• Title/Summary/Keyword: Nuclear medicine imaging

Search Result 1,087, Processing Time 0.032 seconds

Scintigraphic Evaluation of Inhalation Injury in Fire Victims (화재사고시 흡입에 의한 기도손상의 핵의학적 평가)

  • Chun, Kyung-Ah;Cho, Ihn-Ho;Won, Gyu-Jang;Lee, Hyung-Woo;Shin, Kyung-Chul;Jeong, Jin-Hong;Lee, Gwan-Ho
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.1
    • /
    • pp.28-32
    • /
    • 2006
  • Purpose: Conventional chest X-ray and pulmonary function test cannot sensitively detect inhalation injury. Bronchoscopy is known to be the gold standard but it is invasive method. We evaluated whether lung inhalation/perfusion scans can sensitively detect inhalation injury of fire victims. Materials and Methods: Nineteen patients (male 9, female 10, mean age 31.6 yr) of fire victims were enrolled in this study. Inhalation lung scan was performed 2 days later after inhalation injury with $^{99m}Tc$-technegas. Perfusion lung scan was performed 4 days later with $^{99m}Tc$- MAA (macroaggregated albumin). Follow up lung scans were performed 16 and 18 days later for each. Chest X-ray was performed in all patients and bronchoscopy was performed in 17 of 19 patients at the same period. Pulmonary function test was performed in 9 patients. Results: Four of 19 patients showed inhalation and perfusion defects and one showed inhalation defect but, normal perfusion scan findings. These five patients with abnormal scan findings showed abnormal bronchoscopic findings and severe respiratory symptoms. On chest X-ray, 2 of them had pulmonary tuberculosis and one of them showed pulmonary congestion. FEV1 /FVC was abnormal in 3 patients. On the follow up scan, all patients with abnormal initial scan findings showed improved findings and they had improved clinical state. Conclusion: Inhalation/perfusion lung scans can detect inhalation burn injury noninvasively in early stage and may be useful in therapeutic decision making and follow up of patients.

Radioimmunoscintigraphy Using $^{99m}Tc-anti-CEA\;F(ab')_2$ Fragment in Rectal Cancer and a Pilot Study for Radioimmunoguided Surgery (직장암에서 $^{99m}Tc$-항CEA 항체 $F(ab')_2$ 분절을 이용한 수술 전 방사면역신티그라피 및 방사면역지침수술에 관한 기초 연구)

  • Ryu, Jin-Sook;Kim, Jin-Choen;Kim, Chang-Nam;Gong, Gyung-Yub;Lee, Hee-Kyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.3
    • /
    • pp.243-251
    • /
    • 2000
  • Purpose: This prospective study was performed to evaluate the usefulness of preoperative radioimmunoscintigraphy and intraoperative scintimetric examination (radioimmunoguided surgery: RIGS) using $^{99m}Tc-anti-CEA\;F(ab')_2$ fragment. Materials and Methods: Nineteen patients with rectal cancer underwent preoperative whole body planar scintigraphy at 4 hours after injection of $^{99m}Tc-anti-CEA\;F(ab')_2$ fragment and SPECT imaging at 18 hours. Surgical operation was performed at 24 hours after injection. During laparotomy, radioactivities from intraabdominal viscera were measured by gamma probe. The radioactivities from excised tumor and lymph nodes were also measured and compared with pathology. Results: All nineteen patients were confirmed to have adenocarcinomas in the rectum. Twenty-seven of 97 excised lymph node groups had metastasis and 2 patients had liver metastasis in pathology Preoperative radioimmunoscintigraphy detected primary tumors in 11 patients (sensitivity 55%) and it could not detect any lymph nodes or liver metastasis. All patients showed high radioactivity in the kidneys, liver, spleen, and major vessels in intraoperative measurement by gamma probe, and tumor activity was not discriminated from background activity However, radioactivity from excised tumor was higher than normal rectum (T/B ratio; $3.47{\pm}2.25$). When excised lymph node activity/background activity ratio >1.5 was considered as positive criteria of metastasis, sensitivity, specificity, positive and negative predictive values were 78.6%, 73.9%, 55.0% and 89.5%, respectively. Conclusion: Radioimmunoscintigraphy using $^{99m}Tc-anti-CEA\;F(ab')_2$ has no additional value for preoperative staging and use of early RIGS using $^{99m}Tc-anti-CEA\;F(ab')_2$ is inappropriate. For early RIGS using $^{99m}Tc$ labeled antibodies in rectal cancer patients, further development of more specific antibodies and methods to reduce background activity are needed.

  • PDF

Analysis of Urine Iodine Excretion Decrease by Two-Week Stringent Low Iodine Diet for Remnant Thyroid Ablation with Radioactive Iodine in Korean Patients with Thyroid Cancer; Prospective Study (한국 갑상선암 환자들에서 잔여갑상선 제거를 위한 방사성요오드 치료 전 2주간의 엄격한 저요오드식이에 의한 소변 내 요오드량 감소 분석; 전향적 연구)

  • Choi, Joon-Hyuk;Kim, Hoon-Il;Park, Jang-Won;Song, Eun-Hoon;Ko, Bong-Jin;Cheon, Gi-Jeong;Kim, Byung-Il
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.5
    • /
    • pp.375-382
    • /
    • 2008
  • A low iodine diet (LID) is the recommended preparation for radioactive iodine treatment. However, the recommended duration and stringency of LID are different among each recommendation. More stringent LID is expected in Korea because Korea is a iodine-rich region. We investigated the decrement of urine iodine excretion by two-week stringent LID for remnant thyroid ablation with radioactive iodine in Korean patients with thyroid cancer, prospectively. Material and Method: From November 2006, patients who referred to our hospital for remnant ablation after total thyroidectomy were included in this study. To decrease total body iodine, our protocol included three strategies. First, we checked medication which could inhibit the radioactive iodine uptake. Second, the date of 1-131 treatment was scheduled at least 3 months later if contrast agent had been used. The last strategy was two-week stringent LID education by specialized nutritionist. Before and after two-week stringent LID, 24hr-urine iodine was analyzed respectively. 24hr-urine creatinine was also analyzed for determining more valid 24hr urine sampling subgroup. Results: Total 51 patients were finally enrolled. Average of 24hr-urine iodine excretion was significantly lowered ($787{\pm}2242\;{\rightarrow}\;85{\pm}85\;{\mu}g/d$, p=0.03) after LID and 74.4% of patients reached below the recommended urine iodine excretion level ($<100\;{\mu}g/d$). In subgroup (n=14), similar results was showed ($505{\pm}666\;{\rightarrow}\;99{\pm}116\;{\mu}g/d$, p=0.05) and 78.6% of patients met the criteria. Conclusion: Most patients could reach below the recommended urine iodine level after two-week stringent LID. Therefore, in our opinion, at least two-week stringent LID should be recommended in Korea.

Comparison of I-131 Scintigraphy, T1-201 Scintigraphy, and Serum Thyroglobulin in the Postoperative Follow-Up of Differentiated Thyroid Cancer (분화된 갑상선암의 수술후 경과관찰에서 I-131 스캔, T1-201 스캔 및 혈청 갑상선 글로불린 농도의 비교)

  • Lee, Hyun-Kyung;Song, Jae-Soon;Shinn, Joon-Jae;You, Kye-Hwa;Cha, Wang-Ki;Kim, Eun-Sil;Kim, Chong-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.3
    • /
    • pp.346-355
    • /
    • 1997
  • To evaluate the utility of I-131, T1-201 scintigraphy, and serum thyroglobulin(Tg) in the follow-up of differentiated thyroid cancer, we compared retrospectively the data from 33 patients who underwent total or subtotal thyroidectomy. I-131 scintigraphy was performed after optimal endogenous TSH stimulation ($TSH>50{\mu}U/ml$). Total 41 cases of I-131 and T1-201 scintigraphy pairs were examined. Concomitant serum thyroglobulin levels were measured for 41 pairs of scan. Tg-off levels(that measured after discontinuation of the thyroid hormone) higher than 40ng/m1 were considered positive, and Tg-on levels(that measured during the thyroid hormone replacement) higher than 5ng/ml were considered positive. The concordance rates between I-131 therapeutic scintigraphy and T1-201 scintigraphy was 48% in the 38 case of total scan pairs(59% in the 17 cases of postoperative preablation group, and 38% in the 21 cases of postoperative postablation group). Of 17 studies before the I-131 ablation therapy(preablation group), 7 showed positive I-131 therapeutic scintigraphy despite of negative T1-201 scintigraphy. Among patients with negative I-131 therapeutic scintigraphy, no patients had abnormal T1-201 uptake. However, of 21 studies which were done after radioiodine therapy(postablation group) 6 had abnormal uptake on T1-201 scintigraphy which were not seen on I-131 therapeutic scintigraphy, and Tg-off levels also elevated in this 4 of 6 cases. As a result, I-131 therapeutic scintigraphy showed highest positive rate at postoperative preablation follow-up study in differentiated thyroid cancer patients. T1-201 scintigraphy may be useful in postablation studies, and the use of the combined modalities(T1-201 and Tg levels) provides a higher diagnostic yield.

  • PDF

The Role of Thallium-201 Scintigraphy in Bone and Soft Tissue Tumor (근골격계 종양에서 탈륨 스캔의 역할)

  • Shin, Duk-Seop
    • Journal of Yeungnam Medical Science
    • /
    • v.20 no.2
    • /
    • pp.117-128
    • /
    • 2003
  • Thallium-201 scintigraphy is used to discriminate the malignant bone tumor from the benign by qualitatively and quantitatively, and to predict the response of preoperative chemotherapy in osteosarcoma, by comparing the changes of thallium uptake ratio after chemotherapy to the tumor necrosis ratio. Thallium-201 scintigraphy scan should be done prior to surgical biopsy. PICKER Prism 2000 gamma camera with high resolution parallel hole collimator is usually used for scanning. The patient is injected with 2-3mCi of Tl-201 and the early phase is checked in 30 minutes and delayed phase in 3 hours. The scan images are visually evaluated by a blinded nuclear medicine physician. We could evaluate true positive, true negative, false positive and false negative by the comparison of results with those of biopsy, and calculate positive and negative predictive value(%), sensitivity(%), specificity(%) and diagnostic accuracy(%). For the quantitative analysis of thallium uptake, we drew the region of interest on the tumor side and contralateral normal side as mirror image, and calculated the uptake ratio with dividing the amount of gamma count in tumor side by normal side. We could calculate the percent changes of thallium uptake ratio in early and delayed phase, and compare them to the ratio of tumor necrosis. Thallium-201 scintigraphy proved as useful imaging study to discriminate malignant bone tumor from benign, but had exception in giant cell tumor and low grade malignant bone tumors. We can use T1-201 scan to differentiate the benign from the malignant tumor, and to evaluate the response of preoperative chemotherapy or radiotherapy, and to determine the residual tumor or local recurrence. For the better result, we need to have a more detail information about false positive cases and a more objective and quantitative reading technique.

  • PDF

Magnetic resonance image-based tomotherapy planning for prostate cancer

  • Jung, Sang Hoon;Kim, Jinsung;Chung, Yoonsun;Keserci, Bilgin;Pyo, Hongryull;Park, Hee Chul;Park, Won
    • Radiation Oncology Journal
    • /
    • v.38 no.1
    • /
    • pp.52-59
    • /
    • 2020
  • Purpose: To evaluate and compare the feasibilities of magnetic resonance (MR) image-based planning using synthetic computed tomography (sCT) versus CT (pCT)-based planning in helical tomotherapy for prostate cancer. Materials and Methods: A retrospective evaluation was performed in 16 patients with prostate cancer who had been treated with helical tomotherapy. MR images were acquired using a dedicated therapy sequence; sCT images were generated using magnetic resonance for calculating attenuation (MRCAT). The three-dimensional dose distribution according to sCT was recalculated using a previously optimized plan and was compared with the doses calculated using pCT. Results: The mean planning target volume doses calculated by sCT and pCT differed by 0.65% ± 1.11% (p = 0.03). Three-dimensional gamma analysis at a 2%/2 mm dose difference/distance to agreement yielded a pass rate of 0.976 (range, 0.658 to 0.986). Conclusion: The dose distribution results obtained using tomotherapy from MR-only simulations were in good agreement with the dose distribution results from simulation CT, with mean dose differences of less than 1% for target volume and normal organs in patients with prostate cancer.

Clinical Practice Guidelines for Gastric Cancer in Korea: An Evidence-Based Approach

  • Lee, Jun Haeng;Kim, Jae G.;Jung, Hye-Kyung;Kim, Jung Hoon;Jeong, Woo Kyoung;Jeon, Tae Joo;Kim, Joon Mee;Kim, Young Il;Ryu, Keun Won;Kong, Seong-Ho;Kim, Hyoung-Il;Jung, Hwoon-Yong;Kim, Yong Sik;Zang, Dae Young;Cho, Jae Yong;Park, Joon Oh;Lim, Do Hoon;Jung, Eun Sun;Ahn, Hyeong Sik;Kim, Hyun Jung
    • Journal of Gastric Cancer
    • /
    • v.14 no.2
    • /
    • pp.87-104
    • /
    • 2014
  • Although gastric cancer is quite common in Korea, the treatment outcome is relatively favorable compared to those in western countries. However, there are currently no Korean multidisciplinary guidelines for gastric cancer. Experts from related societies developed guidelines de novo to meet Korean circumstances and requirements, including 23 recommendation statements for diagnosis (n=9) and treatment (n=14) based on relevant key questions. The quality of the evidence was rated according to the GRADE evidence evaluation framework: the evidence levels were based on a systematic review of the literature, and the recommendation grades were classified as either strong or weak. The applicability of the guidelines was considered to meet patients' view and preferences in the context of Korea. The topics of the guidelines cover diagnostic modalities (endoscopy, endoscopic ultrasound, and radiologic diagnosis), treatment modalities (surgery, therapeutic endoscopy, chemotherapy, and radiotherapy), and pathologic evaluation. An external review of the guidelines was conducted during the finalization phase.

Hypermetabolism of Compensatory Laryngeal Muscles in Unilateral Vocal Cord Palsy: Comparison Study between Speech and Silence with Normal Subjects by Co-registered PET-CT Fusion Images (일측 성대마비 환자의 보상기전에 관여하는 후두내근육 : PET-CT 융합 영상을 사용한 정상군과의 발성시 및 비발성시의 비교)

  • Pai, Moon-Sun;Kim, Hyon-Kyong;Kim, Han-Su
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.1
    • /
    • pp.23-27
    • /
    • 2006
  • Purpose: There are a few case reports on asymmetric vocal cord uptake on FDG-PET in patients with unilateral vocal cord paralysis, which could be a potential pitfall in the interpretation of FDG-PET images. We evaluated the metabolic activity of laryngeal muscles of patients with unilateral vocal cord paralysis in comparison to normal controls during both speech and silence. Methods: Eleven patients with unilateral vocal cord palsy (thyroldectomy=7, lung cancer=1, others=3) and 12 normal controls underwent FDG-PET with usual protocol. They were divided into two groups respectively; one group read books aloud for 20 minutes (phonation group) and the other kept silence (non-phonation groups) after FDG injection. Recent neck CT scan were co-registered with FDG-PET to produce PET-CT fusion images to elaborate small laryngeal muscles. Results: In patients with unilateral vocal cord palsy, contralateral non-paralyzed vocal cord showed hypermetabolism mainly on thyroarytenoid muscle, more intensely with phonation group ($SUV=5.88{\pm}2.65$) than with non-phonation group ($SUV=2.30{\pm}0.39$). Normal control subjects showed hypermetabolism ($3.68{\pm}0.96$) in interarytenoid muscle and symmetric mild hypermetabolism in both lateral cricoarytenoid muscles in only phonation group. Conclusion: FDG-PET with fusion images using CT scan in patients with unilateral vocal cord paralysis showed hypermetabolism of contralateral non-paralyzed thyroarytenoid muscle, suggesting compensatory action during phonation. Phonation durung FDG PET study enhanced FDG uptake on different laryngeal muscles between patients with unilateral vocal cord paralysis and normal subjects.

$^{99m}Tc-MAG_3$ Elimination Index on Normal Functioning Transplanted Kidney ($^{99m}Tc-MAG_3$ 제거지수를 이용한 이식신장의 기능평가)

  • Jeon, Woo-Jin;Kim, Ju-Heon;Park, Mi-Ok;Lee, Hee-Jung;Hyun, Jung-Ae;Zeon, Seok-Kil
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.1
    • /
    • pp.79-83
    • /
    • 1995
  • Purpose : We analysed $^{99m}Tc-MAG_3$ renal scans to evaluate renal function of transplanted kidney and to detect various renal transplant complications, measuring the ratio of renal radioactivity at three minutes to that at 20 minutes(elimination index). Material and Methods : The fifty seven renal transplantation recipients were studied. There were 50 normal functioning transplanted kidneys as group I and 7 abnormal function-ing transplanted kidney, including 5 cases of acute renal rejection, 2 cases of acute tubular necrosis as group IIl. The protocol consisted of: (1) $^{99m}Tc-MAG_3$ 740MBq injection intravenously : (2) sequential imaging for 2min(60two-second images) followed by 30min(30 sixty-second images) : (3) drawing of region of interest(ROI) on renal imaging; (4) time-activity corves were generated from renal ROI after background subtraction, and time of maximum activity($T_{max}$) and half time of maximal peak radioactivity($T_{1/2}$) were produced in the renogram curve. (5) EI through Bischof-Delaloye method as determined on the renogram curve. Results : Normal group( I ) shows mean EI of 2.21(95.0% Confidence limit of 2.01-2.87), $T_{max}$ of 154 sec, $T_{1/2}$ of 1,139 sec. Abnormal group(II) shows mean EI of 0.74, $T_{max}$ of 1,466 sec, $T_{1/2}$ of 19,224 sec. The EI, $T_{max}$, $T_{1/2}$, BUN and serum creatinine values are significantly different between normal group(I) and abnormal group(II) (p<0.0001). Conclusion : By measuring EI with $^{99m}Tc-MAG_3$, renal function of transplanted kidney could be easily evaluated and various complications could be detected early.

  • PDF

Development and Performance Test of Preamplifier and Amplifier for Gamma Probe (감마프로브용 전단증폭기와 주증폭기의 개발과 성능 평가)

  • Bong, Jung-Kyun;Kim, Hee-Joung;Lee, Jong-Doo;Kwon, Soo-Il
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.1
    • /
    • pp.100-109
    • /
    • 1999
  • Purpose: Preamplifier and amplifier are very important parts for developing a portable counting or imaging gamma probe. They can be used for analyzing pulses containing energy and position information for the emitted radiations. The commercial Nuclear Instrument Modules (NIMs) can be used for processing these pulses. However, it may be improper to use NIMs in developing a portable gamma probe, because of its size and high price. The purpose of this study was to develop both preamplifier and amplifier and measure their performance characteristics. Materials and Methods: The preamplifier and amplifier were designed as a charge sensitive device and a capacitor resistor-resistor capacitor (CR-RC) electronic circuit, respectively, and they were mounted on a print circuit board (PCB). We acquired and analyzed energy spectra for Tc-99m and Cs-137 using both PCB and NIMs. Multichannel analyzer (Accuspec/A, Canberra Industries Inc., Meriden Connecticut, U.S.A) and scintillation detectors (EP-047(Bicron Saint-Gobain/Norton Industrial EP-047 (Ceramics Co., Ohio, U.S.A) with $2"{\times}2"$ NaI(T1) crystal and R1535 (Hamamatsu Photonics K.K., Electron Tube Center, Shizuoka-ken, Japan) with $1"{\times}1"$ NaI(T1) crystal were used for acquiring the energy spectra. Results: Using PCB, energy resolutions of EP-047 detectors for Tc-99m and Cs-137 were 12.92% and 5.01%, respectively, whereas R1535 showed 13.75% and 5.19% of energy resolution. Using the NIM devices, energy resolutions of EP-047 detector for Tc-99m and Cs-137 were measured as 14.6% and 7.58%, respectively. However, reliable energy spectrum of R1535 detector could not be acquired, since its photomultiplier tube (PMT) requires a specific type of preamplifier. Conclusion: We developed a special preamplifier and amplifier suitable for a small sized gamma probe that showed good energy resolutions independent of PMT types. The results indicate that the PCB can be used in developing both counting and imaging gamma probe.

  • PDF