• 제목/요약/키워드: Nuclear data library

검색결과 73건 처리시간 0.039초

Development of multigroup cross section library generation system TPAMS

  • Lili Wen;Haicheng Wu;Ying Chen;Xiaoming Chai;Xiaofei Wu;Xiaolan Tu;Yuan Liu
    • Nuclear Engineering and Technology
    • /
    • 제56권6호
    • /
    • pp.2208-2219
    • /
    • 2024
  • Kylin-2 is an advanced neutronics lattice code, developed by Nuclear Power Institute of China. High-precision multigroup cross section library is need for KYLIN-2 to carry out simulation of current pressurized water reactor (PWR) and advanced reactor. In this paper a multigroup cross section library generation system named TPAMS was developed, the methods in TPAMS dealing with resonance data such as subgroup parameters, lambda factor, resonance integral were discussed. Moreover, the depletion chain simplification method was studied. TPAMS can produce multigroup library in binary and ASIIC formats, including detailed data contents for resonance, transport and depletion calculations. A multigroup cross section library has been generated for KYLIN-2 based on TPAMS system. The multigroup cross section library was verified through the analysis of various criticality and burnup benchmarks, the values of multiplication factor and isotope density were compared with the experiment data. Numerical results demonstrate the accuracy of the multigroup cross section library and the reliability of the multigroup cross section library generation system TPAMS.

NEUTRON CROSS SECTION DATA LIBRARY FOR PD-105, AG-109, XE-131 AND CS-133

  • LEE Y. D.;CHANG J. H.
    • Nuclear Engineering and Technology
    • /
    • 제37권1호
    • /
    • pp.101-108
    • /
    • 2005
  • The neutron induced nuclear cross-section data for Pd-105, Ag-109, Xe-131, and Cs-133 were calculated and evaluated from an unresolved energy to 20 MeV. The energy dependent optical model potential parameters were extracted based on recent experimental data and applied up to 20 MeV. A spherical optical model and a statistical model for the equilibrium energy, and a multistep direct and a multistep compound model for the pre-equilibrium energy were used in the calculation. The direct capture model was recently introduced for fast neutron capture. The theoretically calculated cross-sections were compared with the experimental data and the evaluated files. The total and capture cross-sections calculated using the model were in good agreement with the reference experimental data. The evaluated cross-section results were compiled in ENDF-6 format and merged with the resonance component, already adopted in the ENDF/B-VI release 8. New data library files covering from thermal to 20 MeV were created. They are at the preliminary stage of an ENDF/B- VII release.

Processing and benchmarking of evaluated nuclear data file/b-viii.0β4 cross-section library by analysis of a series of critical experimental benchmark using the monte carlo code MCNP(X) and NJOY2016

  • Ouadie, Kabach;Abdelouahed, Chetaine;Abdelhamid, Jalil;Abdelaziz, Darif;Abdelmajid, Saidi
    • Nuclear Engineering and Technology
    • /
    • 제49권8호
    • /
    • pp.1610-1616
    • /
    • 2017
  • To validate the new Evaluated Nuclear Data File $(ENDF)/B-VIII.0{\beta}4$ library, 31 different critical cores were selected and used for a benchmark test of the important parameter keff. The four utilized libraries are processed using Nuclear Data Processing Code (NJOY2016). The results obtained with the $ENDF/B-VIII.0{\beta}4$ library were compared against those calculated with ENDF/B-VI.8, ENDF/B-VII.0, and ENDF/B-VII.1 libraries using the Monte Carlo N-Particle (MCNP(X)) code. All the MCNP(X) calculations of keff values with these four libraries were compared with the experimentally measured results, which are available in the International Critically Safety Benchmark Evaluation Project. The obtained results are discussed and analyzed in this paper.

열중성자로 핵계산을 위한 69군 단면적 라이브러리 생산 및 검증 (Generation and Benchmarking of a 69-group Cross Section Library for Thermal Reactor Applications)

  • Kim, Jung-Do;Lee, Jong-Tai;Gil, Choong-Sup;Kim, Hark-Rho
    • Nuclear Engineering and Technology
    • /
    • 제21권4호
    • /
    • pp.245-258
    • /
    • 1989
  • 열중성자로의 핵계산을 위한 69군 단면적 라이브러리를 생산하였다. 기본 평가핵자료로는 IAEA Nuclear Data Section에서 수집된 자료가, 그리고 이를 처리하여 군정수화 하는데는 NJOY코드가 이용되었다. 새로이 마련된 라이브러리의 유용성을 검증하기 위해 각기 산화우라늄과 금속 우라늄 연료로 구성된 임계실험치를 WIMS-KAERI 코드로 계산된 결과와 비교, 검토하였다. 총 88임계결과에 대해 평균 $K_{eff}$ 값 0.9997, 그리고 표준 편차 0.69%를 보였다. PWR 연료의 연소결과로 얻어진 우라늄과 플루토늄 생성량에 대한 평가에서도 전반적으로 좋은 결과를 얻었다.다.

  • PDF

Effect of the new photoatomic data library EPDL2017 to mass attenuation coefficient calculation of materials used in the nuclear medicine facilities using EpiXS software

  • Jecong, J.F.M.;Hila, F.C.;Balderas, C.V.;Guillermo, N.R.D.
    • Nuclear Engineering and Technology
    • /
    • 제54권9호
    • /
    • pp.3440-3447
    • /
    • 2022
  • The accuracy of the photoatomic cross-section data is of great importance in the field of radiation protection, particularly in the characterization of radiation shielding materials. With the release of the latest and probably the most accurate photoatomic data library, EPDL2017, the need to re-evaluate all the existing and already established mass attenuation coefficients (MACs) of all radiation shielding materials arises. The MACs of several polymers, alloy-based, glasses, and building materials used in a nuclear medicine facility were investigated using the EPDL2017 library embedded in EpiXS software and were compared to MACs available in the literature. The relative differences between MACEpiXS and MACXCOM were negligible, ranging from 0.02% to 0.36% for most materials. However, for material like a glass comprising of elements Te and La evaluated near their corresponding K-edge energies, the relative differences in MACs increased up to 1.46%. On the other hand, a comparison with MACs calculated based on EPDL97 (a predecessor of EPDL2017) revealed as much as a 6.61% difference. Also, it would seem that the changes in MACs were more evident in the materials composed of high atomic number elements evaluated at x-ray energies compared to materials composed of low atomic number elements evaluated at gamma-ray energies.

SNU Experience with ENDF Processing by NJOY

  • 이정훈;김창효
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1995년도 추계학술발표회논문집(1)
    • /
    • pp.67-72
    • /
    • 1995
  • 최근 선진 원자력 개발국들이 새로운 평가 핵자료집들을 계속하여 공개하고 있다. 이 핵자료들을 노심 채석에 적용하기 위한 연구의 일환으로 최근에 발표된 ENDF/B-V1.2 평가 핵자료집을 이용하여 CASMO-3의 단면적 Data Library를 만들어 검증해 보았다. 평가 핵자료집의 개선 정도와 계산상으로 만들어진 Library와 실제 사용되는 Library의 차이를 알아보기 위하여 BNDF/B-IV도 같이 처리하여 검증하였다. 유효증배계수와 integral parameter들을 비교한 결과 ENDF/B-VI의 유용성과 일관성이 입증되었고, 단면적 Library의 수정 작업에 관한 연구의 필요성도 제기되었다.

  • PDF

Influence of nuclear data library on neutronics benchmark of China experimental fast reactor start-up tests

  • Guo, Hui;Jin, Xin;Huo, Xingkai;Gu, Hanyang;Wu, Haicheng
    • Nuclear Engineering and Technology
    • /
    • 제54권10호
    • /
    • pp.3888-3896
    • /
    • 2022
  • Nuclear data is the basis of reactor physics analysis. This paper aim at studying the influence of major evaluated nuclear data libraries, CENDL-3.2, ENDF/B-VIII.0, JEFF-3.3, and JENDL-4.0u, on the neutronics modelling of CEFR start-up tests. Results show these four libraries have a good performance and consistency in the modelling CEFR start-up tests. The JEFF-3.3 results exhibit only an 8 pcm keff difference with the measurement. The difference in criticality is decomposed by nuclide, which shows the large overestimation of CENDL-3.2 is mainly from the cross-section of 52Cr. Except for few cases, the calculation results are within 1σ of measurement uncertainty in control rod worth, sodium void reactivity, temperature reactivity, and subassembly swap reactivity. In the evaluation of axial and radial reaction distribution, there are about 65% of relative errors that are less than 5% and 82% of relative errors that are less than 10%.