• Title/Summary/Keyword: Numerical Model Simulation

Search Result 4,406, Processing Time 0.028 seconds

Onset of Natural Convection in Transient Hot Wire Device for Measuring Thermal Conductivity of Nanofluids (비정상열선법을 이용한 나노유체 열전도도 측정 시 자연대류 개시점에 대한 연구)

  • Lee, Seung-Hyun;Kim, Hyun-Jin;Jang, Seok-Pil
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.3
    • /
    • pp.279-285
    • /
    • 2011
  • We perform a numerical study to determine the time of onset of natural convection in a transient hot wire (THW) device for measuring the thermal conductivity of nanofluids. The samples used in this simulation are water-based $Al_2O_3$ nanofluids with volume fractions of 1%, 4%, and 10%, and the properties are calculated by theoretical models and experimental correlations. The THW apparatus using coated wire is modeled by the control-volume-based finite difference method, and the start of natural convection is determined by observing the temperature rise of the wire under a gravity field. The onset time is 11.5 s for water and 41.6 s for water-based $Al_2O_3$ nanofluids predicted by Maxwell thermal conductivity model with a 10% volume fraction. We confirm that the onset time of natural convection of nanofluids in the cylinder increases with the nanoparticle volume fraction. We suggest a correlation for predicting the onset time on the basis of the numerical results. Finally, it is shown that the measurement error due to natural convection is negligible if the measurement using the transient hot wire method is completed before the onset of natural convection in the base fluid.

Evaluation of Modified Design Fire Curves for Liquid Pool Fires Using the FDS and CFAST (FDS와 CFAST를 이용한 액체 풀화재의 수정된 디자인 화재곡선 평가 연구)

  • Baek, Bitna;Oh, Chang Bo;Lee, Chi Young
    • Fire Science and Engineering
    • /
    • v.32 no.2
    • /
    • pp.7-16
    • /
    • 2018
  • In this study, the previous design fire curve for fire simulation was modified and re-suggested. Numerical simulations with the FDS and CFAST were performed for the n-heptane and n-octane pool fires in the ISO 9705 compartment to evaluate the prediction performances of the previous 1-stage and modified 2-stage design fire curves. The numerical results were compared with the experimental temperature and concentrations of $O_2$ and $CO_2$. The FDS and CFAST simulations with the 2-stage design fire curve showed better prediction performance for the variation of temperature and major species concentration than the simulations with 1-stage design fire curve. Especially, the simulations with the 2-stage design fire curve agreed with the experimental temperature more reasonably than the results with the 1-stage design fire curve. The FDS and CFAST simulations showed good prediction performance for the temperature in the upper layer of compartment and the results with the FDS and CFAST were similar to each other. However, the FDS and CFAST showed poor and different prediction performance for the temperature in the lower layer of compartment.

Rotordynamic Analysis of a Dual-Spool Turbofan Engine with Focus on Blade Defect Events (블레이드 손상에 따른 이축식 터보팬 엔진의 동적 안정성 해석)

  • Kim, Sitae;Jung, Kihyun;Lee, Junho;Park, Kihyun;Yang, Kwangjin
    • Tribology and Lubricants
    • /
    • v.36 no.2
    • /
    • pp.105-115
    • /
    • 2020
  • This paper presents a numerical study on the rotordynamic analysis of a dual-spool turbofan engine in the context of blade defect events. The blades of an axial-type aeroengine are typically well aligned during the compressor and turbine stages. However, they are sometimes exposed to damage, partially or entirely, for several operational reasons, such as cracks due to foreign objects, burns from the combustion gas, and corrosion due to oxygen in the air. Herein, we designed a dual-spool rotor using the commercial 3D modeling software CATIA to simulate blade defects in the turbofan engine. We utilized the rotordynamic parameters to create two finite element Euler-Bernoulli beam models connected by means of an inter-rotor bearing. We then applied the unbalanced forces induced by the mass eccentricities of the blades to the following selected scenarios: 1) fully balanced, 2) crack in the low-pressure compressor (LPC) and high pressure compressor (HPC), 3) burn on the high-pressure turbine (HPT) and low pressure compressor, 4) corrosion of the LPC, and 5) corrosion of the HPC. Additionally, we obtained the transient and steady-state responses of the overall rotor nodes using the Runge-Kutta numerical integration method, and employed model reduction techniques such as component mode synthesis to enhance the computational efficiency of the process. The simulation results indicate that the high-vibration status of the rotor commences beyond 10,000 rpm, which is identified as the first critical speed of the lower speed rotor. Moreover, we monitored the unbalanced stages near the inter-rotor bearing, which prominently influences the overall rotordynamic status, and the corrosion of the HPC to prevent further instability. The high-speed range operation (>13,000 rpm) coupled with HPC/HPT blade defects possibly presents a rotor-case contact problem that can lead to catastrophic failure.

Development and Verification of OGSFLAC Simulator for Hydromechanical Coupled Analysis: Single-phase Fluid Flow Analysis (수리-역학적 복합거동 해석을 위한 OGSFLAC 시뮬레이터 개발 및 검증: 단상 유체 거동 해석)

  • Park, Chan-Hee;Kim, Taehyun;Park, Eui-Seob;Jung, Yong-Bok;Bang, Eun-Seok
    • Tunnel and Underground Space
    • /
    • v.29 no.6
    • /
    • pp.468-479
    • /
    • 2019
  • It is essential to comprehend coupled hydro-mechanical behavior to utilize subsurface for the recent demand for underground space usage. In this study, we developed a new simulator for numerical simulation as a tool for researching to consider the various domestic field and subsurface conditions. To develop the new module, we combined OpenGeoSys, one of the scientific software package that handles fluid mechanics (H), thermodynamics (T), and rock and soil mechanics (M) in the subsurface with FLAC3D, one of the commercial software for geotechnical engineering problems reinforced. In this simulator development, we design OpenGeoSys as a master and FLAC3D as a slave via a file-based sequential coupling. We have chosen Terzaghi's consolidation problem related to single-phase fluid flow at a saturated condition as a benchmark model to verify the proposed module. The comparative results between the analytical solution and numerical analysis showed a good agreement.

A Study on the Structural Behavior of an Underground Radwaste Repository within a Granitic Rock Mass with a Fault Passing through the Cavern Roof (화장암반내 단층지역에 위치한 지하 방사성폐기물 처분장 구조거동연구)

  • 김진웅;강철형;배대석
    • Tunnel and Underground Space
    • /
    • v.11 no.3
    • /
    • pp.257-269
    • /
    • 2001
  • Numerical simulation is performed to understand the structural behavior of an underground radwaste repository, assumed to be located at the depth of 500 m, in a granitic rock mats, in which a fault intersects the roof of the repository cavern. Two dimensional universal distinct element code, UDEC is used in the analysis. The numerical model includes a granitic rock mass, a canister with PWR spent fuels surrounded by the compacted bentonite inside the deposition hole, and the mixed bentonite backfilled in the rest of the space within the repository cavern. The structural behavior of three different cases, each case with a fault of an angle of $33^{\circ},\;45^{\circ},\;and\;58^{\circ}$ passing through the cavern roof-wall intersection, has been compared. And then fro the case with the $45^{\circ}$ fault, the hydro-mechanical, thermo-mechanical, and thermo-hydro-mechanical interaction behavior have been studied. The effect of the time-dependent decaying heat, from the radioactive materials in PWR spent fuels, on the repository and its surroundings has been studied. The groundwater table is assumed to be located 10m below the ground surface, and a steady state flow algorithm is used.

  • PDF

Numerical Simulation for Estimating Fish Shelter at the Downstream of Gumi Weir (수리구조물 하류에서 어류의 피난처 해석을 위한 수치모의 (구미보를 중심으로))

  • Cho, Hyoung Jin;Jang, Chang-Lae
    • Ecology and Resilient Infrastructure
    • /
    • v.1 no.1
    • /
    • pp.8-18
    • /
    • 2014
  • This study analyzes characteristics of flow using 3 dimensional numerical model, Delft3D, at the downstream of hydraulic structure. And fish shelters are suggested by analyzing them in flood time. A hydraulic structure changes flow conveyance, water depth and velocity affecting the activity of the fish. Flow depth decreases and velocity is fast near the left bank at the downstream of Gumi weir because of the concentration of flow due to it. Therefore, fish shelters are generated near the right bank of it. As a result of vertical velocity distribution which indicates the range of fish activity, maximum value are 0.0043 m/s in 30-year of return period of flood 0.0052 m/s in 50 year flood, 0.0046 m/s in 80-year of return period of flood, and 0.0039 m/s in 100-year of return period of flood. As the discharge increases, the areas of fish shelters decreases because depth and turbulent energy increase according to increases discharge. The estimated areas of fish shelters near the right bank decrease from 61.5% in 30-year of return period of flood to 39.0% 100-year of return period of flood. Therefore, the constructed hydraulic structures affect fish shelters.

Numerical Study on the Evaporation Characteristics of Biocrude-oil Produced by Fast Pyrolysis (급속열분해를 통하여 생산된 바이오오일 액적의 증발 특성에 관한 수치해석적 연구)

  • Choi, Sang Kyu;Choi, Yeon Seok;Kim, Seock Joon;Han, So Young
    • Applied Chemistry for Engineering
    • /
    • v.27 no.6
    • /
    • pp.646-652
    • /
    • 2016
  • Biomass is regarded as one of the promising energy sources to deal with the depletion of fossil fuels and the global warming issue. Biocrude-oil can be produced through the fast pyrolysis of biomass feedstocks such as wood, crops, agricultural and forestry residues. It has significantly higher viscosity than that of conventional petroleum fuel and contains solid residues, which can lower the spray and atomization characteristics when applied to the burner. In addition, biocrude-oil consists of hundreds of chemical species derived from cellulose, hemicellulose and lignin, and evaporation characteristics of the biocrude-oil droplet are distinct from the conventional fuels. In the present study, a numerical study was performed to investigate the evaporation characteristics of biocrude-oil droplet using a simplified composition of the model biocrude-oil which consists of acetic acid, levoglucosan, phenol, and water. The evaporation characteristics of droplets were compared at various surrounding air temperatures, initial droplet diameters, and ethanol mixing ratios. The evaporation time becomes shorter with increasing air temperature, and it is much sensitive to the air temperature particularly in low temperature ranges. It was also found that the biocrude-oil droplet evaporates faster in cases of the smaller initial droplet diameter and larger ethanol mixing ratio.

A Study on the Controlled-source Electromagnetic Responses Incorporating the Steel Casing (시추공 케이싱을 고려한 인공송신원 전자탐사 반응 고찰)

  • Oh, Seokmin;Noh, Kyubo;Seol, Soon Jee;Byun, Joongmoo
    • Geophysics and Geophysical Exploration
    • /
    • v.20 no.4
    • /
    • pp.216-225
    • /
    • 2017
  • Recently, steel casing became an interesting issue when applying controlled-source electromagnetic (EM) method to various fields because effects of steel casing on EM responses are not negligible. This study employed an approach that approximates the steel casing as a series of electric dipole sources in order to develop the numerical algorithm for the efficient simulation of EM responses in the presence of steel casing. After verifying the validity of the developed algorithm, we analyze effects of steel casing on EM responses with the synthetic model simulating geothermal reservoir environment. The analysis showed that the effects of steel casing on EM responses are localized near the casing and increase as the transmitter becomes close to the casing. In addition, through the analysis on the EM responses by the injection of clean water, we confirm that the effects of casing are negligible when interpreting the after-injection data acquired using the transmitter located far enough from the casing. Considering the difference in EM responses between before and after injection in inversion, the effects of the casing can be neglected although after-injection data shows considerable difference due to the close distance between the transmitter and casing. To investigate this kind steel casing effect, the precise analysis on EM responses should be preceded. The algorithm introduced in this study will contribute to the reliable calculations of EM responses distorted by the conductive steel casing.

LRB-based hybrid base isolation systems for cable-stayed bridges (사장교를 위한 LRB-기반 복합 기초격리 시스템)

  • Jung, Hyung-Jo;Park, Kyu-Sik;Spencer, Billie-F.Jr.;Lee, In-Won
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.8 no.3
    • /
    • pp.63-76
    • /
    • 2004
  • This paper presents LRB-based hybrid base isolation systems employing additional active/semiactive control devices for mitigating earthquake-induced vibration of a cable-stayed 29 bridge. Hybrid base isolation systems could improve the control performance compared with the passive type-base isolation system such as LRB-installed bridge system due to multiple control devices are operating. In this paper, the additional response reduction by the two typical additional control devices, such as active type hydraulic actuators controlled by LQG algorithm and semiactive-type magnetorheological dampers controlled by clipped-optimal algorithm, have been evaluated bypreliminarily investigating the slightly modified version of the ASCE phase I benchmark cable-stayed bridge problem (i.e., the installation of LRBs to the nominal cable-stayed bridge model of the problem). It shows from the numerical simulation results that all the LRB based hybrid seismic isolation systems considered are quite effective to mitigate the structural responses. In addition, the numerical results demonstrate that the LRB based hybrid seismic isolation systems employing MR dampers have the robustness to some degree of the stiffness uncertainty of in the structure, whereas the hybrid system employing hydraulic actuators does not. Therefore, the feasibility of the hybrid base isolation systems employing semiactive additional control devices could be more appropriate in realfor full-scale civil infrastructure applications is clearly verified due to their efficacy and robustness.

A Study on Innovation and Competitive Strategy in Network-Based Economy: Case Analysis on Network Effects, Incremental Innovation in Korean Mobile Telecommunication Industry (네트워크 경제 하에서 혁신과 경쟁 전략에 대한 기반 연구: 한국 이동통신 산업 사례를 중심으로)

  • An, Kwang-Jun;Shin, Dong-Hyung
    • Journal of Korea Technology Innovation Society
    • /
    • v.11 no.2
    • /
    • pp.145-170
    • /
    • 2008
  • The existence of network is indeed the single most important factor that brings about new business phenomena in the new digital economy, especially in the IT industry. Network effect refers to a phenomenon that the increase in size of the network leads to increased network value and user utility. It determines the competitive structure of an industry and the performances of industry competitors (Shapiro and Varian, 1999). The phenomenon of increasing returns and winner-take-all enjoyed by the early winner in the competition can be attributed to the existence of positive feedback which increases the value of network and induces more users into join the network (Arthur, 1996; Shapiro and Varian, 1999; Song and Lee, 2003). This research attempts to shed light on the topic of innovation and competitive strategy of network-based industries. We analyze the case of the Korean mobile communications industry, in which a shift in technological paradigm from 2G to 3G brought new changes to the competitive structure of the industry. The Korean mobile communications industry makes an ideal case for analysis since it is an industry whose value is inherently dependent upon its user network. It is characterized by the typical increasing returns, in which a monopolizing player is enjoying firstmover's network effects. Because of the existence of network in the mobile communications industry, latecomers' disruptive innovations could not outcompete the incumbent's sustaining innovations. The contribution of this research lies in laying a groundwork for future studies by introducing a numerical simulation model to analyze the complexity theory and network effect.

  • PDF