• Title/Summary/Keyword: Nuclear medicine $^{18}F-FDG$

Search Result 427, Processing Time 0.023 seconds

Clinical Application of $^{18}F-FDG$ PET in Nonmelanomatous Skin Cancer (비흑색종 피부암에서 $^{18}F-FDG$ PET의 임상 이용)

  • Yoon, Joon-Kee
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.sup1
    • /
    • pp.149-152
    • /
    • 2008
  • Nonmelanomatous skin cancer includes basal cell carcinoma, squamous cell carcinoma, merkel cell carcinoma and dermatofibrosarcoma protuberance. So far, there have been a few reports that $^{18}F-FDG$ PET was useful in the evaluation of metastasis and therapeutic response in nonmelanomatous skin cancer, however, those are very weak evidences. Therefore, further studies on the usefulness of $^{18}F-FDG$ PET in nonmelanomatous skin cancer are required.

Discrepancy of Bone Metastases between F-18 FDG PET/CT and Bone Scan in a Patient with Prostate Cancer (전립선암에서 골전이 진단에 대한 F-18 FDG PET/CT와 골스캔의 불일치)

  • Choi, Seung-Jin;Kim, Chul-Soo;Byun, Sung-Su;Hyun, In-Young
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.5
    • /
    • pp.275-278
    • /
    • 2006
  • We report the case of a 73-year-old man who had prostate cancer with bone metastases. Tc-99m HDP Whole body bone scan revealed multiple areas of increased bony uptake consistent with widespread bone metastases. F-18 fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) demonstrated mild F-18 FDG uptake in the lymph nodes of neck, abdomen, and pelvis. However, abnormal F-18 FDG uptake was not seen in the skeletal system. Biopsy and immunohistochemical stains of left supraclavicular mass showed metastatic prostate adenocarcinoma. Currently, there are a few reported cases of F-18 FDG PET/CT evaluation of bone metastases in prostate cancer. We discuss the discrepancy between F-18 FDG PET/CT and bone scan in the detection of osseous metastases of prostate cancer.

Clinical Application of $^{18}F-FDG$ PET in Salivary Gland Cancer (타액선암(Salivary Gland Cancer)에서 $^{18}F-FDG$ PET의 임상 이용)

  • Yang, You-Jung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.sup1
    • /
    • pp.14-16
    • /
    • 2008
  • Salivary gland tumors are relatively rare, constituting 3% of all head and neck neoplasms. In patients with salivary gland malignancies, $^{18}F-FDG$ PET is clinically useful in initial staging, histologic grading, and monitoring after treatment. According to clinical research data hitherto, $^{18}F-FDG$ PET is expected to be an effective diagnostic tool in the management of salivary gland tumors.

A Case of Incidentally Detected Nasopharyngeal Tuberculosis on F-18 FDG PET/CT (F18-FDG PET/CT에서 우연히 발견된 비인두 결핵 1예)

  • Lee, Jai-Hyuen;Kim, Jae-Seung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.6
    • /
    • pp.482-484
    • /
    • 2008
  • It is well known that F18-FDG PET/CT is a highly sensitive diagnostic modality for cancer patients. However, false positive cases resulting from benign disease such as tuberculosis in the endemic area often compromise the diagnostic accuracy of F18-FDG PET/CT. Nasopharyngeal tuberculosis is a rare disease although extrapulmonary tuberculosis can involve any region in the body. We report one case of nasopharyngeal tuberculosis incidentally detected on F18-FDG PET/CT.

Clinical Application of $^{18}F$-FDG PET in Multiple Myeloma (다발성 골수종에서의 $^{18}F$-FDG PET의 임상이용)

  • Lee, Su-Jin;Choi, Joon-Young
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.6
    • /
    • pp.509-512
    • /
    • 2009
  • This review focuses on the clinical use of $^{18}F$-FDG PET to evaluate multiple myeloma. $^{18}F$-FDG PET is useful for diagnosis, staging of multiple myeloma and differential diagnosis of myeloma related disease such as monoclonal gammopathy of undetermined significance or plasmacytoma. For therapy response, $^{18}F$-FDG PET may be effective after chemotherapy for multiple myeloma and radiotherapy for plasmacytoma.

Improved Radiochemical Yields, Reliability and Improvement of Domestic $^{18}F$-FDG Auto Synthesizer (국산 $^{18}F$-FDG Auto Sysnthesizer의 수율 향상과 성능 개선)

  • Park, Jun-Hyung;Im, Ki-Seop;Lee, Hong-Jin;Jeong, Kyung-Il;Lee, Byung-Chul;Lee, In-Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.147-151
    • /
    • 2009
  • Purpose: 2-[$^{18}F$]Fluoro-2-deoxy-D-glucose ([$^{18}F$]FDG) particularly plays as a important role in Positron Emission Tomography (PET) imaging in nuclear medicine. Domestic [$^{18}F$]FDG auto synthesizers are installed in Seoul National University Bundang Hospital (SNUBH) at June 2008, these modules were known that it's synthetic yields were guaranteed in average $45{\pm}5%$ so far. To improve yields and convenience of domestic [$^{18}F$]FDG auto synthesizer, numerous trials in reaction time, base concentration, pressure and temperature were performed to increase [$^{18}F$]FDG yields. Materials and Methods: Several synthetic factors (temperature, time and pressure) and shortcoming were corrected based on many evaporation test. Syringe dispensing of tetra-butylammonium bicarbonate (TBAB) was replaced with micro pipette to prepare tetrabutyl ammonium fluoride salt ([$^{18}F$]TBAF). Troublesome refill of liquid nitrogen every 2 hours which was used to protect vacuum system was changed to charcoal cartridge, base guard filter. To monitor the volume of delivered $[^{18}O]OH_2$ from cyclotron by surveillance camera, we set up the volumetric vial on the cover of the module. In addition to, the recovery vial was added in [$^{18}F$]FDG production system to recover [$^{18}F$]FDG loss due to the leak of valve ($V_{13,14}$) in [$^{18}F$]FDG purification process. Results: When we used micro pipette for adding TBAB ($30\;{\mu}L$ in 12% $H_2O$ in acetonitrile), this quantitative dispensation has enabled to improve $5.5{\pm}1.7%$ residual fluorine-18 activity in fluorine separation cartridge compared to syringe adding. Besides, the synthetic yields of [$^{18}F$]FDG has increased $58{\pm}2.6%$ (n=19), $58{\pm}2.9%$ (n=14), $60%{\pm}2.5%$ (n=17) for 3 months. The life cycle of charcoal cartridge and base vacuum was 3 months prior to filling liquid nitrogen every 2 hours and additional side separator can prevent pump corrosion by organic solvent. After setting of volumetric indicator vial, the operator can easily monitor the total volume of irradiated $[^{18}O]OH_2$ from cyclotron. The recovery vial can be used for the stabilizer when an irregular [$^{18}F$]FDG loss was generated by the leak of valves ($V_{13,14}$). Conclusions: We has optimized appropriate synthetic conditions (temperature, time, pressure) in domestic [$^{18}F$]FDG auto synthesizer. In addition to, the remodeling with several accessories improve yields of domestic [$^{18}F$]FDG auto synthesizer with reliable reproducibility.

  • PDF

Clinical Application of $^{18}F-FDG$ PET in Breast Cancer (유방암에서 $^{18}F-FDG$ PET의 임상 이용)

  • Yoon, Joon-Kee
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.sup1
    • /
    • pp.76-90
    • /
    • 2008
  • $^{18}F-FDG$ PET in combination with conventional imaging modalities could help avoid unnecessary biopsy for the primary mass, and it also has a high diagnostic accuracy in patients with dense breasts. In the assessment of metastasis, $^{18}F-FDG$ PET was useful to select patients who required sentinel lymph node biopsy and to detect extra-axillary lymph node metastasis and distant metastasis. To increase the sensitivity for osteoblastic bone metastasis, bone scintigraphy should be added. In the detection of recurrence, $^{18}F-FDG$ PET showed a higher diagnostic accuracy than tumor marker or computed tomography, and therefore it can be used in routine breast cancer follow-up. $^{18}F-FDG$ PET has been reported that it correctly predicted the response of neoadjuvant chemotherapy on as early as 8th day of treatment. Therefore, it is useful for the early detect of therapeutic response in advanced breast cancer.

Clinical Application of $^{18}F-FDG$ PET in Small Cell Lung Cancer (소세포폐암에저의 $^{18}F-FDG$ PET의 임상 이용)

  • Choi, Joon-Young
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.sup1
    • /
    • pp.29-31
    • /
    • 2008
  • This review focuses on the clinical use of $^{18}F-FDG$ PET in small cell lung cancer. For initial staging of small cell lung cancer, $^{18}F-FDG$ PET appears to be better than conventional staging methods. $^{18}F-FDG$ PET seems to be potentially useful for detecting recurrence, restaging and therapy response assessment in small cell lung cancer. However, due to small number of literatures, the role of $^{18}F-FDG$ PET in small cell lung cancer requires further investigations.

Non-specific Inflammatory Disease Showed Abnormal FDG Uptake in Lower Extremities ($^{18}F-FDG$ PET/CT 에서 하지골 골수에 다발성 이상섭취를 보인 비특이성 염증성질환)

  • Chun, Kyung-Ah;Kong, Eun-Jung;Cho, Ihn-Ho;Hong, Young-Hoon;Lee, Choong-Ki
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.1
    • /
    • pp.79-80
    • /
    • 2008
  • Including malignancy, various disease can show abnormal uptake in bone marrow. We report a case of non-specific inflammatory FDG uptake in bone marrow mimicking malignancy. A 35-year old woman with fever of unknown origin (FUO) underwent $^{18}F$-FDG PET/CT to find out fever $^{18}F$-FDG and unknown malignancy. $^{18}F$-FDG was injected and imaged 1hr after injection with Discovery ST (GE, USA), $^{18}F$-FDG PET/CT whole body image showed abnormal uptake in lower extremities (Fig. 1). MRI and biopsy was also done in the sites of abnormal uptake. PET and MRI suspect malignancy (Fig. 2, 3), but biopsy result was non-specific inflammatory process (Fig. 4). The patient was improved her clinical condition after antibiotics therapy.