• Title/Summary/Keyword: Normalized factor

Search Result 320, Processing Time 0.022 seconds

An Efficient Decoding Algorithm of LDPC codes (LDPC 부호의 효율적인 복호 방법에 관한 연구)

  • Kim, Joon-Sung;Shin, Min-Ho;Song, Hong-Yeop
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.9C
    • /
    • pp.1227-1234
    • /
    • 2004
  • In this paper, we propose a modified Normalized-BP algorithm by changing the normalization factor according to the reliability of updated messages. Proposed algorithm has almost same decoding complexity as Normalized-BP algorithm and achieves a bit-error probability of $10^4$within 0.02dB away from compared with LLR-BP algorithm.

Sound Radiation due to Tire Tread Vibration (타이어 트레드의 진동에 의한 음향방사)

  • Kim, Byoung-Sam;Hong, Dong-Pyo;Chung, Tae-Jin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.13 no.2
    • /
    • pp.13-22
    • /
    • 1994
  • A theoretical model is studied to describe the sound radiation by the surface vibration of in-service tires. The tire is modeled as a circular ring model. The effects of normalized frequency and structrual loss factor are included. Through numerical integration of the sound pressure, the radiated sound power is calculated as a fuction of normalized frequency and structural loss factor. The basic sound radiation mechanism is shown to be the damped progressive wave field on the structure in the vicinity of the applied force. The results indicate that the potential sound reduction might be obtained if values of normalized frequency and structural loss factor are investigated.

  • PDF

Analysis on Wind Turbine Degradation of the Shinan Wind Power Plant (신안풍력발전소 풍력터빈의 성능저하 분석)

  • Kim, Hyun-Goo
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.4
    • /
    • pp.46-50
    • /
    • 2013
  • This paper investigated wind turbine degradation quantitatively by analyzing the short-term operation records of the Shinan Wind Power Plant. Instead of a capacity factor which is needed to be normalized its variability due to monthly wind speed change, this study suggests an analysis method by taking the difference between the theoretical power output calculated from the nacelle wind speed and actual power output as the quantitative index of performance degradation. For three-year SCADA data analysis of the Shinan Wind Power Plant, it was confirmed that power output degradation rate of 0.54% per year. This value is within the average reduction rate 0.4%/year~0.9%/year of normalized capacity factor of the onshore wind power plants in U.K. and Denmark; however, lower than the rate 2%/year of Canadian wind power plants.

Dynamic Stress Intensity Factors of the Half Infinite Crack in the Orthotropic Material Strip with a Large Anisotropic Ratio (이방성비가 큰 직교이방성체의 반 무한 균열에 대한 동적 응력확대계수에 관한 연구)

  • Baek, Un-Cheol;Hwang, Jae-Seok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.6 s.177
    • /
    • pp.1557-1564
    • /
    • 2000
  • When the half infinite crack in the orthotropic material strip with a large anisotropic ratio(E11>>E22) propagates with constant velocity, dynamic stress component $\sigma$y occurre d along the $\chi$ axis is derived by using the Fourier transformation and Wiener-Hopf technique, and the dynamic stress intensity factor is derived. The dynamic stress intensity factor depends on a crack velocity, mechanical properties and specimen hight. The normalized dynamic stress intensity factors approach the maximum values when normalized time(=Cs/a) is about 2. They have the constant values when the normalized time is greater than or equal to about 2, and decrease with increasing a/h(h: specimen hight, a: crack length) and the normalized crack propagation velocity( = c/Cs, Cs: shear wave velocity, c: crack propagation velocity).

A Study on Efficient CNU Algorithm for High Speed LDPC decoding in DVB-S2 (DVB-S2 기반 고속 LDPC 복호를 위한 효율적인 CNU 계산방식에 관한 연구)

  • Lim, Byeong-Su;Kim, Min-Hyuk;Jung, Ji-Won
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.9
    • /
    • pp.1892-1897
    • /
    • 2012
  • In this paper, efficient CNU(Check Node Update) algorithms are analyzed for high speed LDPC decoding in DVB-S2 standard. In aspect to CNU methods, there are some kinds of CNU methods. Among of them, MP (Min Product) method is quite often used in LDPC decoding. However MP needs LUT (Look Up Table) that is critical path in LDPC decoding speed. A new SC-NMS (Self-Corrected Normalized Min-Sum) method is proposed in the paper. NMS needs only normalized scaling factor instead of LUT and compensates the overestimation of MP approximation. In addition, SC method is proposed. It gives a faster convergence toward a decoded codeword. If a message change its sign between two iterations, it is not reliable and to avoid to propagate noisy information, its module is set to 0. The performance of SC-NMS has a little degrade compare to MP by 0.1 dB, however considering computational complexity and decoding speed, SC-NMS algorithm is optimal method for CNU algorithm.

Analysis of Major Error Factors in Coherent Beam Combination: Phase, Tip Tilt, Polarization Angle, and Beam Quality

  • Jeongkyun Na;Byungho Kim;Changsu Jun;Yoonchan Jeong
    • Current Optics and Photonics
    • /
    • v.8 no.4
    • /
    • pp.406-415
    • /
    • 2024
  • The major error factors that degrade the efficiency of coherent beam combining (CBC) are numerically studied in a comprehensive manner, paying particular attention to phase, tip-tilt, polarization angle, and beam quality. The power in the bucket (PIB), normalized to the zero-error PIB, is used as a figure of merit to quantify the effect of each error factor. To maintain a normalized PIB greater than or equal to 95% in a 3-channel CBC configuration, the errors in phase, tip-tilt, and polarization angle should be less than 1.06 radians, 1.25 ㎛, and 1.06 radians respectively, when each of the three parameters is calculated independently with the other two set to zero. In a worst-case scenario of the composite errors within the parameter range for the independent-95%-normalized-PIB condition, the aggregate effect would reduce the normalized PIB to 83.8%. It is noteworthy that the PIB performances of a CBC system, depending on phase and polarization-angle errors, share the same characteristic feature. A statistical approach for each error factor is also introduced, to assess a CBC system with an extended number of channels. The impact of the laser's beam-quality factor M2 on the combining efficiency is also analyzed, based on a super-Gaussian beam. When M2 increases from 1 to 1.3, the normalized PIB is reduced by 2.6%, 11.8%, 12.8%, and 13.2% for a single-channel configuration and 3-, 7-, and 19-channel CBC configurations respectively. This comprehensive numerical study is expected to pave the way for advances in the evaluation and design of multichannel CBC systems and other related applications.

A Study on Optimal Selection of Inductance for Power Factor Improvement of Buck AC/DC LED Driver With Wide Input Voltage Range (입력 전압 범위가 넓은 벅 AC/DC LED 구동기의 역률 개선을 위한 최적 인덕턴스 선택에 관한 연구)

  • Kim, Marn-Go
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.4
    • /
    • pp.302-305
    • /
    • 2021
  • Selection of the optimal inductance for power factor improvement of a buck AC/DC light-emitting diode (LED) driver with wide input voltage range is described in this study. The power factor change based on the slope compensation is obtained for various normalized output current (NOC) values using discrete-time domain analysis. The possibility of implementing constant slope compensation is described using power factor curves for various NOC values. NOC = 0.5 is chosen for the value of inductance with consideration for the simple implementation and reduction of inductor size. Experimental results of the inductance corresponding to NOC = 0.5 are presented.

Correlating Fully Anechoic Chamber to Open Area Test Site Measurements by the Normalized Site Attenuation

  • Kang, Tae-Weon;Kim, Byung-Wook;Chung, Yeon-Choon;Kim, Hyo-Tae
    • Journal of electromagnetic engineering and science
    • /
    • v.1 no.2
    • /
    • pp.126-130
    • /
    • 2001
  • The performance of a fully anechoic chamber (FAC) for radiated emission (RE) measurements has been evaluated using the normalized site attenuation (NSA). To do this, the antenna factor (AF) of a set consisting of nearly identical antennas has been calibrated at an open area test site (OATS). Appropriate correlation factor (CF) between the chamber and the OATS has been calculated. Results show that the performance of the chamber is fairly good with respect to the ANSI-limit except 41~66 MHz far vertical polarization and near 900 MHz for horizontal polarization.

  • PDF

The Effect of Laser Geometry and Material Parameters on the Single Mode Gain Difference in Quarter Wavelength Shifted DFB Laser above Threshold Current (문턱전류이상에서 구조 및 재료 변수들이 $\lambda$/4위상천이 DFB 레이저의 단일모드 이득차에 미치는 영향)

  • 이홍석;김홍국;김부균;이병호
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.3
    • /
    • pp.75-84
    • /
    • 1999
  • Systematic studies for the effect of the linewidth enhancement factor, the confinement factor, the internal loss and the cavity length on the single mode gain difference and the frequency detuning are performed for $\lambda$/4 phase shifted DFB lasers above threshold. The above threshold characteristics are mainly determined by the linewidth enhancement factor, not by the confinement factor or the parameter defined by the product of the linewidth enhancement factor and the confinement factor. The normalized internal loss defined by the product of the internal loss and the cavity length mainly determines the above threshold characteristics compared to that of the internal loss or the cavity length alone. The effect of the cavity length on threshold characteristics is larger than that of the internal loss in the case of the same normalized internal loss. The above threshold characteristics of quantum well lasers are more resistant to the variations of the confinement factor and the normalized internal loss than those of bulk lasers due to the small linewidth enhancement factor.

  • PDF

Evaluation of Liquefiable Soils by Energy Concept (에너지 개념에 기초한 액상화 평가방법에 관한 연구)

  • Kim, Soo-Il;Sun, Yu-Jung;Park, Keun-Bo;Park, Seong-Yong
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.590-599
    • /
    • 2006
  • In this study, Liquefaction characteristics of saturated sand under various dynamic loadings such as sinusoidal loading, increasing wedge loading, and real earthquake loading were investigated focusing on the dissipated energy. From the results of cyclic triaxial test, liquefaction resistance strength was calculated by the concept of energy according to the type of input loading. Liquefaction resistance strength was expressed in accumulated dissipated energy calculated from stress-strain curve(hysteresis loop). The dissipated energy according to loading type was compared and the energy-based evaluation was proposed. The procedures are presented in terms of normalized energy demand(NED), normalized energy capacity(NEC), and factor of safely, where NED is the load imparted to the soil by the loading(both amplitude and duration), NEC is the demand required to induce liquefaction, and factor of safely is defined as the ratio of NEC and NED.

  • PDF