• 제목/요약/키워드: ON/OFF cell

검색결과 519건 처리시간 0.03초

쉐이퍼를 사용한 비디오 트래픽원의 다중화기 성능 분석 (Performance Analysis of the Multiplexer for Shaped Video Traffic Sources)

  • 이상천;홍정완;김제승
    • 산업공학
    • /
    • 제18권4호
    • /
    • pp.494-503
    • /
    • 2005
  • This paper considers the problem of performance analysis for the multiplexer, when homogeneous periodic on-off sources are statistically multiplexed. Periodic on-off source model is defined that on-period and off-period are repeated by once in a deterministic periodic time and in on-period, cell arrives with deterministic time interval. In order to reflect periodicity of source model, we consider two multiplexing situation, such as random multiplexing and synchronized multiplexing. In both case, we obtain the overload-period distribution in the multiplexer, and an approximate method using the overload period distribution is suggested for obtaining the CLP(Cell Loss Probability) in the buffer of the multiplexer. A numerical example using MPEG-I real traffic samples and the results are also presented.

이질적 ON/OFF 원을 입력으로 한 다중화 장치의 셀 손실률 계산을 위한 하이브리드 방법 (Hybrid Method to Compute the Cell Loss Probability in a Multiplexer with the Superposition of Heterogeneous ON/OFF Sources)

  • 홍정식;김상백
    • 산업공학
    • /
    • 제12권2호
    • /
    • pp.312-318
    • /
    • 1999
  • This paper considers the cell loss probability(CLP) in a multiplexer with the superposition of heterogeneous ON/OFF sources. The input traffic is composed of k classes. Traffic of class i is the superposition of M_(i) ON/OFF sources. Recently, the method based on the Markov modulated deterministic process(MMDP) is presented. Basically, it is the discretized model of stochastic fluid flow process(SFFP) and gives the CLP very fast, but under-estimates the CLP especially when the value of estimated CLP is very low. This paper develops the discretized model of Markov modulated Poisson process(MMPP). It is a special type of switched batch Bernoulli process(SBBP). Combining the transition probability matrix of MMDP and SBBP according to the state which is characterized by the arrival rate, this paper presents hybrid algorithm. The hybrid algorithm gives better estimate of CLP than that of MMDP and faster than SBBP.

  • PDF

The Effects of Peroxiredoxin III on Human HeLa Cell Proliferation

  • Choi, Soonyoung;Kang, Sangwon
    • IMMUNE NETWORK
    • /
    • 제3권4호
    • /
    • pp.276-280
    • /
    • 2003
  • Background: Peroxidases (Prx) of the peroxiredoxin family reduce hydrogen peroxide and alkyl hydroperoxides to water and alcohol respectively. Hydrogen peroxide is implicated as an intracellular messenger in various cellular responses such as proliferation and differentiation. And Prx I activity is regulated by Cdc-2 mediated phosphorylation. This work was undertaken to investigate the proliferation role of peroxiredoxin III as a member of Prx family in Prx III overexpressed HeLa cell line. Methods: To provide further evidence of proliferation, we selected Prx III stably expressed HeLa Tet-off cell lines. Cell proliferation was examined by using proliferation reagent WST-1 in the presence or absence of doxycycline. Prx III, 2-cys Prx enzymes exist as homodimer. The activation of Prx III heterodimer with induced and endogenous Prx III was examined by immunoprecipitation. Results: Immunoprecipitation analysis of the induced and endogenous Prx III with anti-myc showed that the induced wild type (WT) and dominant negative (DN) Prx III from HeLa Prx III Tet-off stable cell heterodimerized with endogenous Prx III each other. And the expression level of induced Prx III was examined after addition of doxycycline. By 72 hr, the expression level of induced Prx III was diminished gradually and the half-life of the induced wild type Prx III was approximately 17 hr. The proliferation experiment demonstrated that the relative proliferation value of induced and endogenous WT Prx III stable cell has no changes but the DN Prx III induced HeLa Tet-off stable cells were lower than endogenous Prx III. Conclusion: In conclusion, the HeLa dominant negative Prx III Tet-off stable cells were decreased the proliferation.

발생 중 마우스 망막에서 방향특이성 신경절세포의 NMDA R1 수용체의 시냅스 패턴 (Synaptic Pattern of NMDA R1 upon the Direction-Selective Retinal Ganglion Cells in Developing Mouse Retina)

  • 이지건;권오주;전창진
    • 한국안광학회지
    • /
    • 제18권4호
    • /
    • pp.533-540
    • /
    • 2013
  • 목적: 본 연구에서는 발생 중[태어난 지 5일(P5), 10일(P10)] 마우스 망막의 ON-OFF 방향특이성 신경절세포 수상돌기 상에서 NMDA R1 수용체의 시냅스 패턴을 연구하고자 하였다. 방법: ON-OFF 방향특이성 신경절세포는 Lucifer yellow를 주사하여 형태학적 특징으로 동정하였다. 이극세포로부터의 글루타메이트의 흥분성 유입을 확인하기 위해 membrane traffic motor 단백질 마커인 kinesin을 이용하였다. 결과: 본 연구에서 P5, P10의 ON-OFF 방향특이성 신경절세포를 동정할 수 있었으며, NMDA R1의 면역반응반점은 내망상층에서 강하게 나타났다. ON-OFF 방향특이성 신경절세포의 수상돌기상의 수용체의 분포패턴에서 방향특이성을 예측할 수 있는 어떠한 비대칭성도 발견하지 못하였다. 결론: 이극세포로부터의 글루타메이트성 자극유입은 P5, P10 단계에서 모두 균형적으로 유입되며, 방향특이성은 NMDA R1 수용체의 특이적인 패턴에 있지 않음을 밝혔다.

Compatibility of Lithium ion Phosphate Battery in Solar off Grid Application

  • Lakshmanan, Sathishkumar;Vetrivel, Dhanapal;Subban, Ravi;R., Saratha;Nanjan, Sugumaran
    • Journal of Electrochemical Science and Technology
    • /
    • 제13권4호
    • /
    • pp.472-478
    • /
    • 2022
  • Solar energy harvesting is practiced by various nations for the purpose of energy security and environment preservation in order to reduce overdependence on oil. Converting solar energy into electrical energy through Photovoltaic (PV) module can take place either in on-grid or off-grid applications. In recent time Lithium battery is exhibiting its presence in on-grid applications but its role in off-grid application is rarely discussed in the literature. The preliminary capacity and Peukert's study indicated that the battery quality is good and can be subjected for life cycle test. The capacity of the battery was 10.82 Ah at 1 A discharge current and the slope of 1.0117 in the Peukert's study indicated the reaction is very fast and independent on rate of discharge. In this study Lithium Iron Phosphate battery (LFP) after initial characterization was subjected to life cycle test which is specific to solar off-grid application as defined in IEC standard. The battery has delivered just 6 endurance units at room temperature before its capacity reached 75% of rated value. The low life of LFP battery in off-grid application is discussed based on State of Charge (SOC) operating window. The battery was operated both in high and low SOC's in off-grid application and both are detrimental to life of lithium battery. High SOC operation resulted in cell-to-cell variation and low SOC operation resulted in lithium plating on negative electrode. It is suggested that to make it more suitable for off-grid applications the battery by default has to be overdesigned by nearly 40% of its rated capacity.

Study on Soft-Switching Transformers Inductor Boost Converter for Fuel Cell Powered Railway Vehicle

  • Jung, No-Geon;Kim, Jae-Moon
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권6호
    • /
    • pp.2553-2560
    • /
    • 2018
  • In Korea, there are no instances where a hydrogen fuel cell power generation system has been used in a railway vehicle. Only the basic topology has been studied. In the previous study, conventional converters using a single switch were applied to the fuel cell power generation system. Therefore, current stress on the switch at converter on-off transitions would be large when controlling a large-capacity railway vehicle. In addition, since the input side ripple is also large, there is a problem with a shortening of the lifetime of both the fuel cell power generation system and the inductor. In this paper, a soft-switching transformer inductor boost converter for fuel cell powered railway vehicles was proposed. A technique to reduce both the switching current stress generated during on-off transitions, and the input ripple current flowing in the inductor were studied. The soft-switching TIB converter uses a transformer-type inductor to configure the entire circuit in an interleaved method, and reduces both input current ripple and the current ripple of the inductor and switch.

An Adaptive Hot-Spot Operating Scheme for OFDMA Downlink Systems in Vertically Overlaid Cellular Architecture

  • Kim, Nak-Myeong;Choi, Hye-Sun;Chung, Hee-Jeong
    • ETRI Journal
    • /
    • 제28권3호
    • /
    • pp.282-290
    • /
    • 2006
  • In vertically overlaid cellular systems, a temporary traffic concentration can occur in a hot-spot area, and this adversely affects overall system capacity. In this paper, we develop an adaptive hot-spot operating scheme (AHOS) to mitigate the negative effects from the nonuniform distribution of user location and the variation in the mixture of QoS requirements in orthogonal frequency division multiple access downlink systems. Here, the base station in a macrocell can control the operation of picocells within the cell, and turns them on or off according to the system overload estimation function. In order to determine whether the set of picocells is turned on or off, we define an AHOS gain index that describes the number of subcarriers saved to the macrocell by turning a specific picocell on. For initiating the picocell OFF procedure, we utilize the changes in traffic concentration and co-channel interference to the neighboring cells. According to computer simulation, the AHOS has been proved to have maximize system throughput while maintaining a very low QoS outage probability under various system scenarios in both a single-cell and multi-cell environments.

  • PDF

ON-OFF 입력을 갖는 유한 크기 ATM 다중화기의 큐잉분석 (Queueing Analysis of the Finite Capacity ATM Multiplexer with the ON-OFF Input)

  • 김승환;박진수
    • 한국통신학회논문지
    • /
    • 제18권6호
    • /
    • pp.889-894
    • /
    • 1993
  • ATM은 음성, 비데오, 벌크 데이타등과 같은 다양한 형태의 버스트 트래픽을 수용할 수 있다. ATM망에서 트래픽 소오스를 효과적으로 처리하거나 가능한한 대역폭 사용율을 증가시키기 위해서는 통계적 다중화 구조가 채택되어야 한다. 본 논문은 독립적인 입력 소오스를 갖고 유한개의 버퍼 크기를 갖는 큐잉 시스템에서 큐 상태분포를 계산하기 위한 효과적인 계산 절차를 논의하고, 이러한 반복적인 계산방법을 통해 셀 손실율을 정확하게 계산한다. 또한 동질의 ON-OFF 소오스를 갖는 ATM 다중화기에 대해 몇가지의 수치계산 예를 통해 셀 손실율의 특성을 조사해 본다.

  • PDF

디젤입자상물질필터의 기하학적 형상변화가 재생과정 중 활성화 특성 및 비정상 온도거동에 미치는 영향에 관한 수치적 연구 (Numerical Study on the Effect of Changes of Geometric Shape of Diesel Particulate Filter on Light-Off Characteristics and Transient Thermal Behavior during Regeneration)

  • 정수진;이상진;김우승;이춘범
    • 한국자동차공학회논문집
    • /
    • 제14권4호
    • /
    • pp.68-76
    • /
    • 2006
  • The minimization of maximum DPF wall temperature and the fast Light-off during regeneration are the targets for the high durability of the DPF system and the high efficiency of regeneration. In order to predict transient thermal response of DPF, one-channel numerical modeling has been adopted. The effect of the ratio of length to diameter(L/D), cell density, the amount of soot loading on temporal thermal response and regeneration characteristics has been numerically investigated under two different running conditions: city driving mode and high speed mode. The results indicate that the maximum wall temperature of DPF increase with increasing 'L/D' in 'High speed mode'. For 'City driving mode', the maximum wall temperature decreases with increasing 'L/D' in the range of $'L/D{\geq}0.6'$. The maximum temperature decreases with increasing cell density because heat conduction and heat capacity are increased. It is also found that the effect of amount of soot loading on light-off time is negligible.

SOFC 시스템의 장시간 운전 및 시스템 신뢰성 향상 (Long Term Operation and Improvement Reliability for SOFC System)

  • 이용;신석재;박세진;김민수;김현중;김준호;김인환;김용수
    • 한국수소및신에너지학회논문집
    • /
    • 제28권5호
    • /
    • pp.502-511
    • /
    • 2017
  • Design, manufacture and operate the 700W Solid oxide fuel cell system suitable for housing. Except for BOP not produced domestically, most of the domestic BOPs were applied as much as possible. Finally, the system size was 350 liter. System performance was electric efficiency 44.64%, thermal efficiency 40.99%, total efficiency 85.62% at certificate authority. The system was operated for 4,500 hours, this operation time include automatically system on/off, E-stop for emergency stop, load trip for blackout and inverter error. There were that the system on/off were 26 times. System performance remains intact after system on/off.