• 제목/요약/키워드: ORP

Search Result 228, Processing Time 0.026 seconds

Environmental Contamination from Acid Mine Drainage (산성광산배수로 인한 환경오염도 조사)

  • Kang, Mee-A
    • The Journal of Engineering Geology
    • /
    • v.17 no.1 s.50
    • /
    • pp.143-150
    • /
    • 2007
  • AMD (Acid mine drainage) from disused mines is one or the most significant pollutant problems to make harmful effect to human health. We demonstrated the mechanism of resolution and adsorption reaction for arsenic, manganese and zink from the soil and mine tailings which were located in the vicinity of a disused mine in Kyoungnam area. The resolution experiments were carried with a column test f3r 45 days continuously. Metal chemical forms in water were changed with the condition of solution pH and ORP (oxidation-reduction potential). Metal chemical forms affected on the reaction of resolution and adsorption of metals in water environments. Even though the sampling was carried in very closed location, there was significant different results of pollution level and ORP changes in terms of column operations. Hence It was important to note the pH and ORP in AMD to evaluate a risk assessment and a soil management using monitoring metals. When we operate AMD management with the mechanism of resolution and adsorption it can be achieved better economic solution.

Development of a Diagnosis Algorithm of Influent Loading Levels Using Pattern Matching Method in Sequencing Batch Reactor (SBR) (연속회분식반응기에서 패턴매칭방법을 이용한 유입수 부하수준 진단 알고리즘 개발)

  • Kim, Ye-Jin;Ahn, Yu-Ga;Kim, Hyo-Su;Shin, Jung-Phil;Kim, Chang-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.2
    • /
    • pp.102-108
    • /
    • 2009
  • DO, ORP and pH values measured during SBR operation can provide information about removal reaction of organic contaminants and nutrient materials in the reactor. It is already generalized control strategy to control reaction phase time using their special patterns indicating the end of the removal reactions. However, those informations are limited to point out the end time of oxidative reaction in the aerobic phase or reductive reaction in the anoxic phase without giving quantitative value of influent loading level. In this research, a diagnosis algorithm which can estimate the loading level of carbon and ammonia as high, medium and low was developed using the basic measurements like DO, ORP, and pH. It will be possible to know the level of influent loading rate from those online measurements without experimental analysis.

A Study on the Microorganism Disinfection and Characteristics of Discharged Water of Dielectric Barrier Discharge Plasma Systems (유전체 장벽 방전 플라즈마 방전수의 특성과 미생물 소독에 관한 연구)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.2
    • /
    • pp.159-165
    • /
    • 2012
  • Objectives: This experiment was carried out to elucidate the effect of discharged water on the disinfection of $Phytophthora$ $capsici$ and evaluate the water characteristics. Methods: The dielectric barrier discharges (DBD) plasma reactor system used in this study consisted of a plasma component [discharge, ground electrode and quartz dielectric tube], high voltage source, and air supply. The effects of water characteristics such as pH, ORP and conductivity and the disinfection effect of discharged water were investigated. Results: Experimental results showed that in the process of discharge, the pH decreased, whereas ORP and electric conductivity increased. When the discharge time was 30 min, $Phytophthora$ $capsici$ of 2.94 log was disinfected within 300 seconds. Disinfection performance of stored discharged water was maintained for three days; however the disinfection effect vanished after five days. When $Phytophthora$ $capsici$ was injected into the discharged water, the disinfection effect decreased after two days. Conclusions: It is considered that the main disinfection parameters of the discharged water were chemically active species such as $H_2O_2$ and $O_3$ and high ORP.

A Study on environmental-friendly Cleaning for Si-wafers (환경친화적인 실리콘 웨이퍼 세정 연구)

  • Yoon, Hyoseob;Ryoo, Kunkul
    • Clean Technology
    • /
    • v.6 no.1
    • /
    • pp.79-84
    • /
    • 2000
  • In this study, to reduce the consumption of chemicals in cleaning processes, Si-wafers contaiminated with metallic impurities were cleaned with electrolyzed water(EW), which was generated by the electrolysis of a diluted electrolyte solution or ultra pure water(UPW). Electrolyzed water could be controlled for obtaining wide ranges of pH and ORP(oxidation-reduction potential). The pH and oxidation-reduction potential of anode water and cathode water were measured to be 4.7 and +1000mV, and 6.3 and -550mV, respectively. To analyze the amount of metallic impurities on Si-wafer surfaces, ICP-MS was introduced. Anode water was effective for Cu removal, while cathode water was more effective for Fe removal.

  • PDF

A Comparison of Nutrients Removal Characteristics by the Variation of Organics in $A_{2}O$ SBR and $A_{2}O$ SBBR for the Small Sewerage System (소규모 오수처리를 위한 $A_{2}O$ SBR과 $A_{2}O$ SBBR에서 유입 유기물 농도변화에 따른 염양염류 제거 특성 비교)

  • Park, Young-Seek;Jeong, No-Sung;Kim, Dong-Seog
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.5 s.92
    • /
    • pp.451-461
    • /
    • 2006
  • Laboratory scale experiments were conducted to study the conversion of sludge from conventional activated sludge to nitrogen-phosphorus removal sludge using two types of sequencing batch reactor (SBR) systems, a conventional SBR and sequencing batch biofilm reactor (SBBR). The nitrogen and phosphorus removal characteristics were similar between SBR and SBBR and the removal efficiencies were very low when the influent TOC concentrations were low. The nitrogen and phosphorus removal efficiencies in SBR were 96% and 77.5%, respectively, which were higher than those in SBBR (88% and 42.5%) at the high influent TOC concentration. In SBBR, the simultaneous nitrification-denitrification was occurred because of the biofilm process. The variations of pH, DO concentration and ORP were changed as the variation of influent TOC concentration both in SBR and SBBR and their periodical characteristics were cleary shown at the high influent TOC concentration. Especially, the pH, DO concentration and ORP inflections, were cleary occurred in SBR compared with SBBR.

Development of Water Treatment Device By Fluidization Electrolysis Using Granular Ceramics

  • Ishikawa, Katsumi;Tamura, Rokurou;Shuto, Rika;Miyawaki, Jinuchi;Tanabe, Kimiko
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1996.06c
    • /
    • pp.737-745
    • /
    • 1996
  • In recent years, with the increase in the consumption of natural resources and energy, global environmental problems have appeared. This is a very serious environmental load on worldwide food production. For this reason, innovative techniques for production of low entropy by using effectively the energy for the ecosystemic agriculture have been expected. In this study, granular ceramics of 2 to 3mm in diameter having electrical charges at the surface were produced, using the natural raw materials of silicate minerals haing excellent moldabilities and sintering properties . Production of water having functions was attempted by effective use of the electrochemical energy of the ceramics with an efficient water treatment apparatus in which the ceramics were fluidized in water, differently from conventional systems. In the experimental results, the EC of water treated with the ceramics was not changed, but the ORP and also the pH and the DO were changed. The speed of oxidation -re uction reaction was high, and the ceramics -treated water enhanced the vigor of seeds. It can be expected that this treatment system, by which the ORP of water can be moderately controlled, is advantageous in controlling the growth of plants.

  • PDF

Rehabilitation Priority Decision Model for Sewer Systems (하수관거시스템 개량 우선순위 결정 모형)

  • Lee, Jung-Ho;Park, Moo-Jong;Kim, Joong-Hoon
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.6
    • /
    • pp.7-14
    • /
    • 2008
  • The main objective of sewer rehabilitation is to improve its function while eliminating inflow/infiltration (I/I). If we can identify the amount of I/I for an individual pipe, it is possible to estimate the I/Is of sub-areas clearly. However, in real, the amount of I/I for an individual pipe is almost impossible to be obtained due to the limitation of cost and time. In this study, I/I occurrence of each sewer pipe is estimated using AHP (Analytic Hierarch Process) and RPDM (Rehabilitation Priority Decision Model for sewer system) was developed using the estimated I/I of each pipe to perform the efficient sewer rehabilitation. Based on the determined amount of I/I for an individual pipe, the RPDM determines the optimal rehabilitation priority (ORP) using a genetic algorithm for sub-areas in term of minimizing the amount of I/I occurring while the rehabilitation process is performed. The benefit obtained by implementing the ORP for rehabilitation of sub-areas is estimated by the only waste water treatment cost (WWTC) of I/I which occurs during the sewer rehabilitation period. The results of the ORP were compared with those of a numerical weighting method (NWM) which is the decision method for the rehabilitation priority in the general sewer rehabilitation practices and the worst order which are other methods to determine the rehabilitation order of sub-areas in field. The ORP reduced the WWTC by 22% compared to the NWM and by 40% compared to the worst order.

Pollutant Monitoring of Abandoned Mines using the Leaching Test with Soils and Tailings (토양 및 광미의 용출실험을 이용한 폐광산오염수준의 모니터링)

  • Kang, Mee-A;Kim, Kwang-Tae
    • The Journal of Engineering Geology
    • /
    • v.17 no.3
    • /
    • pp.419-424
    • /
    • 2007
  • The contents were investigated by the monitoring survey from the soils and tailings caused by numerous abandoned mines in Korea. Cause heavy metals due to abandoned metal mines are raising significant environmental problems. But it is an important key such as a leaching and a transfer mechanism to evaluate contamination levels caused by abandoned mines. In this study the column test was carried in order to calculate a leaching level from soils and tailings. It was demonstrated that the leaching of Pb, Cd and Mn was expressed with similar behaviors and that of As and Cu was expressed with similar behaviors. For Zn, the leaching behavior was shown a serious leaching level with 40 mg/kg during the 45days. This was explained by Zn high contents of soils Zn in a natural world and ORP conditions where the leaching of Zn was occurred easily. Hence it was necessary that the survey of ORP was a key as well as total contents for the management of abandoned metal mines. We could estimate the chemical forms of heavy metals using the physical index such as ORP and pH and reduce the risk from heavy metals caused by abandoned metal mines.

개방형혁신의 공공연구부문 적용방안 연구: KIST ORP 사례를 중심으로

  • Lee, Chang-Geun;Gang, Dae-Sin;Jeong, Seon-Yang
    • Proceedings of the Korea Technology Innovation Society Conference
    • /
    • 2015.05a
    • /
    • pp.164-173
    • /
    • 2015
  • Since Henry Chesbrough coined the term "open Innovation", active theoretical and empirical research has been conducted in many sectors. In Korea, private business sector took an active role in open innovation research and its adaptation. However, many public research institutes failed to follow the private sector's suit because they compete each other for limited fund from Korean government. The present research analyzed Korea Institute of Science and Technology(KIST) Open Research Program which pioneered open innovation research by sharing KIST research fund with third party entities and proposed a way to apply the KIST case to other public sectors.

  • PDF