• 제목/요약/키워드: Number of scanning cycle

검색결과 21건 처리시간 0.03초

공초점 현미경을 이용한 마이크로믹서 내부의 3차원 이미지화 (3-D Imaging in a Chaotic Micromixer Using Confocal Laser Scanning Microscopy (CLSM))

  • 김현동;김경천
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2006년도 추계학술대회 논문집
    • /
    • pp.96-101
    • /
    • 2006
  • 3-D visualization using confocal laser scanning microscopy (CLSM) in a chaotic micromixer was performed as a reproduction experiment and the feasibility of 3-0 imaging technique in the microscale was confirmed. For diagonal micromixer (DM) and two types of staggered herringbone micromixers (SHM) designed by Whitesides et al., to verify the evolution of mixing, cross sectional images are reconstructed at the end of every cycle. In a DM, clockwise rotational flow motion generated by diagonal ridges placed on the floor of micromixer is observed and this motion makes the fluid commingle. On the contrary, there are two rotational flow structures in the SHM and the centers of rotation exchange their position each other every half cycle because of the V shape of ridges varying their orientation every half cycle. Local rotational flow and local extensional flow generated by the complicate ridge pattern make the flow be chaotic and accelerate the mixing of fluid. The dominant parameter that influences on the mixing characteristic of SHM is not the length of micromixer but the number of ridges under the same flow configurations.

  • PDF

리플로우 횟수에 따른 플립칩 접합부의 기계적 특성 평가 (The Effects of the reflow number in the Mechanical Reliability of Flip Chip Solder Joint)

  • 박진석;양경천;한성원;신영의
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2007년 추계학술발표대회 개요집
    • /
    • pp.254-256
    • /
    • 2007
  • In this paper, the effects of the reflow number in the mechanical reliability of flip chip solder joint was investigated by flip chip shear test and thermal shock test. For evaluation mechanical reliability of flip chip, We experiment that specimens were operated 3-times, 6-times, 9-times, 12-times under reflow Process. After shear test and thermal shock test, We measured max shear strength and coming first crack number of thermal cycle. And We observe fracture surface and cross section by using SEM(Scanning Electron Microscope) and optical scope. In the results, the more specimens were operated reflow process, the more decreased maximum shear strength and number of thermal cycle.

  • PDF

Thermal cycle하에서의 OSP 표면 처리된 BGA 패키지의 신뢰성 연구 (Reliability of BGA Package with OSP Surface Finish under Thermal Cycle)

  • 이종범;노보인;이영호;정승부
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2006년도 춘계 학술대회 개요집
    • /
    • pp.206-208
    • /
    • 2006
  • The reliability of BGA (ball grid array) package with OSP (organic surface preservative) surface finish under thermal cycle was investigated by using SEM (scanning electron microscopy), EDS(energy dispersive spectroscopy), image tool and ball shear test. The IMCs (intermetallic compounds) were increased with increasing number of thermal cycles. However, the shear strengths of solder ball were decreased with increasing number of thermal cycles. The order of solders which had the highest shear strength as follow: Sn-3.5wt%Ag-0.7wt%Cu, Sn-0.7wt%Cu, Sn-37wt%Pb.

  • PDF

Experimental study on damage and debonding of the frozen soil-concrete interface under freeze-thaw cycles

  • Liyun Tang;Yang Du;Liujun Yang;Xin Wang;Long Jin;Miaomiao Bai
    • Structural Engineering and Mechanics
    • /
    • 제86권5호
    • /
    • pp.663-671
    • /
    • 2023
  • Freeze-thaw cycles induce strength loss at the frozen soil-concrete interface and deterioration of bonding, which causes construction engineering problems. To clarify the deterioration characteristics of the interface under the freeze-thaw cycle, a frozen soil-concrete sample was used as the research object, an interface scanning electron microscope test under the freeze-thaw cycle was carried out to identify the micro index information, and an interface shear test was carried out to explore the loss law of interface shear strength under the freeze-thaw cycle. The results showed that the integrity of the interface was destroyed, and the pore number and pore size of the interface increased significantly with the number of freeze-thaw cycles. The connection form gradually deteriorates from surface-to-surface contact to point-to-surface contact and point-to-point contact, and the interfacial shear strength decreases the most at 0-3 freeze-thaw cycles, with small decreases from to 3-8 cycles. After 12 freeze-thaw cycles, the interfacial shear strength tends to be stable, and shear the failure occurs internally in the soil.

원자 현미경을 이용한 접촉 면적에 따른 마찰 및 마멸 특성 분석 (Effect of Contact Area on Friction and Wear Behavior in Atomic Force Microscope)

  • 최덕현;황운봉
    • 한국정밀공학회지
    • /
    • 제21권12호
    • /
    • pp.167-173
    • /
    • 2004
  • Recently, it has been reported that frictional behavior at nanometer scale can be different from that at macro scale. In this article, friction and wear tests were conducted using an AFM to investigate the effect of real contact area on the coefficient of friction and wear property. SiO$_2$, Hica, and SiGe were used in friction test and the AFM tip was Si$_3$N$_4$. The real contact area between an AFM tip and flat surface was calculated by the Johnson-Kendall-Roberts (JKR) theory. Wear specimen was Mica, and the diamond tip was used. We found that the coefficient of friction is constant below a critical area, but it is degraded over the area. Moreover, it is found that wear depth increased rapidly from a certain load and was degraded as a function of the number of the scanning cycles. Also, the range of scanning velocity used in this study had little effect on the wear depth.

초음파를 이용한 배란의 연속관찰 (Consecutive Scanning of Ovulation Via Transvaginal Sonography)

  • 강윤철;김동석;이우호;박준영;오혜련;박영선
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제20권2호
    • /
    • pp.131-135
    • /
    • 1993
  • The ultrasonographic examination with vaginal probe(5MHz) was undertaken in 101 patients at infertility clinic of Eul-Ji General Hospital. This study was performed to evaluate the number of mature follicles per menstrual cycle, the relationship of both ovaries for consecutive ovulatory cycle and the responsiveness of follicular growth followed by administration of ovulation inductant. The results were as follows; 1. The ovulation induction group with clomiphene citrate showed more follicles than natural menstrual cycle group. 2. Each means of numbers of follicles between ovaries showed no difference between natural and ovulatory induction groups. 3. The rate of follicular growth per one menstrual cycle showed higher in the clomiphene citrate induced cycle group. 4. Clomiphene citrate induced group tends to be easier for multiple follicular growth but had no significant difference in statistics. 5. The ipsilateral Vs. contralateral follicular growth rate for consecutive menstrual cycles in both ovaries showed no significant difference between two groups.

  • PDF

Metagonimus yokogawai 세르카리아의 감각유두에 관한 연구 (Study on Sensory Papillae of Metagonimus yokogawai Cercaria)

  • 김재진;민득영소진탁
    • Parasites, Hosts and Diseases
    • /
    • 제22권1호
    • /
    • pp.11-20
    • /
    • 1984
  • A number of studies on the papillae of cercariae of trematodes reported that the papillar patterns (or chaetotaxy) of cercariae might be an excellent method to attain better understanding of the digenetic trematodes (Richard, 1971 ; Short and Cartrett, 1973; Bayssade-Dufour, 1979) . The present study was aimed to determine the number, distribution pattern and structure of the sensory papillae of Metagonimus yokogawai cercariae, and to elucidate the chaetotaxy of this digenetic trematode. M. yokogawai cercariae were pipetted from a vial in which infected snails (Semisulcospira libertina) had been kept for 3 hours. The snails were collected from an endemic area of M. yokogawai, Boseong river in west-southern part of Korea. Observations of papillae were based on light microscopy of those stained with silver nitrate, and on scanning electron microscopy The results are summarized as follows: 1, All papillae observed were uniciliated. 2. Cilia in anterior tip were shorter than the others in other portions. 3. The body papillae were arranged in essentially symmetrical patterns, Total number of the papillae was 126(63 pairs) in average; anterior tip 40(20 pairs), ventral 20(10 pairs), lateral 42(21 pairs), and caudal 8(4 pairs). 4. The chaetotany of M. yokogawai cercaria was: Ci cycle ($3+3C_{I}V,{\;}2+2C_{I}L,{\;}2+3C_{I}D),{\;}C_{II}{\;}cycle(2C_{II}V,{\;}1C_{II}L,{\;}2C_{II}D),{\;}C_{lll}{\;}cycle{\;}(1+lC_{III}V,{\;}1C_{IlI}L),{\;}C_{IV}{\;}cycle{\;}(1C_{IV}V,{\;}IC_{lV}L){\;}in{\;}cephalic{\;}region:{\;}A_I(1A_{IV}V,{\;}1+2A_{I}L,{\;}1A_{I}D),{\;}A_{II}(1A_{II}V,{\;}1+3A_{II}L,{\;}1A_{II}D),{\;}A_{III}(1A_{III}V,{\;}1+1A_{III}L,{\;}1A_{III}D){\;}and{\;}A_{IV}(1A_{IV}V,{\;}2A_{IV}L)$ in antacetabular region: $1M_{I}V{\;}and{\;}2M_{I}L$ in median: $1+1P_{I}L,{\;}1P_{II}L,{\;}1P_{II}D,{\;}1P_{III}L,{\;}1P_{IV}L{\;}and{\;}1P_{IV}D$ in postacetabular region: 2-2-2-2 in caudal region.

  • PDF

산화촉매를 장착한 대형 CNG 엔진의 나노입자 배출특성 (Nanoparticles Emission Characteristics of Heavy-Duty CNG Engine with Oxidation Catalyst)

  • 김태준;김화남;최병철
    • 동력기계공학회지
    • /
    • 제12권5호
    • /
    • pp.27-33
    • /
    • 2008
  • Natural gas has been considered one of the most promising alternative fuels for transportation because of its abundance as well as its ability to reduce regulated pollutants. We measured emission characteristics of nanoparticles from lean burn H/D(Heavy-Duty) CNG (Compressed Natural Gas) engine equipped with oxidation catalysts. The experiments were carried out to measure the emission and engine performance according to the ESC test cycle. The CO and THC conversion efficiencies on the best catalyst in the ESC test cycle achieved about 91 % and 83 %, respectively. From the measurement by the SMPS, the number of nanoparticles emitted from H/D CNG engine is reduced by about 99 % which is more than that of 2.5 L diesel engine. The particle number concentrations of H/D CNG engine were almost nanoparticles. Nanoparticles smaller than 30 nm emitted from the H/D CNG engine and diesel engine equipped with a CDPF(Catalyzed Diesel Particulate Filter) were quite similar. However, the particles bigger than 30nm from the CNG engine were smaller than the particles from diesel engine equipped with a CDPF. The higher the CNG engine load, the lower the particle number from engine-out, but it increased slightly at full load.

  • PDF

스크린 프린팅 탄소 전극의 이리듐 산화물 표면 개질과 이의 임피던스 센서 응용 (Surface Modification of a Screen-printed Carbon Electrode with Iridium Oxide and Its Application of an Impedance Sensor)

  • 길민식;윤조희;장진우;최봉길
    • 공업화학
    • /
    • 제34권5호
    • /
    • pp.493-500
    • /
    • 2023
  • 본 연구에서는 스크린 프린팅 공정을 통해 탄소 잉크 기반의 2상 전극을 제작하고, 전극 표면에 이리듐 산화물(IrOx)을 코팅함으로써 전극의 분극 현상을 제어할 수 있는 임피던스 센서를 개발하였다. IrOx는 순환 전압 전류법으로 탄소 전극의 표면 위에 순환 수(0~50 cycles)에 따라서 코팅되었다. 전자주사현미경을 이용하여 cycle 수가 증가할수록 IrOx 입자의 크기와 수가 증가하는 경향성을 확인하였다. 전기화학 임피던스 분석을 이용하여 상기 제조된 센서들의 NaCl 농도에 따른 임피던스 변화 값을 조사하였다. 50 cycle에서 제조된 센서가 가장 우수한 결정계수와 재현성을 나타내었으며, 이는 분극 현상이 잘 제어되었기 때문이다. 실제 용액 샘플들을 이용한 삼투압 장비와 비교 측정 실험을 수행함으로써 IrOx 기반 센서의 안구건조증 진단 센서로의 활용가치를 증명하였다.

누적압연접합에 의한 6061 Al 합금의 결정립 미세화와 마멸 특성 연구 (An Investigation of Sliding Wear and Microstructural Evolution of Ultra-Eine Grained 6061 Al Alloy Fabricated by ARB)

  • 이태오;김용석
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.147-150
    • /
    • 2001
  • The ARB (Accumulative Rolling Bonding) Process was applied to a 6061 Al alloy to obtain ultra-fine grains. After 4 ARB cycles at $315^{\circ}C$, original equilibrium large grains were transformed to ultra-fine grains of several hundred nano-meter size with nonequilibrium grain boundaries. At lower number of cycles, microsutcture of highly-tangled dislocation cells were observed. Large grains and coarsened precipitates filled the microstructure of specimens experienced ARB cycles more than 5. Sliding wear tests using a pin-on-disk type wear tester were conducted on the ARB processed 6061 Al alloy plate. Wear rates of the 6061 Al alloy increased with the increase of ARB cycle number as well as the applied load. Worn surfaces and debris, cross-sections of the worn specimen were examined with scanning electron microscopy (SEM) to investigate the wear mechanism of the ultra-fine grained 6061 Al Tensile properties of the 6061 Al alloy were also studied and used to correlate the wear test results with the microstructures, which evolved continuously with the number of ARB cycles.

  • PDF