• Title/Summary/Keyword: Number of Bed

Search Result 687, Processing Time 0.029 seconds

A Study on the Estimation Method of the Consultation-Rooms for the O. P. D. in General Hospital (종합병원 외래진료부의 진찰실수 산정방법에 관한 연구)

  • No, Byung-Ok;Lee, Teuk-Koo
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.4 no.6
    • /
    • pp.67-76
    • /
    • 1998
  • The purpose of this study is to estimate the number of the consulation rooms for the O.P.D. in General Hospital. To estimate optimal number of consulation rooms, it has to be considered the factors of population density, neighboring medical supply, condition of location, and the number of bed etc. And the figure of Out-Patients has to be expected as exact as possible. In calculation of consulation rooms, existing hospital planning has been considered only the number of bed, without considering many other factors. According to it, the number of consulation rooms was calculated by consulation and then work out the total number of consulation rooms for the O.P.D.. Therefore this method has been had a lot of problems But. this study considered four factors, and calculated the total number of consulation rooms for O.P.D. and then worked out the number of consulation rooms by O.P.D.

  • PDF

A Study on the Heat Recovery from Boiler Exhaust Gas with Multi-stage Water-fluidized-bed Heat Exchanger (다단 물유동층 열교환기에 의한 보일러 배가스의 폐열 회수 성능에 관한 연구)

  • Kim, Dae-Gi;Park, Sang-Il;Kim, Han-Deok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.12
    • /
    • pp.1776-1783
    • /
    • 2001
  • Heat recovery from boiler exhaust gas with multi-stage water-fluidized-bed heat exchanger is analyzed in this study. The recovered energy here is not only sensible heat but also latent heat contained in the exhaust gas. In this system direct contact heat transfer occurs while exhaust gas passes through water bed and the thermal energy recovered this way is again delivered to the water circulating through heat exchanging pipes within the bed. Thus the thermal energy of exhaust gas can be recovered as a clean hot water. A computer program developed in this study can predict the heat transfer performance of the system. The results of experiments performed in this study agree well with the calculated ones. The heat and mass transfer coefficients can be fecund through these experiments. The performance increases as the number of stage increases. However at large number of stages the increasing rate becomes very low.

NUMERICAL ANALYSIS ON PRESSURE DROP IN EXPANDED BED ACCORDING TO TUBE-TO-PARTICLE RATIOS AND REYNOLDS NUMBERS (Expanded bed에서 레이놀즈수와 직경입자비에 따른 압력강하 특성에 관한 수치적 연구)

  • Bae, S.W.;Sung, H.G.;Roh, T.S.
    • Journal of computational fluids engineering
    • /
    • v.16 no.2
    • /
    • pp.62-65
    • /
    • 2011
  • Characteristics of the pressure drop in an expanded bed have been compared to those in a packed bed for numerical study of the interphase drag in gas-particle flows. A numerical analysis of the pressure drop by the particle drag has been conducted according to the tube-to-particle diameter ratios and Reynolds numbers for comparison. As the tube-to-particle diameter ratios increase at the same Reynolds number, the pressure drop tends to converge. It has been confirmed that characteristics of the pressure drop in the expanded bed are similar to those in the packed bed.

Effects of Soil Water Potential of Cutting Bed and Relative Humidity on the Rooting of Stem Cutting (삽목발근촉진(揷木發根促進)을 위한 토양(土壤) 및 대기수분관리(大氣水分管理))

  • Hong, Seong Cheon
    • Journal of Korean Society of Forest Science
    • /
    • v.42 no.1
    • /
    • pp.59-66
    • /
    • 1979
  • This experiment was carried out to know the effects of soil water potential of cutting bed and relative humidity on the rooting of stem cutting in the field plots. The results obtained were as follows; 1. The most number of the rooted cutting was found from 70 to 80% of relative humidity in Spring and from 90 to 100% in Summer respectively. 2. It was found that the number of rooted cutting was the least in the range of 0 to-0.006 bar of soil water potential of cutting bed in the case of Spring cutting, whereas in Summer the number of the rooted cutting was the most one in the range of -0.049 to -0.124 bar of soil water potential of cutting bed. 3. High signification was recognized between the relative humidity and the number of the rooted cutting only in the Spring cutting, but that of soil water potential and the number of the rooted cutting was found to be significant in every season.

  • PDF

Allowable Amount of Bed Inventory in a 300 MW Class Circulating Fluidized Bed Boiler (300 MW 급 유동층보일러에서 적정 층 물질량 산정)

  • Kim, Woo-Yong;Yoo, Ho-seon
    • Plant Journal
    • /
    • v.14 no.2
    • /
    • pp.33-38
    • /
    • 2018
  • The CFB boilers technology is facing a number of challenges. Among them, boiler tube erosion, sintering by bed inventory overheating and high self consumed service power are major ones. This study was conducted to obtain allowable bed inventory with the Yeosu Power Plant, a 300 MW class CFB boiler. For the test, bed pressure was reduced from design pressure of 4.5 KPa to 2.5 KPa by reducing bed inventory, at fixed turbine output, coal consumption rate and air flow. Consequently, reducing the lower bed inventory is effective to decrease bed temperature but excessive reducing might increase bed temperature due to lack of circulating fluidized materials. Also, in case of the Yeosu Plant boiler using subbituminous coal as its primary fuel, its bed temperature change is highly affected by not only the amount of bed inventory, but also the boiler capacity and coal contents.

  • PDF

A study on the fluidization of centrifugal fluidized bed for reduction of exhaust gas from diesel powered vehicle (경유차 배기가스 저감용 원심유동층 촉매반응장치의 유동특성에 관한 연구)

  • Rhee, Kwan-Seok;Kum, Sung-Min
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.2
    • /
    • pp.209-213
    • /
    • 2016
  • The characteristics of fluidization in a centrifugal fluidized bed with a 184 mm inner diameter, 50 mm width of the gas distributor was observed by photographs and experimental works using Cu-ZSM-5 zeolite catalysts with a mean diameter of $26{\mu}m$ and $32{\mu}m$ as bed materials at a rotor at 400rpm and 600rpm. Under these experimental ranges, the experimental results clearly showed the effects of the number of rotation of the rotor on the behavior of bubbles in the centrifugal fluidized bed. As the number of rotations of the rotor increased, the gas velocity at which bubbles begin to be formed also increased but the diameter of the bubbles decreased. In addition, the size of the bubbles in the centrifugal fluidized bed were relatively smaller than those in the conventional bubbling fluidized bed.

A Study on the Change of General Hospitals Size in Seoul during 15 years - Focused on General Hospitals bed and Gross Area in Seoul since 2005 (대도시 종합병원의 15년간 규모 변화 - 2005년 이후 서울특별시 소재 종합병원의 병상수와 연면적 변화)

  • Cho, Junyoung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.28 no.1
    • /
    • pp.53-61
    • /
    • 2022
  • Purpose: As the medical environment changes, the size of medical facilities continues to change. Of course, it is not easy to analyze the correlation between changes in the medical environment and changes in facility size in a rigorous scientific method. However, the results of investigating and analyzing changes in the size that occurred for any cause be able to serve as important references for future medical facility architectural plans. Methods: This study surveyed 68 general hospitals in Seoul for 15 years from 2005 to 2020. The change in the number of beds was investigated with data from the Ministry and Welfare. The gross area change was confirmed by analyzing the of all hospitals. Results & Implications: As a result of the survey, general hospitals in Seoul show a common phenomenon in which all hospitals except one case have expanded their size in the direction of increasing the gross area per bed over the past 15 years. However, in the method, a relatively small hospital with less than 500 beds mainly chose to reduce the number of beds. Large hospitals increased both the number of beds and the gross area, however showed a significant increase in the gross area.

Analysis on the fuel concentration distribution in a fluidized bed for the scale-up of a FBC (유동층 연소로의 스케일-업을 위한 유동층 내 연료농도분포 해석)

  • Lee, Dong-U;Park, Seung-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.6
    • /
    • pp.747-757
    • /
    • 1997
  • A numerical investigation of the fuel concentration field in a fluidized bed has been carried out for the scale-up of a fluidized bed combustor (FBC). A two-dimensional transient model is developed using the two-phase fluidization, a simple chemical reaction, and lateral solid mixing theories. The uniformity of fuel concentration distributions is controlled by the location and the number of fuel feeders, fluidizing velocities and the bed-heights. While larger bubbles owing to greater fluidizing velocities enhance the fuel-dispersion in the bed, they have adverse effects on fuel combustion and thus result in the increase of fuel concentration, since a greater bubble means a larger bypass which reduces gas-exchange rates between bubble and emulsion phases. Average or maximum values of the bed fuel concentration are utilized as criteria for the scale-up from a pilot/lab-scale to a commercial-size bed.

Efforts to obtain better rice seedlings performance under nontidal swamp land agro-ecosystem in south Sumatra, Indonesia

  • Suwignyo, Rujito A.;Sakagami, J.;Ehara, H.;Sulaiman, F.;Hasmeda, M.
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2017.06a
    • /
    • pp.50-50
    • /
    • 2017
  • Swampland is a potential alternative land to be used in various agricultural production activities in Indonesia, because Indonesia have 33.41 million hectares of swamp land that consists of 13.28 million hectares nontidal swamp and million hectares 20.13 tidal swamp. In the province of South Sumatra, because of unpredictable water level in the field before planting, farmers have been doing agronomic adaptation method through the delay time of transplanting and forced to apply more than one the nursery practice with the combination of a floating nursery method and a dry-bed nursery method. This study was aimed to (1) evaluate the seedling growth and tillering pattern of several popular Indonesian rice varieties, and (2) look for alternative technologies to get a better rice seedlings under two nursery methods in the nontidal swamp land. In the first experiment, the seedling growth characteristics of five rice varieties (Ciherang, Inpara 5, Inpara 9, Inpari 29, and Inpari 30) was evaluated by two methods of nursery, i.e. floating nursery and dry-bed nursery. In the second experiment, rice variety of Inpari 30 was treated with Zn seed priming and foliar fertilizer of 2,300 ppm N at the nursery stage. Those treatments were combined with the time of seedling under floating and dry-bed nursery. The results of the first experiment showed that of the five varieties tested, dry-bed nursery method showed better seedling growth than floating nursery. This was indicated by high leaf number, tiller number, tillers pattern, shoot-root ratio and relative growth rate. Ciherang and Inpari 30 showed high tiller number, and they had produced tertiary tiller in the sixth week of observation. Moreover, shorter period of floating and dry-bed nursery in combination with the treatment of Zn seed priming and spraying seedling with foliar fertilizer N could improve the growth of seedlings.

  • PDF

A Study on the Heat Recovery Performance of Water Fludized-Bed Heat Exchanger (물유동층 열교환기의 열회수성능 연구)

  • 김한덕;박상일;이세균
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.8
    • /
    • pp.690-696
    • /
    • 2003
  • This paper presents the heat recovery performance of water fluidized-bed heat exchanger. Temperature and humidity ratio of waste gas are considered as important parameters in this study. Therefore, the heat recovery rate through water fluidized-bed heat exchanger for exhaust gases with various temperatures and humidity ratios can be estimated from the results of this study. Mass flow ratio (the ratio of mass flow rate of water to that of gas) and temperature of inlet water are also considered as important operating variables. Increase of heat recovery rate can be obtained through either high mass flow ratio or low temperature of inlet water with resultant low recovered temperature. The heat recovery performance with the mass flow ratio of about up to 10 has been investigated. The effect of number of stages of water fluidized-bed on the heat recovery performance has been also examined in this study.