpose of this study is to develop effective operating process in order to achieve more suitable conditions of Anoxic-Oxic-Anoxic-Stripper(AOAS) SBR through real-time control. To improve the removal efficiency, glucose, methanol and synthetic food waste acid fermentant were added as an external carbon source, In the case of glucose and synthetic food waste acid fermentant, TN, TP were removed to average 86.9%, 73.0% respectively. Methanol was removed to average 64.6%, 55.4% respectively. The synthetic food waste acid fermentant proved to be the most efficient and allowed for the substitution of an external carbon source. The removal rate of $COD_{Cr}$, was approximately 90% at all cases. The results of the study that a correlation between ORP (Oxidation-Reduction Potential), pH and DO and nitrification or denitrification when an external carbon source is added and when it isn't was showed that ${\Delta}ORP$ is suitable parameter. ORP reacted properly to denitrification (${\Delta}ORP<-10$) and nitrification (${\Delta}ORP<0$). The use of real-time control saved anywhere between 61 and 67 minutes at the anoxic(1) stage and 26 to 52 minutes at the oxic(1) stage. When the time saved from the anoxic(1) and oxic(1) was added to the anoxic(2) stage for the removal efficiency of TN and TP increased from 0.7 to 13.9% and 12 to 35 % respectively.