• 제목/요약/키워드: OH lifetime

검색결과 188건 처리시간 0.02초

주류 섭취로 인한 대한민국 제천 시민의 메탄올 노출수준 평가 (Estimation of Methanol Exposure Level via Alcoholic Beverage Consumed by Jecheon Citizen, South Korea)

  • 오창환;이예지;민성희
    • 한국식품영양학회지
    • /
    • 제26권1호
    • /
    • pp.44-50
    • /
    • 2013
  • Quantitative analyses of naturally occurring methanol were performed for the alcoholic beverages commonly consumed in Jecheon, Chungbuk province, South Korea. The headspace analysis method was optimized for the low and high alcoholic beverages. The external standard method was applied due to the overlapping of 2-propanol and 2-butanol (the internal standard candidates) with target sample matrix peaks. The target samples were selected based on the retail sales amounts of alcoholic beverages in the largest retailer food-mart chain, Jecheon, Chungbuk province, South Korea. There was no sample containing methanol over 0.5 $mg/m{\ell}$, the Korean maximum level of methanol in alcoholic beverages (1.0 $mg/m{\ell}$ for fruit originated liquor etc). The total exposure amount of methanol via alcoholic beverages was estimated based on the daily alcohol consumption of 40 g. The hazard indices calculated by methanol RfD 0.5 mg/kg bw day (US EPA) and ADI 20 mg/kg bw day (proposed by Lachenmeier etc.) were 0.301 and 0.008, respectively. As with the hazard index, aggregate exposures below a HI of 1.0 will likely not result in adverse noncancer health effects over a lifetime of exposure. Then the methanol exposure via the alcoholic liquours might not hazard to Jecheon citizen.

THE KOMPSAT- I PAYLOADS OVERVIEW

  • Paik, Hong-Yul;Park, Gi-Hyuk;Youn, Hyeong-Sik;Lee, Seunghoon;Woo, Sun-Hee;Shim, Hyung-Sik;Oh, Kyoung-Hwan;Cho, Young-Min;Yong, Sang-Soon;Lee, Sang-Gyu;Heo, Haeng-Pal
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 1998년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.301-306
    • /
    • 1998
  • Korea Aerospace Research Institute (KARI) is developing a Korea Multi-Purpose Satellite I (KOMPSAT-I) which accommodates Electro-Optical Camera (EOC), Ocean Scanning Multi-spectral Imager (OSMI), and Space Physics Sensor (SPS). The satellite has the weight of about 500kg and will be operated on the 10:50 AM sun-synchronized orbit with the altitude of 685 km. The satellite will be launched in 1999 and its lifetime is expected to be over 3 years. The main mission of EOC is the cartography to provide the images from a remote earth view for the production of 1/25000-scale maps of KOREA. EOC collects 510 ~ 730 nm panchromatic imagery with the ground sample distance(GSD) of 6.6 m and the swath width of 17 km by push broom scanning. EOC also can scan $\pm$45 degree across the ground track using body pointing method. The primary mission of OSMI is worldwide ocean color monitoring for the study of biological oceanography. It will generate 6 band ocean color images with 800 km swath width and 1km GSD by whiskbroom scanning. OSMI is designed to provide on-orbit spectral band selectability in the spectral range from 400 nm to 900 nm through ground command. This flexibility in band selection can be used for various applications and will provide research opportunities to support the next generation sensor design. SPS consists of High Energy Particle Detector (HEPD) and ionosphere Measurement Sensor (IMS). HEPD has missions to characterize the low altitude high-energy Particle environment and to study the effects of radiation environment on microelectronics. IMS measures densities and temperature of electrons in the ionosphere and monitors the ionospheric irregularities at the KOMPSAT orbit.

  • PDF

Characteristics of Ocean Scanning Multi-spectral Imager (OSMI)

  • Cho, Young-Min;Yong, Sang-Soon;Woo, Sun-Hee;Lee, Sang-Gyu;Oh, Kyoung-Hwan;Paik, Hong-Yul
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 1998년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.319-324
    • /
    • 1998
  • Ocean Scanning Multispectral Imager (OSMI) is a payload on the Korean Multi-purpose SATellite (KOMPSAT) to perform worldwide ocean color monitoring for the study of biological oceanography. The instrument images the ocean surface using a whisk-broom motion with a swath width of 800 km and a ground sample distance (GSD) of < 1 km over the entire field-of-view (FOV). The instrument is designed to have an on-orbit operation duty cycle of 20% over the mission lifetime of 3 years with the functions of programmable gain/offset and on-board image data storage. The instrument also performs sun calibration and dark calibration for on-board instrument calibration. The OSMI instrument is a multi-spectral imager covering the spectral range from 400 nm to 900 nm using a CCD Focal Plane Array (FPA). The ocean colors are monitored using 6 spectral channels that can be selected via ground commands after launch. The instrument performances are fully measured for 8 basic spectral bands centered at 412nm, 443nm, 490nm, 510nm, 555nm, 670nm, 765nm and 865nm during ground characterization of instrument. In addition to the ground calibration, the on-board calibration will also be used for the on-orbit band selection. The on-orbit band selection capability can provide great flexibility in ocean color monitoring.

  • PDF

공황장애 환자에서 공존 주요 우울증과 연관된 임상요인들 (Clinical Factors Associated with Comorbid Major Depressive Disorder in Patients with Panic Disorder)

  • 장현채;임세원;신영철;신동원;오강섭
    • 대한불안의학회지
    • /
    • 제10권1호
    • /
    • pp.17-23
    • /
    • 2014
  • Objective : Panic disorders are frequently accompanied by major depressive disorder (MDD). There is insufficient information about which clinical factors in panic disorder are associated with comorbid MDD. The aim of this study is to identify clinical factors related with comorbid MDD in patients with panic disorder. Methods : Two experienced psychiatrists diagnosed panic disorder based on DSM-IV criteria. This diagnosis in the 275 subjects was confirmed again by Mini-International Neuropsychiatric Interview (MINI). Lifetime comorbid psychiatric diagnoses were examined by MINI. The Hamilton Depression Scale (HAMD), Hamilton Anxiety Scale (HAMA) and Panic Disorder Severity Scale (PDSS) were used to assess the severity of depressive, anxiety and panic symptoms. Results : The result of MINI showed that 95 patients (34%) with panic disorder satisfied the diagnosis of MDD. Multivariate logistic regression model showed that comorbid generalized anxiety disorder (GAD) and the symptom of "fear of losing control or going crazy" were associated with MDD in patients with panic disorder. In female patients, the "chills or hot flushes" symptom was also associated with comorbid MDD. Conclusion : These results showed that coexisting GAD and certain symptoms of panic are associated with comorbid MDD.

진폐환자 가족의 특성 (The Characteristics of the Families with Pneumoconiosis Patients)

  • 박영미;이성은
    • 한국직업건강간호학회지
    • /
    • 제8권1호
    • /
    • pp.84-91
    • /
    • 1999
  • Pneumoconiosis is a pathological change which is caused by coal dusts. It is a chronic disease that is not cured thoroughly but need treatment and nursing care through all lifetime of the patient. The family of the patient will be suffered from the physical and mental difficulties in the consequence of pneumoconiosis. The study is to find out the characteristics of the families with pneumoconiosis patients. The subjects of the study were 300 families with pneumoconiosis patients who were under medical treatment in Taeback, Donghae, Jeongsun Occupational Medical Center. The period of the study was from the 8th to the 31st of August, 1998. The data were collected by the structured questionnaires included the family intensity measurement which was translated by "Oh". The general properties of the subjects were calculated by frequency and percentage with SAS program. The followings are the summaries of the study. 1) The mean age of the pneumoconiosis patients was 62.3 years. The mean duration of diseases was 11 years and 7 months and the mean duration of hospital stay was 6 years and 4 months. 2) The mean age of the primary care giver was 55.7 years. The proportion of highschool education was 9.6% and it was quite low level compared to other primary care giver groups. 3) The average number of family members were 1.76 person(2.76 persons included patient). The economic status was somewhat high compared to other families with chronic patients. 4) The mean score of family intensity was 41.2(item mean=3.4). With the result, it is recommended to develop a program to improve the quality of family life. For example, there will be social support program for pneumoconiosis patients family sponsored by Social Insurance for Occupational Diseases.

  • PDF

지중케이블 활선검출기를 위한 자장 센서 개발 (Development of Magnetic Sensor for Live Line Detector of the Underground Cable)

  • 김기준;오용철;이경섭;정한석;김탁용;최미희;송민영;신철기;김진사
    • 한국전기전자재료학회논문지
    • /
    • 제24권2호
    • /
    • pp.166-171
    • /
    • 2011
  • We use the electrical energy and it is essential energy in modern life, but we lay cable underground due to the issue for environment and safety. Safety for worker is still insufficient for the development of safety equipment and related research has been focused on the cable lifetime diagnosis at underground cable work. I have to develop live line detector around the magnetic field were investigated at underground cable. In this paper, we were investigated by variation of coil turns and load due to detection of magnetic field at lines around. And detected value of developing products compared with measured value of milli-gauss meter. As a result, the value of the number of coil turns was found to be proportional to the measured value. But turn-numbers increase showed that the weak noise. I could be confirmed that sensor showed the optimum value from 4,000 to 5,0000.

Chemical Stability of Conductive Ceramic Anodes in LiCl-Li2O Molten Salt for Electrolytic Reduction in Pyroprocessing

  • Kim, Sung-Wook;Kang, Hyun Woo;Jeon, Min Ku;Lee, Sang-Kwon;Choi, Eun-Young;Park, Wooshin;Hong, Sun-Seok;Oh, Seung-Chul;Hur, Jin-Mok
    • Nuclear Engineering and Technology
    • /
    • 제48권4호
    • /
    • pp.997-1001
    • /
    • 2016
  • Conductive ceramics are being developed to replace current Pt anodes in the electrolytic reduction of spent oxide fuels in pyroprocessing. While several conductive ceramics have shown promising electrochemical properties in small-scale experiments, their long-term stabilities have not yet been investigated. In this study, the chemical stability of conductive $La_{0.33}Sr_{0.67}MnO_3$ in $LiCl-Li_2O$ molten salt at $650^{\circ}C$ was investigated to examine its feasibility as an anode material. Dissolution of Sr at the anode surface led to structural collapse, thereby indicating that the lifetime of the $La_{0.33}Sr_{0.67}MnO_3$ anode is limited. The dissolution rate of Sr is likely to be influenced by the local environment around Sr in the perovskite framework.

교면 덧씌우기 콘크리트의 인발부착강도(引拔附着强度) 시험법(試驗法) 제안(提案) (Proposal of Concrete Pull Off Bond Strength Measurement Method for Bridge Deck Overlay)

  • 김성환;김동호;김현오;이봉학
    • 산업기술연구
    • /
    • 제23권A호
    • /
    • pp.149-156
    • /
    • 2003
  • The development and maintenance of a sound bond are essential requirements of concrete repair and replacement. The bond property of a overlay to its substrate concrete during the lifetime is one of the most important performance requirements which should be quantified. A standard or a verified bond strength measurement method is required at field for screening, selecting materials and quality control for overlay or repair materials, but no test method has been adopted as a standard. In this study, a concrete pull off bond strength measurement method for field application is proposed and evaluated. This study compares the splitting tensile test, slant shear test, nipple pipe direct tensile test, flexural adhesion test, briquette tensile test, jumbo nail pull-out test and core pull-off test with their test procedures. From these comparison and investigation, core pull-off test is selected as a main topic of this study because of it's suitability for in situ testing, simplicities in field application and clearness at interface boundary condition. Thus, the proposed core pull off test is evaluated to be the most appropriate method for field application in a simple manner. The fracture surface and fracture mode could be easily determined by visual observation of failure surface of the field specimen. The core pull off test was found to be sensitive to surface condition and latex contents at latex modified concrete.

  • PDF

Quenching of Ofloxacin and Flumequine Fluorescence by Divalent Transition Metal Cations

  • Park, Hyoung-Ryun;Oh, Chu-Ha;Lee, Hyeong-Chul;Choi, Jae-Gyu;Jung, Beung-In;Bark, Ki-Min
    • Bulletin of the Korean Chemical Society
    • /
    • 제27권12호
    • /
    • pp.2002-2010
    • /
    • 2006
  • This study examined the quenching of ofloxacin (OFL) and flumequine (FLU) fluorescence by $Cuj^{2+}$, $Ni^{2+}$, $Co^{2+}$ and $Mn^{2+}$ in an aqueous solution. The change in the fluorescence intensity and lifetime was measured at various temperatures as a function of the quencher concentration. According to the Stern-Volmer plots, the fluorescence emission was quenched by both collisions (dynamic quenching) and complex formation (static quenching) with the same quencher but the effect of static quenching was larger than that of dynamic quenching. Large static and dynamic quenching constants for both OFL and FLU support significant ion-dipole and orbital-orbital interactions between fluorophore and quencher. For both molecules, the static and dynamic quenching constants by $Cu^{2+}$ were the largest among all the metal quenchers examined in this study. In addition, both the static and dynamic quenching mechanisms by $Cu^{2+}$ were somewhat different from the quenching caused by other metals. Between $Ni^{2+}$ and FLU, a different form of chemical interaction was observed compared with the interaction by other metals. The change in the absorption spectra as a result of the addition of a quencher provided information on static quenching. With all these metals, the static quenching constant of FLU was larger than those of OFL. The fluorescence of OFL was quite insensitive to both the dynamic and static quenching compared with FLU. This property of OFL can be explained by the twisted intramolecular charge transfer in the excited state.

Blistering Induced Degradation of Thermal Stability Al2O3 Passivation Layer in Crystal Si Solar Cells

  • Li, Meng;Shin, Hong-Sik;Jeong, Kwang-Seok;Oh, Sung-Kwen;Lee, Horyeong;Han, Kyumin;Lee, Ga-Won;Lee, Hi-Deok
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제14권1호
    • /
    • pp.53-60
    • /
    • 2014
  • Different kinds of post-deposition annealing (PDA) by a rapid thermal process (RTP) are used to enhance the field-effect passivation of $Al_2O_3$ film in crystal Si solar cells. To characterize the effects of PDA on $Al_2O_3$ and the interface, metal-insulator semiconductor (MIS) devices were fabricated. The effects of PDA were characterized as functions of RTP temperature from $400{\sim}700^{\circ}C$ and RTP time from 30~120 s. A high temperature PDA can retard the passivation of thin $Al_2O_3$ film in c-Si solar cells. PDA by RTP at $400^{\circ}C$ results in better passivation than a PDA at $400^{\circ}C$ in forming gas ($H_2$ 4% in $N_2$) for 30 minutes. A high thermal budget causes blistering on $Al_2O_3$ film, which degrades its thermal stability and effective lifetime. It is related to the film structure, deposition temperature, thickness of the film, and annealing temperature. RTP shows the possibility of being applied to the PDA of $Al_2O_3$ film. Optimal PDA conditions should be studied for specific $Al_2O_3$ films, considering blistering.