• 제목/요약/키워드: Nose-only inhalation chamber

검색결과 4건 처리시간 0.017초

흡입독성평가를 위한 비부노출 챔버의 유동흐름 특성 (Characteristics of flow field of nose-only exposure chamber for inhalation toxicity evaluation)

  • 노학재;봉춘근;봉하경;김용구;조명행;김상화;김대성
    • 한국입자에어로졸학회지
    • /
    • 제12권1호
    • /
    • pp.1-9
    • /
    • 2016
  • In this work, we evaluated the characteristics of flow field and uniformity of the nose-only exposure chambers for the inhalation toxicity test. Computational fluid dynamics (CFD) modeling was carried out to demonstrate uniformity of the nose-only exposure chambers. Because it is very important in the inhalation toxicity experiments that test materials are distributed uniformly to each holder of the chamber. The test was done with these 3 types of chamber with different form to develop inhalation toxicity evaluation system, easy-to-operate system among exposure chamber used for evaluating inhalation toxicity of environmental chemical mixtures. Through CFD interpretation, nose-only exposure chamber was made with the selection of the optimal conditions. For its evaluation, one type of fragrance was selected and measured particle size distribution of each port. The gene becoming luminous to green fluorescence was combined with GPT-SPE, a type of tGFP vector, to be inhaled to the mouse. Based on this, luminous intensity was checked. As a result, total particle number concentration of each port had average value of $3.17{\times}10^6{\sharp}/cm^3$ and range of the highest and lowest concentration value was approximately ${\pm}4.8%$. Autopsy of lung tissues of mouse showed that it had clearly better delivery of gene compared to the control group.

LC50 Determination of tert-Butyl Acetate using a Nose Only Inhalation Exposure in Rats

  • Yang, Young-Su;Lee, Jin-Soo;Kwon, Soon-Jin;Seo, Heung-Sik;Choi, Seong-Jin;Yu, Hee-Jin;Song, Jeong-Ah;Lee, Kyu-Hong;Lee, Byoung-Seok;Heo, Jeong-Doo;Cho, Kyu-Hyuk;Song, Chang-Woo
    • Toxicological Research
    • /
    • 제26권4호
    • /
    • pp.293-300
    • /
    • 2010
  • tert-Butyl acetate (TBAc) is an organic solvent, which is commonly used in architectural coatings and industrial solvents. It has recently been exempted from the definition of a volatile organic compound (VOC) by the Air Resources Board (ARB). Since the use of TBAc as a substitute for other VOCs has increased, thus its potential risk in humans has also increased. However, its inhalation toxicity data in the literature are very limited. Hence, inhalation exposure to TBAc was carried out to investigate its toxic effects in this study. Adult male rats were exposed to TBAc for 4 h for 1 day by using a nose-only inhalation exposure chamber (low dose, $2370\;mg/m^3$ (500 ppm); high dose, $9482\;mg/m^3$ (2000 ppm)). Shamtreated control rats were exposed to clean air in the inhalation chamber for the same period. The animals were killed at 2, 7, and 15 days after exposure. At each time point, body weight measurement, bronchoalveolar lavage fluid (BALF) analysis, histopathological examination, and biochemical assay were performed. No treatment-related abnormal effects were observed in any group according to time course. Based on those findings, the median lethal concentration ($LC_{50}$) of TBAc was over $9482\;mg/m^3$ in this study. According to the MSDS, the 4 h $LC_{50}$ for TBAc for rats is over $2230\;mg/m^3$. We suggested that this value is changed and these findings may be applied in the risk assessment of TBAc which could be beneficial in a sub-acute study.

Effect of Nano-sized Carbon Black Particles on Lung and Circulatory System by Inhalation Exposure in Rats

  • Kim, Jong-Kyu;Kang, Min-Gu;Cho, Hae-Won;Han, Jeong-Hee;Chung, Yong-Hyun;Rim, Kyung-Taek;Yang, Jeong-Sun;Kim, Hwa;Lee, Moo-Yeol
    • Safety and Health at Work
    • /
    • 제2권3호
    • /
    • pp.282-289
    • /
    • 2011
  • Objectives: We sought to establish a novel method to generate nano-sized carbon black particles (nano-CBPs) with an average size smaller than 100 nm for examining the inhalation exposure risks of experimental rats. We also tested the effect of nano-CBPs on the pulmonary and circulatory systems. Methods: We used chemical vapor deposition (CVD) without the addition of any additives to generate nano-CBPs with a particle size (electrical mobility diameter) of less than 100nm to examine the effects of inhalation exposure. Nano-CBPs were applied to a nose-only inhalation chamber system for studying the inhalation toxicity in rats. The effect on the lungs and circulatory system was determined according to the degree of inflammation as quantified by bronchoalveolar lavage fluid (BALF). The functional alteration of the hemostatic and vasomotor activities was measured by plasma coagulation, platelet activity, contraction and relaxation of blood vessels. Results: Nano-CBPs were generated in the range of 83.3-87.9 nm. Rats were exposed for 4 hour/day, 5 days/week for 4 weeks to $4.2{\times}10^6$, $6.2{\times}10^5$, and $1.3{\times}10^5$ particles/$cm^3$. Exposure of nano-CBPs by inhalation resulted in minimal pulmonary inflammation and did not appear to damage the lung tissue. In addition, there was no significant effect on blood functions, such as plasma coagulation and platelet aggregation, or on vasomotor function. Conclusion: We successfully generated nano-CBPs in the range of 83.3-87.9 nm at a maximum concentration of $4.2{\times}10^6$ particles/$cm^3$ in a nose-only inhalation chamber system. This reliable method can be useful to investigate the biological and toxicological effects of inhalation exposure to nano-CBPs on experimental rats.

Acute Pulmonary Toxicity and Body Distribution of Inhaled Metallic Silver Nanoparticles

  • Kwon, Jung-Taek;Minai-Tehrani, Arash;Hwang, Soon-Kyung;Kim, Ji-Eun;Shin, Ji-Young;Yu, Kyeong-Nam;Chang, Seung-Hee;Kim, Dae-Seong;Kwon, Yong-Taek;Choi, In-Ja;Cheong, Yun-Hee;Kim, Jun-Sung;Cho, Myung-Haing
    • Toxicological Research
    • /
    • 제28권1호
    • /
    • pp.25-31
    • /
    • 2012
  • The purpose of this study was to determine the acute pulmonary toxicity of metallic silver nanoparticles (MSNPs, 20.30 nm in diameter). Acute pulmonary toxicity and body distribution of inhaled MSNPs in mice were evaluated using a nose-only exposure chamber (NOEC) system. Bronchoalveolar lavage (BAL) fluid analysis, Western blotting, histopathological changes, and silver burdens in various organs were determined in mice. Mice were exposed to MSNPs for 6 hrs. The mean concentration, total surface area, volume and mass concentrations in the NOEC were maintained at $1.93{\times}10^7$ particles/$cm^3$, $1.09{\times}10^{10}\;nm^2/cm^3$, $2.72{\times}10^{11}\;nm^3/cm^3$, and 2854.62 ${\mu}g/m^3$, respectively. Inhalation of MSPNs caused mild pulmonary toxicity with distribution of silver in various organs but the silver burdens decreased rapidly at 24-hrs post-exposure in the lung. Furthermore, inhaled MSNPs induced activation of mitogen-activated protein kinase (MAPK) signaling in the lung. In summary, single inhaled MSNPs caused mild pulmonary toxicity, which was associated with activated MAPK signaling. Taken together, our results suggest that the inhalation toxicity of MSNPs should be carefully considered at the molecular level.