• 제목/요약/키워드: Nozzle Flow

검색결과 1,827건 처리시간 0.029초

NH3 전환효율 극대화를 위한 Urea 인젝터의 분사 최적화에 관한 수치적 연구 (A Numerical Study on the Optimization of Urea Solution Injection to Maximize Conversion Efficiency of NH3)

  • 문성준;조낙원;오세두;정수진;박경우
    • 한국자동차공학회논문집
    • /
    • 제22권3호
    • /
    • pp.171-178
    • /
    • 2014
  • From now on, in order to meet more stringer diesel emission standard, diesel vehicle should be equipped with emission after-treatment devices as NOx reduction catalyst and particulate filters. Urea-SCR is being developed as the most efficient method of reducing NOx emissions in the after-treatment devices of diesel engines, and recent studies have begun to mount the urea-SCR device for diesel passenger cars and light duty vehicles. That is because their operational characteristics are quite different from heavy duty vehicles, urea solution injection should be changed with other conditions. Therefore, the number and diameter of the nozzle, injection directions, mounting positions in front of the catalytic converter are important design factors. In this study, major design parameters concerning urea solution injection in front of SCR are optimized by using a CFD analysis and Taguchi method. The computational prediction of internal flow and spray characteristics in front of SCR was carried out by using STAR-CCM+7.06 code that used to evaluate $NH_3$ uniformity index($NH_3$ UI). The design parameters are optimized by using the $L_{16}$ orthogonal array and small-the-better characteristics of the Taguchi method. As a result, the optimal values are confirmed to be valid in 95% confidence and 5% significance level through analysis of variance(ANOVA). The compared maximize $NH_3$ UI and activation time($NH_3$ UI 0.82) are numerically confirmed that the optimal model provides better conversion efficiency of $NH_3$. In addition, we propose a method to minimize wall-wetting around the urea injector in order to prevent injector blocks caused by solid urea loading. Consequently, the thickness reduction of fluid film in front of mixer is numerically confirmed through the mounting mixer and correcting injection direction by using the trial and error method.

반밀폐된 ISO 9705 화재실에서 비정상 화재특성 예측을 위한 FDS의 성능평가 (Performance Evaluation of FDS for Predicting the Unsteady Fire Characteristics in a Semi-Closed ISO 9705 Room)

  • 문선여;황철홍
    • 한국화재소방학회논문지
    • /
    • 제26권3호
    • /
    • pp.21-28
    • /
    • 2012
  • 비정상(unsteady) 화재성장이 발생되는 반밀폐된 구획에서 환기부족화재의 열 및 화학적 특성에 관한 FDS(Fire Dynamics Simulator)의 예측성능 평가가 수행되었다. 이를 위해 실규모 ISO 9705 표준 화재실의 출입구 폭이 0.1 m로 축소되었으며, spray 노즐을 통해 Heptane 연료유량은 선형적으로 증가되었다. 수치계산에 대한 신뢰도 확보를 위하여 동일 조건에서 수행된 실험결과와의 상세한 비교가 이루어졌다. 적절한 격자계를 이용한 FDS의 결과는 구획 내부의 온도 및 열유속(heat flux)은 비교적 잘 예측하지만, 비정상 CO 및 $CO_2$ 생성특성은 적절히 예측하지 못함을 확인하였다. 이러한 결과는 최근 수행된 유사조건의 정상상태 환기부족 구획화재에 대한 FDS 예측결과와 상반된 것으로서, 반밀폐된 구획화재 모델링에서 FDS를 이용한 비정상 CO 생성특성 예측에 상당한 주위가 요구됨을 확인하였다.

Radio frequency gas-jet boosted 글로우 방전 원자 방출 분광법을 이용한 전도성 및 비 전도성의 다층 두께 분석에 관한 연구 (The Studies of Conductive and Non-Conductive Multi-Layer Depth Analysis by Radio Frequency Gas-Jet Boosted Glow Discharge Atomic Emission Spectrometry)

  • 조원보;이성훈;정종필;최우창;스튜어드 보든;김규환;김경미;김효진;정성욱;이중주
    • 분석과학
    • /
    • 제15권3호
    • /
    • pp.236-242
    • /
    • 2002
  • RF 글로우 방전 원자 방출 분광법을 사용하여 다층 도금강판 두께분석을 하였다. 일반적으로 gas jet boosted 글로우 방전은 플라스마 안정성과 스퍼터링 효율이 우수하여 기존의 두께 분석법에서 측정이 어려운 다층 두께분석이 가능하며, RF를 사용하여 비전도성 실리콘-수지계열의 다층 도금강판 두께분석이 가능하였다. RF gas-jet boosted 글로우 방전은 방전전원과 가스 흐름량 그리고 방전압력에 의해 스퍼터링을 조절할 수 있다. 그래서 스퍼터링 효율에 의해 다층 도금된 강판의 경우 소재에 따라 서로 다른 조건에서 측정할 수가 있었다. 본 연구에서 두께 $20{\mu}m$의 아연층을 가진 아연 도금강판의 두께 및 조성을 분석하기 위해서 최적조건에 대한 연구를 하였고, 두 가지 기준물질로 구성된 수지 도금강판을 이용해서 검량선을 측정하였다. 본 연구에 최적조건 및 검량을 하기 위해서 아연합금 도금강판 및 실리콘-수지 도금강판은 포항 산업 과학 기술원(RIST)에서 제공하였다.

Air abrasive technique을 이용한 복합레진 수복 증례 (TREATMENT OF COMPOSITE RESIN RESTORATION WITH THE AIR ABRASIVE TECHNIQUE)

  • 이창우;장기택;이상훈;한세현
    • 대한소아치과학회지
    • /
    • 제24권4호
    • /
    • pp.763-770
    • /
    • 1997
  • The air abrasive technique is a non-mechanical method by which teeth are treated before restoration and stains and calculi are removed from tooth surfaces using the kinetic energy of small particles. The air abrasive technique in dentistry was first introduced in the 1950's with as instrument called 'Airdent'. But, as the main restorative materials of the period were amalgam and gold, and the instrument's inability to control the flow of particles caused the particles to be spread throughout the clinics, widespread use was not possible. In the 1990's, as these techincal problems were solved and more interest in new restorative materials rose in an effort to preserve sound tooth structure, new developements took place in instruments related to the air abrasive technique. The air abrasive technique produces less pressure, vibration and heat that might cause patient discomfort and facilitates the preservation of sound tooth structure. It also reduces the need for anesthesia and is less harmful to the pulp. Other advantages include increase in dentin bonding strength of composite resin, lower possibility of saliva contamination and maintenance of a dry field. But there is not direct contact between the nozzle and the tooth, the operator cannot use his or her tactile sense and must rely solely upon visual input. Other disadvantages are: the tooth preparation depends on the operator's ability; alpha-alumina particles, after bouncing off the tooth surface, cause damage to dental mirrors; the equipment is expensive and takes up a certain amount of space in the clinic. The author conducted case report using the air abrasive technique on patient visiting the Department of Pediatric Dentistry at Seoul National University Dental Hospital and arrived at the following conclusions. 1. The tooth preparation capability of different air abrasive devices varied widely among manufacturers. 2. It was more effective in treating early caries lesions and stains compared to lesions where caries had already progressed to produce soft dentin. 3. The cold stream and noise caused by the evacuation system was a major cause of discomfort to pediatric patients. 4. As there is no direct contact with tooth surface when using the air abrasive technique for tooth preparation, considerable experience and skill is required for proper tooth preparation.

  • PDF

전산유체역학을 이용한 화장품 오일 캡슐레이션 현상에 대한 연구 (A Study on the Encapsulation of Cosmetic Oil Using Computational Fluid Dynamics)

  • 정남균
    • 한국산학기술학회논문지
    • /
    • 제22권2호
    • /
    • pp.638-643
    • /
    • 2021
  • 농업분야를 비롯한 식품산업 등 다양한 산업에서 사용되고 있는 오일은 기능성 화장품 개발에도 주요한 원료로 사용되고 있다. 오일은 산소나 빛, 습기 또는 고온에 노출되면 화학적으로 불안정하고 산화되기가 쉬운 특징이 있어 이러한 환경에 그대로 노출되지 않도록 캡슐화하기 위한 다양한 시도가 이루어지고 있다. 오일보다 밀도가 큰 냉매 안에 오일을 주입하면, 오일과 냉매의 밀도차로 인한 부력에 의해 오일이 떠오르면서 오일을 캡슐화 할 수 있는데, 본 연구에서는 이러한 방식의 오일 캡슐레이션 장비를 개발함에 있어 오일 캡슐화의 최적의 장비 구동조건을 찾기 위하여 다상유동에 대한 전산해석을 이용하여 오일 캡슐레이션 현상을 모사하였다. 냉매로는 물이나 세럼(Serum)을 이용할 수 있는 데, 상대적으로 점도가 상당히 작은 물을 냉매로 사용했을 경우는 오일과 물을 지속적으로 주입시키는 방식으로 장비를 구동하더라도 오일액적이 잘 생성됨을 알 수 있었으나, 점도가 매우 큰 세럼을 냉매로 사용했을 경우는 오일이 액적의 형태로 노즐에서 이탈되지 않고 길게 늘어지는 양상을 나타냈다. 세럼을 냉매로 이용한 경우는 오일을 연속으로 주입시키는 방법 대신 짧은 순간 빠르게 주입한 후 얼마의 시간동안 주입을 멈춰 부력에 의해 오일액적을 노즐로부터 이탈시키는 방법을 이용하면 오일액적 생성이 가능함을 알 수 있었다.

한냉물리치료기의 개발 (The Development of a Cryotherapy System)

  • 김영호;양길태;장윤희;박시복;류진상
    • 대한의용생체공학회:의공학회지
    • /
    • 제19권6호
    • /
    • pp.617-622
    • /
    • 1998
  • 신냉매인 R-404A를 사용하여 저온특성이 우수한 한냉물리치료기를 개발하였다. 임상평가를 통해서 침온도계를 슬관절 강 내 및 둔부근육 내에 삽입하여 직접 근육온도를 측정하였고, 적외선체열촬영기를 이용하여 표피온도를 객관적으로 측정하였다. 슬관절 부위에 대한 5분 동안의 한냉물리치료에 따른 표피 및 관절강 내 온도변화를 측정한 결과, 표피는 23.3${\pm}4.7^{circ}C$, 관절강 내는 4.1${\pm}1.0^{circ}C$의 온도저하를 보였으며 2~3시간이 경과한 후에도 한냉치료효과가 지속됨을 알 수 있었다. 냉기치료 후 둔부근육에서 측정된 최저온도는 2, 4, 6cm 깊이에서 각각 35.1${\pm}$0.7, 36.2${\pm}$0.4, 36.9${\pm}0.3^{circ}C$였고, 이에 도달하기까지의 시간은 각각 20${\pm}$3.0, 25${\pm}$4.5, 45${\pm}$8.5분이었다. 치료 후 2시간이 경과한 뒤의 온도는 근육의 2, 4, 6cm 깊이에서 각각 36.2${\pm}$0.5, 36.6${\pm}$0.3, 36.9${\pm}0.3^{circ}C$였고, 치료 전에 비해 유의한 온도 차이가 있었다. 또한 5분간 한냉을 가하는 동안 피부 및 근육 내에서 온도의 증가, 즉 반응성 혈관확장은 관찰되지 않았다. 본 연구를 통해서 개발된 한냉물리치료기는 근육의 연축 혹은 강직, 물리적 외상, 화상, 동통의 감소, 관절염 등에 효과적으로 사용되리라 생각된다.

  • PDF

비가열냉동 당근주스의 HACCP 시스템 적용을 위한 미생물학적 위해 분석 (Microbiological Hazard Analysis for HACCP System Application to Non Heat-Frozen Carrot Juice)

  • 이웅수;권상철
    • 한국식품위생안전성학회지
    • /
    • 제29권2호
    • /
    • pp.79-84
    • /
    • 2014
  • 본 연구는 비가열 섭취 냉동 당근주스의 HACCP (Hazard Analysis Critical Control Point)시스템 구축을 위하여 생물학적 위해요소분석을 위한 목적으로 2013년 6월 21일~2014년 3월 30일까지 약 270일간 제주도 제주시 구좌읍 소재에 있는 구좌농협에서 수행하였다. 일반적인 과채주스 제조업체의 제조공정을 참고로 하여 공정도를 작성하였으며, 원료 농산물(당근), 용수와 포장재료 입고, 보관, 세척, 분쇄, 착즙, 냉각, 내포장, 금속검출, 외포장, 보관 및 출하공정에 대하여 Fig. 1과 같이 작성하였다. 원료 당근의 세척 전, 세척 후의 Coliform group, Staphylococcus aureus, Salmonella spp., Bacillus cereus, Listeria Monocytogenes, 장출혈성대장균수를 측정한 결과 Bacillus cereus 는 세척 전 $4.70{\times}10^4CFU/g$이었으나, 세척 후 $1.02{\times}10^2CFU/g$ 검출되었으며, 나머지 병원성균은 검출되지 않았다. 자외선살균공정에서 당근주스의 유속를 변화시키면서 미생물의 변화를 시험한 결과 유속 4 L/min을 한계기준으로 결정하였다. 작업장별 공중낙하균(일반세균수, 대장균, 진균수) 시험결과 세척실의 미생물수는 20 CFU/Plate가 검출되었다. 작업자 손 세척 전후 시험결과 세척 전 일반세균수가 $6{\times}10^4CFU/cm^2$로 높게 나타났으나 손 세척 후에는 검출되지 않아 손 세척 및 소독에 대한 중요성을 교육하고 훈련해야 할 것이다. 제조설비 및 기구의 표면오염도를 검사한 결과 모든 시료에서 대장균군은 검출되지 않았고, 일반세균은 포장기 노즐에서 가장 많은 $8.5{\times}10^4CFU/cm^2$ 검출되었다. 위해분석 결과 병원성미생물을 예방, 감소 또는 제거할 수 있는 자외선살균 공정이 CCP-B (Biological)로 관리되어야 하고, 한계기준은 유속 4 L/min로 결정하였다. 따라서 Kwon의 유산균을 함유한 녹즙의 HACCP에 관한 연구에서와 같이 자외선살균 공정의 한계기준 및 이탈시 조치방법, 검증방법, 교육 훈련과 기록관리 등 철저한 HACCP 관리계획이 필요할 것으로 생각된다.