• 제목/요약/키워드: Notching

검색결과 73건 처리시간 0.027초

Alar Extension Graft를 이용한 콧방울뒤당김의 교정 (The Alar Extension Graft for Retracted Ala)

  • 김현수;노시균
    • Archives of Plastic Surgery
    • /
    • 제36권1호
    • /
    • pp.66-74
    • /
    • 2009
  • Purpose: The importance of the deformities in alar - columellar complex has been underestimated in Asian ethnic groups for the last decades. Fortunately, with increasing familiarity of the open rhinoplasty techniques, the anatomic details of the nasal tip have been pointed up. Definitely, having an interest and demand for improving the sub - normal relationship between the alar rim and columella are indebted for such growing of knowledge about nasal tip anatomy. However, it is true that any single procedure is not settled as versatile and fully confident modality to correct the retracted notching of the alar rim. With this article, I should like to propose another useful option for treating retracted ala. Methods: The author has tried to correct alar rim retraction by means of: (1) Triangular onlay septal cartilage graft on the lower lateral cartilage with the medial end fixed to the anterior surface of the lateral crus(Alar extension graft), (2) Inserting lateral end of the alar extension graft to the vestibular skin pocket in the form of a finger - in - groove, (3) using the vestibular skin in the form of an advancement flap, and (4) using the soft shield graft to prevent possible visible step - off of the alar margin. Results: The author applied an alar extension graft to 16 patients in order to correct a retracted ala for the last 27 months (August, 2003 - October, 2005). The distances from alar rim to long axis of nostril were improved to be within 2 mm in all of the cases, and also the shape of the alar rim changed to a round form. Nostril asymmetry (6%) in one case, temporary palpable step - off (18%) in three cases, temporary visible step - off (6%) in one case, and temporary paresthesia of the tip (25%) in four cases were observed. Conclusion: The alar extension graft is simple and efficacious. It does not need donor sites other than the operative field, and its results are predictable. In particular, since it may give structural intensity to a weak lower lateral cartilage, it may be preferentially used for the correction of a retracted ala that arises from hypoplastic lower lateral cartilage. Moreover intensified lower lateral cartilage also improves the esthetic shape of lobule.

한국형 위성 발사체 성능 검증위성의 진동환경에 관한 연구 (A Study on the Vibrational Environment Test of KSLV-1 Demonstration Satellite)

  • 서현석;김홍배;우성현;채장수;오태식
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.966-970
    • /
    • 2005
  • On the basis of the development of KSLV-1, KoDSat was designed and manufactured to demonstrate the performance of KSLV-1. KoDSat is exposed to a severe vibrational environment at launch. The structural reliability of KoDSat has to be verified using vibrational test. The structural compatibility and verification of components between analysis and test can be proved using environmental vibration test. In this paper, we review the structural characteristic of thruster control unit for a space launch vehicle and design TCU housing using mathematical model. In order to verify the structural compatibility and reliability, half-sine shock, random and sing sweep vibration test was performed. Especially, sing sweep vibration test result is compared with analysis result and mathematical model is verified.

  • PDF

표면부착형 영구자석 동기전동기의 노치 및 영구자석 offset에 의한 코깅토크 저감 연구 (A Study on Cogging Torque Reduction by Teeth Notching and Permanent Magnet offset in Surface-mounted Permanent Magnet Synchronous Motor)

  • 김태우;장정환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.969-970
    • /
    • 2011
  • 본 논문은 표면부착형 영구자석 동기전동기(Surfacemounted Permanent Magnet Synchronous Motor)의 영구자석 offset의 변화와 노치(notch)의 적용에 따른 코깅토크 저감 특성을 분석하고, 중심합성계획법(Central Composite Design)을 이용한 최적 모델 설계에 대한 연구이다. 영구자석 offset만 적용한 모델의 경우 코깅토크의 피크-피크값은 95%로 크게 저감되었지만 정격전류 인가시 평균토크의 감소율이 12.3%로 출력 손실이 크기 때문에 최적 설계를 통해 추가적으로 노치를 적용하고 영구자석 Offset을 조절함으로써 코깅토크 저감율을 96.5%로 개선시킬 수 있었고, 평균토크의 감소율은 7.7%로 영구자석 offset만 적용한 모델보다 평균토크의 감소량이 작아진 것을 확인할 수 있었다.

  • PDF

늑간신경에 발생한 신경초종 1예 (A Case of Neurilemmoma of Intercostal Nerve)

  • 이두연;계기식;송계용
    • Journal of Chest Surgery
    • /
    • 제11권3호
    • /
    • pp.239-245
    • /
    • 1978
  • Recently, we experienced a case of rare neurilemmoma originated from intercostal nerve [9th] in the right chest wall in a 25 year old male officer. The tumor was incidentally found in the routine chest X ray, where the round well circumscribed mass tumor the ninth rib with notching and sclerotic margin, suggesting slowly growing benign benign of chest wall was revealed and the tumor mass was easily extirpated in the exploratory thoracotomy, with uneventful recovery. Grossly, the tumor was firm, partly soft and well circumscribed, measuring 4.5X3.0X 3.0 cm with yellowish smooth outer surface, attached with intercostal nerve trunk. Cut surface exhibits partly grayish white and largely hemorrhagic areas. Microscopically, the characteristic palisading arrangement of schwann cells and Verocay bodies are seen but dominant features are cystic degeneration and hemorrhage with organization and fibrosis. The sheath of intercostal nerve and capsule of neurilemmoma were con joined. There is no evidence of malignancy. The tumor was confirmed as neurilemmoma of intercostal nerve, Antony type B.

  • PDF

A Study on the Development of Progressive Die for Multi-Stage Forming

  • Sim, Sung-Bo;Jang, Chan-Ho;Sung, Yul-Min;Lee, Sung-Taeg
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.86-91
    • /
    • 2002
  • The production part requiring multiple processes such as piecing, blanking and notching, are performed with a high production rates in progressive die. In order to prevent the dejects of process result, the optimum of strip process layout design, die design, die making, and tryout with inspection etc. are needed. According to these factors of die development process, they required theory and practice of metal working process and its phenomena, die structure, machining conditions for die making, die materials, heat treatment of die camponents, know-how and so on. In this study, we designed and analyzed die camponents also simulated the strip process layout of multiple stage drawing by DEFORM. Especially the result of tryout and its analysis become to the feature of this study.

  • PDF

칼라화상관 전극 프로그레시브금형의 자동설계시스템개발 (Development of an Automatic Design System of Progressive Die for making CPT grid)

  • 한규택
    • 한국생산제조학회지
    • /
    • 제7권4호
    • /
    • pp.14-20
    • /
    • 1998
  • This paper describes a computer-aided die design system of progressive die for making CPT grid. An approach to the development of the automatic design system is based on knowledge-based rules. The developed system is designed by considering several factors, such as grid geometry and punch profile. Grid, a key component of electronic gun, is formed through a sequence of many operations, among which the pilot piercing, beading, notching, bending, swaging and slotting etc. Using the developed system, design parameters are determined and output is generated in graphic forms. Therefore the developed system provides part drawing and the assembly drawing of die set.

Acromegaloid Facial Appearance Syndrome - A New Case in India

  • Rai, Arpita;Sattur, Atul P.;Naikmasur, Venkatesh G.
    • Journal of Genetic Medicine
    • /
    • 제10권1호
    • /
    • pp.57-61
    • /
    • 2013
  • Acromegaloid Facial Appearance syndrome is a very rare syndrome combining acromegaloid-like facial appearance, thickened lips and oral mucosa and acral enlargement. Progressive facial dysmorphism is characterized by a coarse facies, a long bulbous nose, high-arched eyebrows, and thickening of the lips, oral mucosa leading to exaggerated rugae and frenula, furrowed tongue and narrow palpebral fissures. We report a case of acromegaloid facial appearance syndrome in a 19-year-old male patient who presented with all the characteristic features of the syndrome along with previously unreported anomalies like dystrophic nails, postaxial polydactyly and incisal notching of teeth.

힘제한 방법을 이용한 소형 위성의 진동시험 (Force Limited Vibration Tests of Micro-Satellites)

  • 김영기;김홍배;김경운;우성현;김성훈;문상무
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.446-451
    • /
    • 2004
  • Over testing problems of satellites and theirs components have been issued due to their effects on satellite development cost and schedule. Force limited vibration tests were introduced as solution of the problems in 1980s. Over testing phenomena occurs due to the lack of similarity on interface impedance. Force limited vibration tests control interface force to simulate actual interface impedance. In this research, force limited vibration tests are applied on two satellites environmental tests. Force limits are calculated by using TDFS method and Semi-Empirical method. Four force sensors are employed to control interface force. The tests prove that force limited control reduced maximum interface acceleration in order of 3.

  • PDF

박판 포밍제품의 프로그레시브 금형개발에 관한 연구 (A Study on the Progressive Die Development of Sheet Metal Forming Part)

  • 심성보;이성택
    • 한국기계가공학회지
    • /
    • 제3권4호
    • /
    • pp.43-49
    • /
    • 2004
  • The production parts have required multiple processes such as drawing, piercing, blanking and notching etc. are performed with a high production rates in progressive die. In order to prevent the defects of process result, the optimization of strip process layout design, die design, die making, and tryout etc. are needed. According to these factors of die development process, it has been required that the theory and practice of metal working process and its phenomena, die structure, machining conditions for die making, die materials, heat treatment of die components, processing know-how and so on. In this study, we designed and analyzed die components through the carrying out of upper relevant matters also simulated the strip process layout of multiple stage drawing by DEFORM. Especially the result of tryout and its analysis became to the feature of this study with a system of PDDC(Progressive Die design by computer).

  • PDF

구순구개열 환자에 있어 직선봉합법의 역할 (Revisited Straight Line Technique for Unilateral Cleft Lip)

  • 서병무
    • 대한구순구개열학회지
    • /
    • 제11권1호
    • /
    • pp.31-36
    • /
    • 2008
  • The variations of cleft lip deformities imposed the difficulty to the surgical correction for them. Straight line technique for cleft lip surgery has been ignored quite long since other techniques were developed. Initially the straight line technique was introduced and widely accepted because it is simple and easy to perform during the period of no adequate anesthetics. But it was abandoned for its several shortcomings such as tighten lip, vermilion notching, anatomical distortion, and wound contractures. Recently, some groups advocated the usefulness of straight line technique which has a significant modification from its original form. Additionally the variable degree of cleft lip deformity allows simple straight line closure for those patients. Here a case of simple straight line technique was presented and discussed for its reliability and plausible results as well.

  • PDF