• Title/Summary/Keyword: Nuclear medicine imaging

Search Result 1,089, Processing Time 0.032 seconds

Interictal rCBF SPECT, MRI and Surgical Outcome of Intractable Temporal Lobe Epilepsy (난치성 측두엽간질의 발작간 뇌혈류 SPECT, MRI와 수술성과 비교)

  • Zeon, Seok-Kil;Joo, Yang-Goo;Lee, Sang-Doe;Son, Eun-Ik;Lee, Young-Hwan
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.3
    • /
    • pp.307-312
    • /
    • 1994
  • Interictal single photon emission computed tomography of regional cerebral blood flow (rCBF SPECT) in 18 intractable temporal lobe epilepsy patients(8 male and 10 female patients: average 23.5 years old) were compared with 2.0 T magnetic resonance imaging (MRI). And surgical outcome was analysed with the findings, symptom duration and lateralization of temporal lobe. Preoperatively rCBF SPECT was done in all 18 patients with intravenous injection of 740 MBq 99mTc-HMPAO. MRI was also done preoperatively in 13 patients. Surgical outcome was classified by Engel's outcome classification(four-part classification recommended at the first Palm Desert conference). rCBF SPECT detected correctly lateralising abnormality of temporal lobe hypoperfusion in 13/18(72.2%), contralateral temporal lobe hypoperfusion in 2/18(11.1%) and showed no def-inite abnormality in 3/18(16.7%). The positive predictive value of unilateral temporal lobe hypoperfusion was 87%. MRI detected correct localising abnormality in 8/13(61.5%), such as hippocampal atrophy(7/13), asymmetric temporal horn(6/13), anterior temporal lobe atrophy(1/13), increased signal intensity from hippocampus(1/13) and calcific density(1/13), and no abnormal finding was noted in 5/13(38.5%). There was no false positive findings and the positive predictive value of MRI was 100%. Only 2 cases showed same lateralization findings in rCBF SPECT and MRI. There was no significant correlation between symptom duration and no abnormal findings on SPECT or MRI. Surgical outcome showed class I in 15/18(83.3%), and class II in 2/18(11.1%). One case of no abnormal finding in both SPECT and MRI showed class III surgical outcome. No class IV surgical outcome was noted. Surgical outcome, lateralization of epileptic focus in temporal lobe and abnormal findings in rCBR SPECT or MRI were not significantly correlated.

  • PDF

Comparison of $Na^+/I^-$ Symporter Expression Rate in Malignant and Benign Thyroid Diseases: Immunohistochemical Study (악성 및 양성 갑상선 질환의 조직에서 면역조직학적 검사법에 의한 $Na^+/I^-$ symporter의 발현율 비교)

  • Kang, Do-Young;Jeong, Young-Jin;Lee, Kyung-Eun;Park, Heon-Soo;Yoo, Young-Hyun;Roh, Mee-Sook
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.1
    • /
    • pp.9-15
    • /
    • 2006
  • Purpose: Previous studies have not showed consistent results for the level of expression of sodium/iodide symporter (NIS) in thyroid diseases, especially malignant tumor. We undertook this study to evaluate the distribution of NIS expression in malignant thyroid diseases and compare with that in benign thyroid disease. Materials and Methods: Total patients were 119 cases (Men 15, $48{\pm}13$ yrs). Total number of samples were 205 pieces. In malignant thyroid disease, there were 153 samples: 90 in papillary carcinoma, 4 in follicular carcinoma, 2 in medullary carcinoma and 57 in metastatic lymph node. In benign thyroid disease, there were 52 samples: 36 in goiter/cyst, 11 in thyroiditis and 5 in follicular adenoma. Using immunohistochemical methods, we probed 205 samples with monoclonal anti-NIS Ab. Grading of staining was stored as 0 (negative or absent), 1 (weakly positive), 2 (moderately positive) or 3 (strongly positive). Expression rate (ER) of NIS positivity in individual disease entity was expressed as percentage of total number divided by number in 2 plus 3 grade. Results: ERs of malignant thyroid diseases were 63% in papillary carcinoma, 81% in metastatic lymph node, 71% in follicular carcinoma and 100% in medullary carcinoma. ERs of benign thyroid disease were 53% in goiter/cyst, 64% in thyroiditis and 40% in follicular adenoma. ER of malignant thyroid diseases was higher than benign thyroid diseases (71% vs 54%). Grading of NIS expression in papillary carcinoma or goiter/cyst was heterogeneously distributed in considerable cases. Normal tissue also showed heterogeneous distribution of NIS expression, which was not correlated with that of primary lesion. Conclusion: In papillary thyroid carcinoma, distribution of NIS expression was heterogeneous and increased, and not different compared with that of benign thyroid disease.

Comparison of Urine Iodine/Creatinine ratio between Patients following Stringent and Less Stringent Low Iodine Diet for Radioiodine Remnant Ablation of Thyroid Cancer (갑상선암의 방사성요오드치료를 위한 저요오드식이 방법 차이에 따른 소변 중 요오드/크레아티닌 비의 비교)

  • Roh, Jee-Ho;Kim, Byung-Il;Ha, Ji-Su;Chang, Sei-Joong;Shin, Hye-Young;Choi, Joon-Hyuk;Kim, Do-Min;Kim, Chong-Soon
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.6
    • /
    • pp.322-326
    • /
    • 2006
  • A low iodine diet (LID) for $1{\sim}2$ weeks is recommended for patients who undergoing radioiodine remnant ablation. However, the LID educations for patients are different among centers because there is no concrete recommendation for protocol of LID. In this investigation, we compared two representative types of LID protocols performed in several centers in Korea using urine iodine to creatinine ratio (urine I/Cr). Methods: From 2006, April to June, patients referred to our center for radioiodine remnant ablation of thyroid cancer from several local hospitals which had different LID protocols were included. We divided into two groups, stringent LID for 1week and less stringent LID for 2 weeks, then measured their urine I/Cr ratio with spot urine when patients were admitted to the hospital. Results: Total 27 patients were included in this investigation (M:F=1:26; 13 in one-week stringent LID; 14 in two-week less stringent LID. Average of urine I/Cr ratio was $127.87{\pm}78.52{\mu}g/g$ in stringent LID for 1 week, and $289.75{\pm}188.24{\mu}g/g$ in less stringent LID for 2 weeks. It was significantly lower in stringent LID for 1 week group (p=0.008). The number of patients whose urine I/Cr ratios were below $100{\mu}g/g$ was 6 of 13 in stringent LID for 1 week group, and 3 of 14 in less stringent LID for 2 weeks group. Conclusion: Stringent LID for 1 week resulted in better urinary I/Cr ratio in our investigation compared with the other protocol. However it still resulted in plenty of inadequate range of I/Cr ratio, so more stringent protocol such as stringent LID for 2 weeks is expected more desirable.

A Study on Enacting the Radiologic Technologist Act for the Civil Right to Health in Korea (건강권과 방사선사법 제정에 관한 고찰)

  • Lim, Chang-Seon
    • Journal of radiological science and technology
    • /
    • v.30 no.4
    • /
    • pp.313-320
    • /
    • 2007
  • There are the Medical Radiation Health and Safety Act(the Patient Radiation Health and Safety Act, the Radiologic Technologist Act), the Medical Laboratory Technologist Act, the Physical Therapy Practice Act, and the Dental Hygienist Act, etc in America. However, Korea has only one Act for a medical radiologic technologist(including radiation therapy technologist, nuclear medicine technologist), medical laboratory technologist, physical therapist, occupational therapy examiner, dental hygienist, and so on. It is the Medical Technologist Act. Therefore, the Medical Radiation Health and Safety Act for a radiologic technologist(including radiation therapy technologist, nuclear medicine technologist) has to be enacted independently in Korea. It is the purpose of this Act to provide for the appropriate certification of persons using radioactive materials, equipment emitting ionizing radiation on humans or performing medical imaging for diagnostic and therapeutic purposes. In Korea, the radiologic technologist is a "fusion technologist" who is a person other than a licensed practitioner as a radiographer, radiation therapist, nuclear medicine technologist, computed tomography technologist, magnetic resonance technologist, mammographer, sonographer, medical dosimetrist, quality management technologist, etc. This Act will have some provisions related to the definitions, reserved title, scope of practice, specialized technologist, application for licensure, radiologic technology council, renewal, continuing education, the radiation control advisory commission, etc. This Act will ensure that quality radiation therapy treatments are delivered and that quality diagnostic information is presented for interpretation, which will lead to accurate diagnosis, treatment and cure. Accurate diagnosis can be provided only when a personnel is properly educated in technique, equipment operation and radiation safety. In the end, this Act will protect the civil right to health. By regulating the personnel responsible for performing those procedures, this Act will mean improved care for patients-higher quality images, improved accuracy, and less exposure to radiation.

  • PDF

Quantitative Analysis of Artifactual Perfusion Defects due to the Cutoff Frequencies of Reconstruction Filters in Tc-99m-MIBI Myocardial SPECT Images (Tc-99m-MIBI 심근 SPECT에서 재구성필터의 차단주파수에 의한 인위적 관류결손의 정량적 평가)

  • Kwark, Cheol-Eun;Chung, June-Key;Lee, Myung-Chul
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.2
    • /
    • pp.231-238
    • /
    • 1995
  • Tc-99m-MIBI (Sestamibi) myocardial SPECT along with TI-201 tomographic Imaging has demonstrated wide application and high image quality sufficient for the diagnosis of myocardial perfusion defect, which consequently reflects regional myocardial blood flow. The qualitative values of myocardial SPECT with Tc-99m-MIBI as well ds the quantitative cases depend in some degree on the reconstruction techniques of multiple projections. Filtered backprojection (FBP) Is the common standard method for reconstruction rather than the complicated and time-consuming arithmetic methods. In FBP it is known that the distribution of radioactivity in reconstructed transverse slices varies with the selected litter parameters such as cutoff frequencies and order (Butterworth case) The cutoff frequencies used in clinicAl practice partially remove and decrease the true radioactive distribution and alter the pixel counts, which lead to underestimation of true counts in specific myocardial regions. In this study, we have investigated the effect of cutoff frequencies of reconstruction filter on the artifactually induced perfusion defects, which are often demonstrated near inferior and/or inferoseptal cardiac walls due to the intense hepatic uptake of Tc-99m-MIBI. A computerized method for Identifying the relative degree of artifactual perfusion defect and for comparing those degrees along with the relative amount of hepatic uptake to myocardium was developed and patient images were studied to observe the quantitative degree of underestimation of myocardial perfusion, and to propose some reasonable threshold of cutoff frequency in the diagnosis of perfusion defect quantitatively. We concluded that from the quantitative viewpoint cutoff frequencies may be used as high as possible with the sacrifice of homogeneity of image quality, and those frequencies lower than the common 0.3 Wyquist frequency would reveal severe degradation of radioactive distribution near inferior and/or inferoseptal myocardium when applying Butterworth or low pass filter.

  • PDF

Studies on the Biological Behaviors of Taxol Derivatives (Taxol 유도체들의 생물학적 거동에 관한 연구)

  • Awh, Ok-Doo;Yoo, Dae-Wung;Im, Sang-Moo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.4
    • /
    • pp.440-451
    • /
    • 1997
  • This study was designed to prospect the $^{111}In$-labelled paclitaxel as tumor imaging agent. In order to provide a taxol molecule with a functional group which is able to chelate In-111, taxol-DTPA conjugate and 2'-hemisuccinyltaxol were synthesized by esterification of taxol at C-2'on C-13 carbon with DTPA anhydride and succinic anhydride, respectively. Synthesis yield of the taxol derivatives was 34% for taxol-DTPA and 80% for 2'-hemisuccinyltaxol. Cytotoxicity of the taxol derivatives were measured by MTT method toward cell lines HT29, B16, P388, and CT26. The cytotoxic activities of the taxol derivatives were maintained, although less active than taxol. Radiolabelling of the taxol derivatives were proceeded directly with $^{111}InCl_3$ or indirectly with $^{111}In$-citrate(ligand-exchange method). The ligand-exchange method was not suitable because some precipitates appeared during the reaction. On the contrary, by direct radiolabelling method, we were able to obtain taxol-DTPA-$^{111}In$ in 100% radiochemical yield. However, 2'-hemisuccinyltaxol was not labelled by both methods. Yield and radiochemical purity of the radiolabelled com-pound were determined by HPLC, paper chromatography and instant thin layer chromatography. Taxol-DTPA-$^{111}In$ was characterized to be hydrophilic by lipophilicity test, and nearly non-adhesive to HT29, B16, P388, and CT26 by cell binding affinity test. Binding affinity of the taxol-DTPA-$^{111}In$ complex to serum proteins was also examined by protein precipitation with 30% trichloroacetic acid. The results showed that 30% of the taxol-DTPA-$^{111}In$ complex binds with serum proteins.

  • PDF

Significantly Low Effective Dose from 18FDG PET/CT Scans Using Dose Reducing Strategies: "Lesser is Better"

  • uz Zaman, Maseeh;Fatima, Nosheen;Zaman, Areeba;Zaman, Unaiza;Tahseen, Rabia
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.7
    • /
    • pp.3465-3468
    • /
    • 2016
  • Background: Fluorodeoxyglucose ($^{18}FDG$) PET/CT imaging has become an important component of the management paradigm in oncology. However, the significant imparted radiation exposure is a matter of growing concern especially in younger populations who have better odds of survival. The aim of this study was to estimate the effective dose received by patients having whole body $^{18}F$-FDG PET/CT scanning as per recent dose reducing guidelines at a tertiary care hospital. Materials and Methods: This prospective study covered 63 patients with different cancers who were referred for PET/CT study for various indications. Patients were prepared as per departmental protocol and 18FDG was injected at 3 MBq/Kg and a low dose, non-enhanced CT protocol (LD-NECT) was used. Diagnostic CT studies of specific regions were subsequently performed if required. Effective dose imparted by 18FDG (internal exposure) was calculated by using multiplying injected dose in MBq with coefficient $1.9{\times}10^{-2}mSv/MBq$ according to ICRP publication 106. Effective dose imparted by CT was calculated by multiplying DLP (mGy.cm) with ICRP conversion coefficient "k" 0.015 [mSv / (mG. cm)]. Results: Mean age of patients was $49{\pm}18$ years with a male to female ratio of 35:28 (56%:44%). Median dose of 18FDG given was 194 MBq (range: 139-293). Median CTDIvol was 3.25 (2.4-6.2) and median DLP was 334.95 (246.70 - 576.70). Estimated median effective dose imparted by $^{18}FDG$ was 3.69 mSv (range: 2.85-5.57). Similarly the estimated median effective dose by low dose (non-diagnostic) CT examination was 4.93 mSv (range: 2.14 -10.49). Median total effective dose by whole body 18FDG PET plus low dose non-diagnostic CT study was 8.85 mSv (range: 5.56-13.00). Conclusions: We conclude that the median effective dose from a whole body 18FDG PET/CT in our patients was significantly low. We suggest adhering to recently published dose reducing strategies, use of ToF scanner with CT dose reducing option to achieve the lower if not the lowest effective dose. This would certainly reduce the risk of second primary malignancy in younger patients with higher odds of cure from first primary cancer.

Effect of Clinical Improvement of Schizophrenic Symptoms on $^{99m}Tc$-HMPAO Brain SPECT (정신분열병 환자의 임상적 증세 호전에 따른 $^{99m}Tc$-HMPAO 뇌 SPECT 소견의 변화)

  • Shin, Chul-Jin;Koong, Sung-Soo;Chung, In-Won
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.3
    • /
    • pp.310-319
    • /
    • 1997
  • This study investigated regional blood flow changes of frontal, temporal, and basal ganglia in eleven schizophrenic patients on DSM-IV criteria to examine the relationship between rCBF and clinical improvement of symptoms. Single-photon emission computed tomography imaging with $^{99m}Tc$-HMPAO was peformed in baseline and sixth weeks after the treatment, and concurrently psychopathology was assessed by PANSS. Antipsychotics wash-out period was more than 2 weeks, and three patient were drug naive. All patients were finally divided into two groups, the improved or not improved. We examined the difference of the amount of rCBF changes between two groups. Finally, frontal activity shows no significant difference between two groups but both groups show decreased frontal blood flow after antipsychotic treatment. However, the change of right temporal rCBF had positive correlation with the change of the total PANSS score, and the change of left temporal lobe activity was greater in the improved group than in the not improved group. Our results suggest that the temporal lobe activity has relation to the underlying schizophrenic symptoms.

  • PDF

A Comparative Study of Subset Construction Methods in OSEM Algorithms using Simulated Projection Data of Compton Camera (모사된 컴프턴 카메라 투사데이터의 재구성을 위한 OSEM 알고리즘의 부분집합 구성법 비교 연구)

  • Kim, Soo-Mee;Lee, Jae-Sung;Lee, Mi-No;Lee, Ju-Hahn;Kim, Joong-Hyun;Kim, Chan-Hyeong;Lee, Chun-Sik;Lee, Dong-Soo;Lee, Soo-Jin
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.3
    • /
    • pp.234-240
    • /
    • 2007
  • Purpose: In this study we propose a block-iterative method for reconstructing Compton scattered data. This study shows that the well-known expectation maximization (EM) approach along with its accelerated version based on the ordered subsets principle can be applied to the problem of image reconstruction for Compton camera. This study also compares several methods of constructing subsets for optimal performance of our algorithms. Materials and Methods: Three reconstruction algorithms were implemented; simple backprojection (SBP), EM, and ordered subset EM (OSEM). For OSEM, the projection data were grouped into subsets in a predefined order. Three different schemes for choosing nonoverlapping subsets were considered; scatter angle-based subsets, detector position-based subsets, and both scatter angle- and detector position-based subsets. EM and OSEM with 16 subsets were performed with 64 and 4 iterations, respectively. The performance of each algorithm was evaluated in terms of computation time and normalized mean-squared error. Results: Both EM and OSEM clearly outperformed SBP in all aspects of accuracy. The OSEM with 16 subsets and 4 iterations, which is equivalent to the standard EM with 64 iterations, was approximately 14 times faster in computation time than the standard EM. In OSEM, all of the three schemes for choosing subsets yielded similar results in computation time as well as normalized mean-squared error. Conclusion: Our results show that the OSEM algorithm, which have proven useful in emission tomography, can also be applied to the problem of image reconstruction for Compton camera. With properly chosen subset construction methods and moderate numbers of subsets, our OSEM algorithm significantly improves the computational efficiency while keeping the original quality of the standard EM reconstruction. The OSEM algorithm with scatter angle- and detector position-based subsets is most available.

Effect of Temperature on T1 and T2 Relaxation Time in 3.0T MRI (3.0T MRI에서 온도변화가 T1 및 T2 이완시간에 미치는 영향)

  • Kim, Ho-Hyun;Kwon, Soon-Yong;Lim, Woo-Teak;Kang, Chung-Hwan;Kim, Kyung-Soo;Kim, Soon-Bae;Baek, Moon-Young
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.15 no.2
    • /
    • pp.63-68
    • /
    • 2013
  • Purpose : The relaxation times of tissue in MRI depend on strength of magnetic field, morphology of nuclear, viscosity, size of molecules and temperature. This study intended to analyze quantitatively that materials' temperatures have effects on T1 and T2 relaxation times without changing of other conditions. Materials and Methods : The equipment was used MAGNETOM SKYRA of 3.0T(SIEMENS, Erlagen, Germany), 32 channel spine coil and Gd-DTPA water concentration phantom. To find out T1 relaxation time, Inversion Recovery Spin Echo sequences were used at 50, 400, 1100, 2500 ms of TI. To find out T2 relaxation time, Multi Echo Spin Echo sequences were used at 30, 60, 90, 120, 150, 180, 210, 240, 270 ms of TE. This experiment was scanned with 5 steps from 25 to $45^{\circ}C$. next, using MRmap(Messroghli, BMC Medical Imaging, 2012) T1 and T2 relaxation times were mapped. on the Piview STAR v5.0(Infinitt, Seoul, Korea) 5 steps were measured as the same ROI, and then mean values were calculated. Correlation between the temperatures and relaxation times were analyzed by SPSS(version 17.0, Chicago, IL, USA). Results : According to increase of temperatures, T1 relaxation times were $214.39{\pm}0.25$, $236.02{\pm}0.87$, $267.47{\pm}0.48$, $299.44{\pm}0.64$, $330.19{\pm}1.72$ ms. T2 relaxation times were $180.17{\pm}0.27$, $197.17{\pm}0.44$, $217.92{\pm}0.39$, $239.89{\pm}0.53$, $257.40{\pm}1.77$ ms. With the correlation analysis, the correlation coefficients of T1 and T2 relaxation times were statistically significant at 0.998 and 0.999 (p< 0.05). Conclusion : T1 and T2 relaxation times are increased as temperature of tissue goes up. In conclusion, we suggest to recognize errors of relaxation time caused local temperature's differences, and consider external factors as well in the quantitative analysis of relaxation time or clinical tests.

  • PDF