• 제목/요약/키워드: Nuclear incident

검색결과 152건 처리시간 0.027초

원자력 발전소의 방재 대책 (FIRE SAFETY IN NUCLEAR POWER STATIONS)

  • 김동석
    • 방재기술
    • /
    • 통권10호
    • /
    • pp.27-33
    • /
    • 1991
  • The chernobyl disaster, the most serious and recent incident at an atomic plant, focussed worldwide attention on the danger of nuclear power. In this article, We discuss the fire hazards in nucleer power stations and some of the precautions necessary. Also this deals with each of the reactor components in turn, and the examples of incidents in the nuclear power stations are briefty discribed.

  • PDF

비수직 입사 비상관 지진파에 의한 원전 시설물의 지진 응답 (Earthquake Responses of Nuclear Facilities Subjected to Non-vertically Incidental and Incoherent Seismic Waves)

  • 이진호
    • 한국지진공학회논문집
    • /
    • 제26권6호
    • /
    • pp.237-246
    • /
    • 2022
  • Based on the random-vibration-theory methodology, dynamic responses of nuclear facilities subjected to obliquely incidental and incoherent earthquake ground motions are calculated. The spectral power density functions of the 6-degree-of-freedom motions of a rigid foundation due to the incoherent ground motions are obtained with the local wave scattering and wave passage effects taken into consideration. The spectral power density function for the pseudo-acceleration of equipment installed on a structural floor is derived. The spectral acceleration of the equipment or the in-structure response spectrum is then estimated using the peak factors of random vibration. The approach is applied to nuclear power plant structures installed on half-spaces, and the reduction of high-frequency earthquake responses due to obliquely incident incoherent earthquake ground motions is examined. The influences of local wave scattering and wave passage effects are investigated for three half-spaces with different shear-wave velocities. When the shear-wave velocity is sufficiently large like hard rock, the local wave scattering significantly affects the reduction of the earthquake responses. In the cases of rock or soft rock, the earthquake responses of structures are further affected by the incident angles of seismic waves or the wave passage effects.

A Revisit to the Recent Human Error Events in Nuclear Power Plants Focused to the Organizational and Safety Culture

  • Lee, Yong-Hee
    • 대한인간공학회지
    • /
    • 제32권1호
    • /
    • pp.117-124
    • /
    • 2013
  • Objective: This paper presents additional considerations related to organization and safety culture extracted from recent human error incidents in Korea, such as station blackout(i.e., SBO) in Kori#1. Background: Safety culture has been already highlighted as a major cause of human errors after 1986 Chernobyl accident. After Fukushima accident in Japan, the public acceptance for nuclear energy has taken its toll. Organizational characteristics and culture became elucidated as a major contributor again. Therefore many nuclear countries are re-evaluating their safety culture, and discussing any preparedness and its improvement. On top of that, there was an SBO in 2012 in the Kori#1. Korean public feels frustrated due to the similar human errors causing to a catastrophe like Fukushima accident. Method: This paper reassesses Japan's incidents, and revisits Korea's recent incidents. It focuses on the analysis of the hazards rather than the causes of human errors, the derivation of countermeasures, and their implementation. The preceding incidents and conclusions from Japanese experience are also re-analyzed. The Fukushima accident was an SBO due to the natural disaster such as earthquakes and a successive tsunami. Unlike the Fukushima accident, the Kori#1 incident itself was simple and restored without any loss and radioactive release. However, the fact that the incident was deliberately concealed led to massive distrust. Moreover, the continued violation of rules and organized concealment of the accident are serious signs of a new distorted type of human errors, blatantly revealing the cultural and fundamental weakness of the current organization. Result: We should learn from Japanese experiences who had taken pride in its safety technology and fairly high confidence in safety culture. Japan's first criticality accident in JCO facility splashed cold water on that confidence. It has turned out to be a typical case revealing the problems in the organization and safety culture. Since Japan has failed to gain lessons and countermeasure, the issue persists to the Fukushima incident. Conclusion: Safety culture is not a specific independent element, which makes it difficult to either evaluate it properly or establish countermeasures from the lessons. It may continue to expose similar human errors such as concealment of incident and manipulation of bad data. Application: Not only will this work establish the course of research for organization and safety culture, but this work will also contribute to the revitalization of Korea's nuclear industry from the disappointment after the export contract to UAE.

Comparison of Alpha Particle Signals with respect to Incident Direction onto n-Si:H pin diodes

  • Kim, Ho-Kyung;Gyuseong Cho;Hur, Woo-Sung;Lee, Wanno;Hong, Wan-Shick
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(4)
    • /
    • pp.133-138
    • /
    • 1996
  • For the application of hydrogenated amorphous silicon (a-Si:H) p-i-n structural diode as the alpha particle spectroscopy, the induced charge collection was simulated based on a relevant non-uniform charge generation model. The simulation was accomplished for two extreme cases of the incident direction of alpha particle, p-and n-side, respectively. As expected, for the complete charge collection, the hole collection should be severely considered due to its poor mobility and the full depletion bias required. For the comparison of signal corresponding to the detector configuration or structure, although n-i-p configuration shows a wider range of linearity to the energy, p-i-n configuration is more suitable in the viewpoint of linearity and signal value for the considering energy range.

  • PDF

배양세포의 성염색질에 관한 세포학적 연구 1. 배양기간을 달리한 고양이, 몰못트, 닭의 배양세포에 있어서의 성염색질에 대하여

  • 강영선;박상대
    • 한국동물학회지
    • /
    • 제8권2호
    • /
    • pp.37-41
    • /
    • 1965
  • The frequency and pattern of sex chromatin in primary cultured cells of kidney cortex of cats and guinea-pigs, and muscle of chick embroys were examined and compared to those of in vivo condition, with special reference to the various cultured stages. 1. In cat, the frequencies of sex chromatin positive I of peripheral position were average 62.7% in female, and 15% in male, whereas those of non-peripherla position were 5.8% in female and 0.1% in male. The incident proportion between them showed a marked difference-approximately 10 times higher in female than male. These results failry indicated that a distinct nuclear dimorphism with regard to the sex chromatin positive I was established in cultured cells. The position of sex chormatin was usually peripheral location. The tendency of frequencies , with reference to the cultured stages, was low count in primary extracted and initial stage cells , but it showed a peaked frequency in 10-13 days after primary culture, and after that the frequencies were decreased gradually. Compared between I vitro and in vivo condition of the same tissues, the cells in vivo exhibited the sex chromatin in high frequency at the peak showed stage. 2. In guinea-pig , the frequencyies of peripheral positive I were 36.8% in female and 6.3% in male, while non-peripheral positions were 6.1% in female and 3.5% inmale. Its incident was a rate of nearly 4 times higher in female than male. The nuclear dimorphism was also established in cultrued cells of guinea-pig. The position and the incident frquency showed a similar pattern as in cat except the primary extracted cells. 3. In chick embryo, the frequencies of sex chromatin positive I of peripheral position were 38.2% in female, and 18.3% in male, non-peripheral position, however, was hardly to find. These results suggest that the definite sexual dimorphism was unable to find in chick embryo cultured cells. The position and the incident tendency were a similar pattern as in above mammals and the frequency was higher in vitro cells.

  • PDF

Post-Fukushima Reforms within the Japanese Nuclear Power Sector

  • Han, Heejin;Chin, Olivia Ying Lin;Tan, Rou Jing;Koh, Clarissa Cai Lin;Kemal, Mohammad
    • STI Policy Review
    • /
    • 제4권1호
    • /
    • pp.119-134
    • /
    • 2013
  • The Fukushima nuclear incident of 2011 served as an external shock that prompted Japan to reform its nuclear energy sector. The collusive relationship between the regulators within the Japanese government and the regulated power industry, as well as the lack of institutional independence of the regulatory agency, had derailed Japanese efforts to reform the sector for decades. The Fukushima crisis exposed these deeply-entrenched flaws in the system, causing public distrust and anger toward the government and the nuclear power sector. This paper discusses the institutional reform measures the Japanese government introduced in the wake of the Fukushima crisis to recover public confidence and revamp the sector to prevent future disasters. The paper also discusses the challenges the Japanese government faces on its road to a successful implementation of nuclear sector reforms.

An inter-comparison between ENDF/B-VIII.0-NECP-Atlas and ENDF/B-VIII.0-NJOY results for criticality safety benchmarks and benchmarks on the reactivity temperature coefficient

  • Kabach, Ouadie;Chetaine, Abdelouahed;Benchrif, Abdelfettah;Amsil, Hamid
    • Nuclear Engineering and Technology
    • /
    • 제53권8호
    • /
    • pp.2445-2453
    • /
    • 2021
  • Since the nuclear data forms a vital component in reactor physics computations, the nuclear community needs processing codes as tools for translating the Evaluated Nuclear Data Files (ENDF) to simulate nuclear-related problems such as an ACE format that is used for MCNP. Errors, inaccuracies or discrepancies in library processing may lead to a calculation that disagrees with the experimentally measured benchmark. This paper provides an overview of the processing and preparation of ENDF/B-VIII.0 incident neutron data with NECP-Atlas and NJOY codes for implementation in the MCNP code. The resulting libraries are statistically inter-compared and tested by conducting benchmark calculations, as the mutualcomparison is a source of strong feedback for further improvements in processing procedures. The database of the benchmark experiments is based on a selection taken from the International Handbook of Evaluated Criticality Safety Benchmark Experiments (ICSBEP handbook) and those proposed by Russell D. Mosteller. In general, there is quite good agreement between the NECP-Atlas1.2 and NJOY21(1.0.0.json) results with no substantial differences, if the correct input parameters are used.