• Title/Summary/Keyword: OIL

Search Result 15,729, Processing Time 0.043 seconds

Changes in the Volatile Compounds of Artemisia capillaris Essential Oil during Storage (사철쑥 정유의 저장 중 향기성분 변화)

  • Chung, Mi-Sook
    • Korean journal of food and cookery science
    • /
    • v.23 no.4 s.100
    • /
    • pp.413-422
    • /
    • 2007
  • In this study, changes in the volatile compounds of Artemisia capillaris essential oil were investigated under six different storage conditions for 6 months. The essential oil was collected by steam distillation and analyzed by a gas chromatography-mass selective detector (GC-MSD). Seventy-five volatile compounds were identified from the fresh essential oil of Artemisia capillaris. During storage, the total levels of aldehydes, alcohols, and ketones slightly decreased and the level of hydrocarbons greatly decreased; the total level of esters also decreased in the essential oil. Notably, the levels of carvacrol, eugenol, myrcene, 1,8-cineole, caryophyllene, coumarin, ${\alpha}-thujone$, ${\beta}-thujone$, borneol, and ${\gamma}-terpinene$, known as antioxidants and antimicrobial agents, decreased during storage. Finally, aerobic storage conditions caused greater reductions in some compounds even at low temperatures.

Oil Whirl Effects on Rotor-Bearing System Identifications by Modal Testing

  • Jei, Yang-Gyu
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1991.04a
    • /
    • pp.105-110
    • /
    • 1991
  • Oil whirl effects on system identification during modal testings are discussed. When the forward rotating excitations act, the oil whirl effects seriously appear. But when the backward rotating and uni-directional excitations act, and the magnitude of forward excitation is small, oil whirl effect do not appear in forced response function. The results of simulation of oil whirl effects during modal testing are well coincident with those of experiments. With the uni-directional excitation technique the linearized dynamic coefficients of fluid film bearings and seals can be estimated more accurately than with the circular rotating excitation technique. But with the circular excitation technique oil whirl effects can be well investigated.

  • PDF

The Changes of Mechanical Properties of Used Oil in Gasoline Engine (가솔린 엔진오일의 사용에 따른 기계적 성질의 변화에 관한 연구)

  • 강석춘;신성철;김동길;노장섭
    • Tribology and Lubricants
    • /
    • v.9 no.2
    • /
    • pp.36-48
    • /
    • 1993
  • This study is concerned with the changes (deterioration) of the mechanical properties of used oil in the gasoline engine. The analysed properties of used oil were friction, antiwear, wear debris, load-carrying ability and the formation of surface film. From this study, it was found that the oil used in engine was deteriorated to increase the wear and fricion and decrease the load-carrying ability as the running distance of oil was increased. Also the main cause of deterioration was related to the formation of the protective film on the contact zone. When the film was composed with rich additives (sulfur), this could properly protect contact zone from the increase of wear and friction. But as oil was deteriorated, it could not form such a film and therefore the protective ability of sliding surface diminished.

Measurement Of The Engine Oil Relative Dielectric Constant With Respect To Capacitive Prove Dimension (정전용량 프로브 크기에 대한 엔진오일 상대 유전율 측정)

  • Kim, Ki-Hoon;Kim, Young-Ju
    • Tribology and Lubricants
    • /
    • v.27 no.4
    • /
    • pp.209-212
    • /
    • 2011
  • The capacitive application(prove) can be used to measure the complex permittivity of dielectric material of various thickness and cross section. This paper presents that we designed the analysis system of engine oil permittivity to know the relation between the engine oil deterioration and the prove dimension. Each of the dimension of capacitive prove is changed and then electric capacity is measured by LCR {Inductance(L), Capacitance (C), and Resistance (R)} meter. The engine oil permittivity has extracted in the prove measurement. As the additional research, this paper suggest the best of the prove dimension for the permittivity measurement.

The Effect of Dimensions and Location of Oil Grooves on the Static Performance of a Cylindrical Journal Bearing (급유홈의 크기와 위치가 원통형 저널 베어링의 정적성능에 미치는 영향)

  • Son, Sang-Ik;Kim, Kyung-Woong
    • Tribology and Lubricants
    • /
    • v.26 no.4
    • /
    • pp.209-218
    • /
    • 2010
  • In this study, the effect of dimensions and location of oil grooves on the static performance of a cylindrical journal bearing is analyzed numerically. Axial length, circumferential length and location of oil grooves are considered as parameters. Cavitation occurs within the diverging region of a journal bearing. The distribution of cavitation region where cavitation occurs varies with dimensions and location of oil grooves and affects the performance of a journal bearing. Elrod's cavitation algorithm which implements JFO boundary conditions based on the principle of mass conservation at the interfaces between cavitation and full film region is adopted in order to consider the effect of cavitation. The result shows that parameters, especially location of oil grooves have a great effect on the static performance of a journal bearing.

Tribological Properties of Aqueous Solutions Composed of Aminated Olive Oil Derivative (수용성 아민화 올리브유 유도체의 트라이볼로지적 특성고찰)

  • Choi, Ung-Su;Lee, Sang-Soon
    • Tribology and Lubricants
    • /
    • v.26 no.5
    • /
    • pp.272-276
    • /
    • 2010
  • Aminated oilve oil derivative as the new organic disperse phases of the water soluble metal working fluid has been synthesized and tribological properties of the aqueous solutions composed of aminated olive oil derivative investigated using Four Ball Wear Tester and Falex EP Tester. The formulated aqueous solutions showed higher antiwear and extreme pressure properties and also lower friction coefficient. On the basis of the the results, water soluble aminated oilve oil derivative showed excellent tribological properties due to the polarizability of oleic acid derivative composed of majority part in oilve oil.

Spray Characteristics in CI Engines Fuelled with Vegetable Oils and Its Derivatives

  • No, Soo-Young
    • Journal of ILASS-Korea
    • /
    • v.16 no.1
    • /
    • pp.15-26
    • /
    • 2011
  • In this article, spray characteristics in CI engines fuelled with vegetable oils and its derivatives will be reviewed. Of edible vegetable oils, soybean oil and rapeseed oil were mainly investigated. Of inedible vegetable oils, jatropha oil and used frying oil were main concern on the research on the spray characteristics in CI engine. Spray angle and spray penetration were mainly examined among the macroscopic spray characteristics and Sauter mean diameter was only investigated among the microscopic spray characteristics. There exist six different definitions of spray angle which should be examined. Neat vegetable oil and biodiesel fuels show smaller spray angle than diesel fuel. Biodiesel fuel and vegetable oils and its blend have a longer spray penetration than diesel fuel. However, biodiesel blends with diesel shows the similar spray penetration with diesel fuel. SMDs in the biodiesel spray, vegetable oils and its blends spray are higher than that in the diesel spray.

A Study on the Establishment of Oil Spill Response Measures in Yeosu Waters (여수해역에 있어서 기름유출에 대한 방제대책 수립에 관한 연구)

  • 국승기;윤종휘;김원돈;이상호
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.7 no.2
    • /
    • pp.23-37
    • /
    • 2001
  • Marine environment has been polluted and damaged by many sources such as industrial waste, natural seepage, oil spill and offshore production etc. Among them, oil spill from oil tankers is one of most harmful sources to marine lives as its input amount is huge at a limited area for short period. In Korea, the port of Yeosu is known to be very vulnerable to oil spill with large amount of petroleum transported across the harbour. In this regards, the author analyzed and reviewed marine environment and appropriate response to marine oil spill at this area. For these purposes, oceanographic and meteorologic features as well as regional characteristics of harbor facilities, shipping routes, marine traffic and fisheries were investigated, also traffic densities were analyzed in order to check marine accident probabilities making direct observations for 72 hours visual1y and by portable radar.

  • PDF

Prediction of Deformation of an Oil-fence by using Fluid$\cdot$Structure Interaction Method (유체$\cdot$구조물 상호 작용 기법을 이용한 오일 펜스의 변형 예측)

  • Kim T. G.;Kim W.;Hur N.
    • Journal of computational fluids engineering
    • /
    • v.5 no.3
    • /
    • pp.16-22
    • /
    • 2000
  • In the present study a method of computing fluid-structure interaction is presented to simulate the deformation shape of an oil fence which is used to contain or to divert the split oil in sea water. The computation is performed by taking into account of the force and moment balance in each computational element of the oil fence. The forces and moments acting on each element of the structure is computed from the flow analysis, which in turn is used to predict deformed shape of the structure until the procedure converges. The flexibility of the oil fence was also considered in the analysis. It is shown from the present study that the predicted deformed shapes agree quite well with the available experiment data.

  • PDF

Example study of the dissipation factor change according to the oil filtering in large oil-filled transformer (유입변압기 오일필터링에 따른 유전정접 변화사례 고찰)

  • Kong, Tae-Sik;Kim, Hee-Dong
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2035_2036
    • /
    • 2009
  • This paper is purpose to understand the dissipation factor properties of the oil-filled large transformer according to the oil filtering. In order to know the insulation characteristic change by insulating oil filtering, we carried out the insulation diagnostic test for the same transformer before oil filtering and after. The insulation diagnosis tests are consist of the megger, the polarization index, the AC current test, the dissipation factor test and the partial discharge test, Especially we took notice of dissipation factor change, we analyzed and made a comparison of the two cases test result.

  • PDF