• 제목/요약/키워드: Nozzle penetration

검색결과 131건 처리시간 0.019초

GDI 와류 분사노즐에 의한 비증발 분무의 가시화 및 수치해석 (Visualization and Numerical Analysis of Non-evaporating Spray with a Swirl-Type GDI Injector)

  • 원영호;강수구
    • 한국자동차공학회논문집
    • /
    • 제11권4호
    • /
    • pp.22-28
    • /
    • 2003
  • Predictions of the fuel spray dispersion and mixing processes are very important to improve the fuel consumption and exhaust emissions in GDI engines. Numerical and experimental analysis of the sprays with a swirl injector have been conducted. A numerical analysis is carried out using KIVA-II code with modified spray models. Experimental measurements are performed to show the global spray images and the local images near nozzle tip using laser sheet visualization technique. Computed and measured spray characteristics such as spray width, tip penetration are compared, and good agreements can be achieved. The spray head vortex is stronger as the injection pressure increases, but numerical calculations cannot show the head vortex properly.

가솔린 분무 거동에 미치는 분위기 조건의 영향 (Effect of Ambient Conditions on Spray Behavior of Gasoline Injector)

  • 이창식;이기형;최수천;권상일
    • 한국자동차공학회논문집
    • /
    • 제8권2호
    • /
    • pp.27-32
    • /
    • 2000
  • The main objective of this work is to investigate the effect of ambient conditions on the spray behavior and spray characteristics of high-pressure fuel injector. For this purpose, the effects of ambient pressure and temperature on the spray characteristics have been studied by applying the analysis of visualization system and phase Doppler particle analyzer. In this experiment, the visualization of spray behavior was performed under various ambient gas conditions and injection parameters such as gas temperature, ambient pressure, injection pressure of injector, and axial distance from the nozzle tip. Based on the investigation results, the spray tip penetration and spray width decrease with the increase of ambient gas pressure in the spray chamber. The effects of the spray parameters on the microscopic characteristics of gasoline spray were discussed.

  • PDF

원자력발전 고방사선구역 소구경 노즐에 대한 자동화검사 기술 (Automatic Inspection Technology for Small Bore Penetration Nozzle in High Radiation Area of Nuclear Power Plant)

  • 류승우;윤기봉;전규민;성운학
    • 비파괴검사학회지
    • /
    • 제36권6호
    • /
    • pp.504-509
    • /
    • 2016
  • 원자력발전소의 노후화에 따른 이종금속용접부에서 결함 발생 사례가 지속적으로 보고되고 있으며, 국내에서도 원자력발전소 가동연수 증가에 따라 이종금속부에 결함 발생도 점점 증가할 것으로 판단된다. 국내에서는 증기발생기 배수 노즐 이종금속용접부, 원자로냉각재계통(RCS) 고온관 시료 채취 노즐에서 결함 사례가 보고되었고, 원자력발전소의 인력 접근이 제한적인 고방사선구역 내 소구경 노즐의 이종금속용접부에 대한 검사 시 인력 투입을 최소화 하는 신뢰성 있는 자동화 비파괴검사 가능 기술 및 시스템 개발 필요성이 증대되고 있다. 본 연구에서는 원자력발전소의 소구경 노즐 결함 검출을 위해 1) beam simulation을 통한 최적 검사 탐촉자 설계, 2) 소구경 이종용접부 검사용 multi-directions UT 최적 검사기술, 3) 원격제어 automatic inspection system을 개발하였으며, 표준결함시편을 이용하여 개발된 기술 및 시스템의 결함 검출능을 검증하였다. 개발된 최적기술과 시스템은 실제 발전소에서 발생된 결함 (RCS 고온관 시료 채취 노즐)에 대한 검사에 적용하여 결함을 검출함으로써 개발 검사 기술 및 시스템의 적합성이 검증되었다. 개발된 기술은 원전의 다양한 소구경 건전성 평가에 활용함으로써 원자력발전 안전성 확보에 기여할 수 있을 것으로 기대된다.

이중 콘형 부분예혼합 GT 연료노즐의 연소특성 및 발전플랜트 실증 (Combustion Characteristics and On-site Performance Test of a Double-cone Partial Premixed Nozzle with Various Fuel hole Patterns)

  • 김한석;조주형;김민국;황정재;이원준;민경욱;강도원
    • 한국가스학회지
    • /
    • 제25권6호
    • /
    • pp.22-28
    • /
    • 2021
  • 발전용 가스터빈에 사용되는 이중 콘형 예혼합 연소기의 성능 개선 및 검증을 위하여 기존 노즐에서 연료 분사 특성을 개선한 노즐(분사구 직경 증가, 분사구 수 감소, 총 분사면적 유지)을 이용하여 고압 및 다중화염 조건에서 실험 연구를 수행하였으며 배기가스 특성을 기존 노즐과 비교하였다. 실험 결과로는 노즐의 연료 직경을 크게 한 경우 연소용 공기로 연료의 침투 거리가 증가하기 때문에 콘 내부에서 연료와 공기의 혼합특성이 개선되어 상압뿐만 아니라 압력 상승 시 NOx 배출 농도는 감소하며 다중 화염의 경우 화염간 연소영역의 중첩이 감소하게 되어 NOx 배출은 감소하지만 화염 안정성은 저하된다. 연료 분사구를 개선한 노즐의 발전 플랜트 실증 결과는 실험 결과와 같이 기존 노즐에 비하여 NOx 농도가 낮게 배출되었다.

Corium melt researches at VESTA test facility

  • Kim, Hwan Yeol;An, Sang Mo;Jung, Jaehoon;Ha, Kwang Soon;Song, Jin Ho
    • Nuclear Engineering and Technology
    • /
    • 제49권7호
    • /
    • pp.1547-1554
    • /
    • 2017
  • VESTA (Verification of Ex-vessel corium STAbilization) and VESTA-S (-small) test facilities were constructed at the Korea Atomic Energy Research Institute in 2010 to perform various corium melt experiments. Since then, several tests have been performed for the verification of an ex-vessel core catcher design for the EU-APR1400. Ablation tests of an impinging $ZrO_2$ melt jet on a sacrificial material were performed to investigate the ablation characteristics. $ZrO_2$ melt in an amount of 65-70 kg was discharged onto a sacrificial material through a well-designed nozzle, after which the ablation depths were measured. Interaction tests between the metallic melt and sacrificial material were performed to investigate the interaction kinetics of the sacrificial material. Two types of melt were used: one is a metallic corium melt with Fe 46%, U 31%, Zr 16%, and Cr 7% (maximum possible content of U and Zr for C-40), and the other is a stainless steel (SUS304) melt. Metallic melt in an amount of 1.5-2.0 kg was delivered onto the sacrificial material, and the ablation depths were measured. Penetration tube failure tests were performed for an APR1400 equipped with 61 in-core instrumentation penetration nozzles and extended tubes at the reactor lower vessel. $ZrO_2$ melt was generated in a melting crucible and delivered down into an interaction crucible where the test specimen is installed. To evaluate the tube ejection mechanism, temperature distributions of the reactor bottom head and in-core instrumentation penetration were measured by a series of thermocouples embedded along the specimen. In addition, lower vessel failure tests for the Fukushima Daiichi nuclear power plant are being performed. As a first step, the configuration of the molten core in the plant was investigated by a melting and solidification experiment. Approximately 5 kg of a mixture, whose composition in terms of weight is $UO_2$ 60%, Zr 10%, $ZrO_2$ 15%, SUS304 14%, and $B_4C$ 1%, was melted in a cold crucible using an induction heating technique.

3가지 니들구동방식별 CRDi 디젤엔진용 고압 인젝터의 거시적 분무특성 비교해석 (Analysis of Macroscopic Spray Characteristics of Diesel Injectors with Three Different Needle Driving Type in Common Rail Direct Injection System)

  • 이진욱;민경덕
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권3호
    • /
    • pp.351-358
    • /
    • 2006
  • The capability of high pressure injection with small fuel quantify at all engine operating conditions is one of the main feature in common rail fuel injection system, which is used in small and light-duty Diesel engine. The key parameter for the better atomized fuel sprays and multiple injections of this common rail fuel injection control, that can be freely selected irrespective of the engine speed and load is the mechanism controlling the needle energizing and movement in high pressure Diesel injector. In the electro-hydraulic injector, the injection nozzle is being opened and closed by movement of the injector's needle which is balanced by pressure between the nozzle seat and the needle control chamber. This study describes the macroscopic spray structure characteristics of the common rail Diesel injectors with different electric driving method i.e. the solenoid-driven and piezo-driven type. The macroscopic spray characteristics such as spray tip speed. spray tip penetration and spray cone angle were investigated by the high speed spray, which is measured by the back diffusion light illumination method with optical system for the high speed temporal photography in a constant volume chamber pressurized by nitrogen gas. As the results, the prototype piezo-driven injector system was designed and fabricated for the first time in domestic case and the effect of injector's needle response driven by different drive type was compared between the solenoid and piezo-driven injector It was found therefore. that the piezo-driven injector showed faster needle response and had better needle control capability by altering the electric input value than the solenoid-driven injector.

원전 이종금속 맞대기용접부 PWSCC 균열건전성평가 (Evaluation of PWSCC at Dissimilar Metal Butt Welds in NPP)

  • 이성호;이경수;오창영
    • 대한기계학회논문집A
    • /
    • 제36권9호
    • /
    • pp.1047-1052
    • /
    • 2012
  • 가압경수로형 원전의 Alloy 600 원자로압력용기헤드 관통노즐 및 Alloy 82/182 이종금속 맞대기 용접부에서 일차수응력부식균열(PWSCC)이 보고된 이후 전 세계적으로 PWSCC에 의한 용접부 파단을 예방하기 위해 강화검사를 적용하고 있다. 본 이종금속용접부에 대한 가동중검사에서 균열이 발견된 경우 건전성평가 결과가 도출되기까지 발전소가 정지 상태에 있게 됨에 따라 원전 이용율 저하가 발생할 수 있는데, 이를 예방하기 위해서는 균열건전성평가 관련 기술의 정립뿐만 아니라 신속하게 평가 결과를 도출할 수 있는 시스템의 구축이 필요하다. 본 연구에서는 이종금속 맞대기 용접부를 대상으로 진행하고 있는 PWSCC 균열건전성평가 기준 정립 및 전산 시스템 개발 결과를 제시하였다. 본 연구를 통해 이종금속 맞대기 용접부 PWSCC 균열건전성평가 기술이 정립되고 전산 시스템으로 구현되어 원자로압력용기 주변 이종금속 맞대기 용접부에서의 PWSCC 균열에 대한 기술적 건전성평가 수단을 확보하였다.

용융염-액체금속 계의 대용물인 물-수은 계에서 액체금속 액적의 생성에 대한 연구 (A Study on the Droplet Formation of Liquid Metal in Water-Mercury System as a Surrogate of Molten Salt-Liquid Metal System at Room Temperature)

  • 김용일;박병기
    • 방사성폐기물학회지
    • /
    • 제16권2호
    • /
    • pp.165-172
    • /
    • 2018
  • 용융염-액체금속 추출공정에서 형성되는 액적 크기를 추정하는 방안으로 용융염-액체금속 계를 상온에서 유사한 물-수은 계로 대체하여 액적 형성 실험을 노즐의 종류에 따라 수행하여 Scheele-Meister 모델의 적용성을 평가하였다. 실험에서 액적의 크기 측정은 디지털카메라와 이미지분석 소프트웨어를 사용하였으며 노즐은 0.018 cm과 0.025 cm의 구멍 크기를 가지며 수은의 통과 길이가 1.3 cm인 상용 니들과 두께가 0.5 cm이며 0.0148 cm 구멍 2개, 0.0135 cm 구멍 3개, 0.0135 cm 구멍 4개인 것을 제작하여 사용하였다. 각각의 노즐에서 형성된 액적은 노즐 아래 20 cm까지 안정적인 구형을 유지하였다. 액적 크기의 측정치를 Scheele-Meister 모델의 추정치와 비교하였을 때 10% 오차 범위 안에서 일치하였다. 실험 결과는 물-수은 계에서 액적을 안정적으로 형성시키는 노즐에 대해 액적 크기 추정을 위한 Scheele-Meister 모델이 적용될 수 있음을 보였다.

디이젤 噴霧 周圍氣體의 엔트레인먼트에 관한 實驗的 硏究 (Experimental Investigation of Entrainment of Ambient Gases into Diesel Spray)

  • 하종률;김봉곤
    • 대한기계학회논문집
    • /
    • 제12권3호
    • /
    • pp.534-540
    • /
    • 1988
  • 본 연구에서는 디이젤분무 주위기체의 유동특성중에서 유동속도에 관하여 보 고 하였다. 본모에서는 분무기간중 분사압력의 시간경과특성이 상이한 두 종류의 분 사계를 사용하여 생성된 분무와 주위 기체와의 유동방향의 시간경과 및 유입시기, 정 상유입속도 도달시간등을 분무의 축방향과 반경방향에 대하여 상세한 측정결과를 얻었 기에 보고한다.

연료의 임계조건을 고려한 디젤 액상분무거동에 관한 연구 (A Study of the Behavior of Liquid Phase Spray Considering Critical Condition of the Fuel)

  • 박종상;김시범;정성식;하종률;염정국
    • 대한기계학회논문집B
    • /
    • 제31권5호
    • /
    • pp.467-472
    • /
    • 2007
  • In this study the penetration distance of liquid phase fuel(i.e. liquid phsae length) was investigated in evaporative field. An exciplex fluorescence method was applied to the evaporative fuel spray to measure and investigate both the liquid and the vapor phase of the injected spray. For accurate investigation, images of the liquid and vapor phase regions were recorded using a 35mm still camera and CCD camera, respectively. Liquid fuel was injected from a single-hole nozzle (l/d=1.0mm/0.2mm) into a constant-volume chamber under high pressure and temperature in order to visualize the spray phenomena. Experimental results indicate that the liquid phase length decreased down to a certain constant value in accordance with increase in the ambient gas density and temperature. The constant value, about 40mm in this study the, is reached when the ambient density and temperature of the used fuel exceed critical condition.