• Title/Summary/Keyword: Number of patients

Search Result 6,010, Processing Time 0.04 seconds

Video Assisted Thoracic Surgery(VATS) of Pericardial Window Operation (비디오 흉강경을 이용한 심낭막 개창술)

  • 윤석원;김동관;김정원;박창률;김용희;박기성;박승일
    • Journal of Chest Surgery
    • /
    • v.35 no.11
    • /
    • pp.812-816
    • /
    • 2002
  • Pericardial effusions result from various conditions such as inflammation, malignancies, open heart surgery and uremia. Recently, video assisted thoracic surgery (VATS) has been used for diagnostic and therapeutic purposes in the management of pericardial effusion and intrathoracic lesions due to its ability to provide outstanding visibility of intrathoracic structures with less pain, superior cosmetic effects, and shorter hospital stay Material and Method: From April 1995 to October 2001, 51 patients received pericardial window operation via either thoracoscopic(Group A, n=37, m:f=18:19, mean age=56.4 yrs)or thoracotomy approach(Group B, n=14, m:f=8:6, mean age=58.4 yrs). Result: In group A, the operation time, duration of chest tube insertion, recurrence rate of pericardial effusion, and postoperative hospital stay were 61.2 minutes, 9.3 days, 2.7%, 16.2 days, respectively while in group B these values were 58.4 minutes, 12.2 days, 7.1, and 17.3 days. The number of injections for pain control in group A were 4.2 times, whereas in group B it was 6.3 times. Although there was a tendency for the mean hospital stay and duration of chest tube insertion to be shorter in group A than in group B, these differences did not reach statistical significance. There was also no significant difference in the operation time and recurrence rate between the two groups. Conclusion: The safety and effectiveness of VATS in the management of pericardial effusion is comparable to the open thoracotomy method. It allows for a shorter hospital stay, duration of chest tube insertion, lesser postoperative pain and a smaller skin incision.

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • Bulletin of the Korean Space Science Society
    • /
    • 1993.10a
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

A Study on the Job Performance of Dental Coordinators and Their Perception (치과코디네이터의 업무수행 및 인식도에 관한 조사연구)

  • Kwon, Soon-Bok;Kim, Young-Nam;Moon, Hee-Jung;Shin, Myung-Suk;Han, Gyeong-Soon;Han, Su-Jin
    • Journal of dental hygiene science
    • /
    • v.5 no.4
    • /
    • pp.211-220
    • /
    • 2005
  • The purpose of this study was to examine the job performance of dental coordinators and their perception of their job to lay the groundwork for utilizing dental personnels more efficiently. The subjects in this study were dental coordinators who worked at selected dental hospitals and clinics in Seoul, Gyeonggi province and Incheon. A survey was conducted to gather data from May 1 to August 8, 2005 and answer sheets from 108 respondents were analyzed. The findings of the study were as follows: 1. As for the length of service, 43.5 percent of the dental coordinators investigated had worked at dental institutes for five years or more, which was followed by less than two years(19.5%) and three years to less than five years(19.4%). Concerning the length of service as dental coordinators, 39.8 percent had served for less than two years, and 19.4 percent had worked for two years to less than three years and for five years or more respectively. Regarding the name of position, 38 percent were called team leaders, and 30.6 percent were called coordinators. As to duties, the largest group of them that stood at 30.6 percent were in charge of receiving, and in regard to department, the largest group, 57.4 percent, belonged to the treatment backup department. 2. Concerning education, the greatest number of them, 45.4 percent, had received education at private institutes, and 73.1 percent found it necessary for dental coordinators to take an authorized qualification test. 43.5 percent, the largest group, looked upon the central government as the best organization to authorize their qualifications and 70.8 percent believed that what they learned enabled them to perform their job successfully. As to the necessity of follow-up education as a means to improve job performance, 96.3 percent consented to it. As for the reason, 63.9 percent considered that necessary to enhance their own ability and 22.2 percent were in want of systematic education. Regarding educational expenses, 29.6 percent were subsidized by the dental institutes where they had worked and 25.9 percent had totally been responsible for that. Regarding a required course, medical service and marketing was most widely pointed out(66.7%), followed by theory and practice(65.7%) and introduction to dentistry(57.4%). As to what sort of education they wanted to receive more, dental service and marketing was selected the most, followed by practical health insurance(35.2%). 3. In regard to what type of job they performed as dental coordinators, 88.9 percent were in charge of appointment in the field of customer service, and 87.9 percent paid attention to having good manners as service providers in the area of self-management. In the field of hospital affairs, 81.3 percent were in charge of receiving. 4. As to their awareness of dental coordinator job, the largest group took pride in the job they performed ($3.99{\pm}0.76$), and the second largest group believed that dental coordinators made a great contribution to hospital management ($3.92{\pm}0.70$). The third largest group gave a great weight to their own job ($3.91{\pm}0.84$) in light of overall dental duties and the fourth largest group found themselves to get along with other employees regardless of position ($3.86{\pm}0.74$). The fifth largest group believed their job was of great use for promoting the oral health of patients ($3.76{\pm}0.75$), and the sixth largest group thought the future of dental coordinators was promising($3.74{\pm}0.86$). 5. In regard to their perception by age group, those who were older had a better opinion on every item of their job in general. Their age made a statistically significant difference to their view of the weight of dental coordinator job(P < 0.001) in light of overall dental duties, of being approved and trusted by managers(P < 0.01), of social awareness of dental coordinator, and of being understood and approved by other employees and dentists. Their pride in current job and their satisfaction with the name of their position were statistically significantly different according to their age as well. Besides, their age made a statistically significant difference to their opinion about whether or not there was an age limit to their occupation and about their contribution to hospital management (P < 0.05). 6. As for their perception by type of job, the dental hygienists were generally most satisfied with their job, followed by nursing aids and others. There was a statistically significant gap among their opinions about whether to make a job-related decision on their own(P < 0.001). the weight of their job in terms of overall dental duties, whether their job improved their ability, whether their job made a great contribution to enhancing the oral health of patients, whether their job was understood and approved by other employees(P < 0.01), social awareness of their job, whether they conflicted with other employees during job performance, and whether dental hospitals or clinics offered a self-development opportunity for them to take their ability to another level(P < 0.05). And their satisfaction with current pay was statistically significantly different as well.

  • PDF

The Present Status and a Proposal of the Prospective Measures for Parasitic Diseases Control in Korea (우리나라 기생충병관리의 현황(現況)과 효율적방안에 관(關)한 연구(硏究))

  • Loh, In-Kyu
    • Journal of Preventive Medicine and Public Health
    • /
    • v.3 no.1
    • /
    • pp.1-16
    • /
    • 1970
  • The present status of control measures for public health important helminthic infections in Korea was surveyed in 1969 and the following results were obtained. The activities of parasitic examination and Ascaris treatment for the positives which were done during 1966 to 1969 were brought in poor result and could not decrease the infection rate. It is needed to improve or strengthen the activities. The mass treatment activities for paragonimiasis and clonorchiasis in the areas which were designated by the Ministry of Health were carried out during 1965 to 1968 with no good results in decrease of estimated number of the patients. There were too many pharmaceutical companies where many kinds of anthelmintics were produced. It may be better to reduce the number of anthelmintics produced and control the quality. The human feces, the most important source of helminthic infections, was generally not treated in sanitary ways because of the poor sewerage system and no sewage treatment plant in urban areas and insanitary latrines in rural areas. The field soils of 170 specimens were collected from 34 areas out of 55 urban and tourist areas where night soil has been prohibited by a regulation to be used as a fertilizer, and examined for parasites contamination with the result of Ascaris egg detection in 44%. Some kinds of vegetables of 64 specimens each from the supply agents of parasite free vegetables and general markets were collected and examined for parasites contamination with the results of Ascaris egg detection in 25% and 36% respectively. The parasite control activities and the ability of parasitological examination techniques in the health centers of the country were not satisfactory. The budget of the Ministry of Health for the parasite control was very poor. The actual expenditure needed for cellophane thick smear technique was 8 Won per a specimen. As a principle the control of helminthic infections might be led toward breaking the chain of events in the life cycle of the prasites and eliminating environmental and host factors concerned with the infections, and the following methods nay be pointed out. 1) Mass treatment might be done to eliminate human reservoirs of an infection. 2) Animal reservoirs which are related with human infections night be eliminated. 3) The excretes of reservoirs, particularly human feces, should be treated in sanitary ways by the means of sanitary sewerage system and sewage treatment plant in urban areas and sanitary latrines such as waterborne latrine, aqua privy and pit latrine in rural areas. The increase of national economical development and prohibition of the habit of using night soils as a fertilizer might be very important factors to achieve the purpose. 4) The control of vehicles and intermediate hosts might be done by the means of prohibition of soil contamination with parasites, food sanitation, insect control and snail control. 5) The improvement of insanitary attitudes and bad habits which are related with parasitic infections night be done by the means of prohibition of habit of using night soils as a fertilizer, and improving eating habits and personal hygiene. 6) Chemoprophylactic measure and vaccination may be effective to prevent the infections or the development of a parasite to adult in the bodies when the bodies were invaded by parasites. Further studies and development of this kind of measures are needed.

  • PDF

A Study on Effects of Application of Nursing Process by Nursing Profess notes.(School of nursing) (간호기록지를 통해서 본 간호과정 적용효과에 관한 연구(간호전문대학을 중심으로))

  • 최상순;조희숙;백승남
    • Journal of Korean Academy of Nursing
    • /
    • v.11 no.2
    • /
    • pp.55-68
    • /
    • 1981
  • The prime object of the study is to evaluate how much all the students of the Nursing Schools throughout the nation are in comprehension toward the application of nursing process to clinical experience as means of systematic solution of nursing problems. An effort has been made to find out the actual state whether they are in practice of clinical experience in accordance with application of nursing process, over the period of four weeks managing from December 1st to 28th, 1980 and centering on 36 nursing schools, and meanwhile and evaluation, employing the assessment tool used by Bertuccietal, has been made on the nursing process notes recorded by 200 senions out of 21 nursing schools where application of nursing process to clinical experience being in practice. The assessment tool is composed of 5 different criteria in view of patient nursing and authors made an attempt to find out the result of clinical experience on application students in accordance with 5 different scoring criteria and further evaluating all the findings thereof. The findings were disposed of accordance with practice duration and criteria of the specific sudents subject to this finding as to verify the scoring difference in significance and of which the results are as follows: 1) as of now, in 21 (58.2%) out of 36 nursing Schools nursing process in being appliced in clinical experience. 2) Schools that started the application of nursing process to clinical experience amount to - for more than 4 yrs -6 (28.6%) - for 2 to 3 yrs-11s(52.4%) - for 1 yr -4 (19.0%) 3) As for the response upon application of nursing process. To clinical etperience, the largest voice (61.9%) heard was that it is rather difficult beyond the lecturing thereof, to practically apply it outs patients and the second voice (19.1%) turned out to be that it is hard to put in practice owing to uninformed nurses of the process serving in the clinical field. 4) The response. Of the processors assigned to instruction as to the most difficult problem in criteria of nursing process, the largest voice (38.2%) centered on the problem assessment while the second voice (17.7%) on the indirect nursing activity and the objective data respectively and considered to be the easiest was the indirect nursing activity (11.7%). 5) In order for a satisfactory. application of nursing process to clinical experience hence-forth, it has been pointed out that sufficient number of nurses should be supplemented in clinical field (44.1%) and at the same time supplementory education (35.3%) centered around professors be necessary. 6) Of the criteria that record result of nursing process, a significant difference in comprehension of subjective and objective data has been revealed according to the degree of the practice duration of application to clinical experience. For instance, while although poor it may seen, only 74.9% in subjective data and 71.1% in objective data represent the student group in practice for more than 4 years and only 56.3% in subjective data and 66.8% in objective data represent the student group in practice for 2 to 3 years but they still surpass in comprehension over the student group in practice for 1 year attaning only 19.6% in subjective data and 16.8% in objective data (P < 0.005). 7) As for problem assessment, the student group who started application of nursing process for 4 years stand for 37,7% the group for 2 to 3 years started for 25.3% and the group for 1 year started for 5.4%, revealing no significant difference according to duration (P < 0.5) and as poor as to indicate only 22.8% on an overage is in comprehension. 8) On direct and indirect nursing activity, the student group of for more than 4 years in appling nursing process (representing 49.5% in direct nursing activity, 21.4% in indirect nursing activity). Know more about it than the student group of for 2 to 3 years (representing 36.3% in direct nursing activity, 20.8% in indirect nursing activity) but revealed no significant difference. (P < 0.5) 9) The student group applying nursing process for more than 4 years subjective data (74.9%) comprehend were more than objective data (71.1%) but shown no significant difference (P < 0.5). 10) However, the student group applying nursing process for 2 to 3 years comprehend objective data (66.8%) well ever subjective data (55.5%) indicating that 40.9% in average is in comprehension, thereby revealing a significant difference (P < 0.005). 11) On the other hand, the student group applying nursing process to clinical experience for 1 year had revealed themselves as poorly as to comprehend only 11.7% are an average of it, revealing no significant difference (P < 0.5). In consequence of the fore going, I the conductor of the present study, hereby suggest the following points: 1) Application of nursing process to clinical experience be practiced in all the Nursing Schools all over the nation at the earliest possible date in order that scientific nursing be prevailed (as of now only 58.0%), 2) In teaching nursing process, it is desirable to teach specific method of applying to practical clinical situations. 3) In order to meet the end of satisfactory application of nursing process to clinical experience, sufgecient nursing man power be sysplemented in clinical field and at the save time supplementary education by professors is necessary. 4) Sinces the students whose application duration of nursing process to clinical experience is longer comprehend more about it, it is reguired that the schools not yet in practice of the application be promptlyurged to follow. 5) Of the criteria recording nursing process, since it is comparatively hard to comprehend“assessment”and“Direct and indirect nursing activity”, a concentrated instruction is desirable. 6) The students whose duration of application of nursing process to clinical experience falls short of 1 years be put in a concentrated guidance program on individual criterion.

  • PDF

The study on the entry of dental technicians in the public health center for a manpower supply and demand plane (Centering around a denture insurance policy in 2012) (인력수급 대책을 위한 치과기공사의 보건지소 진출에 관한 연구 - 2012년 틀니보험화 정책을 중심으로 -)

  • Lee, Jong-Do;Kim, Jeong-Sook;Park, Kwang-Sig
    • Journal of Technologic Dentistry
    • /
    • v.32 no.4
    • /
    • pp.417-433
    • /
    • 2010
  • Purpose: This study evaluated the manpower planning of dental technicians. Methods: Methods : Survey was conducted regarding subject's general characteristics, characteristics of dental technician's occupational view and working conditions, and reason to enter into branches of the public health enter. The survey sample consisted of 323 dental technicians (221 male/ 102 female). Survey was conducted for one month from August 1 to September 1 in 2010. Following results were obtained. Results: 1. Regarding general characteristics of the subjects, there was a slight male predilection with 68.4%. Subjects in their 40s occupied the highest proportion of 32.2%. Majority of subjects worked in the big cities (71.5%). Favored working places were dental laboratory (57.6%) and dental hospital or dental clinic (19.5%). Although no position is available in the public sector such as public health center or health care civil servant, 9.3% preferred working in the public health center. Public sector is more favored than 2-year technical colleges or dental supply and equipment companies. In respect to education, 57% of the subjects graduated college. 67.8% were married. Subjects who specialize in the porcelain or all-ceramic were 57.9%. With regard to current position, head of the dental laboratory was most common. 2. Following occupation characteristics were found. Economic reason took the highest proportion when deciding their occupation (39.9%) followed by gaining social experience (36.5%). Majority of the subjects (76.5%) wanted to work as dental technicians until their retirement. 71.5% pursuit to become a manager of the dental laboratory. 76.1% agreed on opening a dental technician position in the public health center. Regarding an authority to lead developing the dental technician position in the public sector, majority of the subject chose ministry of health and welfare (35.6%) and Korean dental technologist association (34.7%). Employment (average, 30%) and turnover rate (average, 36.5%) of dental technology college graduates ranged from 40% to 60%. Most important factors for the employment were practical experience (41.2%) and competency (34.4%). With regard to job satisfaction, so-so as 46.7% and satisfactory was 42.7% 3. In respect to the reason for opening a position in the public health center, 'It is needed to continue denture rogram for elderly patients' obtained the highest score (4.14 point). 'Institutional devices are required to open a position for dental technicians as a public healthcare provider' received high score (4.11 point). 4. Concerning the working conditions, 'professional knowledge is required' received the highest score (4.23) followed by 'too short maternity and parental leave' (4.21). 5. Relationship between general characteristics of the subjects and favor of working in the public health center was investigated. Significant differences were found according to the current and favored working area, favored occupation, education level, marital status, and specialty. Working in the public health center was favored by following subjects: working in mid- or small-sized cities (4.16 point, p<0.05); PhD degree-holder (4.59 point, p<0.01). 6. Among general characteristics of the subjects, significant difference of working conditions was found in the following factors: gender; working areas; favored working areas; favored working positions, and education level. Majority of subjects favored working in big cities and currently work in big cities although satisfaction was comparatively low (3.75 score). 7. Future plan to work in public health center was evaluated according to occupational characteristics. Subject's intention to work in the public healthcare center was significantly affected by opening of dental technician position, leading authority, average turnover rate, and factors affecting employment. Working in the public health care center was favored by the following subjects: Dental technicians who actively supported opening of the dental technician position (4.34 point, p<0.001); subjects who thought the Korean dental technologist association is responsible for the opening of positions in the public sector (4.26 point, p<0.001); and subjects who thought that attitude and character are important for the employment (p<0.001). 8. Concerning difference of working conditions according to the occupational characteristics, significant difference was demonstrated by factors such as a reason to choose to be a dental technician, work plan, pursuing position, responsible authority, average employment rate, and job satisfaction. High standard of working conditions was required in subjects who selected to be a dental technician for the leisure time after work (s.05 point, p<0.01), who planted to work until their marriage (4.25 point, p<0.001), and who pursuit to be a manager (3.98, p<0.05). 9. In respect to influence of general characteristics on the advancement to public health centers, the coefficient of determination (R2) was 0.068 and age affected the working condition with significant difference according to the pvalue. 10. Regarding influence of general characteristics on the advancement to public health centers, the coefficient of determination (R2) was 0.335 and work plan, opening of dental technician position in the public sector, and responsible authority had significant influence over the subject's intention to work in the public health center according to the p-value. 11. With regard to the influence of general characteristics on the advancement to public health centers, the coefficient of determination (R2) was 0.091 and reason to choose to be a dental technician, work plan, and responsible authority significantly affected subject's working conditions. Conclusion: Korean society is becoming a super-aged society according to several statistics. As aged population is rapidly increasing, national health insurance plans to cover denture for senior citizen over 75 years old from 2012. Therefore, dental technicians are urgently needed in the public health centers all over the nation. Many subjects in this study planed to work until their retirement and recognized dental technician's expertise. Ministry of health and welfare and Korean dental technologist association should co-operate each other to prepare foundation and institutional devices for dental technicians to advance into the public health center. This will improve oral health of the population. This study showed urgency of medical facilities and services which meets increasing number of aged population and welfare of the population.

Comparision of Chest Radiographs and Pulmonary Function in Coal Workers' Pneumoconiosis and Welders' Lung (탄광부 진폐증과 용접공 폐증에 있어 흉부-X선 소견과 폐기능의 비교)

  • Park, Dong-Youl;Hwang, Joo-Ho;Kang, Byung-Son;Chung, Chan-Su;Kim, Wha-Jo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.5
    • /
    • pp.713-722
    • /
    • 1995
  • Background: Chest X-ray of coal workers' pneumoconiosis and shipyard welders' lung show similar and regular opacities mostly, it is very difficult that we distinguish the former from the latter by only chest X-ray. so we performed this study to understand the progression of the disease and to provide the disease by considering pulmonary function and other factors in proportion to the profusion of small regular opacities of chest X-ray in both groups. Method: 430 coal workers' pneumoconiosis were compared with 311 shipyard welders' lung by the number, the age, the duration of dust exposure, %vital capacity(%VC), %FEV1.0, the type of ventilatory impairment, the combined pulmonary disease according to the profusion of small regular opacities on the chest radiographs, which were classified into category 0/1, category 1, and category 2. Result: 1) the percent of category 2 in coal workers' pneumoconiosis was 54.4%. the percent of category 1, and category 2 in welders' lung were 60.0%, 7.4%. the progression to the category 2 was higher in coal workers' pneumoconiosis than in welders' lung 2) The mean age was higher in coal workers' pneumoconiosis than in welders' lung, significantly increased in proportion to the progresion of profusion of small regular opacities in both groups 3) There was no difference in the duration of dust exposure by category 1/0, but the duration of dust exposure by category 1, 2 in coal workers' pneumoconiosis more significantly increased than in welders' lung. the duration in the proportion of category 2 to category 0/1, 1 significantly increased in the proportion to small regular opacities in coal workers' pneumoconiosis. but there was no significant difference in the proportion to small regular opacities in duration of dust exposure in welders' lung. 4) There was no significant difference of mean values of %VC(%vital capacity)in both groups except for category 1. the mean values of %VC had no relationship between the progression of small regular opacities in both groups. 5) The mean values of %FEV1.0 decreased more significantly in coal workers' pneumoconiosis than in welders' lung except for category 0/1. and decreased significantly in proportion to the profusion of small regular opacities in coal workers' pneumoconiosis. there was significant difference of %FEV1.0 in the proportion of category 2 to category 011 in welders' lung. 6) there were no significant difference of %FEV1.0, %VC in smoker and nonsmoker in both groups. 7) With regard to the type of ventilation in both groups in coal workers' pneumoconiosis 21.4 percent of patients belonged to the restrictive type, 11.6 percent to the obstructive type, 5.6 percent to the combined type, but in welders' lung 21.8 percent to the restrictive type, 2.9 percent to the obstructive type, 1.9 percent to the combined type. 8. in the pulmonary disease, the incidence of the pulmonary tuberculosis was the most in both groups, was more in coal workers' pneumoconiosis than welders' lung Conclusion: If we compare coal workers' pneumoconiosis with electric arc welders'lung by considering pulmonary function and other factors in proportion to the profusion of chest X-ray, I think that we will have the better result in understanding the progression of the disease and provision of the disease in both groups.

  • PDF

An Analysis of the Psychiatric Characteristics of the Alopecia Areata in Female (여성 탈모증의 정신의학적 특성 분석)

  • Lee, Kil-Hong;Na, Chul;Lee, Young-Sik;Lee, Chang-Hoon;No, Byung-In;Hong, Chang-Kwon
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.8 no.1
    • /
    • pp.31-45
    • /
    • 2000
  • Objectives : The present study was performed to reveal differences between female and male cases of alopecia in their alopecia related variables such as patterns of hair loss, psychiatric characteristics, associate illnesses, and methods of treatment, and to use them as basic materials for proper management and early prevention of the alopecia prone cases. Methods : In order to analysis the gender difference in hair losses, the subjects were divided into two subgroups as the 51 cases of female alopecia and the 42 cases of male alopecia, who had visited to the department of psychiatry consulted from the department of dermatology, Yongsan hopital, ChungAng University, Seoul, Korea, from January 1998 to December 1998. In data analysis, the subjects were statistically assesed by chi-squre test and analysis of varaiance, through SPSS-$PC^+$ 9.0V. Results : 1) Female subjects were more likely showed lower socio-economical level including lower eonomical level, lower educational level, or lower occupational level in their parent's job, were more likely to have larger number of siblings and to have many sisters comparison to the male cases. 2) Female subjects were more likely visited to the department of dermatology, more history of alopecia in their female family members, lesser history of alopecia in their male family members, more loss of hairs in vertex or frontal region of scalp, lesser loss of hairs in occipital region, and lesser nail changes in comparison to the male cases. 3) Female subjects were more suffered from intra-familial conflicts and economical changes, or their introverted personality makeup, lesser likely suffered from changes of business and health changes, and showed lesser conflicts related with poorer adaptaion in their job life. 4) Female subjects were more likely diagnosed as depression or conversion disorders, more frequently complaint anxiety symptoms or depressive symptoms, higher level of anxiety index, lesser complaint somatization or obsessive compulsive symptoms, and lesser diagnosed as anxiety disorder in comparison to the male cases. 5) Female subjects were more likely tended to show personality makeup such as the introverted, the lie, the repressed, or the feminine trends than the male cases. 6) Female subjects were more significantly treated by antianxiety drug such as etizolam and dermatological therapies include tretinoin, and lesser treated by clotiazepam and prednicarbonate in comparison to the male cases. Conclusion : From the facts that The most important factors in developing hair loss in the female subjects in comparison to the male cases seems to be closely correlated with the serious psychopathology such as the presence of mental disorders including depression, the presence of complaining anxiety or depressive symptomatology, the presence of stressful life events such as intrafamilial life changes, and the presence of personality makeup such as the introverted, the lie, the repressed, or the feminine trends, the authors confirmed that dermatologists act as the primary care physician are in a unique position to recognize psychiatric comorbidity and execute meaningful intervention for female patients with the alopecia with psychiatrists.

  • PDF

Community Residents' Knowledge, Attitude, and Needs for Hospice Care (일부 지역주민들의 호스피스에 대한 인지와 태도 및 간호요구 조사)

  • Ro, You-Ja;Han, Sung-Suk;Ahn, Sung-Hee;Yong, Jin-Sun
    • Journal of Hospice and Palliative Care
    • /
    • v.2 no.1
    • /
    • pp.23-35
    • /
    • 1999
  • Purpose : The hospice movement began about 30 years ago in Korea. However, basic studies have seldom been conducted about the general public's knowledge concerning hospice care and their needs for it. The purpose of this study was to investigate the general public's knowledge of and attitude toward hospice, and their needs for hospice care, and to analyze the needs for hospice care in relation to their knowledge and attitude in residents from a specific community. Methods : The survey was conducted with 924 people randomly selected from a district in Seoul. The data were collected through a self-reporting questionnaire constructed by the authors. With 30 items given in the questionnaire, the level of hospice needs showed Cronbach's alpha .89 in a pilot study and .92 in this study and the items were classified into four areas by a factor analysis. The data collected were analyzed by means of t-test and ANOVA. Results : 1) The average age of the respondents was 38. The majority of the respondents were well-educated. 2) Regarding awareness of hospice care, 54%(501 people) indicated they have heard of hospice. About 74% thought that people should be able to prepare for death in advance. About 83% wanted to be informed when they have life threatening illnesses such as terminal cancer. Also, about 63% responded that patients with terminal diseases should be provided with physical, spiritual, and psychological care for minimizing pain and peaceful death. Regarding the attitude toward hospice care, 74% responded that they would use hospice care if needed. The number of the respondents who preferred home visitation by the hospice team to care for the terminally ill ranked first with 34%. Concerning needs for hospice care : 1) By needs area, physical need showed highest mean(M=4.37), followed by social need(M=3.96), emotional need(M=3.87), and the spiritual need(M=3.79). The overall need level showed the mean value of 4.00 which reflects a considerable need for hospice care. 2) By demographic characteristics, people age over 50, the married, and the unemployed indicated higher level of needs for hospice care. Women showed higher level of needs than did men, and Catholics demonstrated higher level of needs than believers of other religion(P<0.0001). 3) As for the knowledge of and attitude toward hospice rare, the level of hospice care needs was significantly higher in the following groups: those who have heard of hospice, those who are aware of death preparation, those who want information on terminal diseases, those who want to use every method to sustain life, and those who are aware of hospice needs(P<0.001). Conclusion : It is assumed that the findings of this study on the knowledge, attitude, and needs for hospice care in the public can contribute to planning a successful hospice care program. Furthermore, the findings of this study will serve as useful data for the promotion of home hospice care to improve the quality of life of community residents, and contribute to the development of hospice care as a whole.

  • PDF