• 제목/요약/키워드: Numerical Experiment

검색결과 2,467건 처리시간 0.036초

Parametric Study on Oscillating Water Column Wave Energy Converter Applicable to Breakwater

  • Park, Sewan;Nam, Bo Woo;Kim, Kyong-Hwan;Hong, Keyyong
    • Journal of Advanced Research in Ocean Engineering
    • /
    • 제4권2호
    • /
    • pp.66-77
    • /
    • 2018
  • This paper presents a parametric study on an oscillating water column (OWC) wave energy converter (WEC). This OWC has been planned for installation in the breakwaters on isolated islands located away from the mainland. Both a numerical analysis and a model experiment are utilized for determining a proper conceptual design for this purpose. Various design parameters, including the configurations and dimensions, are evaluated through the numerical analysis, which is based on a potential flow theory, and several design concepts are then selected as candidates. The model experiment using a 2D wave flume is conducted to evaluate the effects of the design parameters and compare the performances of the candidates. Based on the overall results of the numerical analysis and model experiment, a conceptual design of the OWC WEC applicable to a breakwater is selected.

하천 만곡률과 홍수량에 따른 수면경사도 산정 (Estimation of the Water Surface Slope by the Flood Discharge with River Bend Curvature)

  • 최한규;이문희;백효선
    • 산업기술연구
    • /
    • 제26권A호
    • /
    • pp.129-137
    • /
    • 2006
  • In this research, we made a one and two-dimensional analysis of numerical data collected from the bend curvature of a bended river section. According to the result from the numerical analysis, the inflow & output angle caused a water level deviation which increased with an increase of the flood discharge. From the water level deviation of our two-dimensional numerical model, we obtained the maximum slope of 6,67% when the inflow and output angle was 105 degrees and the flood discharge was 500 CMS. As for the right side, the differences with the one-dimensional numerical model were reduced when the angle was more than $90^{\circ}$. As for the left side the differences were reduced when the angle was more than $105^{\circ}$. For a river with more than 90 degrees bend curvature, a hydraulic experiment would be more appropriate than a numerical analysis.

  • PDF

An Experiment of Internal Waves Observation by Synthetic Aperture Radar

  • Junmin, Meng;Jie, Zhang
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2003년도 Proceedings of ACRS 2003 ISRS
    • /
    • pp.1343-1345
    • /
    • 2003
  • An internal wave observation experiment by SAR in South China Sea is described. Two scenes of Radarsat ScanSAR images were acquired. Internal solitary waves are found in all the two images. It is concluded that these internal waves are generated in Bashi channel. Relationship between internal wave generation and tide is studied based on analyzing of tidal data of Legaspi in Philippine. Using ocean environmental data of this sea area internal waves’ amplitude and wave speed are detected by SAR images.

  • PDF

도로 포장 기술 개선에 따른 대기 경계층의 열 변화에 관한 연구 (A Study on the Impact of an Improved Road Pavement Technology on the Thermal Structure of Atmospheric Boundary Layer)

  • 이순환;김인수;김해동
    • 한국대기환경학회지
    • /
    • 제24권5호
    • /
    • pp.551-561
    • /
    • 2008
  • In order to clarify the impact of anti-heat insulation pavement on the thermal structure of atmospheric boundary layer, field experiments and numerical simulations were carried out. Field experiment with various pavements were also conducted for 24 hours from 09LST 19 June 2007. And numerical experiment mainly focused on the impact of albedo variation, which is strongly associated with thermal characteristics of insulated pavement materials, on the temporal variation of planterly boundary layer. Numerical model used in this study is one dimension model with Planterly Boundary Layer developed by Oregon State University (OSUPBL). Because anti-heat insulation pavement material shows higher albedo value, not only maximum surface temperature but also maximum surface air temperature on anti-heat insulation pavement is lower than that on asphalt. The maximum value of surface temperature only reach on $49.5^{\circ}C$. As results of numerical simulations, surface sensible heat flux and the height of mixing layer are also influenced by the values of albedo. Therefore the characteristics of urban surface material and its impact on atmosphere should be clarified before the urban planning including improvement of urban heat environment and air quality.

다면체 사석배열 해안구조물에 대한 수치해석모델의 모델링 기법 검증 (Validating Numerical Analysis Model Modeling Method by Polyhedral Rubble Mound Structure Arrays)

  • 최웅식;김기동;한동석
    • 대한토목학회논문집
    • /
    • 제34권3호
    • /
    • pp.723-728
    • /
    • 2014
  • 세굴방지를 위하여 설치하는 해안구조물의 쇄파효과를 검증하기 위하여 수리조파실험이 실시된다. 하지만 수리조파실험을 실시하기 위해서 사용되는 실험 장치와 해안구조물의 제작에 많은 비용과 시간이 소요된다. 수치해석모델과 수리조파실험의 해석결과를 비교하여 검증하면, 수치모델을 활용하여 쇄파효과를 예측할 수 있고 실험 장치와 해안구조물 제작에 소요되는 비용과 시간을 절약할 수 있다. 본 연구에서는 다면체 사석 구조물을 대상으로 수치해석결과와 수리조파실험 결과의 처오름 및 처내림 높이 비교분석을 수행하였고 해석적 모의 조파실험 모델링 기법을 검증하였다. 또한, 사용한 수치해석 접근 방법을 활용하여 사석의 부피비와 마찰면적을 변화시켜 쇄파효과를 예측하였다.

3차원 수치모형실험을 통한 오탁방지막의 오염물질 및 준설토 확산 저감특성 조사 (Investigation of Reducing Characteristics for the Spreading of Dredging Soil and the Diffusion of Contaminant by Silt Protector Curtain through Three Dimensional Numerical Model Experiment)

  • 홍남식
    • 한국해양공학회지
    • /
    • 제24권4호
    • /
    • pp.78-85
    • /
    • 2010
  • This study investigates reducing characteristics for the spreading of dredged soil and the diffusion of contaminant by silt protector curtain through three dimensional numerical experiment. The numerical medel is modified by combining the sediment transport characteristics for cohesive sediment into the previously developed model. Several numerical experiments have been given in order to investigate the reducing effect of silt protector using two dimensional numerical channel model under various parameters such as upstream flow velocity, depth of silt curtain and the position of dumped materials. Through the evaluation of several simulation results, we knew that the careful design has to be given in the determination of depth and position of silt protector.

RI를 이용한 하천 현장실험 및 수치 모델링 (A Field Tracer Experiment by using RI and Numerical Modelling in River)

  • 김기철;천일용;정성희;이정렬;서경석
    • 방사선산업학회지
    • /
    • 제2권3호
    • /
    • pp.135-140
    • /
    • 2008
  • A field tracer experiment using radioisotope was carried out to investigate the characteristics of a pollutant transport and a determination of the dispersion coefficients in a river system. The dispersion coefficients in the longitudinal and transverse directions were determined by using the measured concentration of a radioisotope. The two-dimensional numerical models were applied to calculate the flow and concentration fields at the experimental site. Several numerical simulations were performed to investigate the effects of the numerical results according to variations of the dispersion coefficients. The calculated concentrations agreed well with the measured ones.

수치적 실험에 의한 위성 내부 유동체의 안정-불안정 영역 판별 (DETERMINATION OF GLOBAL STABILITY OF THE SLOSH MOTION IN A SPACECRAFT VIA NUMERICAL EXPERIMENT)

  • 강자영
    • Journal of Astronomy and Space Sciences
    • /
    • 제20권4호
    • /
    • pp.351-358
    • /
    • 2003
  • 회전안정화 로켓 모터를 이용하는 우주 비행체의 자세 불안정 현상을 수치적 실험을 통하여 연구하였다. 이전 연구에서는 해석적 방법을 통하여 주어진 우주 비행체에 대한 정상해를 구하고 실제 발생했던 공진과 유사한 공진조건을 찾았으나 정상해 근방에서의 안정도 또는 파라미터 공간 전역에서의 안정도가 어떻게 변하는 지를 알 수가 없었다. 따라서, 본 연구에서는 이전 연구결과를 기초로 하여 주어진 파라미터 공간 전역에서 수치적 실험을 통하여 유동체의 파라미터 값에 따라 위성체의 자세 안정도가 어떻게 변화하는지를 관찰하고, 시스템 설계에 필요한 파라미터들의 안정/불안정 영역을 결정하였다.

원형휜-원형관 열교환기의 휜효율 이론에 관한 수치적 검증 (VERIFICATION OF FIN EFFICIENCY THEORY FOR THE CIRCULAR FINNED-TUBE HEAT EXCHANGER BY NUMERICAL EXPERIMENT)

  • 강희찬;임복빈;이종휘;장병춘;안서욱
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 학술대회
    • /
    • pp.137-142
    • /
    • 2008
  • The purpose of the present study is to investigate the convective heat transfer characteristics and the validity of fin efficiency of the circular finned-tube heat exchanger by using commercial CFD code. The heat transfer coefficient obtained by using the laminar model was 22% overestimated to the experimental data. The fin surface temperature compared with the experimental data measured by the liquid crystal method. The fin efficiency by the present numerical experiment, defined as normalized and averaged fin surface temperature, was greater than the theoretical fin efficiency and the difference is increased at high value of the factor m.

  • PDF

음향라디오시티법을 이용한 잔향수조 음장 해석과 실험검증 (Acoustic Field Analysis of Reverberant Water Tank using Acoustic Radiosity Method and Experimental Verification)

  • 김국현
    • 대한조선학회논문집
    • /
    • 제56권5호
    • /
    • pp.464-471
    • /
    • 2019
  • The acoustic power is a major acoustical characteristic of an underwater vehicle and could be measured in a reverberant water tank. In order to obtain accurate measurement results, the acoustic field formed by the sound source should be investigated quantitatively in the reverberant water tank. In this research, the acoustic field of a reverberant water tank containing an underwater sound source has been analyzed by using an acoustic radiosity method one of the numerical analysis methods suitable for the acoustic analysis of the highly diffused space. The source level of the underwater sound source and acoustical properties of the water tank input to the numerical analysis have been estimated by applying the reverberant tank plot method through a preliminary experiment result. The comparison of the numerical analysis result with that of the experiment has verified the accuracy of the acoustic radiosity method.