• Title/Summary/Keyword: Normal values

Search Result 3,101, Processing Time 0.696 seconds

A Study on the Correlation among the Patterns of the Zone 1, 2, 3 of Factor AA in 7-Zone-Diagnostic System and the Clinical Parameters (7구역진단기의 Factor AA 제1, 2, 3구역 유형과 임상지표와의 상관성 연구)

  • Cho, Yi-Hyun;Yu, Jung-Suk;Lee, Hwi-Yong;Song, Beom-Yong
    • Journal of Acupuncture Research
    • /
    • v.25 no.6
    • /
    • pp.67-76
    • /
    • 2008
  • Objectives : The 7-zone-diagnostic system is a diagnostic device to predetermine bodily locations by measuring the energy of body. This study was to investigate the relation between the different patterns of Zone 1, 2, 3 of Factor AA in CP-6000A(VEGA, Germany), 7-zone-diagnostic system and clinical parameters. The purpose of this study was relation Korean traditional medicine and western medicine with the data from 7-zone-diagnostic system and the clinical parameters. Methods : This study was carried out with the data from some clinical parameters. We made three groups according to the Factor AA patterns of CP-6000A. The Factor AA pattern of Group A is that the red bar graph of zone 1, 2, 3 were higher than the normal range and the others were the normal range. The Factor AA pattern of Group B was that the red bar graph of zone 1, 2, 3 was the normal range and the others were the normal range. The Factor AA pattern of Group C was that the red bar graph of zone 1, 2, 3 was lower than the normal range and the others were the normal range. After the data from clinical parameters to correspond with conditions of each group were selected, the data from clinical parameters among each groups analyzed statistically. Results : The values of GOT, GPT, r-GPT, Triglyceride, BUN, Uric acid of group A was higher than group C. Gastroscope of group A and B was higher than group C. Conclusions : It is thought that the red bar graph of zone 1, 2, 3 is higher, the group has the higher energy and the energy has a character of fire(熱). Those patterns have a high risk of hyperlipermia and liver, stomach disease.

  • PDF

A Study on Plasma Renin Activity in Essential Hypertension (본태성고혈압(本態性高血壓)에서의 혈장(血漿) Renin 활성(活性)에 관(關)한 연구(硏究))

  • Choe, Kang-Won;Lee, Jung-Sang;Cho, Bo-Yeon;Koh, Chang-Soon;Lee, Mun-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.9 no.1
    • /
    • pp.21-29
    • /
    • 1975
  • Radioimmunoassay for the measurement of plasma renin activity (PRA) was performed in 43 normal Koreans and 45 patients with essential hypertension. Plasma samples were drawn in supine position in the morning and after upright posture for 4 hours. Urinary sodium excretion rates were measured in the concurrent 24 hour urine samples, as an index of their sodium balance. The results were as follows: 1. There was an inverse correlation between 24hr sodium excretion and PRA. The normal values of PRA in supine position ranged from 1.0 to 7.0 ng/ml/hr. when 24 hour sodium excretion were between 50 to 150 mEq. PRA in elderly tended to be low. 2. When stimulated by 4 hour upright posture, PRA increased by 2.6 times from the baseline value. 3. Of the 45 patients with essential hypertension, PRA was low in 10 cases (22.2%), normal in 28 cases (62.2%), and high in 7 cases (15.6%). 4. In the normal and high renin groups, who tended to be younger in ages, mean diastolic blood pressure and BUN were higher than in low renin group. Though hypertensive retinopathy and left ventricular hypertrophy in ECG were more prevalent in the former, no significant differences were noted as in the case of serum cholesterol. 5. There were 8 cases of cardiovascular complications (7 with cerebral vascular accident, 1 with myocardial infarction); 3 in low renin group (30%), 2 in normal renin (7.1%) and 3 in high renin group (42.9%). This figure indicated higher rate of cardiovascular complications in high renin groups, and lower rate in normal renin group. But the incidence of the complication was not significantly low in low renin group.

  • PDF

A Roentgenographic Cephalometric Study of Temporomandibular Joint Subluxation (악관절아탈구증에 대한 두부방사선계측학적 연구)

  • Kim Han Pyong
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.11 no.1
    • /
    • pp.23-32
    • /
    • 1981
  • The purpose of this study was to assess temporomandibular joint subluxation by means of cephalometry using two lateral cephalograms from each person with in centric occlusion and wide-open mouth position, and to compare patient group with subluxation to normal control group in the measurements and correlation coefficient. The 200 cephalograms of 100 Korean adults, patient group consisted of 24 females and 26 males ranged from 17 to 63 years age and the normal control group consisted of 20 females and 30 males ranged from 18 to 56 years age, were studied and analyzed statistically. The results were as follows; 1. In the comparison of patient group vs normal control group in the measurements, statistically significant differences were found in C-C', C'-PTM, K-FH, K-PTM, Gn-Gn', C-S-C', Gn-S-Gn', Gn-K-Gn', GoGn-SN, and GoGn-Go'Gn'. K-point* of patient group was located antero - superiorly than of normal control group, and the significance level was higher in K-PTM than in K-FH. There was no statistically significant difference found in local relationship of C-point between patient group and normal control group. The values of correlation coefficient among all measurements were in 0.958≥r≥-0.760, and the highest value was in Gn-Gn' to GoGn-Go'Gn' and Gn-K-Gn' to Gn-Gn', and the lowest value was in C'-PTM to Gn-K-Gn' of normal control group. K was determined as a point of intersection by a perpendicular bisector of Gn-Gn' and a perpendicular bisector of C-C'.

  • PDF

Slip-Related Changes in Plantar Pressure Distribution, and Parameters for Early Detection of Slip Events

  • Choi, Seungyoung;Cho, Hyungpil;Kang, Boram;Lee, Dong Hun;Kim, Mi Jung;Jang, Seong Ho
    • Annals of Rehabilitation Medicine
    • /
    • v.39 no.6
    • /
    • pp.897-904
    • /
    • 2015
  • Objective To investigate differences in plantar pressure distribution between a normal gait and unpredictable slip events to predict the initiation of the slipping process. Methods Eleven male participants were enrolled. Subjects walked onto a wooden tile, and two layers of oily vinyl sheet were placed on the expected spot of the 4th step to induce a slip. An insole pressure-measuring system was used to monitor plantar pressure distribution. This system measured plantar pressure in four regions (the toes, metatarsal head, arch, and heel) for three events: the step during normal gait; the recovered step, when the subject recovered from a slip; and the uncorrected, harmful slipped step. Four variables were analyzed: peak pressure (PP), contact time (CT), the pressure-time integral (PTI), and the instant of peak pressure (IPP). Results The plantar pressure pattern in the heel was unique, as compared with other parts of the sole. In the heel, PP, CT, and PTI values were high in slipped and recovered steps compared with normal steps. The IPP differed markedly among the three steps. The IPPs in the heel for the three events were, in descending order (from latest to earliest), slipped, recovered, and normal steps, whereas in the other regions the order was normal, recovered, and slipped steps. Finally, the metatarsal head-to-heel IPP ratios for the normal, recovered, and slipped steps were $6.1{\pm}2.9$, $3.1{\pm}3.0$, and $2.2{\pm}2.5$, respectively. Conclusion A distinctive plantar pressure pattern in the heel might be useful for early detection of a slip event to prevent slip-related injuries.

Evaluation of repeated measurement stability of dentition type of maxillary anterior tooth: an in vitro study (상악 전치의 치열 형태에 따른 스캔 반복 측정 안정성 평가: in vitro 연구)

  • Park, Dong-In;Son, Ho-Jung;Kim, Woong-Chul;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.41 no.3
    • /
    • pp.211-217
    • /
    • 2019
  • Purpose: The purpose of this study is to evaluate the repeated measurement stability of scans related to dentition type. Methods: A normal model and the crowding and diastema models are also duplicated using duplicating silicon. After that, a plaster model is made using a plaster-type plaster on the duplicate mold, and each model is scanned 5 times by using an extraoral scanner. The gingival part and molar part were deleted from the 3D STL file data obtained through scanning. Using the 3D stl file obtained in this way, data is nested between model groups. Thereafter, RMS values obtained were compared and evaluated. The normality test of the data was performed for the statistical application of repeated measurements with dentition type, and the normality was satisfied. Therefore, the one-way ANOVA test, which is a parametric statistical method, was applied, and post-tests were processed by the Scheffe method. Results: The average size of each RMS in the Normal, Diastema, and Crowding groups was Normal> Crowding> Diastema. However, the standard deviation was in the order of Crowding> Normal> Diastema. The average value of each data is as follows. Diastema model was the smallest ($5.51{\pm}0.55{\mu}m$), followed by the crowding model ($12.30{\pm}2.50{\mu}m$). The normal model showed the maximum error ($13.23{\pm}1.06{\mu}m$). Conclusion: There was a statistically significant difference in the repeatability of the scanning measurements according to the dentition type. Therefore, you should be more careful when scanning the normal intense or crowded dentition than scanning the interdental lining. However, this error value was within the range of applicable errors for all clinical cases.

Normal data based rotating machine anomaly detection using CNN with self-labeling

  • Bae, Jaewoong;Jung, Wonho;Park, Yong-Hwa
    • Smart Structures and Systems
    • /
    • v.29 no.6
    • /
    • pp.757-766
    • /
    • 2022
  • To train deep learning algorithms, a sufficient number of data are required. However, in most engineering systems, the acquisition of fault data is difficult or sometimes not feasible, while normal data are secured. The dearth of data is one of the major challenges to developing deep learning models, and fault diagnosis in particular cannot be made in the absence of fault data. With this context, this paper proposes an anomaly detection methodology for rotating machines using only normal data with self-labeling. Since only normal data are used for anomaly detection, a self-labeling method is used to generate a new labeled dataset. The overall procedure includes the following three steps: (1) transformation of normal data to self-labeled data based on a pretext task, (2) training the convolutional neural networks (CNN), and (3) anomaly detection using defined anomaly score based on the softmax output of the trained CNN. The softmax value of the abnormal sample shows different behavior from the normal softmax values. To verify the proposed method, four case studies were conducted, on the Case Western Reserve University (CWRU) bearing dataset, IEEE PHM 2012 data challenge dataset, PHMAP 2021 data challenge dataset, and laboratory bearing testbed; and the results were compared to those of existing machine learning and deep learning methods. The results showed that the proposed algorithm could detect faults in the bearing testbed and compressor with over 99.7% accuracy. In particular, it was possible to detect not only bearing faults but also structural faults such as unbalance and belt looseness with very high accuracy. Compared with the existing GAN, the autoencoder-based anomaly detection algorithm, the proposed method showed high anomaly detection performance.

Application of Simulated Three Dimensional CT Image in Orthognathic Surgery (악교정 수술에서 모의 조종된 3차원 전산화 단층촬영상의 응용)

  • Kim Hyung-Don;Yoo Sun-Kook;Lee Kyoung-Sang;Park Chang-Seo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.28 no.2
    • /
    • pp.363-385
    • /
    • 1998
  • In orthodontics and orthognathic surgery. cephalogram has been routine practice in diagnosis and treatment evaluation of craniofacial deformity. But its inherent distortion of actual length and angles during projecting three dimensional object to two dimensional plane might cause errors in quantitative analysis of shape and size. Therefore, it is desirable that three dimensional object is diagnosed and evaluated three dimensionally and three dimensional CT image is best for three dimensional analysis. Development of clinic necessitates evaluation of result of treatment and comparison before and after surgery. It is desirable that patient that was diagnosed and planned by three dimensional computed tomography before surgery is evaluated by three dimensional computed tomography after surgery. too. But Because there is no standardized normal values in three dimension now and three dimensional Computed Tomography needs expensive equipments and because of its expenses and amount of exposure to radiation. limitations still remain to be solved in its application to routine practice. If postoperative three dimensional image is constructed by pre and postoperative lateral and postero-anterior cephalograms and preoperative three dimensional computed tomogram. pre and postoperative image will be compared and evaluated three dimensionally without three dimensional computed tomography after surgery and that will contribute to standardize normal values in three dimension. This study introduced new method that computer-simulated three dimensional image was constructed by preoperative three dimensional computed tomogram and pre and postoperative lateral and postero-anterior cephalograms. and for validation of new method. in four cases of dry skull that position of mandible was displaced and four patients of orthognathic surgery. computer-simulated three dimensional image and actual postoperative three dimensional image were compared. The results were as follows. 1. In four cases of dry skull that position of mandible was displaced. range of displacement between computer-simulated three dimensional images and actual postoperative three dimensional images in co-ordinates values was from -1.8 mm to 1.8 mm and 94% in displacement of all co-ordinates values was from -1.0 mm to 1.0 mm and no significant difference between computer-simulated three dimensional images and actual postoperative three dimensional images was noticed(p>0.05). 2. In four cases of orthognathic surgery patients, range of displacement between computer­simulated three dimensional images and actual postoperative three dimensional images in coordinates values was from -6.7 mm to 7.7 mm and 90% in displacement of all co-ordinates values was from -4.0 to 4.0 mm and no significant difference between computer-simulated three dimensional images and actual postoperative three dimensional images was noticed(p>0.05). Conclusively. computer-simulated three dimensional image was constructed by preoperative three dimensional computed tomogram and pre and postoperative lateral and postero-anterior cephalograms. Therefore. potentiality that can construct postoperative three dimensional image without three dimensional computed tomography after surgery was presented.

  • PDF

Analysis of Genetic Diversity and Population Structure for Core Set of Waxy and Normal Maize Inbred Lines using SSR Markers (SSR 분자마커를 이용한 찰옥수수 및 종실용 옥수수 자식계통들의 핵심집단에 대한 유전적 다양성 및 집단구조 분석)

  • Sa, Kyu Jin;Kim, Jin-Ah;Park, Ki Jin;Park, Jong Yeol;Goh, Byeong Dae;Lee, Ju Kyong
    • Korean Journal of Breeding Science
    • /
    • v.43 no.5
    • /
    • pp.430-441
    • /
    • 2011
  • Maize is divided into two types based on the starch composition of the endosperm in the seed, normal maize(or non-waxy maize) and waxy maize. In this study, genetic diversity and population structure were investigated among 80 waxy maize and normal inbred lines(40 waxy maize inbred lines and 40 normal maize inbred lines) using 50 SSR markers. A total of 242 alleles were identified at all the loci with an average of 4.84 and a range between 2 and 9 alleles per locus. The gene diversity values varied from 0.420 to 0.854 with an average of 0.654. The PIC values varied from 0.332 to 0.838 with an average of 0.602. To evaluate the population structure, STRUCTURE 2.2 program was employed to confirm genetic structure. The 80 waxy and normal maize inbred lines were separated with based on the membership probability threshold 0.8, and divided into groups I, II and admixed group. The 13 waxy maize inbred lines were assigned to group I. The 45 maize inbred lines including 7 waxy maize inbred lines and 38 normal maize inbred lines were assigned to group II. The 22 maize inbred lines with 20 waxy maize inbred lines and 2 normal maize inbred lines were contained in the admixed group. The cluster tree generated using the described SSR markers recognized three major groups at 31.7% genetic similarity. Group I included 40 waxy maize inbred lines and 11 normal maize inbred lines, and Group II included 27 normal maize inbred lines. Group III consist of only 2 normal maize inbred lines. The present study has demonstrated the utility of SSR analysis for the study of genetic diversity and the population structure among waxy and normal maize inbred lines. The information obtained from the present studies would be very useful for designing efficient maize breeding programs in Maize Experiment Station, Kangwon Agricultural Research and Extension Services.

End-Shape Effect for Stress Concentration Reduction of Composite Single-Lap Bonded Joint (끝단형상에 따른 복합소재 단일겹치기 체결부의 응력집중 저감에 관한 연구)

  • Kim, Jung-Seok;Hwang, Jae-Yeon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.3
    • /
    • pp.333-340
    • /
    • 2011
  • We evaluated the stress-reduction effect for different shapes of a composite adherend with or without a spew fillet. Six different single-lap joint specimens were modeled and assessed using nonlinear finite element analysis. Moreover, we investigated the effect of the stiffness ratio of the adherend and adhesive. The single-lap joint with normal tapering had the highest stress values, and the single-lap joint with reverse tapering and a spew fillet had the lowest stress values. The composite adherends with higher stiffness had lower stress values, and the adhesives with lower stiffness had lower stress values.

An Experimental Study on the Absorption Performance of Ceramic Materials (세라믹 소재의 흡음성능에 관한 실험적 연구)

  • Song, Hwa-Young;Seo, Eun-Sung;Kim, Hyung-Tae;Lee, Sung-Min;Lee, Dong-Hoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.163-167
    • /
    • 2009
  • In this study, the acoustic properties of ceramic sound absorbing materials with different thickness and bulk density were investigated in terms of characteristic impedance, propagation constant, and absorption coefficient. The well-known two-cavity method was used for evaluating those acoustic parameter values. Also, in order to validate the experimentally measured values, the results were compared with the results obtained from Chung and Blaser's transfer function method and SWR method. The experimentally measured values of normal absorption coefficients were generally agreed well with the corresponding values from the transfer function method and the SWR method. Based on the experimental results, the following conclusions could be made. The magnitude of the absorption coefficient and the frequency range of the maximum absorption coefficient were controllable by changing the thickness and bulk density of the sound absorbing materials.

  • PDF