• Title/Summary/Keyword: Number of tests

Search Result 2,803, Processing Time 0.027 seconds

Experimental investigation of the aeroelastic behavior of a complex prismatic element

  • Nguyen, Cung Huy;Freda, Andrea;Solari, Giovanni;Tubino, Federica
    • Wind and Structures
    • /
    • v.20 no.5
    • /
    • pp.683-699
    • /
    • 2015
  • Lighting poles and antenna masts are typically high, slender and light structures. Moreover, they are often characterized by distributed eccentricities that make very complex their shape. Experience teaches that this structural type frequently suffers severe damage and even collapses due to wind actions. To understand and interpret the aerodynamic and aeroelastic behavior of lighting poles and antenna masts, this paper presents the results of static and aeroelastic wind tunnel tests carried out on a complex prismatic element representing a segment of the shaft of such structures. Static tests are aimed at determining the aerodynamic coefficients and the Strouhal number of the test element cross-section; the former are used to evaluate the critical conditions for galloping occurrence based on quasi-steady theory; the latter provides the critical conditions for vortex-induced vibrations. Aeroelastic tests are aimed at reproducing the real behavior of the test element and at verifying the validity and reliability of quasi-steady theory. The galloping hysteresis phenomenon is identified through aeroelastic experiments conducted on increasing and decreasing the mean wind velocity.

Experimental behaviour of composite beams subjected to a hogging moment

  • Pecce, Marisa;Rossi, Fernando;Bibbo, Fabio Antonio;Ceroni, Francesca
    • Steel and Composite Structures
    • /
    • v.12 no.5
    • /
    • pp.395-412
    • /
    • 2012
  • The present work addresses the rotational capacity of steel-concrete composite beams, which is a key issue for the seismic design of composite frames. Several experimental tests from the literature are summarised, and the effects of various parameters on the available plastic rotation are discussed. Furthermore, a number of remarks are made regarding the need for supplementary experimental results. The authors carried out experimental tests on four composite beams in which the type, width and connection degree of the slab were varied. During the tests, the deflection and strains in the steel profiles and bars were measured and recorded, wherein the observed trends in the measured parameters indicated that the failure mode of the beam was influenced by global and local buckling. A comparison of the experimental results to the theoretical ultimate strengths and moment-curvature relationships confirms that buckling phenomena occurred after section yielding, even if a consistent plastic rotation developed. This rotational capacity is well evaluated by a formulation that is available in the literature.

Development of a Web-Based Soil Laboratory (인터넷을 이용한 가상 토질 실험실)

  • Lee, Kyu-Hwan;Lee, Song;Jung, Dae-Suk
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.03a
    • /
    • pp.445-452
    • /
    • 2002
  • In the field of civil and geotechnical engineering, students conduct a variety of soil tests to fulfill undergraduate soil mechanics course requirement. There is a range of problems in soil laboratory instruction, such as, some students not getting hands on experience of conducting tests because of inadequate number of apparatus, time constraints and inability in exciting students to seriously conduit the experiments, However when these laboratory soil tests are simulated with multimedia interaction ann visualization techniques, the students conceptual understanding of soil mechanics is enhanced. The simulation program for website teaching is a computer based instructional package intended to complement, and potentially replace, some physical testing in a real soil laboratory. The overall aim of this project is to develop an experimental simulation program toward active learning and development of critical thinking skills, including data interpretation, understanding of the precesses and influential factors, and problem solving. Therefore enable students to access website to team experimental procedure at any time or place.

  • PDF

Test of Headed Reinforcement in Pullout

  • Park, Dong-Uk;Hong, Sung-Gul;Lee, Chin-Yong
    • KCI Concrete Journal
    • /
    • v.14 no.3
    • /
    • pp.102-110
    • /
    • 2002
  • Results of an experimental study on the pullout behavior of the headed reinforcement are presented. A total of 48 pullout tests was performed to evaluate pullout strengths and load-displacement behaviors in pullout of the headed bars. The square steel heads had gross area of 4 $A_{b}$ and thickness of $d_{b}$ The test program consisted of three pullout test groups: Simple and Edge pullout tests using plain concrete slabs, comparison of pullout performances between the standard hooks and the headed reinforcement, and pullout tests of headed reinforcement using reinforced concrete columns. Test variables included concrete strengths ( $f_{c}$' = 27.1MPa, 39.1MPa), reinforcing bar diameters (D16~D29), embedment depths (6 $d_{b}$~12 $d_{b}$), edge conditions, column reinforcement, and single-vs.-multiple bar pullout. Test results revealed that the heads effectively provided the pullout resistances of the deformed bars in tension. The load-displacement behaviors were similar between the 90-degree hooks and the headed reinforcement. When a multiple number of headed bars installed with small head-to-head spacings was pulled out, reinforcement designed to run across the concrete failure surface in a direction parallel to the headed bars helped improve the pullout performances of the headed reinforcement.t.ement.t.

  • PDF

Snap back testing of unbonded post-tensioned concrete wall systems

  • Twigden, Kimberley M.;Henry, Richard S.
    • Earthquakes and Structures
    • /
    • v.16 no.2
    • /
    • pp.209-219
    • /
    • 2019
  • Unbonded Post-Tensioned (UPT) precast concrete systems have been shown to provide excellent seismic resistance. In order to improve understanding of the dynamic response of UPT systems, a series of snap back tests on four UPT systems was undertaken consisting of one Single Rocking Wall (SRW) and three Precast Wall with End Columns (PreWEC) systems. The snap back tests provided both a static pushover and a nonlinear free vibration response of a system. As expected the SRW exhibited an approximate bi-linear inertia force-drift response during the free vibration decay and the PreWEC walls showed an inertia force-drift response with increased strength and energy dissipation due to the addition of steel O-connectors. All walls exhibited negligible residual drifts regardless of the number of O-connectors or the post-tensioning force. When PreWEC systems of the same strength were compared the inclusion of further energy dissipating O-connectors was found to decrease the measured peak wall acceleration. Both the local and global wall parameters measured at pseudo-static and dynamic loading rates showed similar behaviour, which demonstrates that the dynamic behaviour of UPT walls is well represented by pseudo-static tests. The SRW was found to have Equivalent Viscous Damping (EVD) between 0.9-3.8% and the three PreWEC walls were found to have maximum EVD of between 14.7-25.8%.

EXPERIMENTAL ANALYSIS OF DRIVING PATTERNS AND FUEL ECONOMY FOR PASSENGER CARS IN SEOUL

  • Sa, J.-S.;Chung, N.-H.;Sunwoo, M.-H.
    • International Journal of Automotive Technology
    • /
    • v.4 no.2
    • /
    • pp.101-108
    • /
    • 2003
  • There are a lot of factors that influence automotive fuel economy such as average trip time per kilometer, average trip speed, the number of times of vehicle stationary, and so forth. These factors depend on road conditions and traffic environment. In this study, various driving data were measured and recorded during road tests in Seoul. The accumulated road test mileage is around 1,300 kilometers. The objective of the study is to identify the driving patterns of the Seoul metropolitan area and to analyze the fuel economy based on these driving patterns. The driving data which was acquired through road tests was analysed statistically in order to obtain the driving characteristics via modal analysis, speed analysis, and speed-acceleration analysis. Moreover, the driving data was analyzed by multivariate statistical techniques including correlation analysis, principal component analysis, and multiple linear regression analysis in order to obtain the relationships between influencing factors on fuel economy. The analyzed results show that the average speed is around 29.2 km/h, and the average fuel economy is 10.23 km/L. The vehicle speed of the Seoul metropolitan area is slower, and the stop-and-go operation is more frequent than FTP-75 test mode which is used for emission and fuel economy tests. The average trip time per kilometer is one of the most important factors in fuel consumption, and the increase of the average speed is desirable for reducing emissions and fuel consumption.

Fatigue Properties of Copper Foil and the Evolution of Surface Roughness

  • Oh, Chung-Seog;Bae, Jong-Sung;Lee, Hak-Joo
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.9 no.4
    • /
    • pp.57-62
    • /
    • 2008
  • The aim of this investigation was to extract the fatigue properties at the designated fatigue life of copper foil and observe the mean stress and stress amplitude effects on both the fatigue life and the corresponding surface morphology. Tensile tests were performed to determine the baseline monotonic material properties of the proportional limit and ultimate tensile strength. Constant amplitude fatigue tests were carried out using a feedback-controlled fatigue testing machine. The mean stress and the stress amplitude were changed to obtain the complete nominal stress-life curves. An atomic force microscope was utilized to observe the relationship between the fatigue damage and the corresponding changes in surface morphology. A Basquin's exponent of-0.071 was obtained through the fatigue tests. An endurance limit of 122 MPa was inferred from a Haigh diagram. The specimen surface became rougher as the number of fatigue cycles increased, and there was a close relationship between the fatigue damage and the surface roughness evolution.

Plastic Deformation Capacity of Steel Beam-to-Column Connection under Long-duration Earthquake

  • Yamada, Satoshi;Jiao, Yu;Narihara, Hiroyuki;Yasuda, Satoshi;Hasegawa, Takashi
    • International Journal of High-Rise Buildings
    • /
    • v.3 no.3
    • /
    • pp.231-241
    • /
    • 2014
  • Ductile fracture is one of the most common failure modes of steel beam-to-column connections in moment resisting frames. Most proposed evaluation methods of the plastic deformation capacity of a beam until ductile fracture are based on steel beam tests, where the material's yield strength/ratio, the beam's moment gradient, and loading history are the most important parameters. It is impossible and unpractical to cover all these parameters in real tests. Therefore, a new attempt to evaluate a beam's plastic deformation capacity through analysis is introduced in this paper. Another important issue is about the loading histories. Recent years, the effect on the structural component under long-duration ground motion has drawn great attentions. Steel beams tends to experience a large number of loading cycles with small amplitudes during long-duration earthquakes. However, current research often focuses on the beam's behavior under standard incremental loading protocols recommended by respective countries. In this paper, the plastic deformation capacity of steel beams subjected to long duration ground motions was evaluated through analytical methodology.

Study on the size selectivity of a gillnet for Pacific herring (Clupea pallasii) in the eastern sea of Korea (동해안 청어 (Clupea pallasii) 자망의 망목선택성에 관한 연구)

  • An, Heui-Chun;Bae, Jae-Hyun;Kim, Seonghun
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.49 no.4
    • /
    • pp.360-367
    • /
    • 2013
  • The mesh selectivity of the gillnet for Pacific herring (Clupea pallasii) was examined in field experiments with four different mesh sizes (63, 69, 75 and 81mm) from June to July, 2013 in the coastal areas of Imwon in Gangwon province. The fishing performance tests were conducted with a commercial Pacific herring gillnet and a biodegradable gillnet for Pacific herring together selectivity tests. The filed tests were carried out the total 11 times. The master curve of selectivity was estimated by the extended Kitahara's method. In the results, the catch number of Pacific herring was 9,409 (2,203kg) and occupied 84.2% in total catches weight. The optimal mesh size for 50% retention on first maturity size (female, 250mm) of Pacific herring was estimated as 64.5mm by master selectivity curves. The fishing performance of the biodegradable gillnet was showed to be equivalent with commercial gill for Pacific herring.

A Study on the ballistic impact resistance and dynamic failure behavior of aramid FRMLs by high velocity impact (고속충격에 의한 아라미드 섬유강화 금속적층재의 방탄성능 및 동적파손거동에 관한 연구)

  • 손세원;이두성;김동훈;홍성희
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.527-532
    • /
    • 2000
  • The armor composite material targets such as aramid FRMLs with different type and ply number of face material and different type of back-up material, were studied to determine ballistic impact resistance and dynamic failure behavior during ballistic impact. Ballistic impact resistance is determined by $\textrm{V}_{50}$ ballistic limit, a statical velocity with 50% probability for complete penetration, test method. Also dynamic failure behaviors are respectfully observed that result from $\textrm{V}_{50}$ tests. $\textrm{V}_{50}$ tests with $0^{\circ}$ obliquity at room temperature were conducted with projectiles that were able to achieve near or complete penetration during high velocity impact tests. As a result, ballistic impact resistance of anodized Al 5052-H34 alloy(2 ply) is better than that of anodized Al 5052-H34 alloy(1 ply), but Titanium alloy showed the similar ballistic impact resistance. In the face material, ballistic impact resistance of titanium alloy is better than that of anodized Al 5052-H34 alloy. In the back-up material, ballistic impact resistance of T750 type aramid fiber is better than that of CT709 type aramid fiber.

  • PDF